Loading...
HomeMy WebLinkAboutBOUNDARY SURVEY & STRUCTURE DESIGNBOUNDARY 8c TOPOGRAPHIC SURVEY PERFORMED TO ALTA/NSPS LYING IN SECTION 28, TOWNSHIP 35 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA PREPARED FOR Independence TITLE FIRST AMERICAN TITLE INSURANCE COMPANY FILE NUMBER 1062-4101815. DATED AUGUST 09, 2016 ® 8:00 AM, WAS INCORPORATED INTO THIS SURVEY. 1. DEFECTS, LIENS, ENCUMBRANCES, ADVERSE CLAIMS OR OTHER MATTERS, IF ANY, CREATED, FIRST APPEARING IN THE PUBLIC RECORDS OR ATTACHING SUBSEQUENT TO THE EFFECTIVE DATE BUT PRIOR TO THE DATE THE PROPOSED INSURED ACQUIRES FOR VALUE OF RECORD THE ESTATE OR INTEREST OR MORTGAGE THEREON COVERED BY THIS COMMITMENT. —NOT A SURVEY MATTER. 2, ANY RIGHTS, INTERESTS, OR CLAIMS OF PARTIES IN POSSESSION OF THE LAND NOT SHOWN BY THE PUBLIC RECORDS. —NOT A SURVEY MATTER. 3. ANY ENCROACHMENT, ENCUMBRANCE, VIOLATION, VARIATION OR ADVERSE CIRCUMSTANCE AFFECTING THE TITLE THAT WOULD BE DISCLOSED BY AN ACCURATE AND COMPLETE LAND SURVEY OF THE LAND. —NOT A SURVEY MATTER. 4. ANY LIEN, FOR SERVICES, LABOR, OR MATERIALS IN CONNECTION WITH IMPROVEMENTS, REPAIRS OR RENOVATIONS PROVIDED BEFORE, ON, OR AFTER DATE OF POLICY, NOT SHOWN BY THE PUBLIC RECORDS. —NOT A SURVEY MATTER. 5. ANY DISPUTE AS TO THE BOUNDARIES CAUSED BY A CHANGE IN THE LOCATION OF ANY WATER BODY WITHIN OR ADJACENT TO THE LAND w PRIOR TO DATE OF POLICY, AND ANY ADVERSE CLAIM TO ALL OR PART OF THE LAND THAT IS, AT DATE OF POLICY, OR WAS PREVIOUSLY UNDER z WATER. -THERE WAS NO OBSERVED EVIDENCE AT THE TIME OF THE FIELDWORK z i 6. TAXES OR SPECIAL ASSESSMENTS NOT SHOWN AS LIENS IN THE PUBLIC RECORDS OR IN THE RECORDS OF THE LOCAL TAX COLLECTING ~ AUTHORITY, AT DATE OF POLICY. a z —NOT A SURVEY MATTER. m 7. ANY MINERALS OR MINERAL RIGHTS LEASED, GRANTED OR RETAINED BY CURRENT OR PRIOR OWNERS, —NOT A SURVEY MATTER. a 8. TAXES AND ASSESSMENTS FOR THE YEAR 2018 AND SUBSEQUENT YEARS, WHICH ARE NOT YET DUE AND PAYABLE. —NOT A SURVEY MATTER. N rn 9. RESTRICTIONS, DEDICATIONS, CONDITIONS, RESERVATIONS, EASEMENTS AND OTHER MATTERS SHOWN ON THE PLAT OF H.E. CHAMBERLAIN 0 SUBDIVISION, AS RECORDED IN PLAT BOOK 4, PAGE(S) 55, BUT DELETING ANY COVENANT, CONDITION OR RESTRICTION INDICATING A PREFERENCE, \ LIMITATION OR DISCRIMINATION BASED ON RACE, COLOR, RELIGION, SEX, HANDICAP, FAMILIAL STATUS OR NATIONAL ORIGIN TO THE EXTENT SUCH COVENANTS, CONDITIONS OR RESTRICTIONS VIOLATE 42 USC 3604(C). —AFFECTS SUBJECT PROPERTY, NOT PLOTTABLE. 0 10. RIGHT OF WAY EASEMENT IN FAVOR OF SOUTHERN BELL TELEPHONE AND TELEGRAPH COMPANY IN BOOK 764, PAGE 2863. a —DOES NOT AFFECT SUBJECT PROPERTY, AS PLOTTED. m 7 11. EASEMENT FOR INGRESS AND EGRESS, RECORDED IN BOOK 1015, PAGE 753. 00 -AFFECTS SUBJECT PROPERTY, SHOWN HEREON i tj 12. RESTRICTIVE COVENANT WITH .VESTED INTEREST IN BOOK 1310, PAGE 620.. -NOT A SURVEY MATTER. 13. RESOLUTION NO. 00-024 AS RECORDED IN BOOK 1450, PAGE 425. a -NOT A SURVEY MATTER. a 14. TERMS AND CONDITIONS OF ANY EXISTING UNRECORDED LEASE(S), AND ALL RIGHTS OF LESSEE(S) AND ANY PARTIES CLAIMING THROUGH THE LESSEE(S) UNDER THE LEASE(S). F -NOT A SURVEY MATTER. 00 CERTIFICATION o To: East Mountain Commercial, LLC, a Utah Limited Liability Company Michelle G. Trca, P.A. a First American Title Insurance Company o - - THIS IS TO CERTIFY THAT THIS MAP OR PLAT AND THE SURVEY ON WHICH IT IS BASED WERE MADE IN ACCORDANCE o WITH THE 2016 MINIMUM STANDARD DETAIL REQUIREMENTS FOR ALTA/NSPS LAND TITLE SURVEYS, JOINTLY ESTABLISHED AND ADOPTED BY ALTA AND NSPS, AND INCLUDES ITEMS 1,2,3,4,6a,6b,7a,8,9,11,13,14,16,17,18,19 & 20 OF TABLE A THEREOF. THE FIELDWORK WAS COMPLETED ON OCTOi3ER 9, 2018. Y- DATE OF PLAT OR MAP:-10/12/18 0 0 0 a Thomas P. Kiernan Signature Date 6 Professional Surveyor & Mapper Florida Certificate No. 6199 o. I COMPUTER � FILE REF. FIELD BK./PG. n s.11 CULPEPPER & TERPENING, INC CONSULTING ENGINEERS I LAND SURVEYORS 2980 SOUTH 25th STREET + FORT PIERCE, FLORIDA 34981 151 SW FLAGLER AVENUE • STUART, FLORIDA 34994 PHONE 772-464-3537 . FAX 772-464-9497 . w xt-engxom STATE OF FLORIDA CERTIFICATION No. LB 4286 aw LUCIE ?AIM BEACH ,UDERDALE VICINITY MAP 1N UT TU JI;ALL -REVISIONS — By DATE REVIEW TITLE POLICY JDJ 11 12 18 REVISIONS PER SLC SITE PLAN REVIEW DJM 12 22 18 STANDARDS JAN2 cijPermittina' 1ST. Lucie Cou LEGAL DESCRIPTION: TRACT 1, LESS THE SOUTH 883.44 FEET THEREOF AND TRACT 2, LESS THE SOUTH 883.44 FEET THEREOF, ALL IN H.E. CHAMBERLAIN SUBDIVISION, IN SECTION 28, TOWNSHIP 35 SOUTH, RANGE 39 EAST, AS PER PLAT THEREOF RECORDED IN PLAT BOOK 4, PAGE 55, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA, LESS THE RIGHT—OF—WAY FOR OKEECHOBEE ROAD (S.R. 70) AS MOST RECENTLY EXPANDED BY AGREED ORDER OF TAKING RECORDED IN ORB 777, PAGE 81, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. CONTAINING 6.65 ACRES (289,577.37sq.ft.) MORE OR LESS. PROPERTY ADDRESS: 11275 OKEECHOBEE ROAD, FORT PIERCE, FL 34945 NOTES 1) THE LAST DATE OF FIELD WORK WAS 10-9-2018, 2) ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 3) REPRODUCTIONS OF THIS MAP ARE NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 4) FIRST AMERICAN TITLE INSURANCE COMPANY FILE NUMBER 1062-4101815, DATED AUGUST 09, 2016 0 8:00 AM, WAS INCORPORATED INTO THIS SURVEY. 5) ALL ABOVE GROUND FIXED IMPROVEMENTS, IF ANY, HAVE BEEN LOCATED AND SHOWN HEREON. 6) UNDERGROUND FOUNDATIONS AND IMPROVEMENTS WERE NOT LOCATED AS PART OF THIS SURVEY. 7) FLOOD NOTE: BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS IN ZONE X, ACCORDING TO THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 12111CO164 J, MAP REVISED FEBRUARY 16 2012 THE EXACT DESIGNATION CAN ONLY BE DETERMINED BY AN ELEVATION CERTIFICATE. NO ADDITIONAL SEARCH OF THE PUBLIC RECORDS HAS BEEN PREFORMED, THERE MAY BE ADDITIONAL MAP AMENDMENTS AFFECTING THIS PROPERTY. 8) THE BEARINGS SHOWN HEREON ARE BASED ON D.O.T. R/W MAP 94030-2506 AND ARE REFERENCED TO THE BASELINE OF STATE ROAD 70 WHICH BEARS NORTH 69'44'35" EAST AND ALL BEARINGS ARE RELATIVE THERETO. 9) NO EASEMENTS ARE SHOWN HEREON OTHER THAN THOSE DEPICTED ON THE PLAT. NO SEARCH OF THE PUBLIC RECORDS HAS BEEN PERFORMED TO FIND ADDITIONAL EASEMENTS THAT MAY EXIST. 10) ELEVATIONS SHOWN HEREON ARE BASED NGS BENCHMARK "DUCK" WITH A PUBLISHED ELEVATION OF 16.65 FEET AS REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF 1988. (NAVD 88) 11) A ZONING REPORT WAS NOT PROVIDED TO THE SURVEYOR. THE ZONING IS DESIGNATED AS RF (RELIGIOUS FACILITY) AS OBTAINED FROM THE ST. LUCIE COUNTY PROPERTY APPRAISER'S OFFICE. (Oct. 2018) 12) NO WETLAND DELINEATION MARKERS WERE OBSERVED AT THE TIME OF FIELD SURVEY. 13) THE EXPECTED USE OF THE SURVEY AND MAP IS COMMERCIAL- 14) ALL MEASUREMENTS ARE IN ACCORDANCE WITH THE UNITED STATES STANDARD, IN FEET. 15) THIS SURVEY CONSISTS OF TWO SHEETS AND IS NEITHER VALID NOR COMPLETE WITHOUT BOTH. BY �`41 n?40MOO BY DATE FIELD PK 10/4/18 CALCS — — DRAWN JDJ 10/8/18 DETAILED — CHECKED I TK APPROVED I TK BOUNDARY 1& TOPOGRAPHIC SURVEY PREPARED FOR Independence Charter School DATE: 10/8/18 HORIZ. SCALE:1"=40' VERT. SCALE: N/A JOB No. 18-177 SHEET 1 of 2 a R t ` x x [ I. 501-0001-000/8] p [ 501—.0001-000/8] p /� xryo. / / xry'f St Lucie Associates I LLLP Paul H Freeman x ' ��/ "} L 4j,rr`R' ���y.l I': �j "• ^.p Xx ^O",� : ' tt X GRAPHIC SCALE : x 5 40 0 20 40 X .. x€y IN ' FEET I i = ?I i ao 1 �, €:"•' ihn•` o� t'',I <. 'V�,`8 / i Ian - 40 a .0 A A _.. I , GPO .i " SIGN 0 h "J 'Ir?6?`',. x .' ye.b i ! �b• i' �( C. .. Pry. x n,=' `1� XryH,• 5, I 0 of � A '� , t. , � �L`l11pli,tEl•?2�x x1 tpEP��{t\�tN ��(}�� ��o / �' i • � � '\ '' 4N{+.,�, :j 30 / FND 5/e".REBAR(B i ifpi� :,ttt rf+ . R� `r ✓ ry0 I�<� 0.3 SOUTH ! E, ':-,;% PiE yn.,r 0)'' \. P(�X 00 X�0 `(� t \�"to J j. 1a �c Y� SH,I P\�' SGVSN \GH I a - Q ' SIGN ,�0 h ', 12 0 ^v O / / o sr:.; Oly R� x �. I o7 X 0 X y a, E 4,r, CTJza' ry' w �a%' /X`� 1t� �y, do x Xv LEGEND8z ABBREVIATIONS X 0p ��j I+ j 1 (BB) = BASIS OF BEARINGS - - �A ' i x ` \`� X y�- �0 GION X � � �� i 30' INGRESS &EGRESS EASEMENT � (C) BENCHMARK CALCULATED DATA 1Af.�: a,. F;:- - pl PER O.R.B. 1015, PAGE 753. CB' = CHORD BEARING CID CHORD DISTANCE �, O`b'y°b _%'�/ x e5� 'n X �"-3P00� i C/L- = CENTERLINE x J y. Rr _ -�—' � C.B.S: CONCRETE BLOCK STRUCTURE �'S P 4MF�x ��:... i' x �O N if : - - ... CON C. - CCONCRE HAIN L EK FENCE X,yL % X�=, / ,0 ry COR. CORNER I•.',... I '.. X o1... „q,;.� ,^i .,•:'t" ry 1 0 v A; w, CIA - CONCRETE MONUMENT i a n ry0' I IX� Xn ry`Vo�O' (D) DEED INFORMATION tE+ ' e1I t 1a • ..t �] �� ',� �,'10. X I ow ,.: XX .. D.E. - DRAINAGE EASEMENT w :,? EL.= ELEVATION kbX Xg FND. FOUND D FLOOR x O .. - '. '; i,t,;•, �,. I wJ o:. z IP =IRON PIPE O O• ,r, 'a' a -F m IR/C = IRON ROD & CAP. X ...�X �31a' I N �. IR =IRON ROD �'\ ry tS I I f '.o I 10 L = ARC LENGTH LICENSED BUSINESS �'. x'.0, ryo. - OVERHEAD UTILITY` I I M =MEASURED DATA a tT :,;,,. LINES ON SUBJECT i ( ) 'STQg SIGN ry0. L , �:�' , = of `ss' PROPERTY MH = MANHOLE „ I i MON. =MONUMENT .� ;..�.1 X O I N / oq<.� 0�' D = NAIL & DISK 0 h ] N. R. = NON -RADIAL - STREET sIGNN� X ••` GPP �;W ,yo•, no" I o `'h Io O.R.B. = OFFICIAL RECORDS BOOK X p, X I o X �°;°Oc �ti. ,j;'o;�0h CHU = OVERHEAD UTILITIES rn �o �o �. f ` oy Y.: , r�, (P) _PLAT INFORMATION X 0 0 S i�' $t •s I YJ< XX X z x �o „.0 +t. e"Y�C ^ 7�^9• X'y .- :;• ],,,;= ( P.B. PLAT BOOK , 'S - P.CG. = PAGE OF CURVATURE a x^0oh oE� j ] ' o ryo. .. ( : ( P.I. = POINT OF INTERSECTION ­ x� -�'/ ryry. {',' ' ( xry n x .:,, I P.T. = POINT OF TANGENCY aXax Gi 1" + " Xry0 PSM - PROFESSIONAL SURVEYOR AND MAPPER I' '',' ;y, ` ' I o APPARENT - - - PL = PROPERTY LINE �y li h PHYSICAL .` I I - P.O.B. `= POINT OF BEGINNING USE P.O.C. =POINT OF COMMENCEMENT m-.XX X�xXry:(,"1'i,Ij coo 5 g0;;.;" i ,.r,'PP = POWER POLE 3¢I:,�'`1` ><N X xas;' I I i R =RADIUS 5 q1 �• °l� e, o. p+o 0+� RGE RANGE OF —WAY ry ry 1i rf`°`n ,' '. f #.".4. 1a" p 13 10 [ 501-0001-000/8] x`I' I I'C"Ib`ta o �•y SEC.' = SECTION '- Orange Avenue Baptist Church Inc " TtCX y ry 501-0004-000/9] TWR =TOWNSHIP - - P 1 °`" va. "NO BUILDINGS OBSERVED" , ,,, ` ' I Li USA Itf Seminole Tribe of FIL U.E. = UTILITY EASEMENT o' I s ' ` o` a; ^, O = BELLSOUTH MANHOLE N r 00 ® = BELLSOUTH PEDESTAL {4, = BENCHMARK ® = CATVELEC PEDESTAL p -0- FPL SINGLE PURPOSE POLE m ®. = ELECTRIC BOX = FPL COMBINATION POLE = FIRE HYDRANT — GAS VALVE Q_ N , oi', O r ,yo• xry 0 (n -i = GUY ANCHOR t'L dam:" f I i +„ I �! '# =LIGHT POLE 3 x x `"' I R .,. � I I OO = PROPERTY CORER AS NOTED O N o. ;,,, r�1., n- I ryo N° �., _ ® =SANITARY MANHOLE " fir{ o, o )< k C q,,:, ;,. `ys X C �I%< TRACTS a X o TRACY 1 { TRACT 2 j =SANITARY VALVE E 3� = SECTION CORNER X F W } In' rr '.•'" H.E. CHAMBERLIN'" H.E. CHAMBERLIN o — H,E. CHAMBERLIN ® = STORM MANHOLE. In SUBDIVISION , SUSOIVISIGN `; 1 SUBDIVISION STREET SIGN ''' r .PLAT BOOK 4, PAGE 55 '+S ,� PLAT BOOK. 4, PAGE 55 y;112' _ - PLAT BOOK 4, PAGE 55 ® = WATER METER I 4,q•, ,2' ^'.,'." ® = WATER SERVICE w _ W ".