Loading...
HomeMy WebLinkAboutPRODUCT APPROVALCompliant with Florida Building Code 2017.(611 ed.) Compliant with Florida Product Approval/Rule # 61G20-3 Compliant: Keystone Certifications ' I 1 2160 SW Poma Drive Palm City, FL 34990 072 W2-$0..34 vqr � x i yr 1 �� ' •Y 1,� Department County, FL Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC f Sec.1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 915TM'Cl4em-Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. , Underiayment: To be compliantt with FBC Sec 1507.1.1 Slope: Shall be in compliance wpth FBC Sec.1507. METHOD 1 METHOD 2 Install Details: Table A Allowab,'le Loads -97.25 PSF Perimeter _..0 _ — ': DESIGN PRESSURE* 1 i -86 PSF Main fiel _-......_..._: - 6" O.C. FASTENER SPACING 6" O.C. 1 SEAM ADHESIVE Not required 3/16" continuous bead (see details Reference Data: ARCHITECTURAL TESTING, INC. TS`i ID#: 1527 06/30/15 Specimen #1 & #Z :. Ul 580-06 & UL 1897-04 TEST REPORT 08133.01-450-18 EQUIVALENCY: UL1897-04 rs equivalent to Test standard UL1897-12 *Design Pressure margin of safety.. 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial i'gWg3t6rr jWy,company manufacturing or distributing products under this evaluation. _ .+. •;y Locke Bowden, P.E. is not owned,,'operated, or controll-� Ce�4Y'��anY4 tuner, or distributing products under this report. is 74 seat '�. o: • STA i e OF �°0t, NAI- �y, i Limitations: 1. Undedayment to be compliance with current Florida Building Code (FBC)2017 611 ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 6�1 ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method:1-D 4. Engineering analysis for °project specific approval by local authorities w1jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report 6. Support framing in compliance w/FBC 2017 61" ed.: Chapter,,22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 11 7. This report does not imply warranty, installation, recommended product use outside of this report I FL 17022.6 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details 16" I I I Panel Profile 16" o. c. _i 3/4" —L-- Deck: -16132" or greater Plywood, or - Wood plank integral Snap Lock For METHOD 2: Apply 3116" Bead Bostik 915TM' Sealant Continuous Along Male Rib Vertical Flange Fastener #10 X 1" Min. per Table "A' Pancake Head Wood Screw (Typical Fastening Pattern Across Width) FL 17022.6 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details I Fastener #10 x 1" Min. per Table "A" Pancake Head Wood Screw 1" Nail Strip Roof Panel Deck: -15/3Z' or greater Plywood, or - Vlibod plank isometric View Seam Adhesive Application: For Method 2 Apply 8Hs" Bead Bostik 915Tm Sealant Continuous Along Male Rib Vertical Flange (Refer to Table " M Florida Building Code Online Page Business • 1 I < BCIS Home Log In ;User Registration Hot Topics ; Submit Surcharge i Stats & Facts ! Publications FBC SbR BCLS' Site Map i Unl¢ I Search ri(� t:, Product Approval 005� - 06 R Z +4 " USER: Public User T ST'. LIIC�' �'OUi�TY BUII.Ili SIGN —:.�:: w REW EVVED FOR COIN ;:::;.,sit_:;: Product Approval Menu > Product or Application Search�> Aopiication List > Application Detail- / t EVI..�.WED B FL j F-17022-R7 DATE 17 Application Type / Revision PLANS AND PERMIT MUS BE KEPT ON JOB Code Version 2017 OR NO INSPECTION WILL BE MADE. Application Status Comments Archived Product Manufacturer % Address/Phone/Email / / Authorized Signature Technical Representative Address/Phone/Erna I Quality Assurance Representative Address/Phone/Email Category Subcategory compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By I i Certificate of Independence Approved 08/18/2017v. date reapply 08/21/17 Extreme Metal Fabricators, LLC 2160 SW Poma Drive THESE PLANS AND ALL PROPOSED WORK Palm City, FL 34990 872-80 Rvalidation ARE SUDaJECT TO ANY CORRECTIONS Rvalidaton@yahoo.com Flva li REQUIRED BY FIELD INSPECTORS THAT Richard McKuhen MAY BE NECESSARY IN ORDER TO Flvalidation@yahoo. com COP+9PLY WITH ALL APPLICABLE CODES. Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 872-803 rc and@emfab4net CONUXED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received LOCKE BOWDEN PE-49704 Keystone Certifications, Inc. 04/22/2024 Zachary R. Priest, P.E. :fie Validation Checklist - Hardcopy Received FL17022 R7 COT FL 17022.1. 5 V CRIMP ssr.odf Referenced Standard and Year (of Standard) Standard TAS 125 UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 2012 2006 r ! r hops://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=WGEVXQvrt•Dgv2e1$QPHPQQ••• 'u16r2o1$ Florida Building Code Online Page 2 of 4 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL* _ i Model, Number or Method 1 Option D 08/18/2017 08/25/2017 08/28/2017 10/10/2017 Description I 37022.1 1 " VLCrimp" (+R6j 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer, to manufacturer's installation instructions. 17022.2 12 - "5V Crimp" (116) Limits of Use Approved for use in HVHZ: No I Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions.Insta'll the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer io manufacturer's installation instructions. 17022.3 13 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and i limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.4 14 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. install the assembly in compliance with Installation Instructions FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE =L 17022.1 5 V CRIMP ssr.odf Created by Independent Third Party: Yes 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Installation Instructions FL'702 R7 II FL 17022 2 5 V CRIMP 0.032 ALUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.Ddf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Installation Instructions FL17022 R7 rI FL 17022 3 1 5 MECHANICAL seam 2408 ssr.odF Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL17022.3 1.5 MECHANICAL Seam 24oa ssr.odf Created by Independent Third Party: -Yes 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with dips and fasteners. Installation Instructions FLi7022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCCAl_ SEAM ALUMINUM ssr.odf Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 7022.5 1.0 NAIL5TRIP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes IEvaluation Reports FL17022 R7 AE FL 17022.5 1 0 NAILSTRIP ssr.odf Created by Independent Third Party: Yes https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQw-tDgv2aBQpHPQQ... 2/16/2018 Florida Building Code Online '4 ' Page 3 of 4 the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 6 - "1 in. Nail Strip" (RS)' I � I Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.7 17 - "1.5 in. Nail Strip" Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 18 - "EMAX Rib" (RS) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL! 7022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUP1 ssr.odf Created by Independent Third Parry: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.odf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 177022.6 EMAX Rib ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Parry: Yes Evaluation Reports FLI 022 R7 AE FL 177022.8 EMAX Rib ssr.odf Created by Independent Third Party: Yes �70Z2.9 �" PBR MAX" (R5) 115/32"gplyw old lorwood deck with exposapped roof panel ed fastencally ers. � to Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No f Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions andl limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.9 PBR RIB ssr.odf Created by Independent Third Party: Yes ® Nesi Contact Us :: 2501 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-201 1 1 State of Florida.:: Privacy Statement :: Accessibility Statement :: ReruniiStatement under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone orlby traditional mail. if you have any questions, please contact 850.487.1395. `Pursuant to Section 455.275(1), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a lioatsce under Chapter 455, F.S., please dick hM. Product tAApproval Axepts: ® I I I C;Mdr Card Sale https://www.floridabuilding-org/pr/pr_app_dtl.aspx?param=w'GEV XQwtDgv2aBQpHpQQ•.. 2/16/2018