Loading...
HomeMy WebLinkAboutCONSTRUCTION PLANS PAGE 1-13S E P A R A T E P E R M I T S R E Q U I R E D ALL FIRE PROTECTION SYSTEMS, FUEL, GAS, SIGNAGE AND OTHER BUILDING COMPONENTS REQUIRED BY LOCAL BUILDING AND FIRE AUTHORITIES TO BE INSTALLED OR MODIFIED VIA SEPARATE PERMIT, AND WHICH ARE AFFECTED BY THE WORK PROPOSED HEREIN, SHALL BE DULY INSTALLED OR MODIFIED ONLY THROUGH SEPARATE PERMIT AUTHORIZATION FROM THE AUTHORITY(S) HAVING JURISDICTION. ® COVEREDAREA- �� 0 0 - -. OFFICE OFFICE OFFICE OFFICE ' O O O ADMIN WAITING A- A-11Uojj A-1 A-11 A- O O CONF -0 0 O-LOUD CLINIC 0 A-12 � O O � O O A-012 O 3 F i�, A_12 ' TAF 1 T �I Ap ES, INIC'R T Do 0 ®; A-11 0; o o O' O F.07CI 1 I 0 I H ' 1 CAFETORIUM Q- ---- _�_- - � - _r-0-1 II 1-0 I I - A 4A © \LPJF STORAGE RESOURCE -A-18 A-17 1 GENERAL LIGHTING SCHEDULE NOTES. 1. MANUFACTURERS 8 NUMBERS ARE LISTED TO ESTABLISH QUALITY ONLY AND NOT TO LIMIT COMPETITION. TEN DAYS PRIOR TO BIDDING, SUBSTITUTIONS ARE ALLOWED SUBJECT TO SUBMITTAL DATA, PHOTOMETRICS 8 ENGINEERS APPROVAL AS REQUIRED BY SPECIFICATIONS - 2. ALL FIXTURES TO BE U.L. LISTED. ALL EXTERIOR FIXTURES SHALL HAVE U.L. WET LABEL OR DAMP LABEL AS REQUIRED BY LOCATION, CONTRACTOR SHALL VERIFY BEFORE INSTALLING FIXTURE. 3, CONTRACTOR SHALL PROVIDE ALL MOUNTING ACCESSORIES, BAR HANGARS B HARDWARE TIEQUIRED FOR A COMPLETE SYSTEM. 4. CONTRACTOR TO COORDINATE AND DETERMINE EXACT MOUNTING HEIGHTS OF ALL INTERIQR AND EXTERIOR WALL MOUNTED LIGHT FIXTURES IN FIELD PRIOR TO ROUGH -IN. FIXTURES TO BE UNIFORM AND CONSISTENT IN ALL APPLICATIONS. 5. IN ADDITION TO EXIT SIGNS SHOWN ON THE ORAWNGS, THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL (25) ADDITIONAL EXIT SIGNS AT THE DISCRETION OF THE ARCHITECT/ENGINEER, THE OWNER, AND/OR THE LOCAL BUILDING OFFICIAL. FOR BIDDING PURPOSES, ASSUME A 109 RUN OF 2#12. #12G-3/4"C ALONG WITH LABOR FOR INSTALLATION (PER SIGN). FIXTURES NOT USED SHALL BE TURNED OVER TO THE OWNER. 6. EMERGENCY BATTERY LED DRIVERS SHALL CONTAIN INTEGRAL SENSING CIRCUIT TO ALLOW FIXTURE TO BE SWITCHED WITH AREA FIXTURES FOR NORMAL OPERATION WHERE INDICATED, AND ENERGIZE BATTERY POWERED LEDS, EQUALLY UPON LOSS OF POWER CIRCUIT, REGARDLESS OF SWITCH POSITION. MANUFACTURER SHALL BE IOTA OR BODINE EQUAL. LIGHTING FIXTURE SCHEDULE FIXTURE FIXTURE MANUFACTURERS LAMPS FIXTURE VOITAG TYPE DESCRIPTION WATTAG UNIVERSAL MOUNTED EXIT SIGN WITH RED LED ® EXA ON WHITE THERMOPLASTIC HOUSING, DIFFUSER EMERGI-CITE: E1_X490.RN LED 5 UNV LENS, SPEC GRADE. (NOTE:5) UNIVERSAL MOUNTED DUAL EMERGENCY HEADS EXB EXIT SIGN W/ RED LED ON WHITE THERMOPLASTIC EMERGI-LITE'. ELXN4MRN LED 5 UNV HOUSING, DIFFUSER LENS, SPEC GRADE. 4', 5000 LUMEN, 35K TEMP., LED STRIP LIGHT, IA IA 22 GA. STEEL, ALL PARTS PAF, WIRE GUARD, WILLIAMS. 75R-0 L501835-DRV-UNV LED 44 UNV NON -DIMMING. (FIXTURES IN THE GYM PLATFORM SPACE SHALL BE BLACK IN COLOR) IAE ® IAE SAME AS'IA' ABOVE EXCEPT WITH INTEGRAL WILLIAMS. 75RA4_501835-DRV-UNV-EM/10WLP LED 44 UNV SWITCHED 90 MINUTE BATTERY BACK-UP. SA SURFACE MOUNTED CANOPY LIGHT FIXTURE, Q SA 2500 LUMEN LED, WHITE METAL HOUSING, KENALL: MS11FO-PP-MW-20L35K-OV LED 24 UNV UV RESISTANT LENS, UL WET LOCATION. SAME AS'SN ABOVE EXCEPT WITH INTEGRAL SAE SWITCHED W MINUTE BATTERY BACKLP. SAE FIXTURE SHALL COME ON IN THE EVENT OF A KENALL'. MS11 F0-PP-DB-201_WK-0V-EM LED 24 UNV POWER OUTAGE REGARDLESS OF CONTROLS POSITION. JI77�gg��� RECESSED 2X4, ARCHITECTURAL TROFFER, TA 6400 LUMEN LED, METAL HOUSING, FROSTED WILLIAMS' LT-241_64 135-AF-DIM-UNV LED 49 UNV IJ ACRYLIC CENTER SHIELDING, DIMMABLE, MITE - PAINTED AT THE FACTORY. TAE TAE SAME AS'TA' ABOVE EXCEPT WITH INTEGRAL 90 WILLIAMS: LT-24-1_ 4835-AF-DIM-UNV-EM/10W LED 49 UNV ® MINUTE BATTERY BACK-UP. TS RECESSED 2X4, ARCHITECTURAL TROFFER, TB 5200 LUMEN LED, METAL HOUSING, FROSTED WILLIAMS: LL24L5ZB3&AF-DIM-UNV LED 37 UNV ACRYLIC CENTER SHIELDING, DIMMABLE, WHITE Ud PAINTED AT THE FACTORY. TBE TBE SAME WITH INTEGRAL 90 WILLIAMS: LT-24-DIM-0IM-UNV-EMMOW LED ® MINUTE BATTERY BACK -EXCEPT MINUTE BATTERY BACK-UP. TC RECESSED 2X2, ARCHITECTURAL TROFFER, TC 4" LUMEN LED, METAL HOUSING, FROSTED ACRYLIC CENTER SHIELDING, DIMMABLE, WHITE WILLIAMS' LTO 22-L491W5-AF-0IM-UNVLED r37UNV UNV PAINTED AT THE FACTORYWALL MOUNTED SECURITY LIGHT FIXTURE, 8000 WP LUMEN LED, BRONZE METAL HOUSING FIDELUX: FWPFG80W35K-0NV LED UNV UV RESISTANT LENS, UL WET LOCATION. -- - - iEM oB go_ i • i d ••• 0 0' •• I� d -•• �' �'aLAS •••� �' •• ID -•E� ••�, Q ••• � oB yl 0 0 f0 Ol o wo 0 M _ =1 I __ ■ Q • ;emu .� ��� 7 • \ • O , OR O 0 , \ •'f0 • • %f 0ll0 •. L �•� 67 •...•• QCLASSROOM f{tlJ9• • ^ sp, RESOURCE ►' go ' CLASSROE1 o 0 0 0 �:' •""�' o 0 0 0 0 0 CLASSROOM 0 0 0 0 �ii ,... ;� rr . s o o o o a o -�- o 0 0 0 o a o o o 0 �, �, / COVERED AREA ® _13 ®. - ® 13 . ®.. ® 13 , - ®- CRERED AREA- ® ®_ . _ ® . _ ® - ®" -13 ®' Ilia! _.._O::_=: ::-.:::: -::EFI- -. _._---�- --_ :-:-:--- 'L]'--::-.: -____ Lk7 ___ __. �__ :: -:-.- - ----.-------ni IKE --__fim 1 I � COURTYARD lH D - .. - .. - - -o nEN - - o Q o n - 93 - ® __ ® ® ®, - - - . ®,.- - ®- ®, _ ®. -_- ® CEVEREDAREA ® ® _ ®_ - - - ® ®13 ®-. _ 13 - ® ' A91 T)a rou - �-_^ JANITdR'` A-9 _ _ O � ELECTRIC � - - - - � � _ _ � O O O O 4 ' 0 O Q 0 Q Q A- C R O O O O O O O SSROOM 0 Q O O O CORRIDOR' O O O O CORRIDORM g CLASSRO SSROOM CLASSRO CLASSROOM CLASSRO _ Q 0_ -- CORRIDOR CO Q O O O O ETIA 9 A 9�� � O ED O O O O- O O O --- O O O O PIE r A-8 A 7 A A A-6 @ O ART O O OMPUTER Q o 0 0 -Q o o -- -Q 4 4 0- 4 A-16 -i A 8 ' 1 °q O f i I i I E�� CLASSROOM %�-8 CLASSROOM I 'CLASSROOM ' A_7 A-7 CLASSROOM 'CLASSROOM ' CLASSROOM ' / 1 I �• A l O L"J 0 I v I � 1-=' '-T' �-=L I v I O I vI _Fo_Fol v I O - FOR A_ 4� �X�XXY\`\T IIII : Fij 0 0 p' _: - W c0 - i= F- i�'•.