`v. '• - WATER VALVE �" i - WELL " O r.r p'7t p1' '� o O o �I } 1 ,:6 � m 10 = TITLE EXCEPTION NUMBER I O e a,t1 w -, has" x X Iz° ti o ^9. o a- R TREE Z.EGEND \ ,� ry 0f ^ ro x PALM TREE .2 K O� # 'S r9,.. ! ry0`.� -I,�AO : = PINE TREE X. ryo. ry^. X ?C E = OAK TREE. ` Iri' EXOTIC TREE [.311-0001-000/5] in , ' T�< Peter..B & Linda W Hays (TR) d- �l r Xry0 I oe,.. Xry S(, �`" Xn,x Q '' = BUSH m° Xry L1-,II X X i { X O• O `y O •� 'y vl, ti'N `1-' o x Xry ry ) ryx 9, ,/?" R BAR S89' 4 18w.' T 648. 2' } F�,o:4' So 2 971 t� 15.0 30.00' w ryp ? ryry'X to - O 3 LESS THE SOUTH 883.44' $ o t. 0 Q'— 12'.x2O' SOUTHERN BELL TELEPHONE COMPANY EASEMENT 501-0001�0 I I [ Mu °o ,yo'C,yo� e a ry0� / PER O.R.B. 764, PAGE 2863 David R. & Susan J, J, Munyan -. J✓ t > a COMPUTER FIELD BK:/PG. — R E V I S I O N S— BY DATE FILE REF. "I LP CULPEPPER & TERPENING, IN -- ry "' 4, CONSULTING ENGINEERS I LAND SURVEYORS - — 2980 SOUTH 25th STREET • FORT PIERCE, FLORIDA 34981 151 SW FLAGLER AVENUE • STUART, FLORIDA 34994 PHONE 772-464-3537 • FAX 772-464-9497 • www.ct-eng.com S'LATP OP FL,OI IDA CEIt7"IPICATI'ON No. 1,13 4286 BY DATE FIELD PK 10/4/18 CALCS. — DRAWN JDJ 10/8/18 DETAILED — — CHECKED I TK APPROVED I TK DATE 10/8/18 ALTA/NSPS Land Title Survey VERT. SCALE: N/A PREPARED FOR Independence Charter School JOB No. 18-1' SHEET 2 of IS E P A R A T E P E R M I T S R E Q U I R E D ALL FIRE PROTECTION SYSTEMS, FUEL, GAS, SIGNAGE AND OTHER BUILDING COMPONENTS REQUIRED BY LOCAL BUILDING AND FIRE AUTHORITIES TO BE INSTALLED OR MODIFIED VIA SEPARATE PERMIT, AND WHICH ARE AFFECTED BY THE WORK PROPOSED HEREIN, SHALL BE DULY INSTALLED OR MODIFIED ONLY THROUGH SEPARATE PERMIT AUTHORIZATION FROM THE AUTHORITY(S) HAVING JURISDICTION. GENERAL LIGHTING SCHEDULE NOTES: 1, MANUFACTURERS& NUMBERS ARE LISTED TO ESTABLISH QUALITY ONLY AND NOT TO LIMIT COMPETITION. TEN DAYS PRIOR TO BIDDING, SUBSTITUTIONS ARE ALLOWED SUBJECT TO SUBMITTAL DATA, PHOTOMETRICS & ENGINEERS APPROVAL AS REQUIRED BY SPECIFICATIONS, 2. ALL FIXTURES TO BE U.L. LISTED. ALL EXTERIOR FIXTURES SHALL HAVE U.L. WET LABEL OR DAMP LABEL AS REQUIRED BY LOCATION. CONTRACTOR SHALL VERIFY BEFORE INSTALLING FIXTURE. 3. CONTRACTOR SHALL PROVIDE ALL MOUNTING ACCESSORIES, BAR HANGARS& HARDWARE REQUIRED FOR A COMPLETE SYSTEM. 4, CONTRACTOR TO COORDINATE AND DETERMI NE EXACT MOUNTING HEIGHTS OF ALL INTERIOR AND EXTERIOR WALL MOUNTED LIGHT FIXTURES I N FI ELD PRIOR TO ROUGH -IN. FIXTURES TO BE UNIFORM AND CONSISTENT IN ALL APPLICATIONS. 5. IN ADDITION TO EXIT SIGNS SHOWN ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL(25) ADDITIONAL EXIT SIGNS AT THE DISCRETION OF THE ARCHITECT/ENGINEER, THE OWNER, AND/OR THE LOCAL BUILDING OFFICIAL. FOR BIDDING PURPOSES. ASSUME A 1W' RUN OF 2#12, #12G- W C ALONG WITH LABOR FOR INSTALLATION (PER SIGN). FIXTURES NOT USED SHALL BE TURNED OVER TO THE OWNER, 6. EMERGENCY BATTERY LED DRIVERS SHALL CONTAIN INTEGRAL SENSING CIRCUIT TO ALLOW FIXTURE TO BE SWATT CHED WITH AREA FIXTURES FOR NORMAL OPERATION WHERE INDICATED, AND ENERGIZE BATTERY POWERED LEOS, EQUALLY UPON LOSS OF POWER CIRCUIT, REGARDLESS OF SWITCH POSITION. MANUFACTURER SHALL BE IOTA OR BODINE EQUAL. LIGHTI_N_G_ FIXTURE SCHEDULE FIXTURE FIXTURE MANUFACTURERS LAMPS FIXTURE VOLTAG TYPE DESCRIPTION WATTAG UNIVERSAL MOUNTED EXIT SIGN WITH RED LED �1 EXA ON WHITE THERMOPLASTIC HOUSING, DIFFUSER EMERGI-LITE: ELX400-RN LED 5 UNV LENS, SPEC GRADE. (NOTE 5) UNIVERSAL MOUNTED DUAL EMERGENCY HEADS EXB EXIT SIGN W/ RED LED ON WHITE THERMOPLASTIC EMERGI-LITE: ELXN4 RN LED 5 UNV HOUSING, DIFFUSER LENS. SPEC GRADE. 4', 50M LUMEN, 35K TEMP., LED STRIP LIGHT, IA IA 22 GA. STEEL, ALL PARTS PAL, WIRE GUARD, WILLIAMS: 75R-0-1_W/835-DRWUNV LED d4 UNV C= NON -DIMMING. (FIXTURES IN THE GYM PLATFORM SPACE SHALL BE BLACK IN COLOR) IAE m ME SAME ASIA' ABOVE EXCEPT WITH INTEGRAL WILLIAMS: 75R-0L50/835-DRV-UNV-EMh0WLP LED q4 UNV SWITCHED 90 MINUTE BATTERY BACK-UP. SA SURFACE MOUNTED CANOPY LIGHT FIXTURE, SA 2500 LUMEN LED, WHITE METAL HOUSING, KENALL MS11FD-PP-MW-20L35K-DV LED 24 UNV 13 UV RESISTANT LENS, UL WET LOCATION. SAME AS'SA' ABOVE EXCEPT WITH INTEGRAL SAE SWITCHED W MINUTE BATTERY BACK-UP. SAE FIXTURE SHALL COME ON IN THE EVENT OF A KENALL: MSllFD-PP-DB-20L35K-DV.EM LED 24 UNV Ili POWER OUTAGE REGARDLESS OF CONTROLS POSITION. RECESSED 2X4, ARCHITECTURAL TROFFER, _ TA 6400 LUMEN LED, METAL HOUSING, FROSTED WILLIAMS' LT-244L64IB35-AF-DIM-UNV LED 49 UNV ACRYLIC CENTER SHIELDING, DIMMABLE, WHITE - PAINTED AT THE FACTORY. TAE SAME AS TA' ABOVE EXCEPT WITH INTEGRAL 90 WILLIAMS: LT-24-L64'B35-AF-DIM-UNV-EMAOW LED 48 UNV [;El MINUTE MINUTE BATTERY BACK-UP. TB RECESSED 2X4, ARCHITECTURAL TROFFER, TB 52M LUMEN LED, METAL HOUSING, FROSTED WILLIAMS: LT-24LSZS3SAF-DIM-UNV LED 37 UNV ACRYLIC CENTER SHIELDING, DIMMABLE, WHITE PAINED AT THE FACTORY. TBE ® TBE SAME As 'TB' ABOVE EXCEPT WITH INTEGRAL 90 WILLIAMS: LT-24-L521835-AF-DIM-UNV-EM/l0W LED 37 UNV MINUTE BATTERY BACK-UP. RECESSD 2X2, RAL TROFFER, Q 0 TC L IC CENT D, METAL HOUSING FROSTED 4"LU LUMEN LED, METAL HOUSING FROSTS ACRYLIC ACRYLIC CENTER SHIELDING, DIMMABLE, WHITE WILLIAMS: LT-22-1-49/835-AF-DIM-UNV LED 38 UNV PAINTED AT THE FACTORY. WALL MOUNTED SECURITY LIGHT FIXTURE. 8000 VJP LUMEN LED, BRONZE METAL HOUSING, FIDELUX. FWR C-80W35K-UNV LED 80 UNV UV RESISTANT LENS, UL WET LOCATION. — 0 — -- O --lw 0 0 0 i e I� ! • PAP LASS••• 0 -•• d• • • • • • • • -•• •O• • • • • -•• IO Q ••1,}P,,� • CLASSR• • ••• • ��, Q • i u 0 0 io o o of --..o is �o 0 0 oo 0 0 oa o11�=- `! —L!- --Q `oI L . I o oo o 0 0 �o 0 0 oI �o a • •• •` 1 0 0 MCLA •••Il ••• _ •I1l •�11 CLAS R•O YI. IId M M �•� r•� i•� 0 0 0 0 rol 0 Ci -------.--- :-----------.-LEI.------------- „ _---------=-.------- ...---., -------lam- a---•--o- •-----. 0000000-c -------- .o--000. t� -----•w ---o----•. -_ _.---- --�1- ------ •- -.., --_ •. i i _ Z : 4!, N :T7 o LL A:.. O p; - : Z ' W (ZO = i c� {L F- U) A- 0 kl � Z U �''''��n n I I IP IRO°• n rn Ul o a N ul ry 1T u - 0 LL Z U Q 0 � u y J N z_ ❑ J F- m 0 W D- = _ Z) CO z o F-�o� .a = Z O LL O O O Lij F_ C7 L F It W Z D O O O W J Z O w co0 LL 0 LU W W Q 2 w N LU Q_o°° Lli LL z O p W z U O ~ Z Q In pZ Z (n ❑ O a0Iw- U) W0=UUz 0 Ud ❑ 7 W oWZ Z J J = ~ Z ZLLI Q N Z 0 ❑ In LU OwF-0 LU WOUZ dF w= H U U-1 F D_ W Z❑ z w o z U) oZozZ mo 0 O LL3: z W z - co Q❑ W z o U W U)U)LL❑ J 2 U<z H� } wQ Uro Z co Z W LU LU U F- K U—' W N U N W EL W p = W 0 2 2 _ ❑ ❑ F- F- S J F- LL L0 O r M z Z U W a U) w 0 H U w 7) Of 0- :, N m 0 1 1 LIGHTING PLAN E001 / SCALE: 3/32" = l'-0" DRAWN BY: - DESIGN DATE: 11/21/2018 REVISION 1: SHEET: REVISION 2: SCALE: 3/32" = 1'-0" E00 GENERAL ELECTRICAL NOTES CONTRACTOR SHALL VERIFY ALL REQUIREMENTS FOR TELEPHONE AND POWER SERVICES WITH RESPECTIVE UTILITY COMPANIES PRIOR TO SUBMITTING THE BID. IF THEIR REQUIREMENTS ARE AT A VARIANCE WITH THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL INFORM THE ARCHITECT IMMEDIATELY. ALL COSTS INCURRED WITH THE UTILITY COMPANIES FOR SERVICES SHALL BE INCLUDED IN THE BID PRICE. IF SUCH COSTS ARE NOT AVAILABLE AT BID TIME, THE CONTRACTOR SHALL INCLUDE WITH BID, A LETTER FROM A RESPONSIBLE PARTY WITH THE UTILITY COMPANY STATING SUCH, AND COSTS WILL THEN BE EXCLUDED FROM THE BID PRICE. THIS CONTRACTOR SHALL VERIFY EXACT REQUIREMENTS FOR MECHANICAL EQUIPMENT FROM MANUFACTURERS RECOMMENDATIONS PRIOR TO ROUGHING IN CONDUIT SIZE, WIRE SIZE AND CIRCUIT PROTECTION SIZE ACCORDINGLY. IF REQUIREMENTS ARE LARGER THAN CALLED FOR ON THE ELECTRICAL PLANS, NOTIFY THE ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VISIT THE SITE OF THE WORK PRIOR TO SUBMITTING BID TO EXAMINE CAREFULLY LOCAL CONDITIONS AND DIFFICULTIES TO BE ENCOUNTERED. ANY DISCREPANCY BETWEEN PLANS AND EXISTING CONDITIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. COMPLIANCE STATEMENT ELECTRICAL SHALL COMPLY WITH ALL PROVISIONS OF THE 2014 NEC, NFPA 70 NEC 517 AND OTHER APPLICABLE CODES AND ORDINANCES. ELECTRICAL NOTES ALL ELECTRICAL WIRING EXPOSED TO VIEW IN EMT ALL ELECTRICAL IN CONDUITS, ARMORED CABLE OR BLUE CARLON CONDUIT ALL 110V EQUIPMENT RECEPTACLES MUST BE GFCI PROTECTED PER NEC 2014 210.8(B)(2) ALL CONDUITS RUN PARALLEL OR PERPENDICULAR TO STRUCTURAL FRAMING. ALL LO-VOLT WIRING BY OTHERS UNDER SEPARATE PERMIT. INCREASE WIRE SIZES FOR RUNS OVER 100' PER NEC 2014. CLARIFICATION NOTES ALL GENERAL PURPOSE RECEPTACLES WITHIN 6 FEET OF A SINK SHALL BE GFCI PROTECTED. ALL 125V SINGLE PHASE EQUIPMENT RECEPTACLES TO BE GFCI PROTECTED ON GFCI BREAKER CIRCUIT. COVERED DRIVE THRU 101 COVERED AREA COVERED AREA AJ Ilk • •i OFFICE OFFICE • & Al III — /�\ •UNGE i • •fE. f � P s] IF1111 M aw'A i ELECTRICAL NOTES Provide ARC Flash warning labels on all switchboards, panelboards, industrial control panel, meter socket enclosures, 2017 FBC (Energy Conservation) - Section C405.2.1 Occupant Sensor controls motor control centers.To be locate by contractor per NEC article 110.16 Occupant sensor controls shall be installed to control lights in the following space types: 1. Classrooms/lecture/training rooms. 2. Conference/meeting/multipurpose rooms. 2017 FBC (ENERGY CONSERVATION) - SECTION C405.6.4.1 RECORD DRAWINGS OF THE ACTUAL 3. Copy/print rooms. INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER INCLUDING: 4. Lounges. 1. A SINGLE- LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM. 5. Employee lunch and break rooms. 2. FLOOR PLAN INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. 6. Private offices. 7. Restrooms. 8. Storage rooms. 2017 FBC (ENERGY CONSERVATION) - SECTION C405.6.4.2. OPERATING MANUAL AND MAINTENANCE MANUAL 9. Janitorial closets. SHALL BE PROVIDED TO THE BUILDING OWNER 10. Locker rooms. 11. Other spaces 300 square feet (28 m2) or less that are enclosed by floor -to -ceiling height partitions. 2017 FBC (ENERGY CONSERVATION) - SECTION C408.3.1. FUNCTIONAL TEST OF THE LIGHTING CONTROL 12. Warehouses. SYSTEM TO BE DONE PRIOR TO PASSING FINAL INSPECTIONS. 2017 FBC (Energy Conservation) - Section C405.2.1.2 Occupant sensor control function in warehouses. 2017 FBC (ENERGY CONSERVATION) - SECTION C408.3.1.2. WHERE TIME -SWITCH CONTROLS ARE PROVIDED, In warehouses, the lighting in aisleways and open areas shall be controlled with occupant sensors that automatically THE PROCEDURES 1 THRU 8 SHALL BE PERMORMED. reduce lighting power by not less than 50 percent when the areas are unoccupied. The occupant sensors shall control lighting in each aisleway independently and shall not control lighting beyond the aisleway being controlled by the INSTALLED LIGHTING CONTROLS PERFORMANCE CRITERIA OF SECTION C405 TO BE PROVIDED TO THE sensor. BUILDING OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY PER FBC 6TH EDITION(2017) ENERGY CONSERVATION- SECTION C408.3.2 2017 FBC (Energy Conservation) -Section C405.2.2 Time -Switch controls. Each area of the building that is not provided with occupant sensor controls complying with Section C405.2.1.1 shall WHERE REQUIRED, DAYLIGHT -RESPONSIVE CONTROLS SHALL BE PROVIDED WITHIN EACH SPACE FOR be provided with time switch controls complying with Section C405.2.2.1. CONTROL OF LIGHTS IN THAT SPACES AND SHALL COMPLY WITH FBC 6TH EDITION (2017) ENERGY CONSERVATION CODE CHAPTER 4 SECTION C405.2.2.2, C405.2.3.2 AND C405.2.4 ANSI Standard 90.1-2016 Section 8.4.2 - Automatic Receptacle Control The following shall be automatically controlled: a. At least 50% of all 125 V, 15 and 20 amp receptacles in all private offices, conference rooms, rooms used primarily for printing and/or copying functions, break rooms, classrooms, and individual workstations. 