Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED %orlIaMinfftergy Efficiency Code For Building Construction EnergyGauge Summit@ Fla/Com-2I010,,Effective Date: March 15, 2012 -- Form 506-2010 i Total Building Performance Method for Commercial Buildings I PROJECT SUMMARY Short Desc: FD Port St Lucie I Description: Family Dollar Port St Lucie, FL Owner: Family Dollar Addressl: 10331 Lennard Road I City: Port St Lucie Address2: State: FL Zip: 34952 Type: I Retail Class: New Finished building Jurisdiction: PORT ST LUCIE, ST LLIE COUNTY, FL (661200) Conditioned Area: 8059 SF Conditioned & UnConditioned Area: 8059 SF No of Stories: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 4.8 I I i If different, write in: I I I EnergyGauge Summit® Fla/C6m-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 8/26/2015 Page 1 of 8 I I Compliance Summary Component I Design Criteria Result Gross Energy Cost (in $) 8,173.0 8,773.0 PASSED _ LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES • HVAC SYSTEM PASSES PLANT No Entry WATER HEATING SYSTEMS PASSES PIPING SYSTEMS PASSES Met all required compliance from Check Lis ? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -= -- An input report of this design building must be submitted along with this Compliance Report I I r i I • I I • I I I vf� EnergyGauge Summit® Fla/Co -2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 • 8/26/2015 Page 2 of 8 I 3 - I I / • I hereby certify that the plans and specifications Florida Energy Code Prepared By: • Date: TIFICATIONS by this calculation are in compliance with the Building Official: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: The Hutton Date: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy Efficiency Code Architect: Larry L. Christian Reg No: #AR-0010755 Electrical Designer: Thomas Miller I Reg No: 53490 Lighting Designer: Thomas Miller Reg No: 53490 Mechanical Designer: C. Jeffrey Westbrook Reg No: 66705 Plumbing Designer: C. Jeffrey W I stbrook Reg No: 66705 (*) Signature is required where Florida i Law requires design to be performed by registered design professionals. i ooeeeoag�es000 °o 0 o° �° �* . ° m • ol. SDI ° • .pr- OF10 , m <OR\O°• ��mo :i°D•momoe� °4 EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 • 8/26/2015 i T I � Page 3 of 8 a Project: FD Port St Lucie I Title: Family Dollar Port St Lucie, FL Type: Retail (WEA File: FL ST LUCIE CO INTL.tm3) Buildiniz End Uses I)Proposed 2) Baseline 537.50 718.50 Total $8,173 $10,966 ELECTRICITY(MBtulkWh/$) i 537.50 718.50 157474 210479 $8,173 $10,966 AREA LIGHTS 174.90 235.70 51237 69049 $2, 659 $3, 597 MISC EQUIPMT 107.50 107.50 31483 31483 $1,634 $1,640 PUMPS & MISC 0.00 0.00 0 4 $0 $0 SPACE COOL 166.60 219.30 48827 64243 $2,534 $3,347 y SPACE HEAT 0.00 1.30 3 368 $0 $19 VENT FANS 88.50 154.70 25924 45332 $1,345 $2,362 Credits Applied: None PASSES Passing Criteria = 8773 Design (including any credits) = 8173.: Passing requires Proposed Building cost to be at most 80% of ' Baseline cost. This Proposed Building is at 74.5% e. i EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 • 8/26/2015 Page 4 of 8 y / ,. Project: FD Port St Lucie Title: Family Dollar Port St Lucie, FL I Type: Retail (WEA File: FL ST LUCIE CO INTL.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP i (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 1 Uncovered Parking Aieas -- Yes 0.15 19,562.0 2,934 2,560 Parking lots and Drives Ext Light 2 Main entries I Yes 30.00 6.0 180 38 Ext Light 3 Other (doors) than main entries Yes 20.00 6.0 120 30 Ext Light 4 Canopies (freestanding, attached Yes 1.25 2,920.0 3,650 360 and Overhangs) Ext Light 5 Walkways more that 10 feet Yes 0.20 96.0 19 150 wide Ext Light 6 Walk way. less than 10 feet wide Yes 1.00 80.0 80 300 Ext Light 7 Building facades (by linear foot) No 5.00 370.0 1,850 600 Ext Light 8 Internally illuminated exit signs No 5.00 2.0 10 5 Tradable Surfaces: 3438 (W) Allowance4or Tradable: 5421.56 (W) PASSES All External Lighting: 4043 (W) I Complicance check includes a excess/Base allowance of 750.00(W) Project: FD Port St Lucie Title: Family Dollar Port St Lucie, FL I Type: Retail (WEA File: FL ST LUCIE CO INTL.tm3) I� Lighting Controls