% Z to " n \. I11 1100 fib By SttudbOdumv E-I w 1� wo Q�c '/� Fx u w UL C ~ 0 o a Q U U W 0 a 0 0 Q z 0 U " 1 ) LIGHTING PLAN E001 J SCALE: 3/32" = V-0" DRAWN BY: - DESIGN DATE: 11121/20' REVISION 1: c REVISION 2: SCALE: 3/32" = 1'-01, GENE11 RAL ELECTRICAL NOTES CONTRACTOR SHALL VERIFY ALL REQUIREMENTS FOR TELEPHONE AND POWER SERVICES WITH RESPECTIVE UTILITY COMPANIES PRIOR TO SUBMITTING THE BID. IF THEIR REQUIREMENTS ARE AT A VARIANCE WITH THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL INFORM THE ARCHITECT IMMEDIATELY. ALL COSTS INCURRED WITH THE UTILITY COMPANIES FOR SERVICES SHALL BE INCLUDED IN THE BID PRICE. IF SUCH COSTS ARE NOT AVAILABLE AT BID TIME, THE CONTRACTOR SHALL INCLUDE WITH BID, A LETTER FROM A RESPONSIBLE PARTY WITH THE UTILITY COMPANY STATING SUCH, AND COSTS WILL THEN BE EXCLUDED FROM THE BID PRICE. THIS CONTRACTOR SHALL VERIFY EXACT REQUIREMENTS FOR MECHANICAL EQUIPMENT FROM MANUFACTURERS RECOMMENDATIONS PRIOR TO ROUGHING IN CONDUIT SIZE, WIRE SIZE AND CIRCUIT PROTECTION SIZE ACCORDINGLY. IF REQUIREMENTS ARE LARGER THAN CALLED FOR ON THE ELECTRICAL PLANS, NOTIFY THE ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VISIT THE SITE OF THE WORK PRIOR TO SUBMITTING BID TO EXAMINE CAREFULLY LOCAL CONDITIONS AND DIFFICULTIES TO BE ENCOUNTERED. ANY DISCREPANCY BETWEEN PLANS AND EXISTING CONDITIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. COMPLIANCE STATEMENT ELECTRICAL SHALL COMPLY WITH ALL PROVISIONS OF THE 2014 NEC, NFPA 70 NEC 517 AND OTHER APPLICABLE CODES AND ORDINANCES. A]d F� 0.l8 k1 k k ELECTRICAL NOTES ALL ELECTRICAL WIRING EXPOSED TO VIEW IN EMT ALL ELECTRICAL IN CONDUITS, ARMORED CABLE OR BLUE CARLON CONDUIT ALL 110V EQUIPMENT RECEPTACLES MUST BE GFCI PROTECTED PER NEC 2014 210.8(B)(2). ALL CONDUITS RUN PARALLEL OR PERPENDICULAR TO STRUCTURAL FRAMING. ALL LO-VOLT WIRING BY OTHERS UNDER SEPARATE PERMIT. INCREASE WIRE SIZES FOR RUNS OVER 100' PER NEC 2014. CLARIFICATION NOTES ALL GENERAL PURPOSE RECEPTACLES WITHIN 6 FEET OF A SINK SHALL BE GFCI PROTECTED. ALL 125V SINGLE PHASE EQUIPMENT RECEPTACLES TO BE GFCI PROTECTED ON GFCI BREAKER CIRCUIT. ELECTRICAL NOTES 2017 FBC (Energy Conservation) - Section C405.2.1 Occupant Sensor controls. Occupant sensor controls shall be installed to control lights in the following space types: 1. Classrooms/lecture/training rooms. 2. Conference/meeting/multipurpose rooms. 3. Copy/print rooms. 4.Lounges. 5. Employee lunch and break rooms. 6. Private offices. 7. Restrooms. 8. Storage rooms. 9. Janitorial closets. 10. Locker rooms. 11. Other spaces 300 square feet (28 m2) or less that are enclosed by floor -to -ceiling height partitions. 12. Warehouses. 2017 FBC (Energy Conservation) - Section C405.2.1.2 Occupant sensor control function in warehouses. In warehouses, the lighting in aisleways and open areas shall be controlled with occupant sensors that automatically reduce lighting power by not less than 50 percent when the areas are unoccupied. The occupant sensors shall control lighting in each aisleway independently and shall not control lighting beyond the aisleway being controlled by the sensor. 2017 FBC (Energy Conservation) - Section C405.2.2 Time -Switch controls. Each area of the building that is not provided with occupant sensor controls complying with Section C405.2.1 be provided with time switch controls complying with Section C405.2.2.1. ANSI Standard 90.1-2016 Section 8.4.2 - Automatic Receptacle Control The following shall be automatically controlled: a. At least 50% of all 125 V, 15 and 20 amp receptacles in all private offices, conference rooms, rooms used primarily for printing and/or copying functions, break rooms, classrooms, and individual workstations. b. At least 25% of branch circuit feeders installed for modular furniture not shown on the construction documents. This control shall function on a. A scheduled basis using a time -of -day operated control device that turns receptacles off at specific programmed times —an independent program schedule shall be provided for controlled areas of no more than 5000 ft2 and not more than one floor (the occupant shall be able to manually override the control device for up to two hours); b. An occupant sensor that shall turn receptacles off within 20 minutes of all occupants leaving a space; or c. An automated signal from another control or alarm system that shall turn receptacles off within 20 minutes after determining that the area is unoccupied. All controlled receptacles shall be permanently marked to visually differentiate them from uncontrolled receptacles and are to be uniformly distributed throughout the space. Plug-in devices shall not be used to comply with Section 8.4.2. Exceptions to Section 8.4.2 Receptacles for the following shall not require an automatic control device: 1. Receptacles specifically designated for eouinment reouirino continuous operation (24/day. 365 days/vear). Provide ARC Flash warning labels on all switchboards, panelboards, industrial control panel, meter socket enclosures, motor control centers.To be locate by contractor per NEC article 110.16 2017 FBC (ENERGY CONSERVATION) - SECTION C405.6.4.1 RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER INCLUDING: 1. A SINGLE- LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM. 2. FLOOR PLAN INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. 2017 FBC (ENERGY CONSERVATION) - SECTION C405.6.4.2. OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER 2017 FBC (ENERGY CONSERVATION) - SECTION C408.3.1. FUNCTIONAL TEST OF THE LIGHTING CONTROL SYSTEM TO BE DONE PRIOR TO PASSING FINAL INSPECTIONS. 2017 FBC (ENERGY CONSERVATION) - SECTION C408.3.1.2. WHERE TIME -SWITCH CONTROLS ARE PROVIDED, THE PROCEDURES 1 THRU 8 SHALL BE PERMORMED. INSTALLED LIGHTING CONTROLS PERFORMANCE CRITERIA OF SECTION C405 TO BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY PER FBC 6TH EDITION(2017) ENERGY CONSERVATION- SECTION C408.3.2 WHERE REQUIRED, DAYLIGHT -RESPONSIVE CONTROLS SHALL BE PROVIDED WITHIN EACH SPACE FOR CONTROL OF LIGHTS IN THAT SPACES AND SHALL COMPLY WITH FBC 6TH EDITION (2017) ENERGY CONSERVATION CODE CHAPTER 4 SECTION C405.2.2.2, C405.2.3.2 AND C405.2.4 ---- - - --- - ---- - - - - - - - - - - - - - a oB Lo f^i - - - - - -- - - - ---- y �j 00. CLASSROOM CLASSROOM CLASSROOM of [o — I — :• IL .<O .I �♦.19 oB <o / OAF (0 0l l0 CLASSROOM CLASSROOM Vi 01 CLASSROOM • • • CLASSROOM/ RESOURCE /n]\ /n]\ /1\ /_\ /n1\ \ /_\ �,���y,�. --_,,,, - ©� ©. ©� I� n - d i - . ♦._.:._♦... ... ♦.♦:y � �♦:.:._._♦_.:i - -._♦_.:._♦....:._� � .� �.♦_♦:♦-�-. .� - ��-�.-.- moo.-.-..... ♦_._i_.-.-._.� -.:�_.-..moo. I �♦ ♦..♦:.:.: -�...-. I� .. .o.-♦_..: - _�.-..- ..�.-�: _o.._._..._ - E �! L •. , - ...- ..