0 b. At least 25 /o of branch circuit feeders installed for modular furniture not shown on the construction documents. T E P E R M I T S R E Q U I R E D This control shall function on S E P A R A rammed cles off at specific programmed a. A scheduled basis using a time -of -day operated control device that turnsreceptacles ALL FIRE PROTECTION SYSTEMS FUEL GAS SI NAGE AND OTHER BUILDING n ft2 and not more shall b provided for controlled areas of no more than 5000 independent program schedule s a e times —an p p o9 p FIR AUTHORITIES COMPONENTS REQUIRED BY LOCAL BUILDING AND E U TIES TO BE h control device for u to two hours nt shall be able to manual) override t e CO tINSTALLED than one floor (the occupant yP ), OR MODIFIED VIA PERMIT AND WHICH ARE AFFECTED BY b. An occupant sensor that shall turn receptacles off within 20 minutes of all occupants leaving a space; Of THE WORK PROPOSED HEREIN, SHALL BE DULY INSTALLED OR MODIFIED ONLY c. An automated signal from another control or alarm system that shall turn receptacles off within 20 minutes after THROUGH SEPARATE PERMIT AUTHORIZATION FROM THE AUTHORITY(S) HAVING determining that the area is unoccupied. JURISDICTION. All controlled receptacles shall be permanently marked to visually differentiate them from uncontrolled receptacles and are to be uniformly distributed throughout the space. Plug-in devices shall not be used to comply with Section 8.4.2. Exceptions to Section 8.4.2 Receptacles for the following shall not require an automatic control device: B „B 1. Receptacles specifically designated for equipment requiring continuous operation (24/day, 365 days/year). cuz Ia� 2. Spaces where an automatic control would endanger the safety or security of the room or building occupants. Cr-= cue Il) C"-1 YAM+iCI WWI WVMiCI IJ l l/� i 1,21 AlloB M W A i Ao 1CLASSROOM CLASSROOM am CLASSRO(?b -C AV CLASSROOM -CLASSROOM CLASSROOM Ao CLASSROOM .Id Ji I i in, 1011 •....•'1CLASSROOM• i..•1• RESOURCE 1 CLASSROOMCLASSROOM •• •• •%\ •• •.. •• 7 MIJi - low WIR AZ JIM i I I i a IN COVERED AREA M9 COVERED AREA ----------Ell ----- .. .. - o - - ----- o- -----a - - _ - - - a-:- - - o ------------ -o --- - - Q - o A% d COURTYARD 0 Aal CAFETORIUM Q AEI '•tLi• o_ o a o - o -- o o- o -_ o 0 0- o - o COVERED AREA M19 AB AB _. hS A& S O kR STORAGE All M]8 M]B hl M Y S PREP RISER Ate^ O 1 -,O > .a B S1JYL n v Ma qy MO Aw A" ME, M9] As+ MI A31 0.8 O JANITOR A N DATA/ ELECTRICAL M A " M "� ° Ab All n CORRIDORN O M M ®A M CLASSROOM AU CLASSROOM "° "" CLASSROOM A$ CLASSROOM ^� CO�DO A CLASSROOM CLASSROOM " COGDO ® ® ® ® CORIDOR w pqy e: q#i AQ M2 P39 MD A]0 qd M6 A" A,g AN tlJ N A.N MS AH � Ado F10 M (1)2. A3! A3/ M ® A31 A31 0�I ® M3 A1Z AIR A" S a MO Ado S A. A" A95 AEB S pal Z Abi.-� C AK . RESOURCL� ® Am Am Aar As Am Ae9 M9 S M2 2 A+A M9 S AE9 qffi qk A.95 CI 6 • ART A" • & A.B M, A39 Aga I U) J nfi Am m M ® W ® ® h ® m N A N MI CASSROOM CLAR CLASSROOM N CLASSROOM CLASSRO®OM CLASSROOM o A" A.% I MB A" COMPUTERILA6 M3 M9 Mt MI M1 Mi MI Mt M1 A� A3B A39 Ao AEA A99 F35 AKf OMP CIl[ER$OtRL[TS IO BE LOCNTEp BV CONTRhCTOP _ - I• 'MIGiTAYIPIGFO AT �� I�� YRICip •J NEbdN l CU-11 CO -ID G19 L2 WPIGFG co'; CUb CW9 eM ELECTRICAL POWER PLAN E002 SCALE: 3/32" = 1'-0" ATTIC SPACE LIGHTINING PLAN E002 SCALE: 3/32" = 1'-0" ATTIC SPACE ELECTRICAL PLAN E002 SCALE: 3/32" = 1'-0" Panel 'A' load a b C load ckt description t p w a b c a b c w p t description ckt 1 lights/ music, restrooms 20 1 12 895 41 1311 12 1 20 LIGHTS/CLASSROOM & corridor 2 3 LIGHTS/CLASSROOM & corridor 20 1 12 1311 1262 12 1 20 LIGHTS/CLASSROOM & corridor 4 5 LIGHTS/CLASSROOM & corridor 20 1 12 1213 1311 12 1 20 LIGHTS/CLASSROOM & corridor 6 7 LIGHTS/CLASSROOM & corridor 20 1 12 1311 41 1311 12 1 20 LIGHTS/CLASSROOM & corridor 8 9 UGHTSIART/J ITORICOMPUTERI DATA IELECTRICAUREffiRG@A rC 20 1 12 1552 2596 12 1 20 LIGHTS/ATTIC SPACE AREA 10 11 LIGHTS/OFFICEIWNTINGRM,CORRIDOR&ADMIN 20 1 12 981 1152 12 1 20 UGHTSCORRIDORICONFERENCEL NGE,CUNIC&OFFICE.STAWREBTRO 12 13 LIGHTS/CAFETORIUM 20 1 12 956 41 980 12 1 20 LIGHTS/CAFETORIUM 14 15 LIGHTMIRESOURCESTORAGE!RISER/RESTROOMBPREP AREA 20 1 12 918 552 12 1 20 LIGHTS/COVERED AREA 16 17 LIGHTS/COVERED AREA 20 1 12 600 360 12 1 20 LIGHTS/COVERED AREA 18 19 RECEPT/MUSIC 20 1 12 1980 900 12 1 20 1 RECEPT/ GIRLS, BOYS, WF RECEPT. 20 21 RECEPT/CLASSROOM 20 1 12 1620 1800 12 1 20 RECEPT/ RESOURCE & CORRIDOR 22 23 RECEPT/CLASSROOM 20 1 12 1260 1 41 1440 12 1 20 RECEPT( CLASSROOM 24 25 RECEPT/CORRIDOR 20 1 12 1800 41 1 1980 12 1 20 RECEPT/ CLASSROOM & CORRIDOR 26 27 RECEPT/ CLASSROOM 20 1 1 12 1800 4 1 2160 12 1 20 RECEPT/ CLASSROOM 28 29 RECEPT/ CLASSROOM & CORRIDOR 20 1 12 1980 4 1 1800 12 1 20 RECEPT/CLASSROOM 30 31 RECEPT/CLASSROOM 20 1 12 1800 4 1 1620 1 12 1 20 RECEPT/ CLASSROOM 32 33 RECEPT/CLASSROOM &CORRIDOR 20 1 12 1440 4 1 1620 12 1 1 1 20 RECEPT/CLASSROOM 34 35 IRECEPTICLASSROOM 20 1 12 1 1980 1980 12 1 1 20 RECEPT/ CLASSROOM & CORRIDOR 36 37 RECEPT/CLASSROOM 20 1 12 1800 41 1980 12 1 20 RECEPT/CLASSROOM 38 39 RECEPT/CLASSROOM & CORRIDOR 20 1 12 1800 0 1 1620 12 1 20 RECEPT/CLASSROOM 40 41 RECEPT/CLASSROOM 20 1 12 2160 1980 12 1 20 RECEPT/ CLASSROOM & CORRIDOR 42 43 RECEPT/CLASSROOM 20 1 12 1980 1980 1 12 1 20 RECEPT/CLASSROOM & DATA/ELECTREAL 44 45 RECEPT/COMPUTER LAB&CORRIDOR 20 1 12 1800 41 1800 12 1 20 RECEPT/ART 46 47 RECEPT/JANITOR 20 1 12 900 720 12 1 1 20 1 RECEPT/ BOYS & GIRL RESTRM GFCI 48 49 RECEPT/CLINIC & LOUNGE 20 1 12 2160 2160 12 1 20 RECEPT/OFFICE 50 51 RECEPT/OFFICE 20 1 12 1440 1800 12 1 20 RECEPT/OFFICE 52 53 RECEPT/CORRIDOR &CONFERENCE 20 1 12 1440 1620 12 1 20 RECEPT/CAFETORIUM 54 55 RECEPT/ CAFETORIUM 20 1 12 1260 1440 12 1 20 RECEPT/RESOURCE & STORAGE AREA 56 57 recept/ computer lab 20 1 12 1800 1 1800 12 1 20 receptl computer lab 58 59 RECEPTOUTSIDE/GFCI 20 1 12 1440 14401 12 1 20 RECEPTOUTSIDE/GFCI 60 61 WM 30 2 10 3000 1000 12 1 20 REFRIGERATOR 62 63 3000 1000 12 1 20 REFRIGERATOR 64 65 1 1000 12 1 20 REFRIGERATOR 66 67 CABINET WARMING & HOLDING 20 1 12 1000 2000 12 1 20 FREEZER 68 69 CABINET WARMING & HOLDING 20 1 12 1000 1 1 1 2000 12 1 20 FREEZER 70 71 CABINET WARMING & HOLDING 20 1 12 1000 1 1 1 2500 12 1 20 ICE MAKER 72 73 CABINET WARMING & HOLDING 20 1 12 1000 1000 12 1 20 MICROWAVE 74 75 CABINET WARMING & HOLDING 20 1 12 1000 1000 12 1 20 MICROWAVE 76 77 KITCHEN RECEPT. 1 20 1 12 720 1 1000 12 1 20 MICROWAVE 78 79 SPARE I SPARE 80 a= 37,604 b= 41,491 c= 36,257 feeders panel load conduit 3" feed BOTTOM voltage 120/208 phasewire 2SETS-3#250 THHN AL main 400A watts 115,352 neutral 2SETS-1#250 THHN AL mounting SURFACE amps 321 ground #1 AL Mfg AIC 22000 - type 28c/120/208v/3o LOAD CALCULATIONS PANEL A LOAD CALCULATION CONNECTED KVA DEMAND FACTOR DEMAN LOAD LIGHTING 20.572 1.25 25.715 KITCHEN EQUIPMENT 17.5 0.65 11.375 RECEPTACLES 72 1 72 WATER HEATER 6 1 6 TOTALDEMAND 115.09 VOLTAGE 120/208 DEMANDAMPS 319.836594 UTILIZE 400 AMPS SERVICE LOAD CALCULATIONS PANEL B LOAD CALCULATION CONNECTED KVA DEMAND FACTOR DEMAN LOAD HVAC 1 162 1 162 TOTALDEMAND 162 VOLTAGE 480/277 DEMANDAMPS 195.0867052 UTILIZE 250AMPS SERVICE LOAD CALCULATIONS PANEL C LOAD CALCULATION CONNECTED KVA DEMAND FACTOR DEMAN LOAD HVAC 126 1 126 TOTALDEMAND 126 VOLTAGE 480/2778 DEMANDAMPS 151.734104 UTILIZE 200AMPS SERVICE ELECTRICAL LEGEND C, RECEPTACLE AR DUPLEX 42" A.F.F. Q DISCONNECT SWITCH HO FIRE ALARM CEILING MOUNT HEAT DETECTOR SW^ SPLIT SWITCHED OUTLET ELECTRICAL PANEL O FIRE ALARM CEILING MOUNT SMOKE DETECTOR `. 220v OUTLET g MAIN DISTRIBUTION PANEL GFCI _. GROUND FAULT OUTLET 2x4 RECESSED LED TROFFER COMBO EMERGENCY LED LIGHT /EXIT SIGN WEATHER PROOF GR OUTLET ® EMERGENCY LED EXIT SIGN ILLUMINATED SINGLE SWITCH 2x4 RECESSED TROFFER LED NIGHT LIGHT SWITCHED w/ 90 MIN. BATTERY BACK-UP ® FIRE ALARM SPEAKER/STROBE CEILING MOUNT $a 3-WAY SWITCH 4' STRIP LIGHT SWITCHED w/ FIRE ALARM SPEAKER/STROBE WALL MOUNT $b 4-WAY SWITCH m 90 MIN. BATTERY BACK-UP DIMMER SWITCH ❑❑ UNDER CANOPY LED UGHT FIXTURE O CEILING MOUNT INTERCOM SPEAKER $os OCCUPANCY SENSOR SWITCH EXHAUST FAN LED LIGHT / WA WIRELESS ACCESS POINT m � UNDER CANOPY LED LIGHT FIXTURE w/ 90 MIN. BATTERY BACK= UP Tviiz TRANSFORMER Panel rBr load a b C load ckt description t p w a b c a b c w p t description ckt 1 AHU-1 20 3 12 2000 2000 12 3 20 AHU-2 2 3 2000 2000 4 5 2000 40 2000 6 7 CU-1 20 3 12 4000 4000 12 3 20 CU-2 8 g 4000 4000 10 11 4000 4000 12 13 AHU-3 20 3 12 2000 2000 12 3 20 AHU-4 14 15 2000 2000 16 17 2000 2000 18 19 CU-3 20 3 12 4000 4000 12 3 20 CU-4 20 21 4000 4000 22 23 4000 4000 24 25 AHU-5 20 3 1 12 2000 2000 12 3 20 AHU-6 26 27 2000 2000 28 29 2000 2000 30 31 CU-5 20 3 12 4000 4000 12 3 20 CU-6 32 33 4000 4000 34 35 1 4000 4000 36 37 AHU-7 20 3 12 2000 2000 1 12 3 20 AHU-8 38 39 2000 2000 40 41 2000 2000 42 43 CU-7 20 3 12 4000 4000 12 3 20 CU-8 44 45 4000 4000 46 47 4000 4000 48 49 AHU-9 20 3 12 2000 4000 12 3 20 CU-9 50 51 2000 4000 52 53 2000 40 4000 1 54 55 56 57 58 59 11 60 a= 54,000 b= 54,000 c= 54,000 feeders panel load conduit 3" feed BOTTOM voltage 480/177 phase wire 3#350 THHN AL main 250A watts 162,000 neutral #350 THHN AL mounting SURFACE amps 195 ground #2 AL Mfg AIC 65000 type 480/277/30 Panel 'C' load a b C load ckt description t p w a b c a b C w p t description ckt 1 AHU-10 20 3 12 2000 4000 12 3 20 CU-10 2 3 2000 4000 4 5 2000 4000 6 7 AHU-11 20 3 12 2000 2000 12 3 20 AHU-12 8 9 2000 2000 10 11 2000 2000 12 13 CU-11 20 3 12 4000 4000 12 3 20 CU-12 14 15 4000 4000 16 17 4000 4000 18 19 AHU-13 20 3 12 2000 4000 12 3 20 CU-13 20 21 2000 4000 22 23 2000 4000 24 25 AHU-14 20 3 12 2000 40 4000 12 3 20 CU-14 26 27 2000 1 1 4000 28 29 2000 4000 30 31 AHU-15 20 3 12 2000 41 2000 12 1 3 20 1 AHU-16 1 32 33 2000 41 2000 34 35 2000 2000 36 37 CU-15 20 3 12 4000 11 4000 12 3 20 CU-16 38 39 4000 4000 40 41 4000 4000 42 43 SPARE 40 SPARE 44 45 SPARE 41 SPARE 46 47 SPARE SPARE 48 a= 42,000 b= 42,000 c= 42,000 feeders panel load conduit 3" feed BOTTOM voltage 480/277 phase wire #250 THHN AL main 200A watts 126,000 neutral #250 THHN AL mounting SURFACE amps 152 ground #4 AL Mfg AIC 65000 type 480/277/30 *CONTRACTOR TO CONFIRM THIS INFORMATION WITH ELECTRICAL COMPANY SECONDARY FAULT CURRENT: 23,800 A (BASED ON 300 kVA 120/208V / 3 = 3.5%) MAX. AVAILABLE FAULT CURRENT AT SERVICE EQUIPMENT: 18,034 A BASED ON: NO. OF CONDUCTORS ON PHASE: 1 TYPE: 250 kcmil VOLTAGE: 120/208V 3-PHASE LENGTH: 30 FEET 12/03/2018 VOLTAGE DROP THE PLANS REFLECT SYSTEM