Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD CALCULATIONS.. L elISCO IJ&PIa ning & Development Services Department COUNTYBuilding & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Family Dollar - Lennard Road Project Address: 10331 Lennard Road, Port St. Lucie, Florida 34952 � Permit#: to be assigned Occupancy Type: M (S&B) Construction Type: IIB • INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or mullti-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. 4 DESIGN PARAMETERS AND ASSUMPTIONSIUSED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2010 Edition with 2012 Supplements using ASCE 7-10 2. Structure Designed as (check one): Xl Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity Vult=160 mph ASD X LRFD End Zone Width: 81-0 11 ft 5. Mean Roof Height 17.2 ft Roof Pitch: 1/2 :12 Parapet: 26.104 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): ULTIMATE Zone 1: -59•5 Zone 2: -99.7 Zone 3: -150 Zone 4: -64.5 Zone 5: -79.6 Garage: NSA PRESSURES 7. Design Loads: Floor: NSA PSF Roof/Dead: 1•5 PSF Roof/Live: 20psf Balcony: NSA PSF Dock: NSA PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: NSA PSF 8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not: Lateral structure is ordinary moment frame land longitudinal structure is concentrically braced frame 9. Is A Continuous Load Path Provided? Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 1,500 PSF Soil Test Reports Submitted? X Yes DEFERRED SUBMITTALS I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with, tk% wol structural portions of the building codes currently adopted and enforced by St. Lucie County. -°hit - structural elemei is depicted on these plans provide adequate resistance to the design Revised n IAL 0 o° alas JOE B. HUTCHERSON III, P.E. 27363 Print Name Cert # & Co. Cert Auth. MARCH ADAMS & ASSOCIATES P.O. BOX 3689 CHATTANOOGA, TN 37404 Company Name & Address COP}