HomeMy WebLinkAboutREVISIONExist.
Dining
�--TO EXIST.
DINING RM
/ LIGHT5
it
Exist.
Screened Terrace
ELECTRICAL FLOOR PLAN 5110A5
NEW AND RELOCATED LI6HT5 $ FIXTURES ONLY.
EXI5TING TO REMAIN UNLF-55 OTHE"15E INDICATED.
i
/InGFI GFI Exist.
° Living Rm
I � III
New Kitchen OF N�
— — \ , o y i \TO EXIST.
EXIST
J LIVING RM /
LIGHTS 5D
\ OFNOTQ
EXIST.) ST.)
--
GFI GFI
-----------------------------------
�i
/ _ 5D \
-:_ Q (IF NOT
.EXIST.) �-- �-
Exist. f` ��_, BAR
Bath #2
��
5D I 1 {.i .'
(IF O I Exi
•.� EXIST.)
I
I l
Exist.
Bdrm #2
I I
,I
i
it
ELEGTRIG RISER DIAORANI
N.T.S.
O EXIST
M DISC.
4
w
0
EXISTING
EXIST
2 PANEL 1/2 G. "A"
UNDERGROUND
TO FPL SERV.
EX15T
Exist.
Mstr Bdrm
TO EXIST.
M5TR BDRM
LIGHT5
\
TO EXIST.
\\
M5 MSTR BDRM
FAN
W.I.C/
I\
i
j
�Jw
Mstr Bath,---,
Exist.
Dining
=T = �"Wl
IF===
LL
O O� Exist. II
Kitchen
v O Exist.
REMOVE EXIST. WALLLiving RmS, J I I
.mod" GNTR5 6 APPLIANCES
4i
� 1
II I
I I � REMOTE EXIST. WALLS,
EX APPI JANGES 8 FIXTURES
Bath #2 -' - I
Exist.
Foyer �(
J
Exist.
Bdrm #2
Demolition FL Plan
10 3/16" = V-0"
STRUCTURE ABOVE
Electrical Floor Plan
U 1 /4" = SEE 1'-0"
SEE PLAN
FOR
HT
3 5/5" MTL STUDS 25 GA
0 16" O.C. (SEE PLAN) A/
1/2" GYP5UM BD AT E.5.
AT HALL5 OVER 10' HIGH
USE 22 GA. MTL5 5TUD5
i=ANEL 5GHEDULE
GIRG.#
COND.
POLE
BREAKER
HATT5
DEMAND
1-10
NEW APPLIANCES**
36
NEW REGE55ED LT5
12
1P2OA
400
31
NEW EL. OUTLETS 4 X 150IN
12
1P20A
120
EXIST, ESTIMATED ELEC. LOAD 1120 A
120 AMPS ** REPLACE EXISTING NO ADD'L LOAD
15T 10,000 WATT5 ® 100016 = 1120 REQUIRED
REMAINING 0 ® 40% = O
A/H LOAD 0 a 65% = O
1120 NATT5/240 = 4.61 AMPS
120 + 4,61 = 124.61 AMPS
EXIST. 150 AMPS SERVICE 15 ADEQUATE
ALL 120 V. 51N6LE PHASE 15A. d 20A. BRANCH CIRCUITS SUPPLYING OUTLE75
IN FAMILY RM, DINING RM, LIVING RM, DENS, LIBRARY, HALLS, 5UNROOM5,
CLOSETS AND 51MILAR SPACES, SHALL BE PROTECTED BY A L15TED ARC -FAULT
CIRCUIT INTERRUPTER COMBINATION -TYPE,
INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT.
TAMPER-RE515TANT RECEPTACLES ARE REQUIRED IN ALL AREAS.
ALL 125 V. 15A. S 20A. RECEPTABLES.
PROVIDE CARBON MONOXIDE ALARMS AITHIN 10' OF EACH BEDROOM AND IN
HALLS ADJACENT TO KITCHEN WHEN GARAGE 15 ATTACHED TO THE HOUSE.
SMOKE AND CO ALARMS, THERE REQUIRED, SHALL BE INTERGONNEGTD IN
SUCH A MANNER THAT THE ACTUATION OF ONE ALARM RILL ACTIVATE ALL
ALARMS AITHIN THE DNELLING,
ELECTRICAL LEGEND
*Q
RECESSED LED TDOANLIGHT
(VP = VAPOR PROOF)
5URFACE MOUNTED FIXTURE
JQ
JUNCTION BOX
CEILING FAN + LIGHT
❑F
EXHAUST FAN
FL LT
FLOURE50ENT PONNLIGHT
;E)
NALL SCONCE
46
FLOOD LIGHT
L
SMOKE / CARBON
50
MONOXIDE DETECTOR
o-
TELEPHONE
TV —TV
GABLE,
TELEPHONE 4IN77ERNET
❑®
OUTLET FLOOR DUPLEX
EL. OUTLET DUPLEX
SPLIT WIRED OUTLET
220 OUTLET DUPLEX
22O
GFI OUTLET
GFI
OXF/ = HEATHER PROOF)
SWITCH
TD
DIMMER SNITCH
OO * RECESSED DOWN LIGHT5 TO BE: GRE 4 IN. TH SERIES
MODEL DRDL4-O5121009-12DE261C100
11.5 N (EOUIV. TO (55 A) OR EQUAL
* TABLE LAMPS IN 5DRM5 TO HAVE LED BULBS
- ELECTR. LIGHTING EQUIPMENT MUST BE IG RATED
AND SEALED TYPE REGE55ED FIXTURES
MTL BRACING a MID
AT HALL5 OVER 5'
C. SLAB
TYP. INTERIOR WALL
Interior Wall Res. Sct.