VOLTAGES DROP AS PER FBC ENERGY CONSERVATION 2017 SIXTH C405.6.3. FEEDER CONDUCTORS ARE EISIZED FOR A MAXIMUM VOLTAGE DROP OF 2 PERCENT AT DESIGN LOAD. BRANCH CIRCUIT CONDUCTORS ARE SIZED FOR A MAXIMUM VOLTAGE DROP OF 3 PERCENT AT DESIGN LOAD. . FPL TO LOCATE UTILITY TRANSFORMER PAD MOUNTED UTILITY TRANSFORMER W/ SERVICE METER MAIN DISTRIBUTION PANEL 0 F (2) 500 X 10' 0" GND RODS ' @6'0"O.0 TY112 TRANSFORMER KVA RATING:112.5 GND. PER NEC ARTICLE #250 C D E-D�l A ; 3SETS-3#500 THHN AL #350 THHN AL - 3SETS-1#500 THHN AL -' #350 THHN AL 1#350 THHN AL #2 THHN AL PANEL PANEL PANEL �B) 4SETS-3#250 THHN AL ; E rl #250 THHN AL 0 4SETS-1#250THHN AL #250 THHN AL 4 250 200 1#350 THHN AL #4 THHN AL C) 2SETS-3#250 THHN AL F 1#3/0 THHN AL 2SETS-1#250 THHN AL - #1THHN AL 615 fn W F- U W W a- L O F- F- Z 0 V J J v �J JLL C W o' Fo0)- W W M � = C? ¢Uri LL. vaa 0 z 0 J — 0 m a w LL x x :3 F~ co wo 4 Z O LL H 00 (DU) WZZ 0 oow Z Lu 0Ma-0 2 0 Zo� 0OU w a.0C0 LL z oZ�o 00 W Q LL W 0Qo�z os Z W zco00w Q 0 En W Z QZQN ZF- O J W U J LL = 0 w o z W m=COw = U 0 (D (n Z K U W 0 0 z z LL Z 0 :E 0 V W Lu Ln� L� >aw�5 Lu Loj U� n W LA U W = wOix [__� P4 z 0 0 w r r C, w x x W U Z ¢U5 J LLz o� U J ?a oa w� aI- w3 LLw 0 W OU [11 Q � x5 �m � o LLaf w O J LL CI m H 0 _ro O z v w O a DRAWN BY: W.J.S. DESIGN DATE: 10/24/2018 REVISION 1: DATE I PAGE: REVISION 2: DATE C00 SCALE: 3132" = V-0' C Y COMMUNICATIONS VOICE CLOSET CABLE I-- RUN PIHSOUNE CATS PATCH IN SAME ROO SYSTEM UNIT. CABLE RUN CABLE NOTES: 1 — ALL COMPONENTS PROVIDED BY ELECTRICAL CONTRACTOR 2 — ALL JACKS TO BE LABELED VOICE AND/OR DATA 3 — ALL JACKS TO BE NUMBERED TO CORRESPOND NTH PATCH PANEL 4 — PLENUM RATED CABLE TO BE USED AS REQUIRED BY CODE 5 — INSTALL 3/4• CONDUIT FROM THE BOX TO AREA ABOVE THE CEILING. IN LINE OR LOW VOLTAGE SWITCH ELECTRICAL CONTRACTOR SHALL PROVIDE 120 VOLT CIRCUIT FOR SMOKE DETECTORS VERIFY FOR EXACT LOCATION. (TYP.) DISCONNECT CABLE LIGHTING CONTROL DIAGRAM 1/2• CONDUIT WITH #12 CONDUCTOR TO OVERRIDE TIMER (1/2 - 4 HOURS) 1/2" CONDUIT WITH PULL STRING AT ENTRY POINT. ADD FD34H TIMER. TO ALARM CONTROL PANEL WHEN AVAILABLE GROUNDING ELECTRODE CONDUCTOR DETAIL BUS SERVICE EQUIPMENT GROUNDING BUS 120V - WP BUILDING ACU STEEL FULL SIZED GROUNDING (2) ASTRONOMICAL TIME SWITCH TC-1 FULL ELECTRODE CONDUCTOR SIZE (PER NEC TABLE 250-66) VOICE /DATA DOUBLE O WIRE SIZE AND RESERVE POWER FEATURE /j MODULAR JACK EACH CONDUIT NEMA 3R ENCLOSURE AND CLOCK MOTOR OF SEE RISER PHONE POSITION TYPICAL PANEL D ETAILS / VOLTAGE COMPATIBLE WITH CONTROL CIRCUIT. NDERGROUND WATER PIPE )ICE SEE PANEL SCHEDULE CONTACTOR C-1 LOCATED x COPPER IN NEMA 3R ENCLOSURE. CLAD O CLAD GROUND RODS. 20A,2P N C C SQ-D #SMG SERIES WITH CONTROL RELAY ONCRETE-ENCASED TYP. ELECTRODE DATA NOTES: TO SITE LIGHTS r " 1. VERIFY NAMEPLATE RATINGS, LOCATIONS, AND POINT OF POWER CONNECTIONS SPARE PRIOR TO ROUGH -IN. 2. DO NOT LOCATE DISCONNECT SNATCHES OVER UNIT ACCESS PANELS. SPARE 3. PROVIDE A 3/4• EMPTY CONDUIT THROUGH INACCESSIBLE LOCATIONS(I.E. WALLS, SPARE GROUND RING SEE NOTE #5. UNDER SLAB) FOR CONTROL WIRING. COORDINATE MATH MECHANICAL PLANS. 20A.1P TYP. TO BUILDING LIGHTS SEE RISER 4. EQUIP. REQUIREMENTS ARE FOR MANUFACTURE AND MODLE NUMBER LISTED ON DETAILS MECHANICAL PLANS. THE MECH. CONTRACTOR SHALL BARE ANY ADDITIONAL COST. NOTES: LIGHTING CONTROLLER 1. FULL SIZE GROUND MEANS THAT GROUND CONDUCTOR SIZE SHALL BE AS SHOWN EXTERIOR AND INTERRIOR ON SERVICE EQUIPMENT ON THE POWER RISER DIAGRAM. N.O. 20A, 120/277V. CONTACTS, 2. AFTER GROUNDING SYSTEM IS INSTALLED, GROUND RESISTANCE SHALL BE MEASURED, 120/277V COIL. NEMA 1 ENCLOSURE TO ASSURE THAT GROUND VALUE OF 5 OHM MAXIMUM RESISTANCE IS ACHIEVED. IF NOT, ADDITIONAL GROUNDING SHALL BE PROVIDED TO MEET THE SPECIFIED VALUE. 3. ALL CONNECTIONS TO GROUND RODS SHALL BE EXOTHERMIC WELD CONNECTIONS. NOTE' 4. GROUND CONDUCTOR SHALL BE LOCATED WITHIN OR NEAR BOTTOM OF CONCRETE CONTROL DEVICE TO BE INSTALL THAT AUTOMATICALLY TURNS LIGHTING FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT WITH THE EARTH, AND SHALL OFF WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE, EXCEPT SPACES CONSIST OF AT LEAST 20 FEET OF ONE OR MORE STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2 INCH DIAMETER, OR OF AT LEAST 20 FEET OF BARE MATH MULTISCENE CONTROL IN CLASS ROOMS, CONFERENCE ROOMS, AND EMPLOYEE COPPER CONDUCTOR. LUNCH/BREAK ROOMS. 5• AGROUND RING ENCIRCLING THE BUILDING OR STRUCTURE, IN DIRECT CONTACT WITH EARTH, CONSISTING OF AT LEAST (20 FT.) OF BARE COPPER CONDUCTOR NOT SMALLER THAN 2 AWG SHALL BE INSTALLED, PER ARTICLE-250.52(A)(4),NEC . LOAD VOLTAGE r1 L_J OCUPANCY SENSOR 01-161-40 MECH. EQUIPMENT POWER RISER DETAIL OCCUPANCY SENSOR AND EMERGENCY BALLAST DETAILS WALL H (BLACK) N W H (BLACK) POWER 19T 2ND PACK OCCUPANCY OCCUPANCY ODP7-070 SENSOR SENSOR (AS REQUIRED) OCCUPANCY SENSORS: LEVITON OSC10-MO 1 1 POWER PACK: LEVITON ODP7-070 ADD -A -RELAY: LEVITON ODA00-000 TO LUMINAIRES N CEILING OCCUPANCY SENSOR DETAIL WALL SWITCH TEST SWITCH TEST SWffCH H AC H AC BALLAST BALLAST EMERGENCY �EMSERGENCYBALLAST RED INDICATOR LIGHT N I IN UNSWITCHED FIXTURE ELECTRICAL DETAIL SHEET EMERGENCY BALLAST DETAILS RED INDICATOR LIGHT WALL SWITCH / SENSOR LEVITON ODSOD—IDA I N (WHITE) LUMINAIRES (IF NEEDED) TO LUMINAIRES WALL SENSOR DETAIL W pp U rag O ppW ZME30 jp KK-U EZ H IM CUUUUjUO�C 0. xwo>W> 07%_mw d W�� 3�00 Ua sa XEX Q44ZllO Z�(�2Z% li O�p Z KIWI 7aFi W 80�,`-°�aa�wg>o X41000fSN�LL�[Q'l�LL v mi V z � � T 0 00 W m Lij M Z v � O Z L LL .m a o Q . E L 0 J �U O L6 R* R* a N G E N 'QS �3F '•0, x No.60102 �•' STATE OF� E W � Q � LIFE SAFETY CODE COMPLIANCE S LIFE SAFETY CODE: 2017 6TH EDITION MEANS OF EGRESS SHALL COMPLY WITH CHAPTER 7 AND CHAPTER 39 LIFE SAFETY -MEANS OF EGRESS CHAPTER 39.2 GROUP E (EDUCATIONAL) SPRINKLERED CONSTRUCTION TYPE: V-B OCCUPANT LOAD FACTOR TABLE 7.3.1.2 OCCUPANTLOAD: OCCUPANCY GROUP: E = EDUCATIONAL THE OCCUPANT LOAD = 20 GROSS PER TABLE yZyl[�70t'I�Ii'1'�CI� PORTABLE FIRE EXTINGUISHER CALL: MAX 1,500 S.E. PER UNIT (28,868 S.F. / 1,500 = 19.24 ) # OF FIRE EXTINGUISHERS REQUIRED: 20 # OF FIRE EXTINGUISHERS PROVIDED: 22 CLASSROOM (FIXED) =486PERSONS MAX DISTANCE BETWEEN: 50' OFFICE/WAITING = 6 PERSONS RESTROOM = 6PERSONS TOTAL = 497 PERSONS COMMON PATH LIMIT -ACTUAL 654" (COMPLIES) MAXIMUM 100 ft. DEAD END LIMIT - ACTUAL: Y-O" (COMPLIES) MAXIMUM 50 ft. TRAVEL DISTANCE -ACTUAL 187'-1" (COMPLIES) MAXIMUM 300 ft. INTERIOR FINISH CLASSIFICATION LIMITATIONS PER TABLE A.10.2.2 EXITS ACCESS TO EXITS OTHER SPACES FLOORS (EXIT) A A&B A&B CLASS IORII COVERED AREA OFFICE OFFICE OFFICE OZI,ZSF (� 128253E v 12825 SF IM25SF BRG. HEIGM'1tl$ BRG HEIGT. 10'A' Ms'"EIGHT: 1014MGHEIGHT: 10'4- \\, CLG. HEIGHT: WT' CLG. HEIGHP BYf 3, CLG. HEIGHT:9-0' CLG HEIGHT: 6-0' T9 1 30 129'w' \ P'�v II_'• 4, 131 `�6v f �~ F. ® ® a - ADMIN COORIDOR 6e1.T. BRG.HE4901ISF '$ CLG. HEIGHT: WTI` 133 I ry6 h Iwkvji1m 1 ni;F BRLGG.HEIGT 10'$ C. HEIGHP-P$ 728 4G'� a51 j4�' �$951� �FFIC 134 Q5� ® �StPr �/q� 86o SF t� LOUNGE 65163F CONFERENCE MG. HEIGHT' BRG HEIGHT: 10'-0' 1HEIG T: CLG. HEIGHT._219-0' M' -1 42 ® CLG HEIGHT: Y$ 137 135 yt� �s<v'' s.9 ORAGE S!vEF {2ES`f �rn�occr _-/.__ 63 V CAFETORIUM 52U 155E BRG. HEIGHT: V CLG. HEIGHT:W$ 144 TR9y�O�T \ COVERED DRIVE THRU i 1WOCCUPANTS 2p"REQUIREO 144"DOOR WIDTH PROVIDED T CLINIC I B2 SF BAG. HEIGHT: IVY CLG. HEIGHT: 9$ II I 1 143 CLINIC REST 'i (t STORAGE V S 15,712sF MG.HEIGHT: ttl-0' CLG. HEIGHT 9- 146 r- RESOURCE 8. 23B65SF BRG.HEIGHTatl$ ,P CLG. HEIGHT: 9$ 148 \ I\ 1\ 1\ I\ ,J " " "I " PREP nN.0 SF � BRG. HEGHT 9-0$ MG HEIGHT 9'' T �. RE: RISER Ill 47,: TRAVELDRTANCEM'' aax"cxr ea --^ '1aR , ® __ _ - _- _ -_ - _ ® _ n II> I I_ LIFE SAFETY LEGEND (L �/ DIRECTION OF TRAVEL OH FIRE ALARM CEILING MOUNT HEAT DETECTOR O FIRE ALARM CEILING MOUNT SMOKE DETECTOR SECURITY LIGHT FIXTURE WALL MOUNTED COMBO EMERGENCY LIGHT / EXIT SIGN EMERGENCY EXIT SIGN ILLUMINATED FIRE ALARM SPEAKER/STROBE WALL MOUNT ® FIRE ALARM SPEAKER/STROBE CEILING MOUNT CLASS 2A10 FIRE EXTINGUISER L * SEPARATE PERMIT REQUIRED FOR FIRE SPRINKLER SYSTEM MODIFICATIONS. - PERMIT BY OTHERS . SEPARATE PERMIT REQUIRED FOR FIRE ALARM SYSTEM MODIFICATIONS. - PERMIT BY OTHERS ' THERE WILL BE A SPRINKLER SYSTEM - SEPARATE PERMIT REQUIRED COVERED AREA LIFE -SAFETY NOTES * MINIMUM 36" DOOR LEAF AS REQUIRED FOR EXIT ' EXITS SHALL BE MARKED BY AN APPROVED SIGN AND READILY VISIBLE FROM ANY DIRECTION OF EXIT ACESS * EMERGENCY LIGHTING SHALL BE PROVIDED * ONE PORTABLE FIRE EXTINGUISHER TO BE PROVIDED FOR EVERY 1,500SF OF FLOOR AREA OR PORTION THEREOF COMPLIANCE STATEMENT LIFE SAFETY PLAN SHALL COMPLY WITH ALL PROVISIONS OF THE LIFE SAFETY CODE 2017, 6TH EDITION AND OTHER APPLICABLE CODES AND ORDINANCES. H.C. COMPLIANCE NOTES CHANGES IN LEVEL AT DOOR THRESHOLDS BETWEEN 1/4" AND 1/2" EDGE SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 WITH MAXIMUM 1/2" THRESHOLD. DOOR CLEARANCES FOR FRONT APPROACH & PULL SIDE, PROVIDE 18" BEYOND LATCH SIDE OF DOOR, 60" PERPENDICULAR TO DOOR WAY. DOOR HANDLES, PULLS, LATHES, LOCKS AND OTHER OPERATING DEVICES SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. CONTRACTOR TO PROVIDE ALL HANDICAPPED TOILET FIXTURES AND ACCESSORIES PER CODE, CONTRACTOR TO MAINTAIN 60" DIAMETER CLEARANCE MINIMUM TO ALL FINISH SURFACES WHERE INDICATED ON THE DRAWINGS. I AREA TABULATION AIR CONDITIONED AREA SF 19939.9 RISER ROOM SF 47.40 ELECT. ROOM SF 352.7 OUTSIDE COVERED AREA SF 8528 TOTAL AREA UNDER ROOF SF 28,868 Ili N SW-R' ��s� \vP"�\ � r ,.. N tP[><' �OiS N III � ® ` N -OOM ® CLASSR '�a 40SR N / ® N ® Ell a . ., BRG HEIGHT: 10'A• CLASSROOM 400D4 sF .. CLASSROOM �� CLG. HEIGHT: 9-0• 704 CLASSROOM ' ; ' CLASSROOM CLASSROOM 454.43 SF ,.i I CLASSROOM / BRG. HEIGHP. 10'b' G. HEIGHT: TiY 10O SRG. HEIGHT: 10" - - LLG. HEIGHT: IiLBASSROOM RIGlff�CLG 45443 SF HEIGHT.O BRG. HEIGHT: 10'$ HE O SBF a$ 4.M`A35F BRG. HFJG IV$ CLG. HEIGHT:B$ BRG HEIGHT: IV-0' CO.HEIGHT: B'$ 112 461435E BRG. HEIGHT: IVB CLG HEIGHF:4$ GIRLS BOY15 ,4. 707 CLG. HEIGHI":B$ 106 O: 114 2]B 735E RBG, 973S iVb" 279853E R ST�ROO' IgTT RESTROO 'LG. RIGHT 9'.a �- IIV .a q 2 2 2 2 2 72 725 V I ., •``� STAFF RESTMUSIC '!\ ii fit`. 1 CLG ERG HEIGHT '19U" ® W R9636F a\ ® r� Qsr o ® Y s'�; a� 726 fID R I. Bi SF ".... s °o' ® s . B pEGHT`1 %" �' p CLG. HEIGHT $'{Y' k'\L;, �;\ ® '}}122809�3F1 C RRIDOR 'y �i`., ® `S/ CORRIDQR ---� 'o B HEtGHP 41' HEIGHT$ �'\ +v,' QiC. F 117 I EMI ;; 1J., BUG neiGIITr:1af yp,� CLASSROOM 22B 833E BRO EIGHT: m$ RESOURCE p CLASSROOM G,t16 .. CLASSROOM 4d. `� •. /� p :, CLASSROOM N CLASSROOM' CLASSROOM'. ILG. HEIG :r'$ N G CLASSROOM` 468.853E 45B955F G. HEIGHT: B-0' N 119 65895 SF MG. HEIGT: m%• :l 3W0.i3F BRG. NEIGHT:1Ud' CLG. HEIGHT:4$ "-" 39B.N3F BRIG HEIGHT: tVA' CLG HEIGT: R-W 1A iBt59 SF MG. HEIGHT: 1aJ1' MG. V-0• 450.853E BRG. HEIGHTa6'-0' CLG HEIGHT: 9$ 107 A56.95SF MG. HEIGHT. 