Compliance Acronym Ashrae Description I Area Design Min Compli- ID (sq.ft) I CP CP ance Sales 25,001 Sales Area 7,026 4 3 PASSES Office 17 Office - Enclosed 83 1 1 PASSES Hall 5 Corridor 83 1 1 PASSES Sales Support 3 Storage & Warehouse - Bulky 749 1 1 PASSES Active Storage,' Men's 6 Toilet and Washroom 59 1 1 PASSES Women's 6 Toilet and Washroom 59 1 1 PASSES PASSES EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 8/26/2015 I Page 5 of 8 r I Project: FD Port St Lucie Title: Family Dollar Port St Lucie, FL Type: Retail (WEA File: FL ST LUCIE CO INTL.tm3) System Report Compliance Units Split Systems Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 4 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 57100 13.00 12.23 8.00 PASSES Split System < 65000 Btu/h� Cooling Capacity Heating System Electric Furnace I 38583 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1 2000 0.80 0.82 PASSES System -Supply Constant Volume PASSES Plant Compliance Description Installed Size ' Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: FD Port St Lucie Title: Family Dollar Port St Lucie, FL Type: Retail (WEA File: FL ST LUCIE CO INTL.tm3) Water Heater Compliance Design Min Design Max Comp Description Type Category Eff Eff Loss Loss liance Water Heater 1 Electric water heater <= 12 [kW] 0.96 0.96 PASSES PASSES EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 8/26/2015 i Page 6 of 8 Project: FD Port St Lucie Title: Family Dollar Port St Lucie, FL Type: Retail (WEA File: FL ST LUCIE CO INTL.tm3) Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] I [F] SF.F] Domestic and Service Hot Water 0.75 False 120.00 0.27 1.00 0.50 PASSES Systems I PASSES EnergyGauge Summit0 Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 8/26/2015 Page 7 of 8 :t: FD Port St Lucie Family Dollar Port St Lucie, FL Retail File: FL_ST_LUCIE_CO_INTL.tm3) Category Section Report 506.4.2 Operations Manual 303.3.1, 503.2.9.3 Other Required Compliance Requirement (write N/A in box if not applicable) Input Report Print -Out from EnergyGauge FlaCom attached Operations manual provided to owner 505.7.4.2� 1 Windows & Doors 502.3.2 Glazed swinging entrance & revolving doors: max. 1.0 cfm/ftz; all other products: 0.3 cfm/ftz Joints/Cracks 502.3.3 To be caulked, gasketed, weather-stripped or otherwise sealed Dropped -Ceiling Cavity 502.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls HVAC Efficiency 503.2.3 Minimum efficiencies: Tables 503.2.3(l)-(8) HVAC Controls 503.2.4 Zone controls prevent reheat (exceptions); separate thermostatic control per zone; Ventilation 503.2.5 Outdoor air supply & exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed HVAC Ducts 503.2.7 Air ducts, fittings, mechanical equipment & plenum chambers shall be mechanically attached, sealed, insulated & installed per Table 503.2.7.2. Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s) tested & balanced. Report in construction documents. Piping Insulation 503.2.8 HAC and service hot water. In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2. Heat trap required. Swimming Pools 504.7 Vapor -retardant or liquid cover or other means proven to reduce heat loss on heated pools; Time switch (exceptions); readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met Lighting Controls 505.2, 502.3 Automatic control required for interior lighting in buildings >5,000 s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 8/26/2015 Check Page 8 of 8 �M . Y • • • EnergyGauge Summit® v5.00 INPUT DATA REPORT Proiect Information Project Name: FD Port St Lucie Orientation: North Project Title: -Family-Dollar-Port_S.t Lucie, FL _ Building Type: Retail Address: 10331 Lennard Road ---Building-Glassification: _New Finished building No.of Stories: 1 State: FL, Zip: 34952 GrossArea: 8059 SF Owner: Family Dollar Zones No Acronym Description Type Area Multiplier Total Area lstl 1S11 1 FD Port Zone 1 CONDITIONED 8059.0 1 8059.0 St.Lucie 8/26/2015 EnergyGauge Summit® v5.00 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume IN [ft] [ft] plier [sf] lcfl In Zone: FD Port St.Lucie 1 Sales Sales Area Sales Area 100.00 70.26 16.00 1 7026.0 112416.0 2 Office Office Office - Enclosed 8.30 10.00 9.00 1 83.0 