♦ �. ♦v N3 G2 M W - W :Z U O 01.,= a _ W W O = - F - o = _ :U Q o v z in OLU (D z 0 J_ m w Q _ H U J J v 01 m a0o M L. Z J =LL J Q W 2 � 0 o - F ro go60? W < cr R gX C? QU—� ��V rn M 4aa 0 IL IL EL = 0 0 � 0000 00 WZz � � W J Z oma� Z U OU as 00 WLu Ir o Z = 0 U� Q = i W Q W X (D Z o O W CO J = gz N Z ~ w (n a= 0- wHOw O z wcn(UZ I=-cn W(� O CZ 000 zz 3:Z =00 (¢jW LL CD Z Q W W Ui- n U U W W O 2 = 00 I— H 7� W do �11 l l � W �O O z U WO U 9 � p_ OLL W J W � m 0 F� F \ W O W a a ELECTRICAL POWER PLAN E002 SCALE: 3/32" = V-0" DRAWN BY: - DESIGN DATE: 11/21/2018 REVISION I: DATE SHEET: REVISION 2: DATE E00 SCALE: 3/32" = 1.4. ATTIC SPACE LIGHTINING PLAN E002 SCALE: 3/32" = 1'-0" .. • • 9.N i� o 9 U- O - w m 41 F- O; O ;�'•> z IQ— v• Q; O z 0 J_ 5 m w x H V J J v co �M Z:) J JLL W ~ O m � J o c? W Q 2 � < ? � CU�� a oaf C v O S ¢ � vaaLL K EL EL a x cn w � �o LL QUO Z � LL1 — z oow J z omao w<� o O ¢�Cw 0.O Ou u- UOX Q =ow (� p pz QW W(7 O L w z z O W U — J S Q N z ~ J W - /n a= W~O�w w� U) ��wZ o(- D z=W OOzz 3:z— O0UW /n F LL a)zF n w w�� U1- U U N W W O 2 2 ❑ 0 H 1- O J LL m F- DRAWN BY: W.J.S. O 1 ATTIC SPACE ELECTRICAL PLAN E002 SCALE: 3/32" = 1'-0" DESIGN DATE: 10/24/2018 REVISION 1: DATE F REVISION 2: DATE C('' SCALE: 3/32" = 1--0" G" ypc coo , LOAD CALCULATIONS PANEL LOAD CALCULATION CONNECTEDKVA DEMANDFACTOR DEMAN LOAD LIGHTING 20.572 1.25 25.715 KITCHEN EQUIPMENT 17.5 0.65 11.375 RECEPTACLES 72 1 72 WATER HEATER 6 1 6 TOTALDEMAND 115.09 VOLTAGE 120/208 DEMANDAMPS 319.836594 UTILIZE 400 AMPS SERVICE LOAD CALCULATIONS PANEL B LOAD CALCULATION CONNECTED KVA DEMAND FACTOR DEMAN LOAD HVAC 162 1 162 TOTAL DEMAND 162 VOLTAGE 480/277 DEMANDAMPS 195.0867052 UTILIZE 250 AMPS SERVICE LOAD CALCULATIONS PANEL C LOAD CALCULATION CONNECTED KVA DEMAND FACTOR DEMAN LOAD HVAC 1 126 1 126 TOTALDEMAND 126 VOLTAGE 480/2778 DEMANDAMPS 151.734104 UTILIZE 200AMPS SERVICE ELECTRICAL LEGEND 0'-,' RECEPTACLE AR DUPLEX 42" A.F.F. Q DISCONNECT SWITCH OH FIRE ALARM CEILING MOUNT HEAT DETECTOR SW^ SPLIT SWITCHED OUTLET ELECTRICAL PANEL O FIRE ALARM CEILING MOUNT SMOKE DETECTOR _-, 220v OUTLET MAIN DISTRIBUTION PANEL GFCI ,- GROUND FAULT OUTLET F o 1 20RECESSED LED TROFFER COMBO EMERGENCY LED LIGHT /EXIT SIGN -1 WEATHER PROOF GFI OUTLET ® LED EXIT SIGN ILLUMINATED $ SINGLE SWITCH ® 2x4 RECESSED TROFFER LED NIGHT LIGHT SWITCHED w/ 90 MIN. BATTERY BACK-UP EMERGENCY FIRE ALARM SPEAKER/STROBE CEILING MOUNT $a 3-WAY SWITCH SWITCH ® 4' STRIP LIGHT SWITCHED w/ n FIRE ALARM SPEAKER/STROBE WALL MOUNT'a' 4-WAY 90 MIN. BATTERY BACK-UP DIMMER SWITCH ❑o UNDER CANOPY LED LIGHT FIXTURE O CEILING MOUNT INTERCOM SPEAKER $OS OCCUPANCY SENSOR SWITCH wq WIRELESS ACCESS POINT EXHAUST FAN / LED LIGHT 0 UNDER CANOPY LED LIGHT FIXTURE 90 MIN. BATTERY BACK-UP TRANSFORMER w/ T9 Panel 'B' load a b c load ckt description t p w a b c a b c w p t description ckt 1 AHU-1 20 3 12 2000 2000 12 3 20 AHU-2 2 3 2000 2000 4 5 2000 0 2000 6 7 CU-1 20 3 12 4000 4000 12 3 20 CU-2 8 g 4000 4000 10 11 4000 4000 12 13 AHU-3 20 3 12 2000 2000 12 3 F20 AHU-4 14 1.5 2000 2000 16 17 2000 2000 18 19 CU-3 20 3 12 4000 4000 12 3 CU-4 20 21 4000 1 4000 22 23 4000 4000 24 25 AHU-5 20 3 12 2000 2000 12 3 20 AHU-6 26 27 2000 2000 28 29 4060 2000 2000 30 31 CU-5 20 3 12 4000 12 3 20 CU-6 32 33 4000 4000 34 35 4000 4000 36 37 AHU-7 20 3 12 2000 2000 1 12 3 20 AHU 8 38 39 2000 2000 40 41 2000 2000 42 43 CU-7 20 3 12 4000 1 4000 12 3 20 CU-8 44 45 4000 4000 46 47 4000 4000 48 49 AHU-9 20 3 12 2000 4000 12 3 20 CU-9 50 51 2000 4000 52 53 2000 4000 54 55 6 5 57 58 59 60 a= 54,000 b= 54,000 c= 54,000 feeders panel load conduit 3" feed BOTTOM voltage 480/177 phase wire 3#350 THHN AL main 250A watts 162,000 neutral #350 THHN AL mounting SURFACE amps 195 ground #2 AL Mfg AIC 65000 type 480/277/3ro Panel 'C' load a b c load ckt 1 description AHU-10 t 20 p 3 w 12 a 2000 b c a 4000 b c w 12 p 3 t 20 description CU-10 ckt 2 3 2000 TTT9 4000 4 5 2000 11 6 4000 6 7 AHU-11 20 3 12 2000 1 1 2000 12 3 20 AHU-12 8 2000 2000 10 11 2000 2000 12 13 CU-11 20 3 12 4000 4000 12 3 20 CU-12 14 15 4000 4000 16 17 2000 4000 4000 18 4000 12 3 20 CU-13 20 19 AHU-13 20 3 12 21 2000 4000 22 23 2000 4000 24 25 AHU-14 20 3 12 2000 4000 12 3 20 CU-14 26 27 2000 4000 28 29 2000 4000 30 31 AHU-15 20 3 12 2000 2000 12 3 20 AHU-16 32 33 2000 2000 34 35 2000 2000 36 37 CU-15 20 3 12 4000 4 4000 12 1 3 20 CU-16 38 39 4000 4000 40 41 4000 4000 42 43 SPARE 10SPARE 44 45 SPARE SPARE 46 47 SPARE SPARE 48 a= 42,000 b= 42,000 c= 42,000 feeders panel load conduit 3" feed BOTTOM voltage 480/277 phase wire #250 THHN AL main 200A watts 126,000 neutral #250 THHN AL mounting SURFACE amps 152 ground #4 AL Mfg AIC 65000 type 480/277/3o *CONTRACTOR TO CONFIRM THIS INFORMATION WITH ELECTRICAL COMPANY SECONDARY FAULT CURRENT: 23,800 A (BASED ON 300 kVA 120/208V / 3 = 3.5%) MAX. AVAILABLE FAULT CURRENT AT SERVICE EQUIPMENT: 18,034 A BASED ON: NO. OF CONDUCTORS ON PHASE: 1 TYPE: 250 kcmil VOLTAGE: 120/208V 3-PHASE LENGTH: 30 FEET 12/03/2018 VOLTAGE DROP THE PLANS REFLECT SYSTEM VOLTAGES DROP AS PER FBC ENERGY CONSERVATION 2017 SIXTH C405.6.3. FEEDER CONDUCTORS ARE SIZED FOR A MAXIMUM VOLTAGE DROP OF 2 PERCENT AT DESIGN LOAD. BRANCH CIRCUIT CONDUCTORS ARE SIZED FOR A MAXIMUM VOLTAGE DROP OF 3 PERCENT AT DESIGN LOAD. W LL 6 �Y z co :Z W �; < o �: O z �.� %/ of ......PF� S F \\` 00 B C D E i A 3SETS-3#500 THHN AL D) #350 THHN AL 175 - - # 50 THHN ALHHN AL #2 THHN AL #350 THHN L FPL TO LOCATE UTILITY TRANSFORMER MAIN B 4SETS-3#250 THHN N AL DISTRIBUTION PANEL PANEL PANEL E #250 THHN AL PAD MOUNTED PANEL A g C I I 4SETS-1#250THHN AL #250 THHN AL UTILITY TRANSFORMER 800A TY112 400A 250A 200A 1#350 THHN AL WI SERVICE METER 4801277V,3P #4 THHN AL 460120&120V13PI60HZ TRANSFORMER KVARATING:112.5 C l 2SETS-3#250 THHN AL F l 1#3/0 THHN AL A F 2SETS-1#250 THHN AL #1THHN AL (2) 51TO X 10' 0" GND RODS a6'0"O.0 U J J v Of m m C co') z i J 7 LL J ui u IM 1­- O0 W a¢ rn � QUp� LL vOaxa 0 z 0 J � 0 m a W LL x x cn m �mo� Q ar O LL H (Z.