4 1/4" = 1'-0°
STUPOR
VENT
Ic Iri.0 I
150METRIC PLUMBING RISER
N.T.5.
7 EXIST.
SANITARY
SYSTEM
Exist.
Mstr Bdrm
fF-�-_
F Il( )
LIT
4pp
u _l 4)
/ 1I
\'-A
Exist. C =
Mstr Bath ^ ,
Exist.
Dining
3' - b"
15LANP
SINK
I WiDISP.
d
I LR� New Kitchen
I
REF
Exist.
Bath #2
Exist.
Bdrm #2
CLASSIFICATION OF WORK:
ALTERATION LEVEL 2
SCOPE:
REMODELING OF EXISTING KITCHEN AND BATH AS 5HONN ON DRAAIN65.
NEW FLOORING 8 PRINTING
PRIOR TO START OF NEW CONSTRUCTION WORK, THE 6.0. SHALL VERIFY
FIELD CONDITIONS TO ENSURE THAT SAFETY CONDITIONS ARE ESTABLISHED
IN ORDER TO WORK IN A GLEAN AND SAFE ENVIRONMENT.
THE MATERIAL SPECIFIED FOR INTERIOR WORK SHALL BE EQUAL OR
51MILAR TO THE MATERIALS IN THE EXI5TING HOUSE.
A/C AND ELECTRICAL: NEW WORK AS REQUIRED.
0 EXISTING 1,NALL5 TO REMAIN
_ AALL5 TO BE REMOVED
NEW WALL5
PILLED MA5. CELL YV1#5
U.O.N.
SAA GUT AND REMOVE
m w
0
CONCRETE FOR PIPE
Z
O
" i
z
PLACEMENT. REFILL VOID
DRILL 4 EPDXY #4 DOAEL5
O w
Yy/ NEW CONCRETE.
6" LONG, 2" INTO EXIST. SLAB
�>
a m
EXIST. GONG. SLAB
A7 32" O.G. MAX
w
Lu
_..ti
U
my
9. d
0
d °
dLn
XZ
u_ m
a 0
=III III —III
u 3 3
a
EXIST. FILL 1 III
III= —III=III
J
a g Lu
_
= —III—III
ly Of
O n in
NEW GLEAN COMPAGTE
TERMITE TREATED FILL
—
NEW SANITARY PIPE
IF REQUIRED
Slab Cut Detail
U 1 1/2" = V-0"
F1
II
Exist.
Screened Terrace
Project Name:
Remodeling
Project Address:
1660 NW Federal Hwy
Stuart, FL 34994
Client Name:
Jeffrey Laughren
Revision Schedule
Revision Revision Revision
Number Date Description
3 11 1919 1 Rev 3
O
WN
Seal
Date 1/21/2019
9:33:17 AM
MANGONE
Exist.
Exist. 3 Mstr Bdrm
Living Rm Cl) O N
Cto
o
o
32 ¢ `1"
OPNG Qd
3'-4" d
J
32"X950" I ARCHITECT
NEW O G I I 05
NOTE:
EXIST, 5TI, A.LG. Mario Mangone Architect
------------------------------ 1.05T---,
O REMArN 1931 Commerce Ln,
BAR Suite 4
Jupiter FI.33458
;'4 S. - 561-743-5111
V.T.R. 04 Mstr Bath
-- -----
EXI D mangonearchitectureQgmail.com
Foy o2 GL
U Sheet Name:
GL1 Floor Plan
n Floor Plan
1/411 = 1'-0"
Door Schedule
Door
Number
Family
Door
Size
Thickness
Frame
Type
Finish
Rough
Width
Comments
02
Single -Flush
28" x 80"
1 3/811
03
Single -Flush
32"x80"
13/8"
WD
WD
04
Bfold-4 Panel
80" x 80"
1 3/8"
WD
WD
05
Single -Flush
28" x 80"
1 318"
WD
W
KtLtlVED
JAN 23 c jlq
Drawn by dm
Approved by mm
Checked by mm
Project # 18-0402
Al
Scale As
indicated