10'A• CLG. HEIGHT: V$ 109 - BRG HEIGHT'10'$ CLG HEIGHT: 9$ 111 BRG. HEIC•T: 1V$ CLG. HEIGHT:9-0' 113 MGM 9'$ 1 1 5 \ N 102 103 HEIIGGHTI 0 COVERED -AREA - - - - - VI 25 OCCUPHRT3 EACH '•-1 -- __ __ 25OCCUPANTSEACH __ --. _. _ - _ - 480CCUPMTS EACH - 250CCUPANTS EACH COVERED AREA 72'R000RIW4oTn PRomoeo 5"REOUIRED iV REQUIRED 5"REQUIRED 72"DOOR DTH PROVIDED 3B"DOOR (MOTH PROVIDED n1wcR WIDTHPROVIDED ---- __--__----- -- ---- ° -.� -_ - -. _- - - _ _._ 'Eta '..r ---- ---- ;._T. r•.:r_----- ----- --- - - - - --- __- -. -. _. _.. — — _..---------- .. III - - - COURTYARD i600CCUPAMS / 2ff REQUIRED 1 OO OCLUPAMS 2V'REQUIRED 72- DOORWDITIPROVIDED _.. -- li TRAVEL OISTANCE)]4'40'- REQUIRED _- _ -- - _ - - _'REQUIREDI - _ - - ----- 51R1 ACH _ _. TRIED SE 36'DOORlMD'TH PROVIDED - COVERED AREA 20 ]2"IDOOR WIDTH PROVIDED >Y DWRWIOTH PROVIDED -- III _ - .; - I -� -1 _ - �¢o ']+A�LT74� (PE Qil°EIt R -- - -- -. _-- JANITOR MGIHEInD 99 _.. BRG " S ,tl%. �:, IGHT 1 DATA/ ELECTRICAL ` Qn. d, v, - I III / OTT CLG HEIGHT V-a' iv \ 154 BRG�56 t°'%" TOO HEIGHT-9-b' - S 9y p� ® �� / Odw L ® n� "'�� 0 &9 �' ® ® i�® ® I ® TC a° �� 5` a -- ----- •. CLASSROOM 473695E COmR1bOR ERG HEIGH 16I" 1 CLASSROOM 696E CLASSROOM 473696E CORRID¢R ,�° pp M QT/ CLAJJROO CLASSROOM BRG HEIGHT IU'-" 6 , I CORRId R ' CLASSROOM VLAVJROOM _--__- "- - - ---- - ,n co MG HEIGHT tO'-B CLG. HEIGHT9-a' `. HEIGHT 1 60 CLGI HEIGW; 91'-y" �� / SRG HEIGHT 1°'-9' GLGH IGHT:9a' E 16394 BRG HEIGT t°'-4' CLG. HEIGHT 9tl' , -- 2)2.]S SE MG HEIGHT 1 '% eL(Ii. HT-0 69GE BRG HEIGHT i6'-8' CLG. HEIGHT' 9'-V' i 168 CLG. HEIGHT fl'-R' 1 70 - \ BR(j 2HE1GHTFt -e" __ 474166E MG HEIGHT' 9Z CL0. IT �} ® ®160 1 — - _ 1 4 - I< --- 69 -, - 173 S 8 S z s z r1 Nrz� �ii .- n m ART c1y�OTpr g6�'� ' .. .: M HeicWHi Wt CLG. HEIGHT.9A COMPUTER LAB 1.00. '' t371� 1q4 1 r35 631 WGF BRG TO -116'%' G "0°`° y' ° S ep CLASSROOM F I CLASSROOM"' - t SSROOM S O CLASoSRO M '"Cf,sr ,, �" CLASSROOM CLASSROOM OjsT - Ve ® 157 6RG. CLG HEIGHT_.... ... BRG IGH aA CLG HE GAT I9, 9 _ ° 4W..SF ERG HEIGHT iV%' BRG HEIGHT iV%' CLG HEIGHT 9%' Fly '•... ®_w. .: . _��' 62 HEIGHF19-a' ® 1 1 1F19$ 66- vi C G z ' 166 1 67 C?k' 9%' cl.c. 1 711 172 LIFE SAFTEY PLAN A001 SCALE: 3/32" = V-13" L_ IT 67 04 LL L = EU o c J J � ` Z J = LL J W ED �om- cL W Lu 2 M Ct, Q U .- 'o !L vaa CD z m a i am U �z wo� o ce czD ) Oo EL w U, ❑ L W Z Z t o O ❑ ❑ w o z w W Q � 2 UL O Z�OV 0= = w a0�x ~ Z O LL 7 LL W YO Z Q❑ O Z a Z W W z Wp w O ❑� o gwzu) o7 LEa a Z H m w O co z m 5: _ _ co LouELw F Z K Op Z Z❑ Q D O Z Z w OU > LL S O m LL Z H< 55 =D W Z O O VJ) FL LE Q oj O Tn ~ N (n U) U) Z UU) gQ = W 0 2 2 2 J ❑ ❑ H F- H W I� I� Wp I� E5 O W J LL ~ � m LL. O NQ LL F- z Q U - DRAWN BY: - DESIGN DATE_: 10/24/2018 REVISION 1: DATE I SHEE REVISION 2: DATE ^ 0/ SCALE_ 3/32" = 1'-0" _-_ _ W to it Fw- . o MECHANICAL M001 / SCALE: 3/32" = 1'-0" 1. ALL HVAC WORK TO BE DONE IN ACCORDANCE WITH THE 2017 FBC (MECHANICAL) CODE, INCLUDING ALL STATE AND LOCAL CODES AND THE 2017 FLORIDA ENERGY CONSERVATION CODE FOR A COMMERCIAL BUILDING. 2. ALL PERMIT APPLICATIONS SHALL BE APPLIED FOR, ALL FEES SHALL BE PAID FOR BY THE GENERAL CONTRACTOR FOR APPLICABLE WORK. ALL INSPECTIONS SHALL BE SCHEDULED AND COMPLETED. VERIFY PERMIT FEES WITH THE GENERAL CONTRACTOR. 3. THIS CONTRACTOR SHALL WARRANTY THE OWNER, IN WRITING, FOR ALL THE MATERIAL AND LABOR FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE OWNER ACCEPTANCE. COMPRESSORS SHALL BE WARRANTED FOR FIVE (5) YEARS. 4. ALL DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW STRUCTURAL MEMBERS, CHANGES IN CEILING HEIGHT, LIGHTS, OR ANY NUMBER OF OTHER NECESSARY ITEMS WHICH MAY INTERFERE WITH THE EXACT INSTALLATION AS REPRESENTED ON THE DRAWINGS. THIS CONTRACTOR IS EXPECTED TO COMPLETE THE INSTALLATION AS REQUIRED WITH WHAT EVER MODIFICATIONS THAT ARE NECESSARY TO AVOID THE CONFLICTING ITEM. CONTRACTOR SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AND SHALL COORDINATE WORK WITH ALL OTHER TRADES, PRIOR TO FABRICATING DUCT WORK OR INSTALLING EQUIPMENT OR PIPING. 5. PROVIDE THE OWNER WITH REPRODUCIBLE "AS-BUILTS" DRAWINGS AT THE COMPLETION OF THE PROJECT. ALSO PROVIDE THE OWNER WITH CATALOG CUTS OF ALL ITEMS OF EQUIPMENT WHICH HAVE MOVING PARTS, AND ENCLOSE IN A 3-RING BINDER AS THE OWNER'S MANUAL. PROVIDE A TEST AND BALANCE REPORT OF AIR QUANTITIES, FREON PRESSURES, AMPERAGE DRAWS, AND AIR TEMPERATURES BEFORE FINAL PAY REQUEST. PROVE HEATING AS WELL AS COOLING. 6. DUCTWORK SHALL BE V THICK FIBERGLASS DUCT, WITH AN "R" FACTOR = 6. ALL JOINTS ARE TO BE SHIP -LAPPED AND SECURED WITH OUTWARD CLINCHING STAPLES 4" O.C. ON ALL JOINTS AND SEAMS. SEAL FOIL BARRIER WITH MANUFACTURER APPROVED 2" WIDE FIBERGLASS GAUZE AND TWO COATS OF MASTIC. SUPPORT WITH TRAPEZE HANGER OR RIGID SUPPORT EVERY 4 FT.. FABRICATE PER SMACNA LOW VELOCITY DUCTWORK MANUAL. 7. FLEX DUCT TO BE BATT INSULATION OF R-6 VALUE, WITH EXTERNAL VAPOR BARRIER AND INTERNAL SPRING STEEL HELIX AND INTERNAL POLYETHYLENE LINER. SECURE AT MAIN TRUNK DUCT WITH A SPIN -IN -FITTING BY THE LATEST METHODS AS APPROVED BY THE MECHANICAL INSPECTORS. SUPPORT FLEX DUCTS EVERY 4 FT. WITH HANGERS OR SECURE TO BAR JOIST. THREAD FLEX DUCTWORK THRU OPEN BAR JOISTS WHEN POSSIBLE. 8. ACCEPTABLE DIFFUSER AND REGISTER MANUFACTURERS ARE METAL -AIR, ENVIRO-AIRE, AIR GUIDE, TUTTLE & BAILEY AND CARNES. PROVIDE A CLEAN SET OF FILTERS WHEN THE PROJECT IS TURNED OVER TO THE OWNER. FILTER RACKS AT THE A.H.U.'S ARE TO BE TAPED UP WITHOUT ANY FILTER. FILTRATION POINT IS AT THE RETURN AIR GRILLE IN ALL CASES. PROVIDE A LIST OF FILTER SIZES FOR THE OWNER ALONG WITH A CLEAN SET OF WASHABLE FILTERS AT TIME OF TURN -OVER. 9. ALL SUPPLY COLLARS AT ROUND DUCT BRANCHES TO BE WITH BELL MOUTH FITTING, VOLUME DAMPER, AIR SCOOP AND INSIDE AND OUTSIDE CLAMPING RINGS. 10. ALL DUCT DIMENSIONS INDICATED IN THE DRAWINGS ARE CLEAR AIRSIDE DIMENSIONS. 11. PROVIDE READY ACCESSIBILITY TO DAMPERS AND OTHER PARTS OF THE SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE OR OPERATIONS. 12. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTOR BEFORE ORDERING ANY EQUIPMENT. 13. OUTSIDE AIR QUANTITIES TO BE MATCHED TO THE O.A. LISTING ON THE PLANS. 14. DO NOT SCALE DRAWINGS. SMOKE DETECTOR REQUIRED IN AIRDUCT SUPPLY SYSTEM PER SECTION 606.2.1 MECHANICAL NOTES RIGID DUCT -ALL RIGID DUCT TO BE 1" FIBERGLASS FIBRE -REINFORCED FOIL WRAPPED DUCT. -ALL 90" TURNS SHALL HAVE INTEGRAL TURNING VANES. -ALL JOINTS SHALL BE MADE USING TASON" SYSTEM TAPE AND MASTIC. IAsy Aalr"11 -ALL FLEX DUCT SHALL BE OF SIZE NOTED WITH R-6 INSULATION AND SLEEVE WRAP. -ALL FLEX SUPPLY DUCTS SHALL BE CONNECTED TO THE MAIN TRUNK LINE WITH A MANUAL DAMPER. *FINAL INSTALLATION SHALL BE FIELD TESTED AND BALANCED FOR CFM's SHOWN. COMPLIANCE STATEMENT MECHANICAL SHALL COMPLY WITH ALL PROVISIONS OF THE FBC, MECHANICAL, 6TH EDITION AND OTHER APPLICABLE CODES AND ORDINANCES. INTERIOR DOORS TO HAVE 1-1/2" CLEARANCE UNDERNEATH TO ALLOW FOR PROPER AIR TRANSFER RATES ARE PER WATER CLOSET OR URINAL. THE HIGHER RATE SHALL BE PROVIDED WHERE THE EXHAUST SYSTEM IS DESIGNED TO OPERATE INTERMITTENTLY. THE LOWER RATE SHALL BE PERMITTED ONLY WHERE THE EXHAUST SYSTEM IS DESIGNED TO OPERATE CONTINUOUSLY WHILE OCCUPIED ' RATES ARE PER WATER CLOSET OR URINAL. THE HIGHER RATE SHALL BE PROVIDED WHERE THE EXHAUST SYSTEM IS DESIGNED TO OPERATE INTERMITTENTLY. THE LOWER RATE SHALL BE PERMITTED ONLY WHERE THE EXHAUST SYSTEM IS DESIGNED TO OPERATE CONTINUOUSLY WHILE OCCUPIED FBC 607.5.4. CORRIDORS/SMOKE BARRIERS A LISTED SMOKE DAMPER DESIGNED TO RESIST THE PASSAGE OF SMOKE SHALL BE PROVIDED AT EACH POINT A DUCT OR AIR TRANSFER OPENING PENETRATES A SMOKE BARRIER WALL OR A CORRIDOR ENCLOSURE REQUIRED TO HAVE SMOKE AND DRAFT CONTROL DOORS IN ACCORDANCE WITH FBC, BUILDING. A CORRIDOR DAMPER SHALL BE PROVIDED WHERE THE CORRIDOR CEILINGS, CONSTRUCTED AS REQUIRED FOR THE CORRIDOR WALLS AS PERMITTED IN SECTION 708.4, EXEMPTION 3, OF FBC, BUILDINGS, ARE PENETRATED. A CEILING RADIATION DAMPER SHALL BE PROVIDED WHERE THE CEILING MEMBRANE OF A FIRE -RESISTANCE -RATED FLOOR/CEILING OR ROOF/CEILING ASSEMBLY, CONSTRUCTED AS PERMITTED IN SECTION 708.4, EXEMPTION 2, OF FBC, BUILDING, IS PENETRATE. SMOKE DAMPERS AND SMOKE DAMPER ACTUATION METHODS SHALL COMPLY WITH SECTION 607.5.4.1 IS E P A R A T E P E R M I T S R E Q U I R E DI ALL FIRE PROTECTION SYSTEMS, FUEL, GAS, SIGNAGE AND OTHER BUILDING COMPONENTS REQUIRED BY LOCAL BUILDING AND FIRE AUTHORITIES TO BE INSTALLED OR MODIFIED VIA SEPARATE PERMIT, AND WHICH ARE AFFECTED BY THE WORK PROPOSED HEREIN, SHALL BE DULY INSTALLED OR MODIFIED ONLY THROUGH SEPARATE PERMIT AUTHORIZATION FROM THE AUTHORITY(S) HAVING JURISDICTION. AIR BALANCE SCHEDULE UNIT HVAC SUPPLY HVAC RETURN HVAC OUTDOOR MAKE- UP EXHAUST GENERAL AREA SERVED DESIGN DESIGN DESIGN DESIGN DESIGN DESIGN AHU-1 2000 1340 660 AHU-2 2000 1355 645 AHU-3 2000 1355 645 AHU-4 2000 1355 645 AHU-5 1 2000 1355 645 AHU-6 2000 1355 645 AHU-7 2000 1355 645 AHU-8 2000 1355 645 AHU-9 2000 1355 645 AHU-10 2000 1355 645 AHU-11 2000 1355 645 AHU-12 2000 1355 775 AHU-13 2000 1355 775 AHU-14 2000 1355 775 AHU-15 2000 1355 775 AHU-16 2000 1355 775 EF-1 225 RESTROOM EF-2 225 RESTROOM EF-3 70 RESTROOM EF-4 70 RESTROOM EF-5 70 RESTROOM EF-6 70 RESTROOM EF-7 225 RESTROOM EF-8 225 RESTROOM EF-9 70 RESTROOM EF-10 70 RESTROOM EF-11 70 RESTROOM EF-12 70 RESTROOM EF-13 70 RESTROOM EF-14 70 RESTROOM TOTAL 32000 1 21665 1 10985 0 1600 0 TOTAL 250 BUILDING PRESSURE NOTE: VERIFY MANUFACTURE SPECIFICATIONS OF SPECIFIC UNITS FOR ELECTRICAL REQUIREMENTS. PLAN MANUF. MARK CU TRANE PLAN MARK AHU CONDENSER UNIT(CU)-1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 CONDENSOR UNIT Schedule MAXIMUM COOLING MCA CFM CAPACITY 2000 60,000 9- AHU SCHEDULE MOPCI SEER I EER 15 I 14.0 - MANUF. UNIT NOMINAL MAXIMUM COOLING MCA MOPC SEER EER TONS CFM CAPACITY TRANE TWE061 D400A 5 2000 60,000 17 20 14.0 - Exhaust fan schedule EF # 11 Area served Manufacture � -- CFM _ - Volt 1,2,7,8 Bathrooms Broan or equal 225 120 II �,4,5,6,9,10 Bathrooms Broan or equal 70 120 11,12,13,14 Air Device Schedule -7- i Plan I Mark Description Size Neck Material Manu£ /Model CDA Suppy Air Diffuser 24" X 24" See Plan Aluminum Price ASPD CD-2 Suppy Air Diffuser 12" X 12" See Plan Aluminum Price ASPD RG Return Air Grille 24" X 24' See Plan Aluminum Price ASPD PER TABLE 403.3 FLORIDA BUILDING CODE 6TH EDITION 2017 MECHANICAL, OA ventilation OCCUPANCY CLASSIFICATION SF OCCUPANT DENSITY Rp Ra REQ. OA PROVIDED. OA CLASSROOM 12233 25 10 0.12 4526 CFM AHU 1,2,3,4,5,6,7,8,9,10 CORRIDOR 2163 0.06 130 CFM AHU 1,2,3,4,5,6,7,B,9,10,11,12 MUSIC 948 20 10 0.18 360CFM AHU 1 OFFICE 763 5 5 0.06 65 CFM AHU 13 CAFETORIUM 5,233 150 7.5 0.18 6829 CFM AHU 12,13,14,15,16 KITCHEN 1,105 20 7.5 0.12 299CFM AHU 14 STORAGE 252 2 5 0.12 33CFM LOUNGE 265 25 5 0.06 49 CFM - COMPUTER LAB 832 25 10 0.12 308 CFM CONFERENCE 190 50 5 0.06 59 CFM OTHER 1306 - - - BATHROOM 1395 - - WAITING 187 50 T5 0.06 81 CFM ART 832 20 10 0.18 316 CFM TOTAL OA REQ. 13055 CFM NOTE: CONTRACTOR TO LOCATE ALL PROGRAMMABLE THERMOSTATS VENTILATION PLAN LEGEND SUPPLY AIR-CD1. In