� U O c� U I Y W Z z O 0 O W J z Uj W om a0 a 0 W g� 0 < 0_ LU U W 2O UQ� z ()LL 0 U.) ¢� ojr w z UOOz O <W 0LZ os w QCO0UJ CO� J W x Z Z N z W — m W H O f m U O Z W = H ~ co Z W - 00 zmw oozz zFO W Ox OU U W W (n� } ¢ W W Z) 10 2?V� W (n U U W = W o = x 0 o I— I- ^W^ I--i i—i W a O Q C I. W^ F--I U o co U Q u U W O C a O D' 0 F_ z 0 DRAWN BY: W.J.S. DESIGN DATE: 10/24/2018 REVISION 1: DATE I Px REVISION 2: DATE C SCALE: 3/32"=1'-0" CO( fW COMMUNICATIONS VOICE CLOSET CABLE Hp RUN PKSU E DATA CABLE RUN CABLE CABLE VOICE NOTES: 1 - ALL COMPONENTS PROVIDED BY ELECTRICAL CONTRACTOR 2 - ALL JACKS TO BE LABELED VOICE AND/OR DATA 3 - ALL JACKS TO BE NUMBERED TO CORRESPOND WITH PATCH PANEL 4 - PLENUM RATED CABLE TO BE USED AS REWIRED BY CODE 5 - INSTALL 3/4" CONDUIT FROM THE BOX TO AREA ABOVE THE CEILING. IN LINE OR LOW VOLTAGE SWITCH VOICE / DATA DOUBLE MODULAR JACK AT EACH PHONE POSITION DATA LOAD VOLTAGE OCUPANCY SENSOR 01-161-40 120V ELECTRICAL CONTRACTOR SHALL PROVIDE 120 VOLT CIRCUIT FOR SMOKE DETECTORS VERIFY FOR EXACT LOCATION. (TYP.) DISCONNECT SEE PANEL SCHEDULE WIRE SIZE AND CONDUIT 1. VERIFY NAMEPLATE RATINGS, LOCATIONS, AND POINT OF POWER CONNECTIONS PRIOR TO ROUGH -IN. 2. DO NOT LOCATE DISCONNECT SWITCHES OVER UNIT ACCESS PANELS. 3. PROVIDE A 3/4" EMPTY CONDUIT THROUGH INACCESSIBLE LOCATIONS(I.E. WALLS, UNDER SLAB) FOR CONTROL WIRING. COORDINATE WITH MECHANICAL PLANS. 4. EQUIP. REQUIREMENTS ARE FOR MANUFACTURE AND MODLE NUMBER LISTED ON MECHANICAL PLANS. THE MECH. CONTRACTOR SHALL BARE ANY ADDITIONAL COST. MECH. EQUIPMENT POWER RISER DETAIL LIGHTING CONTROL DIAGRAM 1/2" CONDUIT WITH #12 CONDUCTOR TO OVERRIDE TIMER (1/2 - 4 HOURS) AT ENTRY POINT. ADD FD34H TIMER. TYPICAL PANEL 2OA,2P TYP. 20A,1 P TYP. N LIGHTING CONTROLLER EXTERIOR AND INTERRIOR N.O. 20A, 120/277V. CONTACTS, 120/277V COIL NEMA 1 ENCLOSURE GROUNDING ELECTRODE CONDUCTOR DETAIL SERVICE EQUIPMENT 1/2" CONDUIT WITH PULL STRING NEUTRA TO ALARM CONTROL PANEL WHEN AVAILABLE BUS BUILDING STEEL FULL SI; (2) ASTRONOMICAL TIME SWITCH TC-1 FULL SIZE ELECTRC (ER NE RESERVE POWER FEATURE NEMA 3R ENCLOSURE AND CLOCK MOTOR OF SEE RISER DETAILS VOLTAGE COMPATIBLE WITH CONTROL CIRCUIT. NDI CONTACTOR C-1 LOCATED 3/4" x COPPER IN NEMA 3R ENCLOSURE. OUND RODS. CLAD GRO c SQ-D #SMG SERIES WITH CONTROL RELAY TO SITE LIGHTS SPARE SPARE SPARE TO BUILDING LIGHTS SEE RISER NOTE: CONTROL DEVICE TO BE INSTALL THAT AUTOMATICALLY TURNS LIGHTING OFF WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE, EXCEPT SPACES WITH MULTISCENE CONTROL IN CLASS ROOMS, CONFERENCE ROOMS, AND EMPLOYEE LUNCH/BREAK ROOMS. OCCUPANCY SENSOR AND EMERGENCY BALLAST DETAILS H (BLACKI H (BLACK) IN H POWER 1ST 2ND PACK OCCUPANCY OCCUPANCY ODP7-070 SENSOR SENSOR (AS REQUIRED) OCCUPANCY SENSORS: LEVITON OSC10-MO I j POWER PACK: LEVITON ODP7-070 f ADD -A -RELAY: LEVITON ODAOO-000 TO LUMINAIRES N CEILING OCCUPANCY SENSOR DETAIL BUS I GROUNDING CONDUCTOR TABLE 250-66) WATER PIPE ELECTRODE RING SEE NOTE #5. NOTES: 1. FULL SIZE GROUND MEANS THAT GROUND CONDUCTOR SIZE SHALL BE AS SHOWN ON SERVICE EQUIPMENT ON THE POWER RISER DIAGRAM. 2. AFTER GROUNDING SYSTEM IS INSTALLED, GROUND RESISTANCE SHALL BE MEASURED, TO ASSURE THAT GROUND VALUE OF 5 OHM MAXIMUM RESISTANCE IS ACHIEVED. IF NOT, ADDITIONAL GROUNDING SHALL BE PROVIDED TO MEET THE SPECIFIED VALUE. 3. ALL CONNECTIONS TO GROUND RODS SHALL BE EXOTHERMIC WELD CONNECTIONS. 4. GROUND CONDUCTOR SHALL BE LOCATED WITHIN OR NEAR BOTTOM OF CONCRETE FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT WITH THE EARTH, AND SHALL CONSIST OF AT LEAST 20 FEET OF ONE OR MORE STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2 INCH DIAMETER, OR OF AT LEAST 20 FEET OF BARE COPPER CONDUCTOR. 5. A GROUND RING ENCIRCLING THE BUILDING OR STRUCTURE, IN DIRECT CONTACT WITH EARTH, CONSISTING OF AT LEAST (20 FT.) OF BARE COPPER CONDUCTOR NOT SMALLER THAN 2 AWG SHALL BE INSTALLED, PER ARTICLE-250.52(A)(4),NEC . WALL SWITCH TEST SWITCH TEST SWITCH H AC H AC BALLAST BALLAST EMERGENCY EMERGENCY BALLAST BALLAST ill ELECTRICAL DETAIL SHEET RED INDICATOR LIGHT RED INDICATOR LIGHT N UNSWITCHED FIXTURE SWITCHED FIXTURE EMERGENCY BALLAST DETAILS WALL SWITCH / SENSOR LEVITON ODSOD-IDA N (WHITE) LUMINAIRES NEEDED) TO LUMINAIRES WALL SENSOR DETAIL V J Z r o 00 W *-m co Z D .a • o Z u- W E a 03 O cc O � to L a° c�nisF..sa2';. z * ! No. 60102 '� s = tr = STATE OF 01-OS-ZO 19 w LIFE SAFETY CODE COMPLIANCE LIFE SAFETY CODE: 2017 6TH EDITION MEANS OF EGRESS SHALL COMPLY WITH CHAPTER 7 AND CHAPTER 39 LIFE SAFETY -MEANS OF EGRESS CHAPTER 39.2 GROUP E (EDUCATIONAL) SPRINKLERED CONSTRUCTION TYPE: V-B OCCUPANT LOAD FACTOR TABLE 7.3.1.2 OCCUPANTLOAD: OCCUPANCY GROUP: E = EDUCATIONAL THE OCCUPANT LOAD = 20 GROSS PER TABLE 1004.1.2 SECTION 906 FBC PORTABLE FIRE EXTINGUISHER CALC: MAX 1,500 S.F. PER UNIT (28,868 S.F. 1,500 = 19.24 ) # OF FIRE EXTINGUISHERS REQUIRED: 20 # OF FIRE EXTINGUISHERS PROVIDED: 22 CLASSROOM (FIXED) =486PERSONS MAX DISTANCE BETWEEN: 50' OFFICE/WAITING = 6 PERSONS RESTROOM = 6 PERSONS TOTAL = 497 PERSONS COMMON PATH LIMIT -ACTUAL: 661 (COMPLIES) MAXIMUM 100 ft. r �_ DEAD END LIMIT - ACTUAL: 0'-0" (COMPLIES) MAXIMUM 50 ft. TRAVEL DISTANCE -ACTUAL: 187'1 (COMPLIES) MAXIMUM 300 ft. INTERIORFINISH CLASSIFICATION LIMITATIONS PERTABLEA.10.2.2 EXITS ACCESS TO EXITS OTHER SPACES FLOORS (EXIT) A A& B Al CLASS I OR II COVERED DRIVE THRU 1 I I I I I I I I COVERED AREA LIFE SAFETY LEGEND DIRECTION OF TRAVEL FIRE ALARM CEILING MOUNT HEAT DETECTOR 0 FIRE ALARM CEILING MOUNT SMOKE DETECTOR SECURITY LIGH I FIXTURE WALL MOUNTED COMBO EMERGENCY LIGHT / EXIT SIGN ® EMERGENCY EXIT SIGN ILLUMINATED FIRE ALARM SPEAKER/STROBE WALL MOUNT ® FIRE ALARM SPEAKER/STROBE CEILING MOUNT CLASS 2A10 FIRE EXTINGUISER * SEPARATE PERMIT REQUIRED FOR FIRE SPRINKLER SYSTEM MODIFICATIONS. - PERMIT BY OTHERS * SEPARATE PERMIT REQUIRED FOR FIRE ALARM SYSTEM MODIFICATIONS. - PERMIT BY OTHERS * THERE WILL BE A SPRINKLER SYSTEM - SEPARATE PERMIT REQUIRED COVERED AREA LIFE SAFETY NOTES * MINIMUM 36" DOOR LEAF AS REQUIRED FOR EXIT * EXITS SHALL BE MARKED BY AN APPROVED SIGN AND READILY VISIBLE FROM ANY DIRECTION OF EXIT ACESS * EMERGENCY LIGHTING SHALL BE PROVIDED * ONE PORTABLE FIRE EXTINGUISHER TO BE PROVIDED FOR EVERY 1,500SF OF FLOOR AREA OR PORTION THEREOF COMPLIANCE STATEMENT LIFE SAFETY PLAN SHALL COMPLY WITH ALL PROVISIONS OF THE LIFE SAFETY CODE 2017, 6TH EDITION AND OTHER APPLICABLE CODES AND ORDINANCES. H.C. COMPLIANCE NOTES CHANGES IN LEVEL AT DOOR THRESHOLDS BETWEEN 1/4" AND 1/2" EDGE SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 WITH MAXIMUM 1/2" THRESHOLD. DOOR CLEARANCES FOR FRONT APPROACH & PULL SIDE, PROVIDE 18t' BEYOND LATCH SIDE OF DOOR, 60" PERPENDICULAR TO DOOR WAY. DOOR HANDLES, PULLS, LATHES, LOCKS AND OTHER OPERATING DEVICES SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. CONTRACTOR TO PROVIDE ALL HANDICAPPED TOILET FIXTURES AND ACCESSORIES PER CODE, CONTRACTOR TO MAINTAIN 60" DIAMETER CLEARANCE MINIMUM TO ALL FINISH SURFACES WHERE INDICATED ON THE DRAWINGS. AREA TABULATION AIR CONDITIONED AREA SF 19939.9' RISER ROOM SF 47.40 ELECT. ROOM SF 352.7 OUTSIDE COVERED AREA SF 8528 TOTAL AREA UNDER ROOF SF 28,868 OFFICE � W l u OFFICE 12B 259E OFFICE ST 251liE SF GHT.10'A H<. `" OFFICE Iiiii \ BRGHill taE'. CLG12926HEIGHT'9'-0• 129.259E I G. .125 9'%•'1J� y. EIGHT:9'-0• CLG. H I CLG. HEIGHT: 9'% 31 TVA 130 129ADMIN.0 S II I F, \ N 5B'� f �� N R �5 4 UF( o�s��CLG NBRG. 1 eacE ,as•is, HEGHT a%�] ei� t Asv 128�vr�';1CLASSROOM'`ba ® N .