HomeMy WebLinkAboutREVISIONOFFICE USE ONLY: �y SGA�NE®
DATE FILED: I - Le ' � b S� Luci County PERMIT # - l
REVISION FEE: 9,) �b RECEIPT # \l-A O `S1 t
PLANNING & [DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION RECEIVED
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652 J U L 0 6 2018
(772) 462.1553
ST. Lucie County, Permitting
APPLICATION FOR BUILDING PERMIT REVISIO
PROJECT INFORMATION
i
LOCATION/SITE I
ADDRESS:
5001 SAN DIEGO AVE FORT PIERCE FL 34946
I
i
DETAILED DESCRIPTION OF PROJECT
REVISIONS: I
NEED TO REPLACE THE PRODUCT APPROVAL FROM SNAPMAX 1 "NAILSTRIP TO 5V CRIMP.
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1
BUSINESS NAME: ROOF DOCTORS
QUALIFIERS NAME: CALVIN LARS C
ADDRESS: 2550 SE PERUGIA ST
CITY: PORT ST LUCIE
PHONE (DAYTIME): 772-280-8618
ISTENSEN
(STATE: FL
11
OWNER/BUILDER INFORMATION:
NAME: N/A I
ADDRESS: I
ST. LUCIE CO CERT. #: 8317
ZIP: 34952
FAX: N/A
CITY: STATE:
PHONE (DAYTIME: FAX:
i
ARCHITECT/ENGINEER INFORMATION:
I
NAMEN/A
ZIP:
ADDRESS: i
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
SLCCC: 9123109 '�
Revised 06/30/17 5� t, . _q
REVISION
Florida Building Code Online
Page 1 of 3
BCIS Home ( Log In I User Registration i Hot Topics ISubmit Surcharge I Stats & Facts ( Publications 1 Contact Us I BCIS Site Map I Links f Search '
R riCb
Product Approval r�
pr
0 USER: Public User y RECEIVED
Product Approval Menu > Product or Application Search > A I Pplication Lis[ > Application Detail J U L 0 6 2018
FL # FL17022-R7
Application Type I Revision ST. Lucie County, permitting
Code Version 2017
Application Status I Approved
Comments
Archived
171
08/18/2017v. date reapply 08/21/17
Product Manufacturer Extreme Metal Fabricators, LLC� W
Address/Phone/Email I 2160 SW Poma Drive�,LAC r,0Palm City, FL 34990 WISION
(772) 872 8034 R'EVM1i F,D FO
flvalidation@yahoo.com REVIEWEl� BY
D.dATE __ 71(01 Ig
Authorized signature Richard McKuhen PLANS AND PERMIT A ST RE KEPT ON JOT
flvalidation@yahoo.com OR NO 1INSPECT1014 IVML BE A1,125b,
i
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
I
richard@emfab.net THESE PLANS AND ALL PPIOPOSED'IttiORK
Quality Assurance Representative ARE SUBJECT TO ANY CORRCCT&I•S
Address/Phone/Email REQUIRED BY FIELD INSPECTOR'S' TEAT
MAYBE NECESSARY IN ORDER 10
Category Roofing COMPLY WITH A" APPL AKS 099E9,
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
I
Florida Engineer or Architect Name who developed LOCKE BOWDEN CONCEALED FASTENERS OR ATTACHMENTS
the Evaluation Report .ME THE RSSRONSISIM OF THE
Florida License � PE-49704 J'1 fl5 �7P 'q 9 1I f f (1�•
Quality Assurance Entity I Keystone Certifications, Inc. Cj�RMTn`�AE A� ®Rf�ri6R
Quality Assurance Contract Expiration Date 04/22/2024 elu 'w ytl ``dd t1Gb�iI1�
Validated By Zachary R. Priest, P.E.
® Validation Checklist - Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
i
Equivalence of Product Standards
Certified By
Sections from the Code
J
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe... 7/5/2018
Florida Building Code Online Page 2 of 3
Product Approval Method i Method 1 Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
FL # I Model, Number or Name I Description
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use I Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf
Approved for use outside HVHZ: Yes I Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022A 5 V CRIMP ssr.odf
assembly in compliance with the installation method listed in Created by Independent Third Party: Yes
this report and applicable code sections of, FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (116)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Limits of Use I
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes,
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf
Created by Independent Third Party: Yes
manufacturer's installation instructions.