RETURN AIR-RG. ❑Z SUPPLY AIR-CD2. EXHAUST FAN BRAUN 9"X9",3 INCH PIPE,70 CFM UNIT OCCUPANCY SWITCH WITH LIGHT OPERATED. Fri]PLENUM AHU-1) AIR HANDLER UNIT. MANUEL DAMPER. SMOKE DETECTOR. I FLEX DUCT SCHEDULE CFM FLEX SIZE 0-50 4110 51-100 6110 101-200 8110 201-400 10,10 401-600 12" 0 601-900 14" 0 901-1,300 16" 0 �J'•/A.y/l� J o O 0, : W CD {c FW- a U J J a 01 m00 C tZ ° �J JLL C W B ro LU = M R -� QU. -� L 'D af af 0 o ao=Q FLaaaLL L w U Z 0 J F- M 0 W _ LL = L Z 0 F- Cf)o P:2 Z O w W F- ci � o t 0 U Z I- 0 o 0 w a Z N Ul om ao w ¢ 2 w w _ LL mo LU ooms LL,(L ZOLL�LL G O W U ZUZ UU ~W Z W apLOW avi Z c� Q 5 O Z a Z w ZLwZ O2 o � �°owwz M ZN= Q Z~0� J W - U _ w J w1-0X ¢_ w w 0 Z' it s = F F y w- 0 a w Z O Z� Z r> 0 WU I}i �ZOOZOZ $ Z U-` w Z 1= U W Q J K Z J U U) F- F : Z U) m Z ZU- a WCo w � O FZ- (pU UW W O = WO== =J _ 0 0 F- F- w LO o C) CD WO w 0 Z w Q w p 0 Z U a l-I-+ � O J UL Q F-I-j ~ U V1 U W) � O IY 0 U Q tY Z 0 U DRAWN BY: - DESIGN DATE: 11/21/2018 REVISION 1: SHEET: REVISION 2: moo: SCALE: 3/32" = V-0" NOTE SIZE AND RATING OF HANGERS AND SUPPORTS SHALL BE PER LATEST "SMACNA" STANDARDS. D��TmtBmTERHr DAmPRc as EXTEND UP TO STRUCTURAL FRAMING EC SITTINGSUPPORT, WRAP STRAP TO OVERLAP 4" AND FASTEN WITH 2 SHEET METAL SCREWS ROUND'5NAP LOCK' SHEET METAL OR SPIRAL LOCK SEAM FOR RUN OUTS GREATER THAN GFT., OVER 6G WRH WRAP INSULATION. (SAME AS DIFFUSER SUPPORT AS NECK) DUCT PER5MACNA THREADED STANDARDS SUPPORTVnRETOPRtvENT HANGER ROD SAGS NNKS IN FLEXIBLE DUCT CIU TIE DOWN TO 1 °.X1/16" STRAP>< S (TYPICAL) COMPLY WITH PLE%IBLE DUCT: DO NOT / SAG OR KINK INSULATED, FBCM (2017( 301.12 z" WRAFNSUTATION: r/ UNSTRUT 5uFPLV DUCT THREE SHEET METAL SUPPLY DUCT LUT, FIT E GLUED OVER 5CR£5V5 THROUGH WRAP IN51JUNTION CLG. DIFFUSER HELIX OF FLEXIBLE DUG(. BAND cuMPerAPED SEE PLAN FOR SIZES CEIUNG CEIUNG DIFFUSER RIGID DUCT HANGER AND SUPPORT DETAIL N. T. S. 5-0" MAXIMUM NOTES: METAL STRAP 1). DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL INCHES FROM A CONNECTION BEFORE BENDING, MAXIMUM SAG 1/2" PER FOOT 1-1/2" MIN. 2). SUPPORT SYSTEM MUST NOT DAMAGE DUCT OR OF SUPPORT SPACING CAUSE OUT -OF -ROUND SHAPE. 3), ALL SUPPLY BRANCHES "MUST" HAVE A MIN. OF ° HANGER STRAP 1.5 INCH WIDE (min.) OR 12 ga. WIRE _ 2FT. DISTANCE BETWEEN EACH COWER WHEN ° APPLICABLE. EXCEPT BRANCHES STRAIT PERPENDICULAR ACROSS FROM EACH OTHER. MIN. 4"SLAB (III II BMP CLIP 2X4 GALV. CLIPS PAD AT MIN. 4FLAPRO�IDAUCT APP.# FLEX DUCT FL 14239 TIE DOWN CLIPS APPROVED SMP FLOOD LEVEL ONE CLIP PER CORNER T MAX. FROM END OF UNIYLEVATION BOOT TAP FITTING OR MANUAL BALANCING DAMPER(MVD) SPIN -IN FITTING QUARTER TURN WITH BLADE STOPS. W/AIR SCOOP PROVIDE A HAND LOCKING QUADRANT SEAL ALL JOINTS. THAT EXTENDS APRROX. 1" OFF THE DUCT, PROVIDE WING NUT FOR LOCKING. SUPPORT STRAP MIN. 1-1/2" IN WIDTH PER C.U. MOUNTING DETAIL 5'-0"MIN. SPACING FBC-M SECTION 603.10.3(6) N.T.S. WIRE HANGER SUPPORTING DIFFUSER R FROM ABOVE SUPPLY INSULATED (TYPICAL) DUCT R-6 SHEET METAL DUCT INSULATED DIFFUSER TYPICAL RIGID DUCT SUPPORT INSULATED UCT R-6 CEILING CEILING DIFFUSER TYPICAL DIFFUSER DETAIL SCALE: N.T.S. ALL THREAD ROD TO .PROVIDE CLEANOUT AT EACH CHANGE TOP CHORD OF TRUSSES OF DIRECTION OR EVERY 30' /THREADED CAP 12 GA WIRE SPRING VIBRATION THREADED CAP WITH HANGER (TYP.) ISOLATORS 1/2"0 HOLE DRILLED FROM HVAC UNIT IN TOP - HVAC DET 1 1/2" STRAP @ 5' O.C. MAX DRAIN LINE. SLOPE WITH FLOW SCALE: NTS 1/8"/FT TO DRAIN GUTTER INSULATED FLEX DUCT E F Q � SUPPLY DUCT 0 0 A° Curb ADJUSTABLE Fasten Exhaust Fan units To Curb W/ #12 x 3" Tek Screws MOUNTING FLANGES 3" Off each Corner and 12" o/c in Field 0 CEILING A = FAN SUCTION PRESSURE + 1 INCH (Min. 4") 0 TYPICAL FLEX DUCT SUPPORT EXHAUST GRILLE EXH FAN DETAIL TYPICAL RTU CONDENSATE TRAP DETAIL SCALE: N.T.S. N.T..S. MECHANICAL DETAIL SHEET �p W all I>- N�030 ZEE Wm o a3g M o F e y zTu ccc«c333333 u7S �z�; gS i NF��F-82N W= "L Jo HN V002N�iJi� V !J� V Z � c r C LLI m C LLI = C ` z _Z Z L LI LLI Q � i � � s O to i LL d• G ""�wGUNQ GGENSF No.60102 STATE OF On GENERAL THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK SPECIFIED IN THIS SECTION. PROVIDE ALL LABOR, MATERIALS, SERVICES, EQUIPMENT AND APPLIANCES REQUIRED FOR THE FABRICATION, INSTALLATION, AND/OR RENOVATION OF MECHANICAL SYSTEMS INCLUDING HEATING, VENTILATING, AIR CONDITIONING AND MISCELLANEOUS SYSTEMS AS INDICATED IN DESIGN DRAWINGS AND AS OUTLINED IN THESE SPECIFICATIONS. SCOPE OF WORK FURNISH AND INSTALL COMPLETE AIR CONDITIONING SYSTEMS AS INDICATED ON THE DESIGN DRAWINGS AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE FABRICATION AND/OR INSTALLATION OF THE SCHEDULED AIR CONDITIONING UNITS, EXHAUST FANS, AIR DISTRIBUTION AND DUCTWORK. CLEANING, TESTING AND ADJUSTING: THE MECHANICAL CONTRACTOR, AT HIS EXPENSE, SHALL CLEAN, REPAIR, ADJUST, CHECK, BALANCE, AND PLACE IN SERVICE THE VARIOUS SYSTEMS HEREIN SPECIFIED WITH THEIR RESPECTIVE EQUIPMENT, ACCESSORIES AND PIPING. HE SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS REQUIRED TO PERFORM TESTS REQUIRED BY THESE SPECIFICATIONS AND BY THE GOVERNING AUTHORITIES. NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY INSPECTED AND TESTED. TESTING: ADJUST THE AIR CONDITIONING SYSTEMS, VENTILATING SYSTEMS, FANS, ETC., TO DELIVER NOT LESS THAN THE REQUIRED AIR QUANTITY WITH QUANTITIES IN EXCESS TO BE SUBJECT TO THE APPROVAL OF THE ENGINEER IF FOUND TO NOT HAVE OBJECTIONABLE EFFECTS SUCH AS NOISE, DRAFTS, OR MOTOR OVERLOAD. PRIOR APPROVAL BY THE ENGINEER OF TESTING AND BALANCING CONTRACTOR IS REQUIRED. THIS CONTRACTOR SHALL PROVIDE THREE (3) COPIES OF A TEST AND BALANCE REPORT TO THE ENGINEER AT TIME OF SUBSTANTIAL COMPLETION INSPECTION. THE REPORT SHALL BE PREPARED BY A CONTRACTOR CERTIFIED BY ASSOCIATED AIR BALANCE COUNCIL OR NATIONAL ENVIRONMENTAL BALANCING BUREAU. THE TEST AND BALANCE REPORT SHALL BE TYPEWRITTEN AND CONTAIN THE FOLLOWING DATA: 1. DATE, TIME, WEATHER, WHEN TEST TAKEN. 2. AIR CAPACITIES AT EACH UNIT INCLUDING OUTSIDE AIR. (ENTERING AND LEAVING DB/WB) 3, STATIC PRESSURE THROUGH UNITS AND UNIT COMPONENTS. 4. MOTOR OPERATING VOLTAGE AND AMPERAGE. 5. DRIVE TYPES, SIZES AND SPEED RANGE. 6. IDENTIFICATION OF ALL AIR TERMINAL DEVICES WITH DESIGN CFM AND ACTUAL CFM. ADDITIONALLY, SYSTEMS DRAWING CLEARLY MARKED TO IDENTIFY LOCATION OF EQUIPMENT AND AIR DEVICES TESTED SHALL BE PROVIDED ALONG WITH THE WRITTEN TEST AND BALANCE REPORT. MAINTENANCE MANUALS PROVIDE COMPLETE MAINTENANCE MANUALS (3 REQUIRED) ON ALL NEW EQUIPMENT. ORGANIZE OPERATING AND MAINTENANCE DATA INTO SUITABLE SETS OF MANAGEABLE SIZE. BIND PROPERLY INDEXED DATA INTO INDIVIDUAL, HEAVY-DUTY, 2-INCH, 3-RING VINYL COVERED BINDERS WITH POCKET FOLDERS FOR FOLDED SHEET INFORMATION. MARK APPROPRIATE IDENTIFICATION ON FRONT AND SPINE OF EACH BINDER. INCLUDE THE FOLLOWING TYPES OF INFORMATION. THE INFORMATION WILL BE TURNED OVER TO THE OWNER AT TIME OF SUBSTANTIAL COMPLETION: - OPERATING AND MAINTENANCE INSTRUCTIONS - SPARE PARTS LIST - COPIES OF WARRANTIES - WIRING DIAGRAMS INSPECTION REPORTS AND APPROVALS - SHOP DRAWINGS AND PRODUCT DATA - TEST AND BALANCE INFORMATION TRAINING SERVICES THOROUGHLY INSTRUCT THE OWNER'S REPRESENTATIVE IN THE OPERATION OF ALL EQUIPMENT FURNISHED AND LOCATION OF ALL VALVES AND CONTROL DEVICES. TRAIN BUILDING OWNER'S PERSONNEL DURING NORMAL WORKING HOURS ON STARTUP AND SHUTDOWN PROCEDURES, TROUBLESHOOTING PROCEDURES, SERVICING AND PREVENTATIVE MAINTENANCE SCHEDULE AND PROCEDURES. REVIEW WITH THE OWNER'S PERSONNEL, THE DATA CONTAINED IN THE OPERATING AND MAINTENANCE MANUALS. SCHEDULE TRAINING WITH OWNER, PROVIDE AT LEAST 7-DAYS PRIOR NOTICE TO ARCHITECT/ENGINEER. HANGERS AND SUPPORTS PROVIDE ALL NECESSARY HANGER RODS, CLAMPS AND ATTACHMENTS TO PROPERLY INSTALL AND SUPPORT DUCTWORK, PIPING AND EQUIPMENT FROM THE BUILDING STRUCTURE. PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS REQUIRED TO INSTALL EQUIPMENT, PIPING AND DUCTWORK. ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED, PRIMED AND PAINTED TO PREVENT RUSTING. FINISH COLOR AS SELECTED BY OWNER. THE USE OF BALING WIRE OR PERFORATED METAL STRAPPING IS NOT ACCEPTABLE FOR SUPPORTS. WARRANTY/GUARANTEE: THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE (1) YEAR. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ARCHITECT AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS THERETO. SUBSTITUTIONS EQUIPMENT AND DESIGN OF SYSTEMS INDICATED ON THE DRAWINGS AND WITHIN THESE SPECIFICATIONS SHALL BE CONSIDERED AS "STANDARD OF QUALITY". NO SUBSTITUTIONS SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER. ALL EQUIPMENT SHALL BE NEW UNLESS OTHERWISE NOTED, FREE OF DEFECTS, AS SHOWN ON THE DRAWINGS OR INDICATED IN SPECIFICATIONS. DEVIATIONS FROM SPECIFIED EQUIPMENT AFFECTING ELECTRICAL REQUIREMENTS SHALL BE COORDINATED BETWEEN VENDOR, MECHANICAL CONTRACTOR, AND ELECTRICAL CONTRACTOR PRIOR TO SUBMITTING BIDS. FAILURE TO DO SO WILL NOT BE CAUSE FOR CHANGE OF BID AT A LATER TIME. IN ADDITION, THE MECHANICAL CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR ANY AND ALL CHANGES TO ENGINEERING PLANS REQUIRED BY AUTHORITY HAVING JURISDICTION. APPLICABLE CODES/STANDARDS: - 2017 FLORIDA BUILDING CODE (FBC) - 2017 FLORIDA MECHANICAL CODE (FMC) - 2017 FLORIDA PLUMBING CODE (FPC) - 2017 FLORIDA ENERGY CODE (FEC) - NFPA LATEST EDITION - SMACNA DUCT CONSTRUCTION STANDARDS - ASHRAE - 2014 NATIONAL ELECTRIC CODE (NEC) THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INSPECTIONS AND PAY ALL FEES SHOP DRAWINGS AND SUBMITTALS: SUBMIT SHOP DRAWINGS AND MANUFACTURER'S DATA FOR ALL NEW EQUIPMENT FOR ENGINEER'S APPROVAL PRIOR TO PURCHASE AND/OR FABRICATION. SHOP DRAWINGS FOR EQUIPMENT REQUIRING ELECTRIC POWER OR CONTROL WIRING SHALL INCLUDE COMPLETE WIRING DIAGRAMS. HVAC CONTRACTORS SHALL SUBMIT COMPLETE DUCTWORK SHOP DRAWINGS FOR REVIEW BY THE ENGINEER. SHOP DRAWINGS SHALL INCLUDE COORDINATION WITH GENERAL CONTRACTOR REGARDING EXACT OPENINGS REQUIRED IN EXTERIOR WALLS. THE DUCTWORK SHOP DRAWINGS WILL ONLY BE REVIEWED FOR COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS. DRAWINGS WILL NOT BE CHECKED FOR COORDINATION WITH OTHER TRADES OR BUILDINGS STRUCTURE. IT IS THE RESPONSIBILITY OF THE CONTRACTORS TO COORDINATE AND VERIFY ROUTING AND EXACT LOCATION OF SYSTEM COMPONENTS. SYSTEM IDENTIFICATION PROVIDE IDENTIFICATION LABELS ON OR NEAR EACH PIECE OF MAJOR EQUIPMENT AND EACH OPERATION DEVICE AND DISCONNECT. LABELS SHALL BE CONSTRUCTED OF ENGRAVED PLASTIC LAMINATE SIGN OR PLASTIC EQUIPMENT MARKER PERMANENTLY SECURED TO EQUIPMENT. LETTERING SHALL BE A MINIMUM OF 1/2 INCH HIGH FOR EQUIPMENT NAME AND 3/8 INCH HIGH FOR EQUIPMENT INFORMATION. VALVES SHALL BE TAGGED USING PLASTIC LAMINATE TAGS SECURED WITH BRASS CHAINS INDICATING THE VALVE SIZE, SERVICE AND FUNCTION. EXECUTION: ALL LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC„ INDICATED ON THE DRAWINGS IS DIAGRAMMATIC AND SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE TO THE PLANS SUBJECT TO BUILDING CONSTRUCTION