- �,. NFC.I .,CLG. COORIDORCLASSROOM CLASSROOM HEIGHT: 9%CLASSROOMADMIN 10a ,li CLASSROOM CLASSROOM s .43SFCLASSROOM HHMSF_ _ _ __ __-® HEIGHT. 10'W TBCMLG - _ 4M50T BRG rvEI��tB•-0• G. HEIGHT:9% 4W.093F BRG. HEIGHT: ttl --� CLG. HEIGHG1ROO CLASSROOM BRG HEGHr'1aA• 454.43 SF BRG. HEIGHT: III LLG HEIGHC 9-0• .SF BRG HEIRTatl-0• cLG. HEGHT: N-0• BRG HEGHT. I CLG. HEIG11T:9-0• 112 BRG. HEIGHT: i�E' CLG.'E14 g% GIRLS /Il 2]973`FRESTR BOYS- HEGHT:9ff J 101SO .i.. CL'�06:9-0' 108 9RG HEIGHTVIO'd' ttiHEGHi9'9" 17965SO133 Ro i I,tESTR00 210 2 12 �125CLG .,vr .160R:2F!�FFIC $'n.Hara , 13a , `-"`vSTAFF RE1SHEIGT: Fdab®.vpP' m'.w ;<4` LOUNGE1 Mile$IF ®I, s s tom"% •1'.® ���` • )• M a. MUSsC RO. ENCE ttl% cLa. y' `�. q.CONiN �. ��t B HEIGHT..'9-0BRGHEIGHT: 'e"'-o �E42:9a• % ; L ® ��� '�i RRID R q ., 2e,�. 1 1 1 I a ® ISHOWGIG 1ze 136 ®�� 7 i I11pZ13 I o`ORAGE FFzCE TAFF REST4TAF Oti RE5T T Si'AF RESTIC mESTH RES�s I .11 M'a «p n' - _ -- _ CAFETORIUM SL3316SF BRG. HEIGHT: t9% CLG. HEIGHT: 9'% 144 STORAGE L Til SF BRG. HEIGHT: R,H, LLG. HEIGHT: N-0• 146 vA m �o AZF PREP RESOURCE 2 955SF CAG. MIIGHT' WHIT 148 itOS25SF ' BRG HEIGHT:,ad' CLG. HEIGHT: 91 147 VELOASTANCERPl -_- ! S .HRIrtDOR �D1b ® BR�C icr<r 1$a% qyc� \ ® CORRIDOR '.si' ® 4s�?� CORRRIDOR �,^1E>' - _ Q dGG o _ 1 Roo- E M. `ejo \ q\ CLG. HEIGHF: V' �J. lY: B HEIGIIGTF: 10'B' O ® -0• , 117 `; 4G „EG -0• Ell HEIGIR:1aS RESOURCE / LI y H:g% \k; OI CLASSROOM', CLASSRO CLASSROOM 161 CLASSROOM, CLASSROOM CLASSROOM'. 45B95 sF N 11s BRG. HEIGHT ta% ! S SR N SS SF CLASSROOM >A N 4K.95 SF 455.859E N 11 460953E \ BRG. HEIGHT: t9d' CLG.HEGHT:9% BRG. HEIGHT: t9% BRG. HEGHTF BRG. HEGHT:1tl% 401.59 SF BRG. HEIGHTatl% BRG. HEIGHT: iS'41• CLG.HEIGHT:ff-0' 115 \ N j CLG. HEIGHi:9'-0• CLG HEIGHT. ff% CLG HEGH):9-0' O CLG.HE�GMT:ff% ty� CLG.. HEI�GHT:ff% BRG HEIIGHTi \ I 111 113 102 ��� 103 v 1os �� �v ( j LLG. MEGXT:9-0' 1 07 109 �i I _y_ - - - - - _ - - - �- - - - - 25 OCCUPANTS EACH COVERED AREA ]T DOOR IWOTH PROVIDED SSREQUIRED S PROVIDED - -31W R RUW COVE---- --------- �1 EACH -- -- ANTS EACH ---- _. _____-----1�-I _- RED 5"REOUIRED PRONGED Ll _ __ _ ____ L• •�I - (• ]Y' GOOR WIDTH rousigrzyiTTla M 177' DOOR WIDTH PROVIDED FV •ol _ -_ •- ____-__ _._.. __- •-�I •-�i •q____—.... __-:a-il _ _.__. •v� ---_ _ __. ••. ___- �`•. �,---_. ___ L-iL_---._-. 250CCUPAN•• •.• _ -- -- ---- ' --' .•I - ____ ___ ... TS EACH 100 OOCUPANT3 IN OCCUPANTS 100 CCCUPAMS 5' RE4UIRED 2O REOUIREO ® _ - - __ _ - _. _ TRAVELOISTANCEi]4'-00' - _2tl'REOUIREO - - -_ - - __ -_ - _.. -- - - 2'REOUIRED _ - _ _- _. _- _.. - -- - - _ _ -- _- - W-DOORMUTHPRCVIDET) -------------------------- - - - - -- - - COVERED AREA - n -- ]T DOOR WIDTH PROVIDED ]T DOOR WIDTH PROVIDED ]T DOOR WIDTH PROVIDED a - _. l I 1 I II 13 'Hill, i i i j doi - '�'v rRai.- 'v Ili 1 I lit+ JANITOR �4 -I- EI H�'v°-ol ] cF�orb. •'.�� N � ^� 4 N DATA/ ELECTRICAL Q� s\ B4 BF 01 ctG HE�cHT' .v ® .� I , �� ® �® ��,! m3�sF CO BRG,HR¢R CLASSROOM 69BF (y,) '�` CLASSROO CLERG HEIGHT, 19-8 ASSROOM C� -- - BRG.C. HEIGHT _i0A CL., AUGH 4-a BgT.HEIGHY.,O'e• BRG. HEIGHT.,O'-0 �• C01 RR�DTR O BRG HEIGH41 T IO-BM CLG. HEIGHT:9Y '� 1 BRG. HEIGHT.IO�M m N CLASSROOM b12 T /, cLF ,E6, 9'-0' CLASSROOM CLG GROOM HT W-0 Ba° HE Hr:'�-0' , GLG � se W­()` -a 170 \\ S�2RId�(UR i �. _ CLASSROOM � 1731 III ® ® Sip S a S S RL q 5'lW; v I LL T 4Ei- NJ pC OC' In lymww ,. rc� p0 ART m ! BRG LOPEc rF,O'a' COMPUTER LABS ,��, / r� Der �53sf,.�a. o�,to1 Ell 3 ® %% C. HEIGHT: ill _ ! 155 BRG HEIG�NLFitl-0' O�SSF]N.. Myly( CLASSROOM �TF 1"/ CLASSROOM �`��s CLG. HEIGHT 'FV 2 ��yZ/'1JSROOM BRG H�EIGFrtFtbA '3T r C t 5� CLASSROOM CLASSROON�"' �• CLASSROOM 59A49F e 400045E 480040E MOO SF BRG. HEIGM'10'-6' I o 11 II ® C G HEIGHP 9% CLGHEI HT'9{Y' BRG HEIGHT',0'E' CLG. HEIGHT'S-b' BRG HEIGHT IO'-0' CLG. HEIGHT '9'U' Vil I CLD_ 1E6HT 9-0 1 67 - cLG HEIGHT SD' 172 ROOCCUPANT9 .. RE.EIRE0 IU DOOR WIDTH PROVIDED LIFE SAFTEY PLAN A001 SCALE: 3/32" = V-0" :� o O p�• Lu iL :Z a W - _ w (0 Q z = U c Y' m l o O v> '•.> z a N o � • : `Gj c c� o 'I ,......�\\,. P F 11L/IIIilwk11,\\\ U J J J c w o'er •� aD rn a�Op m Q U ��01 1L v Oa a 0 z 0 J F �0 m O a w a x z x x O ~ 10 uj � ~ 2 Z O LL w F U` L O U W J Z o Lii w0ma0 _ Oz-O06 U C) x W Q U W I- w 2O U LL z O w p W z U O LL N KLE Z z cn O3 a F WZ� zQQJcoww 02 Q�pW OJ zE)=Z�a N-n� OWU I J W H O Q x ca W O z w w = x<n'Z0 5 a w cf) Z O w w O 0 0 z ww I LL o Z 1= V= W z O W D LL Q am 0 tnZ F(C11)) 0 m mz2Wjj� go IL W cnUNw w0 x W 0 x x x J _ooLL w 83 7 l M W O O pill U WO L zQvo O 1� Uwe cn I-, [ ., m o 0 C) U O IL O F- F. Z O DRAWN BY: - DESIGN DATE: _ 10/24/2018 REVISION I: DATE_ SHEET: REVISION 2: DATE A001 I SCALE: 3/32 - 1 -0 'SEE SHEET E003 FOR AIR HANDLER UNITS LOCATION ON ATTIC SPACE LOCATED AT ALL AM UNDS xd EX7 ALUMINUM HOOD wdBIND SCNI MECHANICAL 1. ALL HVAC WORK TO BE DONE IN ACCORDANCE WITH THE 2017 FBC (MECHANICAL) CODE, INCLUDING ALL STATE AND LOCAL CODES AND THE 2017 FLORIDA ENERGY CONSERVATION CODE FORA COMMERCIAL BUILDING. 2. ALL PERMIT APPLICATIONS SHALL BE APPLIED FOR, ALL FEES SHALL BE PAID FOR BY THE GENERAL CONTRACTOR FOR APPLICABLE WORK, ALL INSPECTIONS SHALL BE SCHEDULED AND COMPLETED. VERIFY PERMIT FEES WITH THE GENERAL CONTRACTOR. 3. THIS CONTRACTOR SHALL WARRANTY THE OWNER, IN WRITING, FOR ALL THE MATERIAL AND LABOR FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE OWNER ACCEPTANCE. COMPRESSORS SHALL BE WARRANTED FOR FIVE (5) YEARS. 