747.0 3 Hall Hall Corridor 8.30 10.00 9.00 1 83.0 747.0 4 Sales Support Sales Support Storage & Warehouse - 74.90 10.00 16.00 1 749.0 11984.0 Bulky Active Storage 5 Men's Men's Restroom Toilet and Washroom 8.43 7.00 9.00 1 59.0 531.1 -Women's --- Women'sRestroom Toilet and Washroom 8.43 7.00 9.00 1 59.0 531.1 El Lighting -- - ---------- No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire ]W] Ctrl pts In Zone: FD Port St.Lucie . In Space: Sales 1 Suspended Fluorescent General Lighting 63 95 5985 LM/Timer with Daylighting 2 El On/Off 2 Suspended Fluorescent General Lighting 63 48 3024 LM/Timer with Daylighting 2 El On/Off In Space: Office 1 Suspended Fluorescent General Lighting 1 56 56 Manual On/Off 1 El In Space: Hall 1 Suspended Fluorescent General Lighting 1 28 28 Manual On/Off 1 El In Space: Sales Support 1 Suspended -Fluorescent General Lighting 6 56 336 Manual On/Off I In Space: Men's 1 Suspended Fluorescent General Lighting 1 28 28 Manual On/Off 1 In Space: Women's 8/26/2015 EnergyGauge Summit® v5.00 2 a. � 1 Suspended Fluorescent General Lighting 1 28 28 Manual On/Off 1 ❑ Walls No Description Type Width H (Effec) Multi Area Direction Conductance Heat Dens. R-Value IN IN plier [sq [Btu/hr. sf. F] Capacity [Ib/cf] [h.sf.F/Btu] [Btu/sf.F] In Zone: FD Port St.Lucie 1 South Wall Wall 112.00 16.50 1 1848.0 North 0.0331 0.864 5.35 30.2 ❑ 2 East Wall Wall 78.00 17.00 1 1326.0 East 0.0331 0.864 5.35 30.2 ❑ 3 South Wall Wall 113.00 16.50 1 1864.5 South 0.0331 0.864 5.35 30.2 ❑ 4 West Wall Wall 78.00 15.00 1 1170.0 West 0.0331 0.864 5.35 30.2 ❑ --------- -- ---- _Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Total Area ------ ]Btu/hr sf F] IN [ft] plier [sf] In Zone: FD Port St.Lucie In Wall: East 1 Store Front User Defined Yes 0.4500 0.25 0.50 44.00 8.50 1 374.0 ❑ windows and Door Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier - [sf] [Btu/hr. sE F] [lb/ct] [Btu/sf. F] [h.sf.F/Btu] In Zone: FD Port St.Lucie In Wall: North 1 Back Door Solid core flush Yes 4.00 7.00 1 28.0 0.3504 0.00 0.00 2.85 ❑ (2.25) In Wall: West 1 Recieving Door Solid core flush Yes 4.00 7.00 1 28.0 0.3504 0.00 0.00 2.85 ❑ (2.25) 8/26/2015 EnergyGauge Summit® v5.00 3 4, Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier Is] [deg] [Btu/hr. SE F] [Btu/sf. F] [lb/ct] [h.sf.F/Btu] In Zone: FD Port St.Lucie 1 Roof Mtl Bldg Roof 115.00 70.50 1 8107.5 1.60 0.0248 1.91 7.65 40.3 ❑ Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [Sf] [Sf] In Zone: - In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sE F] [Btu/sf° F] [Ib/ct] [h.sEF/Btu] In Zone: FD Port St.Lucie 1 Floor 1 ft. soil, concrete H5.00 70.50 1 8107.5 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad Systems Units Split Systems Constant Volume Air Cooled Split No. Of Units 4 System ¢ 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 57100.00 13.00 8.00 ❑ 38583.00 1.00 ❑ 8/26/2015 EnergyGauge Summit® v5.00 407 Mat1407 R-19 Generic Insulation No 19.0000 0.4147 0.0218 0.30 0.2000 ❑ 414 . Mat1414 R-8 generic Insulatrion No 8.0000 0.1746 0.0218 0.30 0.2000 ❑ 80 Mat180 AIR LAYER, 4IN OR Yes 0.9200 ❑ MORE, HORIZ. ROOFS Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/et] [h.sf.F/Btu] 1047 Mtl Bldg Roof No No 0.02 1.91 7.65 40.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP_ROOFING,-3/8IN 0.0313 0.000 ❑ 2 23 6 in. Insulation 1.0000 0.000 _ __ ❑ No Name Simple Massless Conductance Heat Capacity Density RValue -- - Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1053 Wall No No 0.03 0.86 5.35 30.2 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 82 ASPHALT -SHINGLE AND SIDING 0.000 ❑ 2 91 BUILDING PAPER, PERMEABLE FELT 0.000 ❑ 3 244 PLYWOOD, 1/2IN 0.0417 0.000 ❑ 4 414 R-8 generic Insulatrion 0.1746 0.000 ❑ 5 407 R-19 Generic Insulation 0.4300 0.000 ❑ 6 80 AIR LAYER, 4IN OR MORE, HORIZ. 0.000 ❑ ROOFS 7 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 8/26/2015 EnergyGauge Summit® v5.00 7 r Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/ct] [h.sEF/Btu] --1058_-_ Solid core flush (2.25) No Yes 0.35 2.9 ❑ Layer Material Material Thickness --Framing------ No. [ft[ Factor — - -- — 1 279 Solid core flush (2.25") 0.000 ❑ 8/26/2015 EnergyGauge Summit® v5.00 8