AND INTERFERENCES WITH OTHER TRADES, CONTRACTOR IS RESPONSIBLE FOR ANY FIELD MEASUREMENTS REQUIRED TO PROVIDE AN APPROVED AND FUNCTIONAL INSTALLATION. COORDINATE WITH OTHER TRADES AND FIELD -VERIFY EXISTING CONDITIONS FOR EXACT LOCATION AND ROUTING OF SYSTEMS. PROVIDE OFFSETS, TRANSITIONS AND ADAPTORS AS REQUIRED. NOT ALL COMPONENTS REQUIRED FOR A COMPLETE INSTALLATION ARE SHOWN ON THESE DRAWINGS. REFER TO EQUIPMENT INSTALLATION INSTRUCTION, SCHEDULES AND APPLICABLE CODES FOR ADDITIONAL INFORMATION, INCLUDING REQUIRED CONNECTION LOCATIONS, TYPES AND SIZES. PERFORM ALL WORK NECESSARY TO PREPARE THE STRUCTURE FOR THE INSTALLATION OF THE WORK. ALL HOLES, OPENINGS AND DAMAGED MATERIALS CREATED DURING CONSTRUCTION SHALL BE REPAIRED. ALL PENETRATIONS SHALL BE SLEEVED AND SEALED SO AS TO BE WATER AND AIR TIGHT. PIPING: CONDENSATE DRAINS: CONDENSATE PIPE TO BE TYPE L COPPER OR SCHEDULE 40 PVC. ROUTE AS INDICATED ON PLANS. UNITS 3 TONS AND SMALLER MAY DRAIN TO GRADE, ELSE COORDINATE WITH PLUMBER TO PROVIDE HUB DRAIN(S) IN MECHANICAL ROOM AND DRYWELL(S). HVAC CONTRACTOR TO PROVIDE P-TRAP AT UNIT SIZED FOR 2" GREATER THAN UNIT STATIC PRESSURE. PROVIDE CLEANOUT AT UNIT FOR SUSPENDED HORIZONTAL AIR HANDLERS. INSULATE CONDENSATE PIPE WITH 1/2" ARMAFLEX (OR EQUAL) INSULATION RATED FOR PLENUM APPLICATION. CONDENSATE DRAIN LINE SHALL BE NOT LESS THAN THE EQUIPMENT DRAIN LINE SIZE AND IN NO CASE LESS THAN 3/4" PIPE SIZE. DRAIN LINE SHALL SLOPE A MINIMUM OF 1/8" PER FOOT TOWARDS DRAIN. TERMINATION POINT SHALL BE COMPLY WITH FBCM 2010 SECTION 307.2 REFRIGERANT PIPING: PIPING SHALL BE FIELD FABRICATED ASTM B280 MUELLER STREAMLINE ACR OR READING HARD DRAWN FACTORY SEALED NITROGEN CHARGED SPECIAL REFRIGERATION DUTY COPPER TUBING. FITTINGS SHALL BE MUELLER OR NIBCO WROUGHT COPPER LONG RADIUS REFRIGERATION TYPE. VIBRATION ISOLATION: ALL BLOWER UNITS AND VIBRATING TYPE EQUIPMENT SHALL BE PROPERLY FITTED WITH MASON INDUSTRIES VIBRATION ISOLATION EQUIPMENT SIZED IN ACCORDANCE WITH EQUIPMENT WEIGHT AND DUTY PROVIDE FLEXIBLE CONNECTORS AT ALL SUPPLY AND RETURN CONNECTIONS TO AIR HANDLING EQUIPMENT CONSISTING OF HEAVY CANVAS OR NEOPRENE FABRIC WITH AIRTIGHT SEAMS AND CONNECTIONS TO THE EQUIPMENT. AIR FILTERS: FILTERS SHALL BE 1" FIBERGLASS MEDIA THROW AWAY TYPE IN A RIGID FRAME WITH A SUPPORTING MAZE ACROSS BOTH ENTERING AND LEAVING SURFACES. SUPPLY ONE COMPLETE SET OF FILTERS AFTER OWNER'S FINAL ACCEPTANCE. FARR 30/30 OR EQUAL. DUCTWORK: ALL DIMENSIONS ARE INSIDE NET FREE AREA. MATERIALS: LOW PRESSURE SUPPLY AND RETURN DUCTWORK SHALL BE FIBERBOARD EQUAL TO MANSVILLE FR-800 (SUPERDUCT). PROVIDE MINIMUM "R" VALUE OF 4.2 FOR DUCTS INSTALLED IN CONDITIONED SPACE AND 6.0 FOR DUCT INSTALLED IN UNCONDITIONED SPACE. DUCTWORK SHALL BE LINED WITH ANTI MICROBIAL COATING. SEAL ALL JOINTS WITH GLASS FABRIC AND MASTIC. TAPE ALONE IS NOT ALLOWED. MEDIUM PRESSURE DUCT SHALL BE STEEL SHEET METAL. GENERAL EXHAUST DUCTS SHALL BE GALVANIZED OR STAINLESS STEEL SHEET METAL. WET EXHAUST DUCTS SHALL BE ALUMINUM OR STAINLESS STEEL SHEET METAL ADJUSTABLE SPUTTERS AND DAMPERS SHALL BE INSTALLED IN EVERY SPLIT AND BRANCH DUCT AND SHALL BE PROVIDED WITH LOCKING QUADRANTS ON EXPOSED OR IN ACCESSIBLE AREAS OF THE DUCT FOR EASE OF OPERATION. ACCESS PANELS OR YOUNG REGULATORS SHALL BE PROVIDED WHERE DAMPERS ARE INSTALLED ABOVE HARD CEILINGS OR IN SOFFITS. ELBOWS OR CHANGES IN DUCT DIRECTION GREATER THAN 45 DEGREES SHALL BE FITTED WITH AIR TURNS CONSISTING OF CURVED AIRFOIL BLADES OR VANES WHICH WILL PERMIT THE AIR TO MAKE ABRUPT TURNS WITHOUT APPRECIABLE TURBULENCE.. FLEXIBLE DUCTWORK SHALL BE ACOUSTICAL LOW PRESSURE TYPE WITH INTERIOR LINER, METAL HELIX, FIBERGLASS INSULATION WITH AN R-VALUE OF 6.0 OR GREATER, AND COPOLYMER SEAMLESS OUTSIDE SLEEVE. THE ENTIRE FLEXIBLE DUCT ASSEMBLY SHALL BE LISTED IN ACCORDANCE WITH UL-181 CLASS 1 AIR DUCT MATERIAL. THE MAXIMUM LENGTH OF ANY FLEX DUCT SHALL BE 7'-0". FLEXIBLE DUCTWORK SHALL MEET THE FLORIDA MODEL ENERGY EFFICIENCY CODE. ALL JOINTS AT CONNECTIONS TO DIFFUSERS AND DUCTWORK SHALL BE SEALED WITH GLASS FABRIC AND MASTIC. INSTALL DUCTWORK INDICATED ON DRAWINGS, MAKING NECESSARY CHANGES IN CROSS -SECTIONS AND OFFSETS, WHETHER OR NOT SPECIFICALLY INDICATED. SPIRAL DUCTWORK SHALL BE SIMILAR TO "SEMCO" MODEL SL(85)P LOW PRESSURE. PROVIDE U.L.LISTED FIRE,SMOKE OR COMBINATION FIRE SMOKE DAMPER IN ALL PENETRATIONS OF RATED SURFACES PER APPLICABLE CODE AND IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND THE U.L. LISTING REQUIREMENTS. INTERLOCK THE UNIT WITH FIRE ALARM SYSTEM. INSULATION: WORKMANSHIP ON THESE SYSTEMS MUST BE GOOD, AND CLEANLINESS OF PIPING SYSTEMS IS SHALL BE AS MANUFACTURED BY CERTAINTEED, OWENS-CORNING, MANVILLE, PITTSBURGH CORNING, MANDATORY. WORK THAT DOES NOT MEET THESE CRITERIA SHALL BE REMOVED AND REPLACED AT NO ARMSTRONG, OR APPROVED EQUAL. INSULATION SUNDRIES AND ADHESIVES SHALL BE AS MANUFACTURED COST TO THE OWNER. THE ENGINEER SHALL DETERMINE WHETHER THE WORK MEETS THESE CRITERIA. BY BENJAMIN FOSTER, CHILDERS, VIMASCO, OR APPROVED EQUAL. ALL INSULATION SHALL BE SUITABLE FOR INSTALLATION IN A RETURN AIR PLENUM. COVER ALL EXPOSED LIQUID LINES AND ALL SUCTION PIPING (INDOORS AND OUTDOORS), FITTINGS, VALVES, ETC., CONTINUOUS THROUGH SLEEVES, HANGERS, ETC., WITH 3/4" FR/ARMAFLEX. INSTALLATION SHALL BE CONDENSATION FREE AND INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. PAINT ALL INSULATION EXPOSED TO OUTDOORS WITH UV PROTECTIVE PAINT PER MANUFACTURERS RECOMMENDATIONS. REFRIGERANT PIPING BELOW GRADE SHALL BE ROUTED THROUGH MINIMUM 4" DIAMETER PVC PIPE SLEEVES TO EACH CONDENSING UNIT. ALL UNDERGROUND REFRIGERANT PIPING SHALL BE CONTINUOUS SOFT DRAWN TUBING WITH NO UNDERGROUND JOINTS ALLOWED. REFRIGERANT PIPE SIZES SHALL BE SIZED PER MANUFACTURER'S RECOMMENDATION BASED ON LENGTH OF RUN BETWEEN CONDENSING UNITS AND AHU'S. INSULATE ALL SHEETMETAL DUCTWORK EXCEPT EXHAUST DUCTWORK EXTERNALLY WITH MANVILLE R SERIES MICROLITE TYPE 75 OR 100 INSULATION OR APPROVED. INSULATION TO HAVE TYPE II FSK FACING AND UL FIRE HAZARD CLASSIFICATION OF FLAME SPREAD 25/SMOKE DEVELOPED 50/FUEL CONTRIBUTED 50. INSTALL INSULATION PER SMACNA, FLORIDA MODEL ENERGY EFFICIENCY CODE AND MANUFACTURER'S RECOMMENDATIONS. ALL INSULATION JOINTS SHALL BE SEALED WITH GLASS FABRIC AND MASTIC. MINIMUM INSULATION REQUIREMENTS AS FOLLOWS: - SUPPLY AND RETURN AIR UNCONDITIONED: 2" (R-6 MIN) - OUTSIDE AIR: 2" (R-6 MIN) PIPING ROUTED ALONG BUILDING EXTERIOR WALL SHALL BE PROTECTED BY SHEET METAL HOUSING PROVIDE ALL EXTERIOR INSULATION DUCTWORK OR PIPING EXPOSED TO THE OUTDOORS WITH A MINIMUM SECURELY ATTACHED TO WALL AT 8'-0" INTERVALS AND PAINTED TO MATCH BUILDING EXTERIOR. 8 MIL THICK ALUMINUM OR PVC JACKET. TRAP OIL IN SUCTION LINE AT EVAPORATOR COIL NO OTHER COIL TRAPS PERMITTED. PROVIDE SUCTION RISERS, CHECK VALVES, SOLENOID VALVES, OR OTHER DEVICES REQUIRED IN PIPING SYSTEM BY MANUFACTURER'S INSTALLATION INSTRUCTIONS. FURNISH ALL LABOR AND MATERIALS TO REPLACE REFRIGERANT LOST DURING THE ONE YEAR WARRANTY PERIOD. PIPE HANGERS AND SUPPORTS: PIPE HANGERS, WHERE NEEDED, SHALL BE GRINNEL #260 CLEVIS TYPE, 5'-0" ON CENTER, SECURELY ATTACHED TO BUILDING CONSTRUCTION. SPACE AT MIN, 5'-0" INTERVALS. PIPE SUPPORT: ATTACH LINES SECURELY ALONG PAD/FLOOR/EQUIPMENT/STRUCTURE TO PREVENT MOVEMENT. SUPPORT IN A MANNER THAT LINES DO NOT HANG FROM EVAPORATOR CONNECTIONS OR BLOCK ACCESS TO FILTERS, CONTROLS, ETC. SUPPORT AT MIN. 8'-0" INTERVALS FOR VERTICAL PIPES, 5'-0" FOR SUSPENDED HORIZONTAL PIPING. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ADEQUATE AND PROPER INSULATION AND MOISTURE -SEAL IN A MANNER THAT WILL PERMANENTLY PREVENT THE ACCUMULATION OF ANY OBJECTIONABLE MOISTURE ON THE EXTERIOR OF AIR CONDITIONING UNITS, REFRIGERANT PIPING, CONDENSATE DRAIN PIPING, AIR DUCTS OR OTHER PARTS OF THE SYSTEM. CONTRACTOR SHALL CORRECT THE CAUSE OF ANY CONDENSATION AND FULLY REPAIR, WITHOUT COST TO THE OWNER, ANY DAMAGES TO BUILDING SURFACES, FURNISHINGS OR EQUIPMENT CAUSED BY CONDENSATION FROM THIS SYSTEM, FOR THE FULL PERIOD OF GUARANTEE. CONTROLS: FACTORY MOUNTED CONTROL SHALL BE PROVIDED TO ACCOMPLISH THE SEQUENCE OF OPERATION. ALL INTERIOR CONTROLS SHALL BE FACTORY FURNISHED AND INSTALLED. PROVIDE ALL 24 VOLT WIRING BETWEEN CONTROL DEVICES AS NECESSARY TO MAKE COMPLETE AND OPERATION SYSTEM. PROVIDE 110/24 VAC TRANSFORMERS AS REQUIRED. COORDINATE WITH DIVISION 16 FOR 120V POWER ROUGH -IN, CONTROL, POWER AND WIRING. 24 VOLT WIRING SHALL BE PLENUM RATED CABLE. AIR CONDITIONING UNITS (OX SPLITS UNITS SHALL BE SPLIT SYSTEM AIR-TO-AIR ELECTRIC AIR CONDITIONING UNITS AND HEAT PUMPS AS SCHEDULED ON DRAWINGS. UNITS WITH INTEGRAL ELECTRIC RESISTA NCE HEATERS SHALL HAVE A SINGLE -POINT ELECTRIC CONNECTION. TOTAL COOLING CAPACITY OF THE UNITS SHALL BE AS SCHEDULED ON DRAWINGS. UNIT CABINET SHALL BE CONSTRUCTED OF GALVANIZED STEEL, BONDED AND COATED WITH BAKED ENAMEL. CABINET INSULATION SHALL COMPLY WITH FLORIDA ENERGY CODE. FANS AND MOTORS - THE INDOOR AIR FANS SHALL BE OF THE FORWARD -CURVED CENTRIFUGAL CLASS 1 TYPE. MOTOR AND DRIVE TO PROVIDE HIGHER FAN OUTPUT WHEN JOB REQUIREMENTS EXCEED STANDARD FAN CAPACITY SHALL BE PROVIDED. COOLING SYSTEM SHALL BE PROTECTED BY LOSS OF CHARGE PROTECTION, HIGH AND LOW PRESSURE SENSORS, COMPRESSOR MOTOR OVERLOADS, AND A TIMING DEVICE WHICH WILL PROHIBIT THE COMPRESSOR MOTOR FROM BEING SUBJECTED TO A STARTING CURRENT MORE THAN ONCE EVERY FIVE MINUTES. HEAT PUMP/CONDENSING UNIT INSTALLATION: PROVIDE CONCRETE PADS FOR GRADE MOUNTED CONDENSING UNITS. PADS SHALL BE A MINIMUM OF 4" THICK, 3,000 PSI CONCRETE, AND SHALL BE 4" LARGER ON EACH SIDE THAN THE FOOTPRINT OF THE CONDENSING UNIT. VERIFY UNIT DIMENSIONS WITH APPROVED SHOP DRAWINGS PRIOR TO FABRICATION OF PADS. EXHAUST FANS: FURNISH EXHAUST FANS WITH PERFORMANCE AND CAPACITIES AS LISTED ON THE DESIGN DRAWINGS, COORDINATE WITH ARCHITECT TO LOCATE EXHAUST FANS, EXHAUST GRILLES, WALL OR ROOF CAPS A MINIMUM DISTANCE OF 10'-0" FROM ANY OPERABLE WINDOW, DOOR OR FRESH AIR INTAKE. AIR DISTRIBUTION EQUIPMENT: FURNISH SUPPLY AIR GRILLES AND RETURN AIR REGISTERS WITH OPPOSED BLADE BALANCING DAMPERS AS SCHEDULED ON THE DESIGN DRAWINGS. GRILLES, REGISTERS, AND CEILING DIFFUSERS SHALL BE FURNISHED AS SCHEDULED ON THE DESIGN DRAWINGS AND SHALL BE ALL ALUMINUM CONSTRUCTION UNLESS NOTED OTHERWISE. AIR DISTRIBUTION SHALL NOT EXCEED NC-30 NOISE CRITERIA AS DEFINED IN THE LATEST ASHRAE GUIDE. MECHANICAL SPECIFICATION SCALE: NTS W V NN00a z�laogoZ WW o O]zp O �Up, oaq? $ 3.06 _ ¢ &— nV0 W U a q V• =I`u E z V1LL �OF=32.���C�ZU 3 mp��a3�U,�6{s< g4wz �KwKn"JrcJ Wp>>p2l'JmJ _90'F=NFI�N(J�1� C� 0 O H on 0 V J J li d' G W m M W r. �" � Z is Z A. LL W E cc 0 cc m O LLf) i L6 � a° ;•��GENS�. SQ a �+i No.60102 STATE OF i \\\��\1111111111///i o :c 0 it Uo Z Cu k\\\L LU 11Lu Tm - __ �2• cw _- I-_ l 1•NW 7 I IN 1 CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM 9�-, e•cw 729 W TV 2•NW su •cw ..