4. ALL DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW STRUCTURAL MEMBERS, CHANGES IN CEILING HEIGHT, LIGHTS, OR ANY NUMBER OF OTHER NECESSARY ITEMS WHICH MAY INTERFERE WITH THE EXACT INSTALLATION AS REPRESENTED ON THE DRAWINGS. THIS CONTRACTOR IS EXPECTED TO COMPLETE THE INSTALLATION AS REQUIRED WITH WHAT EVER MODIFICATIONS THAT ARE NECESSARY TO AVOID THE CONFLICTING ITEM. CONTRACTOR SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AND SHALL COORDINATE WORK WITH ALL OTHER TRADES, PRIOR TO FABRICATING DUCT WORK OR INSTALLING EQUIPMENT OR PIPING. 5. PROVIDE THE OWNER WITH REPRODUCIBLE "AS-BUILTS" DRAWINGS AT THE COMPLETION OF THE PROJECT. ALSO PROVIDE THE OWNER WITH CATALOG CUTS OF ALL ITEMS OF EQUIPMENT WHICH HAVE MOVING PARTS, AND ENCLOSE IN A 3-RING BINDER AS THE OWNER'S MANUAL. PROVIDE A TEST AND BALANCE REPORT OF AIR QUANTITIES, FREON PRESSURES, AMPERAGE DRAWS, AND AIR TEMPERATURES BEFORE FINAL PAY REQUEST. PROVE HEATING AS WELL AS COOLING. 6. DUCTWORK SHALL BE 1" THICK FIBERGLASS DUCT, WITH AN "R" FACTOR = 6. ALL JOINTS ARE TO BE SHIP -LAPPED AND SECURED WITH OUTWARD CLINCHING STAPLES 4" O.C. ON ALL JOINTS AND SEAMS. SEAL FOIL BARRIER WITH MANUFACTURER APPROVED 2" WIDE FIBERGLASS GAUZE AND TWO COATS OF MASTIC. SUPPORT WITH TRAPEZE HANGER OR RIGID SUPPORT EVERY 4 FT.. FABRICATE PER SMACNA LOW VELOCITY DUCTWORK MANUAL. 7. FLEX DUCT TO BE BATT INSULATION OF R-6 VALUE, WITH EXTERNAL VAPOR BARRIER AND INTERNAL SPRING STEEL HELIX AND INTERNAL POLYETHYLENE LINER. SECURE AT MAIN TRUNK DUCT WITH A SPIN -IN -FITTING BY THE LATEST METHODS AS APPROVED BY THE MECHANICAL INSPECTORS. SUPPORT FLEX DUCTS EVERY 4 FT. WITH HANGERS OR SECURE TO BAR JOIST. THREAD FLEX DUCTWORK THRU OPEN BAR JOISTS WHEN POSSIBLE. 8. ACCEPTABLE DIFFUSER AND REGISTER MANUFACTURERS ARE METAL -AIR, ENVIRO-AIRE, AIR GUIDE, TUTTLE & BAILEY AND CARNES, PROVIDE A CLEAN SET OF FILTERS WHEN THE PROJECT IS TURNED OVER TO THE OWNER. FILTER RACKS AT THE A.H.U.'S ARE TO BE TAPED UP WITHOUT ANY FILTER. FILTRATION POINT IS AT THE RETURN AIR GRILLE IN ALL CASES. PROVIDE A LIST OF FILTER SIZES FOR THE OWNER ALONG WITH A CLEAN SET OF WASHABLE FILTERS AT TIME OF TURN -OVER. 9. ALL SUPPLY COLLARS AT ROUND DUCT BRANCHES TO BE WITH BELL MOUTH FITTING, VOLUME DAMPER, AIR SCOOP AND INSIDE AND OUTSIDE CLAMPING RINGS. 10. ALL DUCT DIMENSIONS INDICATED IN THE DRAWINGS ARE CLEAR AIRSIDE DIMENSIONS. 11. PROVIDE READY ACCESSIBILITY TO DAMPERS AND OTHER PARTS OF THE SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE OR OPERATIONS. 12. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTOR BEFORE ORDERING ANY EQUIPMENT. 13. OUTSIDE AIR QUANTITIES TO BE MATCHED TO THE O.A. LISTING ON THE PLANS. SMOKE DETECTOR REQUIRED IN AIRDUCT SUPPLY SYSTEM PER SECTION 606.2.1 MECHANICAL NOTES RIGID DUCT -ALL RIGID DUCT TO BE 1" FIBERGLASS FIBRE -REINFORCED FOIL WRAPPED DUCT. -ALL 90" TURNS SHALL HAVE INTEGRAL TURNING VANES. -ALL JOINTS SHALL BE MADE USING "FASON" SYSTEM TAPE AND MASTIC. CI CY r11 Ir'T -ALL FLEX DUCT SHALL BE OF SIZE NOTED WITH R-6 INSULATION AND SLEEVE WRAP. -ALL FLEX SUPPLY DUCTS SHALL BE CONNECTED TO THE MAIN TRUNK LINE WITH A MANUAL DAMPER. *FINAL INSTALLATION SHALL BE FIELD TESTED AND BALANCED FOR CFM's SHOWN. COMPLIANCE STATEMENT MECHANICAL SHALL COMPLY WITH ALL PROVISIONS OF THE FBC, MECHANICAL, 6TH EDITION AND OTHER APPLICABLE CODES AND ORDINANCES. INTERIOR DOORS TO HAVE 1-1/2" CLEARANCE UNDERNEATH TO ALLOW FOR PROPER AIR TRANSFER * RATES ARE PER WATER CLOSET OR URINAL. THE HIGHER RATE SHALL BE PROVIDED WHERE THE EXHAUST SYSTEM IS DESIGNED TO OPERATE INTERMITTENTLY. THE LOWER RATE SHALL BE PERMITTED ONLY WHERE THE EXHAUST SYSTEM IS DESIGNED TO OPERATE CONTINUOUSLY WHILE OCCUPIED * RATES ARE PER WATER CLOSET OR URINAL. THE HIGHER RATE SHALL BE PROVIDED WHERE THE EXHAUST SYSTEM IS DESIGNED TO OPERATE INTERMITTENTLY. THE LOWER RATE SHALL BE PERMITTED ONLY WHERE THE EXHAUST SYSTEM IS DESIGNED TO OPERATE CONTINUOUSLY WHILE OCCUPIED FBC 607.5.4. CORRIDORS/SMOKE BARRIERS A LISTED SMOKE DAMPER DESIGNED TO RESIST THE PASSAGE OF SMOKE SHALL BE PROVIDED AT EACH POINT A DUCT OR AIR TRANSFER OPENING PENETRATES A SMOKE BARRIER WALL OR A CORRIDOR ENCLOSURE REQUIRED TO HAVE SMOKE AND DRAFT CONTROL DOORS IN ACCORDANCE WITH FBC, BUILDING. A CORRIDOR DAMPER SHALL BE PROVIDED WHERE THE CORRIDOR CEILINGS, CONSTRUCTED AS REOUIRED FOR THE CORRIDOR WALLS AS PERMITTED IN SECTION 708.4, EXEMPTION 3, OF FBC, BUILDINGS, ARE PENETRATED. A CEILING RADIATION DAMPER SHALL BE PROVIDED WHERE THE CEILING MEMBRANE OF A FIRE -RESISTANCE -RATED FLOOR/CEILING OR ROOF/CEILING ASSEMBLY, CONSTRUCTED AS PERMITTED IN SECTION 708.4, EXEMPTION 2, OF FBC, BUILDING, IS PENETRATE. SMOKE DAMPERS AND SMOKE DAMPER ACTUATION METHODS SHALL COMPLY WITH SECTION 607.5.4.1 S E P A R A T E P E R M I T S R E Q U I R E D ALL FIRE PROTECTION SYSTEMS, FUEL, GAS, SIGNAGE AND OTHER BUILDING COMPONENTS REQUIRED BY LOCAL BUILDING AND FIRE AUTHORITIES TO BE INSTALLED OR MODIFIED VIA SEPARATE PERMIT, AND WHICH ARE AFFECTED BY THE WORK PROPOSED HEREIN, SHALL BE DULY INSTALLED OR MODIFIED ONLY THROUGH SEPARATE PERMIT AUTHORIZATION FROM THE AUTHORITY(S) HAVING JURISDICTION. AIR BALANCE SCHEDULE UNIT HVAC SUPPLY HVAC RETURN HVAC OUTDOOR MAKE - UP EXHAUST GENERAL AREA SERVED DESIGN DESIGN DESIGN DESIGN DESIGN DESIGN AHU-1 2000 1340 660 AHU-2 2000 1355 645 AHU-3 2000 1355 645 AHU-4 2000 1355 645 AHU-5 2000 1355 645 AHU-6 2000 1355 645 AHU-7 2000 1355 645 AHU-8 2000 1355 645 AHU-9 2000 1355 645 AHU-10 2000 1355 645 AHU-11 2000 1355 645 AHU-12 2000 1355 775 AHU-13 2000 1355 775 AHU-14 2000 1355 775 AHU-15 2000 1355 775 AHU-16 2000 1355 775 EF-1 225 RESTROOM EF-2 225 RESTROOM EF-3 70 RESTROOM EF-4 70 RESTROOM EF-5 70 RESTROOM EF-6 70 RESTROOM EF-7 225 RESTROOM EF-8 225 RESTROOM EF-9 70 RESTROOM EF-10 70 RESTROOM EF-11 70 RESTROOM EF-12 70 RESTROOM EF-13 70 RESTROOM EF-14 70 RESTROOM TOTAL 32000 1 21665 10985 0 1600 0 TOTAL 250 BUILDING PRESSURE NOTE: VERIFY MANUFACTURE SPECIFICATIONS OF SPECIFIC UNITS FOR ELECTRICAL REQUIREMENTS. CONDENSER UNIT(CU)-1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 CONDENSOR UNIT Schedule PLAN MARK CU MANUF. UNIT 4TWA406OA4 NOMINAL TONS 5 MAXIMUM CFM 2000 COOLING CAPACITY 60,000 MCA 9 MOPC 15 TRANE AHU SCHEDULE PLAN MANUF. UNIT MARK AHU TRANE TWE061D400A