17022.3
3 "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24ga ssr.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A I
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly; in compliance with the
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
installation method listed in this report and applicable code
seam 24ga ssr.odf
sections of FBC. Refer to manufacturers installation
Created by Independent Third Party: Yes
instructions.
17022.4
4 - "1.5" Mechanical Seam" (115)
I
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use I
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 fI FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: ,Yes
ALUMINUM ssr.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
FL17022 R7 AE FL 17022,4 MECHANCIAL SEAM
installation method listed in this report and applicable code
ALUMINUM ssr.odf
sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.5 5 "1 in. Nail Strip" (115) 1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use ! Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A, Evaluation Reports
Other: Refer to evaluation report1for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr odf
limitations of use. Install the assembly in compliance with the Created by Independent Third Party: Yes
Installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe... 7/5/2018
Florida Building Code Online
Page 3 of 3
17022.6 16 - "1 in. Nail Strip"J(115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
1" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
Installation Instructions
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.odf
Created by Independent Third Party: Yes
17022.7
7 - "1.5 in. Nail Strip" (115)
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.odf
Created by Independent Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.8
8 - "EMAX Rib" (R5)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 177022.8 EMAX Rib ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No i
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 177022.8 EMAX Rib ssr.odf
limitations of use. Install the assembly incompliance with the
Created by Independent Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.9 9 - " PBR MAX" I (R5) 26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use I
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.9 PBR RIB ssr.Ddf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No I
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A I
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.9 PBR RIB ssr.pdf
limitations of use. Install the assembly in compliance with the
Created by Independent Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions. i
Back Next
I
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 phone: B50-487-1624
The State of Florida is an AA/EEO employer! Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
I click here .
Product Approval Accepts:
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aB QpHpQQe... 7/5/2018
I
Palm City, FL 34990
Compliant with Florida Building Code 20i7 (6 1h ed.)
Comp I I
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA SteelRoof Pan I lei FBC Sec. 1507.4.2
Yield strength: go ks! min.; Attached to min. 15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec'. 1507.4.3
Fastener 1 (Method 1 Attachment): #9 X 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru'deck or 5/8" embedm.e,int into wood plank. (*or sufficient length to Meet,
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8� embedment into wood plank. (*or sufficient length
to meet requirements)
Uriderlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC,1Sec, 1507.
See Fastener attachment specifications above
.......... .
... . ........ . .... .
Install Details: Allowable, LoadsMETHOD 1 11 _..MfT_HQD,2, jMETHOD, 3 METHOD 4
l'ji7DE$jGjN.PRES.S.l1JR,E*., -86 PSF 1, :793.5 PSF 1 401 PSF - V - -228 1
_PSF ,
]"FASTENER .SPACING ,width) ox., 12" (ALONG Panel .............. 12M.P. 113�;__. p.c. 12" ox.
FASTENER SIZE #9 #10 #10 j[ '410''
Reference Data: ARCHITECTURAL TESTING,, INC. TST ID#: 1527
UL 580-06 & 1897-041 Test Report DC5893.01-450-18 OS/02/14
Test Report F3366.01-450-18 12/18/1S
TAS 125-03 Test Report D05893.02-4S0-18 07/22/14
*EQUIVALENCY-UL1897-04 is equivalent to test standard UL 1897- *Design pressure margin of safety 2.1
1 ;0jq%1
. ........................ ....... ......... . ..... ................... ... ............. . ... . ...........
Locke Bowden,, P.E. does not have, not will acquire 4 financial
,under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by a
,report.
�4,
coiAparNornbilifkatureoffit or
or distributing products
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shearldiaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading. l
7. This report does not imply warranty, installation, recommended product use outside of this report.
m/
0
Deck:
-15/32" or greater Plywood, or
Vlbod plank
Fasteners -
#9lx 1-1/2" Min, or
#10 x 1-1/2" Min. per Tab/e'A" for Row 5•V Crimp Roof Panel
l Spacing and Design Pressures
Hex Washer Head Wood Screws
Z4
1�' I
3lZ#
I
Panel Profile
Nominal 12" Nominal 12"
D.C. O.C.
Fasten
19 X 1-1/2" Min. or #10 X 1-1/2" Min. per
—fable "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel 1Mdth
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15/32" or greater
Plywood, or
-Wood plank
I