-�_ DRAM DRAIN L N4' I2•^i GIRL'S MUSIC I0cw t� Cw I I CORRIDOR CORRIDO i CLASSROOM CORRIDOR CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM RESOURCE CLASSROOM CORRIDOR _ I 12 CW I i I� • I� I I I I I 1 —L-ll7 CdN I _____________________ MR_____________________________________________________________________________________.0 REO-Aff-A_______--_---______________----lwm _-iiwj---------p--------T.-.7-------- --------51. i I I tWml I I 1 I WW ------ I I I I ! IxK x �L xxx XXXXXXXXJCXXxxxx XJCxC x-i------YX-Y-AI----- COURTYARD COVERED AREA s; JANITOR DATA/ ELECTRICAL InnCORRIDOR � CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM I i CORRIDOR CORRIDOR CORRIDOR I cw trz• I a, DIN 1 FLOOR if FLOO \\ J DRAIN DRAIN aeirg'e ART COMPUTER LAB cw� w 0 DOan• cw0 CLASSROOM 34• acw CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM T I , YXXXXXYXXX:L axx xx.zx xxzxxzzxxxzxxx %X XXXXXXXXXXYXYXXXXX I< I 0 W S�S UOS �00 C7 m N Z Z 0Ow z conir Z000 20(= D Z X 0 UoI-w ¢ 0 W ¢with Z 0 w P J W Z �N Z-~ W In WI- OW W- w LJ W O U Z r U W 0 z 0 Z 0ozz ZOO N SO05 UW In H LL 0 W 0j U� W02= O ❑ I- 1- 0 co LU H LU O a 0 U Q I..L !— Z O U O J LL cl m H PLUMBING PLAN PL001 SCALE: 3/32" = V-0" DRAWN BY: W.J.S. REVISION 1: DATE REVISION2: DATE PLC SCALE: 3/32" = V-0" _z CLEAR FLOOR SPACE Y 60" MIN CLEAR co FLOOR SPACE / 30" MIN. WATER CLOSET CLEAR FLOOR SPACE_ _ N.T.S I � I I GEAR FLOOR SPACE I, 30 min I, FLAN VIEW NI—LO DRINKING; FOUNTAIN DETAIL N.T.S BATHROOM EQUIPMENT LEGEND Ir-11' SOAP DISPENSER HAND DRYER NON ACCESSIBLE TOILET FD W/ GREASE 4" SANITARY LINE TABLE 604.4 MAXIMUM FLOW RATES AND CONSU PLUMBING FIXTURES AND FIXTURE PLUMBING FIXTURE OR FIXTURE FITTING LAVATORY, PUBLIC, (METERING) 0.25( LAVATORY, PUBLIC, (OTHER THAN METERING) URINAL SINK FAUCET 1.0 G WATER CLOSET 1.6 GI WATER 1. ALL WATER PIPING TO BE SCHED 40 CPVC. 2. PROVIDE ISOLATION VALVES TO ALL PLUMBING FIXTURES INSTALLI 3. PROVIDE BACK FLOW PREVENTION DEVICE TO ALL EQUIPMENT WA 4. COLD WATER ONLY. 5. NO UNDER SLAB JOINTS IN WATER PIPING. 6 FD PROVIDE ISOLATION VALVES TO CW AND HW FOR MOP SINK. 7 PROVIDE WATER HAMMER ARRESTOR TO ICE CUBER MACHINE. A AI ITA DV ALL DWV SANITARY LINES TO BE SCHED 40 PVC. ALL WORK SHALL COMPLY WITH FBC 2017 ,6TH EDITION, PLUMBING. W/GREASE TRAP ISOMETRIC SEWER LINE DIAGRAM N.T.S. "w ?� / • � • N .... LL •.�. � :0 0 o J" :Z G W W ro 'I'r- O 1 i ¢- v ;V1'•,� z (D ki '////III 11111\\\\\\\\\ 7 (D z 0 J m w = 0 a = z F�o� 0 U) o E 2 H Z o LL o (D U) L r (7 W ZZ O DDw J z N d' W m2 m Q = LL co H t Y 0- 0 m LL j Z U` o K D U ZO H K W z zaw0z Jaz (D Of w W 0< z o a w c W Z Jw J = �W Z<n LL o� W o W1.- 0 w a F m WI-cnz w� m � I -In ow FD LL w zo ¢0Ozz zX2oz wC.) > z L5 IS 00 m (D LL -Fn T C) U W W Z q 0 J W U< U)(n E0 z H W 75 Z K U_=OF IL R W� = V U) w W 0 2 2 W 0 m J - 00 1- H I- LL l� WCD 1'�11 O � W O aO z 0 W Q r� T \ J LL m w It 0 fs cl H � U W O w � O � a SRAM PLUMBING ISOMETRIC & LEGENDS DRAWNBY:DESIGNW. S. -- DESIGN DATE: 10/24/2018 00 SCALE: 1/4"=1'-O" REVISION I: DATE SHEET: REVISION 2: DATE PL00, SCALE: 1/8" = V-0' TOP ELEV. OF FLOOR DRAIN FINISHED FLOOR 4 PROVIDE TRAP PRIMER CONNECTION AS REQUIRED P—TRAP MINIMUM 3/8" ALL THREADEC PLUMBING PIP INSULATED a NOT TO SCALE FLOOR DRAIN WITH ADJ. BRASS STRAINER SLOPE a MAX. 12'-0" FLOOR DRAIN (FD)DETAIL SCALE: NTS ASSEMBLY 5 JCTURE ABOVE ROOF INSULATION II II III III III ill PROVIDE SLEEVE IF --A REQUIRES BY TYPE OF ROOF DECK 2" VENT MINIMUM 12° BELOW ROOF, 4" WASTE 1/8" SLOPE MIN. PER FOOT 6" THICK BY 18" SQUARE CONC. PAD. PROVIDE PIPE INCREASER — WHERE REQUIRED TO MAKE MINIMUM 3" VENT THRU ROOF. PROVIDE ONE PIECE SPUN ALUMINUM BA',E WITH, GRADUATED STEPPED PVC- BOOT, AND ADJUSTABLE STAINLESS STEEL CLAMPS, SET BASE IN BED OF MASTIC. MINIMUM 12" ABOVE ROOF ROOF DECK ANCHOR PIPE TO ROOF DECK OR JOISTS WITH U-BOLT AROUND PIPE AND ANGLE IRON WELDED OR SCREWED TO DECK OR JOIST, HUBLESS PIPE CONNECTORS ON CAST IRON PIPE OR PVC. REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VENT THRU ROOF MINIMUM TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE. PROVIDE 1" FIBERGLASS INSULATION WITH ALL -SERVICE JACKET ON VENT PIPE INSIDE BUILDING WITHIN SIX FEET OF VENT THRU ROOF LOCATION. VERIFY FLASHING AND COUNTER FLASH WITH ROOFING CONTRACTOR. VENT THRU ROOF (VTR) DETAIL NOT TO SCALE "CO" TO BE PVC IN COVER. PVC SCH 40 CLEANOUT WITH COVER FOR DUTY REQUIRED. GRADE FINISHED FLOOR 7 r PVC EXTENSION B—LINE FIG. 83060 SAME SIZE Q AS SEWER UP � TO 4" DIA. PVC LONG SWEEP ADJUSTABLE 1/4" BEND OR PVC PIPE HANGER COMB, "Y" & 1/8" BEND. RING (USE REDUCING TYPE WHERE REQUIRED._ B—LINE FIG. B3170 PVC EXTENSION SAME SIZE AS SAN WASTE UP TO 4" DIA. BUILDING DRAIN OR A 'DIRECTION OF FLOW SEWER MATERIAL AND SIZE AS SPECIFIED. EXTERIOR CLEANOUT (ECO) INTERIOR FLOOR CLEANOUT (HEAVY TRAFFIC AREA) CLEANOUT (CO) DETAILS SCALE: NTS FCO C Plumbing General Notes FINISHED FLOOR(SEE ARCHITECTURAL DRAWINGS FOR FLOOR SLOPES) _., SLOPE ADJUSTABLE DRAIN HEAD DRAIN BODY P-TRAP CONNECTION P-TRAP FLOOR DRAIN DETAIL FLOOR SINI AIR GAP = TWICE THE PIPE DIAMETER DOME WASTE STRAINER INDIRECT DRAIN CONNECTION DETAIL N.T.S FLOW TO FIXTURE AUTOMATIC TRAP PRIMER VALVE MOUNT IN CW SUPPLY LINE OF FREQUENTLY USED FIXTURE NEAR FLOOR DRAIN(_S) SUPPLIED J a AND SHALL COMPLY WITH SECCTION 1002.4 OF FBCP. z 1/2" COPPER TUBING - RUN UNDERFLOOR TO FLOOR DRAINS) FLOOR SLAB FLOOR DRAIN (SEE PLANS) a da a ill' 11111111111tH11111 - d 4 d a a a d TRAP PRIMER CONNECTION (1 IN FLOOR DRAIN I l I TYPICAL FOR ALL FLOOR DRAINS FD UNLESS NOTED OTHERWISE ON DRAWINGS TRAP PRIMER (TPV) CONNECTION DETAIL NOT TO SCALE TRAP PRIMER VALVE (MAXIMUM OF 8 DRAINS) "PRECISION PLUMBING PRODUCTS" \ " TYPE "K" SOFT SEAMLESS COPPER WITH NO JOINTS BELOW FLOOR SLAB. SLOPE AT W" PER FOOT MINIMUM TO FLOOR DRAIN CONNECT'^"' FLOOR DR) 1: Coordinate All Pipe Routing With All Other Trades Prior To Installation. Encountered In Field. Mounting Heights, Dimensions, and Handicapped Requirements. Back flow Prevent Complying With The Requirements Of The Standard Route All Piping To Avoid Ductwork, Electrical Raceways, and Building Plumbing Code; Table 608.1. Structures. 7: All Plumbing Installation and Materials Shall Be In Strict Accordance 14: Position Roof Drains at Low Points. For Exact Location See Architectural If Penetrations Through Structural Members Are Required For Plumbing With All Local, State, and Federal Codes and Applicable Standards, Drawings. 22: All Water Piping Installed in Exterior Walls Shall Be Placed On The Installations, Regulations, and Authorities Having Jurisdiction Over The Project. Interior Side Of The Wail, The Wall Insulation Shall Be Placed On The Notify Architect and Structural Engineer Prior To installation To Ensure That 15: Plumber Shall Be Licensed By State And Local Authorities To Install Exterior Side Of The Piping. Structural 8: Provide Access Panels To All Valves Within Chases or Above Natural Gas Piping. Integrity is Maintained. Non -Accessible Ceilings. Refer To Architectural Drawings For Ceiling Types. 23: Pressure Reducing Valves Shall Be Installed On Branch Lines Serving 16: Verify Invert Elevations and Exact Locations Of Sewers To Which New Fixtures And/Or Equipment When The Pressure In The Line Exceeds 60 P.S.I. 2: This Contractor Shall Base His Proposal Upon The Equipment As 9: Install Water Hammer Shock Arrestors At Each Fixture or Battery Of Sewer Lines Are To Be Connected Before Installation. It Is Recommended That A Velocity Between 5 and 8 Feet Per Second Be Scheduled Or Specified, Fixtures Where Required. Arrestors Shall Be Factory Fabricated. Install Maintained. Using The Manufacturers and Model Numbers as Called For In The Arrestors and Size Per Plumbing and Drainage Institute Standard P.D.I. 17: All Vents Through Roof Shall Be A Min. 10'-0" From Any Air Intakes. Specifications and WH-201. Accepted Manufacturers, Sioux Chief, Josam, Jay R. Smith, Watts 24. Do Not Penetrate Wall Footings With Piping. Coordinate With General Scheduled on The Drawings. (NO.15 Series), Wade. Air Chambers Are Not Acceptable. 18: Plumbing Contractor Shall Install Dielectric Unions At All Connections Of Contractor To Drop Footing For Sleeved Stem Wall Penetrations As Required Dissimilar Metals. To Clear Plumbing Services Where Absolutely Necessary. 3: The Contractor Is Expected To Order All Materials In Sufficient Time To 10: Site Connections Shall Be Provided On Civil Site Utilities Drawings. All Avoid Delaying Services Shown On This Set Of Plans Terminate 5'-0" From Building, Unless 19: Rough -In All Wastes And Supplies To Special Equipment In Strict 25: Fixture P-Trap Distance From Fixture Outlet To Trap Weir Shall Not The Completion Of The Project. Delay In Deliveries Will Not Be Considered a Shown Otherwise on Drawings. This Contractor Shall Make All Final Plumbing Accordance With Manufactures Recommendations And Make Final Exceed 24 Inches. Justifiable Reason For Submission Of Substitute Materials. Service Connections To Site Work Utilities. Connections. All Supplies Shall Be Valved. Install Vacuum Breakers Where Required By Code. 26: Plumbing Contractor Shall Install Horizontal Combination Waste And Vent 4: Route All Piping Concealed Above Ceiling, Within Walls, or In Chases 11: Drainage Piping Shall Slope No Less Than 1/8" Fall Per Foot. See Systems In Strict Accordance With 2017 Florida Building Code Plumbing Except as Specifically Noted, or In Mechanical Rooms. Piping Shall Not Be Specifications. 20. Submit Shop Drawings ( Including Pipe Routing and Equipment Location) Edition. Run Thru Electrical Rooms or Closets. To Architect/Engineer For Review Prior To The Installation or Purchasing Of 12: Furnish and Install Hose Bibbs and Wall Hydrants 24" Above Finished Any Piping And/Or Equipment. 27: Any Piping In Unconditioned Spaces Shall Be Fully Insulated And 5: Sleeve and Fire Stop All Penetrations Of Rated Walls, Ceilings, Floors, Grade/Floor And Proved Vacuum Breakers as Shown on Drawings With Protected From Freezing Temperatures. Etc. IAccordance With Applicable Standards and Local Codes To 150' Minimum Perimeter Intervals. 21: Provide 'Minimum Air Gap' as Defined In ANSI A112.1.2 For All Water Maintain Rating. See Specifications. See Architectural Drawings For Rated Distribution System Outlets. Where It Is Not Possible To Provide e Absolutely No PVC or CPVC Piping Will Be Allowed In Return Air Walls and Floors. 13: See Architectural Drawings For Exact Plumbing Fixture Locations, Minimum Air Gap, The Outlet Shall Be Equipped With An Accessible Plenums. Plenums. 6: Pipe Routing Shown Is Schematic and Is Intended To Indicate General 29: Indirect Waste Per FBCP 2017 802.1.1 And 801.2. Routing. Plumbing Contractor Shall Provide Any Additional Offsets and Fittings Required For Proper Installation and To Maintain Clearances As PLUMBING DETAIL SHEET TRAP PRIMER SCALE: NTS IN 0 J J Z d T O 00 W m CO) D _Z 0 W gi E a ONJ LO L 0 L6 -tr a. X\01uu1nini,,� GUNDOC',% .`�c��: ��GENSF..S02 * : No.60102 -n'•. STATE OF H � L Q H