Exhaust fan schedule EF # Area served Manufacture I CFM Volt_ Bathrooms Broan or equal 225 120 �1,2,7,8 4,5,6,9,1d Bathrooms i Broanorequal I 70 1120 11,12,13,14 Air Device Schedule SEER I EER 14.0 I - NOMINAL MAXIMUM [COOLING MCA MOPC SEER EER TONS CFM CAPACITY 5 2000 60,000 17 20 14.0 - Plan 1 Mark Description Size Neck Material Manuf. / Model CD-1 Suppy Air Diffuser 24" X 24" See Plan i Aluminum price ASPD CD-2 Suppy Air Diffuser 12" X 12" See Plan Aluminum Price ASPD RG I Return Air Grille 24" X 24" See Plan Aluminum Price ASPD PER TABLE 403.3 FLORIDA BUILDING CODE 6TH EDITION 2017 MECHANICAL, OA ventilation OCCUPANCY CLASSIFICATION SF OCCUPANT DENSITY Rp Ra REQ. OA PROVIDED. OA CLASSROOM 12233 25 10 0.12 4526 CFM AHU 1,2,3,4,5,6,7,6,9,10 CORRIDOR 2163 - 0.06 130 CFM AHU 1,2,3,4,5,6,7,8,9,10,11,12 MUSIC 948 20 10 0.18 360CFM AHU 1 OFFICE 763 5 5 0.06 65 CFM AHU 13 CAFETORIUM 5,233 150 7.5 0.18 6829CFM AHU12,13,14,15,16 KITCHEN 1,105 20 7.5 0.12 299 CFM AHU 14 STORAGE 252 2 5 0.12 33CFM LOUNGE 265 25 5 0.06 49 CFM COMPUTER LAB 832 25 10 0.12 308 CFM CONFERENCE 190 50 5 0.06 59 CFM OTHER 1306 - - BATHROOM 1395 - - WAITING 187 50 7.5 0•06 81 CFM ART 832 20 10 0.18 316 CFM TOTAL OA REQ. 13055 CFM NOTE: CONTRACTOR TO LOCATE ALL PROGRAMMABLE THERMOSTATS VENTILATION PLAN LEGEND FNI SUPPLYAIR-CD1 In RETURN AIR-RG. 0 SUPPLYAIR-CD2. EXHAUST FAN BRAUN 9"X9",3 INCH ® PIPE,70 CFM UNIT OCCUPANCY SWITCH WITH LIGHT OPERATED. PLENUM AHU-1 AIR HANDLER UNIT. �II MANUEL DAMPER. SMOKE DETECTOR. FLEX DUCT SCHEDULE CFM FLEX SIZE 0-50 4110 51-100 6110 101-200 8110 201-400 10,10 401-600 12" 0 601-900 14" 0 901-1,300 16" H rw7 1� Wp w Q x � w 0 Q U W 0 0_ 0 O F- U Q Z 0 U DRAWN BY: DESIGN DATE: 11/211 REVISION 1: REVISION 2: SCALE: 3/32" = V-0" NOTE SIZE AND RATING OF HANGERS AND SUPPORTS SHALL BE PER LATEST "SMACNA" STANDARDS. EXTEND UP TO STRUCTURAL FRAMING SPIN -IN FITTING Wn! BUrTERFY DAMPER say - SUPPORT, WRAP STRAP TO OVERLAP 4" DEG. EXTRACTOR AND FASTEN WITH 2 SHEET METAL SCREWS ROUND °SNAP LOGK' 5HEET METAL OR SPIRAL LOCK 5EAM FOR RUN OUf5 GREATER THAN GET., OVER 6D WTH WRAP INSULATION. (SAME A5 DIFFUSER DUCT 5UPPORT A5 NECK) THREADED PER 5MACNA 5UPPORT WIRE TO PREVENT HANGER ROD STANDARD5 5AG5 R KINA5 IN FUMBLE DUCT CIU TIE DOWN TO 1"X1/16' STRAPS COMPLY WITH (TYPICAL) FL IBLE DUCT: DO NOT FBCM (2017) 301.12 5AG OR FINK INSULATED. / UNISTRUT 2' WRAP IN5ULATION: SUPPLY DUCT OUT. PIT< GLUED OVER THREE SHEET METAL SUPPLY DUCT SCREW" THROUGH WRAP IN5ULATON HELIX PDucr. SEE PLAN FOR SIZES CIG. DIFFUSER GLAMF 4 TA BAND CMP 6 TAPED CEILING OEIUNG DIff05ER RIGID DUCT HANGER AND SUPPORT DETAIL N.T.S. 5'-C" MAXIMUM NOTES' METAL STRAP 1). DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL INCHES FROM A CONNECTION BEFORE BENDING. MAXIMUM SAG 1/2" PER FOOT 1-1/2" MIN., 2). SUPPORT SYSTEM MUST NOT DAMAGE DUCT OR OF SUPPORT SPACING CAUSE OUT -OF -ROUND SHAPE. 3). ALL SUPPLY BRANCHES °MUST" HAVE A MIN. OF ° 0 2FT. DISTANCE BETWEEN EACH COWER WHEN HANGER STRAP 1.5INCH WIDE (min.) OR 12 ga. WIRE - APPLICABLE. EXCEPT BRANCHES STRAIT PERPENDICULAR ACROSS FROM EACH OTHER. MIN. 4"SLAB III 'p BMP CLIP 2X4 GALV. CLIPS PAD AT MIN. FLA PRODUCT APP.# F L 14239 APPROVED SNIP FLOOD LEVEL FLEX DUCT TIE DOWN CLIPS ONE CLIP PER CORNER T MAX, FROM END OF UNIELEVATION BOOT TAP FITTING OR MANUAL BALANCING DAMPER(MVD) SPIN -IN FITTING QUARTER TURN WITH BLADE STOPS. W/AIR SCOOP PROVIDE A HAND LOCKING QUADRANT SEAL ALL JOINTS. THAT EXTENDS APRROX. 1" OFF THE DUCT. PROVIDE WING NUT FOR LOCKING. SUPPORT STRAP C.U. MOUNTING DETAIL MIN. 1-1/2 IN WIDTH PER 5'-0" MIN. SPACING FEI SECTION 603.10.3(6) N.T.S. WIRE HANGER SUPPORTING DIFFUSER R FROM ABOVE SUPPLY INSULATED (TYPICAL) DUCT R-6 SHEET METAL INSULATED DUCT DIFFUSER INSULATED BOOT TYPICAL RIGID DUCT SUPPORT FLEXIBLE DUCT R-6 CEILING CEILING DIFFUSER TYPICAL DIFFUSER DETAIL SCALE: N.T.S. ALL THREAD ROD TO PROVIDE CLEANOUT AT EACH CHANGE TOP CHORD OF TRUSSES OF DIRECTION OR EVERY 30• /THREADED CAP 12 GA WIRE SPRING VIBRATION THREADED CAP WITH FROM HVAC UNIT HANGER (TYP.) ISOLATORS IN TOPHOLE DRILLED H VA C D E T 1 1/2" STRAP @ S' O.C. MAX DRAIN LINE. SLOPE WITH FLOW SCALE: NITS 1/8"/FT TO DRAIN GUTTER \ A° INSULATED FLEX DUCT _ a o EF o SUPPLY DUCT Curb A" Fasten Exhaust Fan units To Curb W/ #12 x 3" Tek Screws ADJUSTABLE MOUNTING FLANGES - 3" Off each Corner and 12" o/c in Field D CEILING A = FAN SUCTION PRESSURE + 1 INCH (Min. 4") 0 TYPICAL FLEX DUCT SUPPORT EXHAUST GRILLE EXH FAN DETAIL_ TYPICAL RTU CONDENSATE TRAP DETAIL SCALE: N.T.S. N.T.S. MECHANICAL DETAIL SHEET V Z �, T c 00 W m LU = M Z •_ ca •o _ ZL a •too •E cc O L6 L *+ � a° ��cniSFs02 r No. 60102 STATE OF 44 NJ Q l� c/� elA11011 THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK SPECIFIED IN THIS SECTION. PROVIDE ALL LABOR, MATERIALS, SERVICES, EQUIPMENT AND APPLIANCES REQUIRED FOR THE FABRICATION, INSTALLATION, AND/OR RENOVATION OF MECHANICAL SYSTEMS INCLUDING HEATING, VENTILATING, AIR CONDITIONING AND MISCELLANEOUS SYSTEMS AS INDICATED IN DESIGN DRAWINGS AND AS OUTLINED IN THESE SPECIFICATIONS. W6111NIMITT010 FURNISH AND INSTALL COMPLETE AIR CONDITIONING SYSTEMS AS INDICATED ON THE DESIGN DRAWINGS AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE FABRICATION AND/OR INSTALLATION OF THE SCHEDULED AIR CONDITIONING UNITS, EXHAUST FANS, AIR DISTRIBUTION AND DUCTWORK. CLEANING, TESTING AND ADJUSTING: THE MECHANICAL CONTRACTOR, AT HIS EXPENSE, SHALL CLEAN, REPAIR, ADJUST, CHECK, BALANCE, AND PLACE IN SERVICE THE VARIOUS SYSTEMS HEREIN SPECIFIED WITH THEIR RESPECTIVE EQUIPMENT, ACCESSORIES AND PIPING. HE SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS REQUIRED TO PERFORM TESTS REQUIRED BY THESE SPECIFICATIONS AND BY THE GOVERNING AUTHORITIES. NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY INSPECTED AND TESTED. TESTING: ADJUST THE AIR CONDITIONING SYSTEMS, VENTILATING SYSTEMS, FANS, ETC., TO DELIVER NOT LESS THAN THE REQUIRED AIR QUANTITY WITH QUANTITIES IN EXCESS TO BE SUBJECT TO THE APPROVAL OF THE ENGINEER IF FOUND TO NOT HAVE OBJECTIONABLE EFFECTS SUCH AS NOISE, DRAFTS, OR MOTOR OVERLOAD. PRIOR APPROVAL BY THE ENGINEER OF TESTING AND BALANCING CONTRACTOR IS REQUIRED. THIS CONTRACTOR SHALL PROVIDE THREE (3) COPIES OF A TEST AND BALANCE REPORT TO THE ENGINEER AT TIME OF SUBSTANTIAL COMPLETION INSPECTION. THE REPORT SHALL BE PREPARED BY A CONTRACTOR CERTIFIED BY ASSOCIATED AIR BALANCE COUNCIL OR NATIONAL ENVIRONMENTAL BALANCING BUREAU. THE TEST AND BALANCE REPORT SHALL BE TYPEWRITTEN AND CONTAIN THE FOLLOWING DATA: 1. DATE, TIME, WEATHER, WHEN TEST TAKEN. 2. AIR CAPACITIES AT EACH UNIT INCLUDING OUTSIDE AIR. (ENTERING AND LEAVING DB/WB) 3. STATIC PRESSURE THROUGH UNITS AND UNIT COMPONENTS. 4. MOTOR OPERATING VOLTAGE AND AMPERAGE. 5. DRIVE TYPES, SIZES AND SPEED RANGE. 6. IDENTIFICATION OF ALL AIR TERMINAL DEVICES WITH DESIGN CFM AND ACTUAL CFM. ADDITIONALLY, SYSTEMS DRAWING CLEARLY MARKED TO IDENTIFY LOCATION OF EQUIPMENT AND AIR DEVICES TESTED SHALL BE PROVIDED ALONG WITH THE WRITTEN TEST AND BALANCE REPORT. MAINTENANCE MANUALS PROVIDE COMPLETE MAINTENANCE MANUALS (3 REQUIRED) ON ALL NEW EQUIPMENT. ORGANIZE OPERATING AND MAINTENANCE DATA INTO SUITABLE SETS OF MANAGEABLE SIZE. BIND PROPERLY INDEXED DATA INTO INDIVIDUAL, HEAVY-DUTY, 2-INCH, 3-RING VINYL COVERED BINDERS WITH POCKET FOLDERS FOR FOLDED SHEET INFORMATION. MARK APPROPRIATE IDENTIFICATION ON FRONT AND SPINE OF EACH BINDER. INCLUDE THE FOLLOWING TYPES OF INFORMATION. THE INFORMATION WILL BE TURNED OVER TO THE OWNER AT TIME OF SUBSTANTIAL COMPLETION: - OPERATING AND MAINTENANCE INSTRUCTIONS - SPARE PARTS LIST - COPIES OF WARRANTIES - WIRING DIAGRAMS - INSPECTION REPORTS AND APPROVALS - SHOP DRAWINGS AND PRODUCT DATA - TEST AND BALANCE INFORMATION TRAINING SERVICES THOROUGHLY INSTRUCT THE OWNER'S REPRESENTATIVE IN THE OPERATION OF ALL EQUIPMENT FURNISHED AND LOCATION OF ALL VALVES AND CONTROL DEVICES. TRAIN BUILDING OWNER'S PERSONNEL DURING NORMAL WORKING HOURS ON STARTUP AND SHUTDOWN PROCEDURES, TROUBLESHOOTING PROCEDURES, SERVICING AND PREVENTATIVE MAINTENANCE SCHEDULE AND PROCEDURES. REVIEW WITH THE OWNER'S PERSONNEL, THE DATA CONTAINED IN THE OPERATING AND MAINTENANCE MANUALS. SCHEDULE TRAINING WITH OWNER, PROVIDE AT LEAST 7-DAYS PRIOR NOTICE TO ARCHITECT/ENGINEER. HANGERS AND SUPPORTS PROVIDE ALL NECESSARY HANGER RODS, CLAMPS AND ATTACHMENTS TO PROPERLY INSTALL AND SUPPORT DUCTWORK, PIPING AND EQUIPMENT FROM THE BUILDING STRUCTURE. PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS REQUIRED TO INSTALL EQUIPMENT, PIPING AND DUCTWORK. ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED, PRIMED AND PAINTED TO PREVENT RUSTING, FINISH COLOR AS SELECTED BY OWNER. THE USE OF BALING WIRE OR PERFORATED METAL STRAPPING IS NOT ACCEPTABLE FOR SUPPORTS. WARRANTY/GUARANTEE: THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE (1) YEAR. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ARCHITECT AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS THERETO. EQUIPMENT AND DESIGN OF SYSTEMS INDICATED ON THE DRAWINGS AND WITHIN THESE SPECIFICATIONS SHALL BE CONSIDERED AS "STANDARD OF QUALITY". NO SUBSTITUTIONS SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER. ALL EQUIPMENT SHALL BE NEW UNLESS OTHERWISE NOTED, FREE OF DEFECTS, AS SHOWN ON THE DRAWINGS OR INDICATED IN SPECIFICATIONS. DEVIATIONS FROM SPECIFIED EQUIPMENT AFFECTING ELECTRICAL REQUIREMENTS SHALL BE COORDINATED BETWEEN VENDOR, MECHANICAL CONTRACTOR, AND ELECTRICAL CONTRACTOR PRIOR TO SUBMITTING BIDS. FAILURE TO DO SO WILL NOT BE CAUSE FOR CHANGE OF BID AT A LATER TIME. IN ADDITION, THE MECHANICAL CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR ANY AND ALL CHANGES TO ENGINEERING PLANS REQUIRED BY AUTHORITY HAVING JURISDICTION. APPLICABLE CODES/STANDARDS: - 2017 FLORIDA BUILDING CODE (FBC) - 2017 FLORIDA MECHANICAL CODE (FMC) - 2017 FLORIDA PLUMBING CODE (FPC) - 2017 FLORIDA ENERGY CODE (FEC) - NFPA LATEST EDITION - SMACNA DUCT CONSTRUCTION STANDARDS - ASHRAE - 2014 NATIONAL ELECTRIC CODE (NEC) THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INSPECTIONS AND PAY ALL FEES SHOP DRAWINGS AND SUBMITTALS SUBMIT SHOP DRAWINGS AND MANUFACTURER'S DATA FOR ALL NEW EQUIPMENT FOR ENGINEER'S APPROVAL PRIOR TO PURCHASE AND/OR FABRICATION. SHOP DRAWINGS FOR EQUIPMENT REQUIRING ELECTRIC POWER OR CONTROL WIRING SHALL INCLUDE COMPLETE WIRING DIAGRAMS. HVAC CONTRACTORS SHALL SUBMIT COMPLETE DUCTWORK SHOP DRAWINGS FOR REVIEW BY THE ENGINEER. SHOP DRAWINGS SHALL INCLUDE COORDINATION WITH GENERAL CONTRACTOR REGARDING EXACT OPENINGS REQUIRED IN EXTERIOR WALLS. THE DUCTWORK SHOP DRAWINGS WILL ONLY BE REVIEWED FOR COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS. DRAWINGS WILL NOT BE CHECKED FOR COORDINATION WITH OTHER TRADES OR BUILDINGS STRUCTURE. IT IS THE RESPONSIBILITY OF THE CONTRACTORS TO COORDINATE AND VERIFY ROUTING AND EXACT LOCATION OF SYSTEM COMPONENTS. SYSTEM IDENTIFICATION PROVIDE IDENTIFICATION LABELS ON OR NEAR EACH PIECE OF MAJOR EQUIPMENT AND EACH OPERATION DEVICE AND DISCONNECT. LABELS SHALL BE CONSTRUCTED OF ENGRAVED PLASTIC LAMINATE SIGN OR PLASTIC EQUIPMENT MARKER PERMANENTLY SECURED TO EQUIPMENT. LETTERING SHALL BE A MINIMUM OF 1/2 INCH HIGH FOR EQUIPMENT NAME AND 3/8 INCH HIGH FOR EQUIPMENT INFORMATION. VALVES SHALL BE TAGGED USING PLASTIC LAMINATE TAGS SECURED WITH BRASS CHAINS INDICATING THE VALVE SIZE, SERVICE AND FUNCTION. EXECUTION ALL LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC., INDICATED ON THE DRAWINGS IS DIAGRAMMATIC AND SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE TO THE PLANS SUBJECT TO BUILDING CONSTRUCTION AND INTERFERENCES WITH OTHER TRADES. CONTRACTOR IS RESPONSIBLE FOR ANY FIELD MEASUREMENTS REQUIRED TO PROVIDE AN APPROVED AND FUNCTIONAL INSTALLATION. COORDINATE WITH OTHER TRADES AND FIELD -VERIFY EXISTING CONDITIONS FOR EXACT LOCATION AND ROUTING OF SYSTEMS. PROVIDE OFFSETS, TRANSITIONS AND ADAPTORS AS REQUIRED. NOT ALL COMPONENTS REQUIRED FOR A COMPLETE INSTALLATION ARE SHOWN ON THESE DRAWINGS. REFER TO EQUIPMENT INSTALLATION INSTRUCTION, SCHEDULES AND APPLICABLE CODES FOR ADDITIONAL INFORMATION, INCLUDING REQUIRED CONNECTION LOCATIONS, TYPES AND SIZES. PERFORM ALL WORK NECESSARY TO PREPARE THE STRUCTURE FOR THE INSTALLATION OF THE WORK. ALL HOLES, OPENINGS AND DAMAGED MATERIALS CREATED DURING CONSTRUCTION SHALL BE REPAIRED. ALL PENETRATIONS SHALL BE SLEEVED AND SEALED SO AS TO BE WATER AND AIR TIGHT. PIPING: CONDENSATE DRAINS: CONDENSATE PIPE TO BE TYPE L COPPER OR SCHEDULE 40 PVC. ROUTE AS INDICATED ON PLANS. UNITS 3 TONS AND SMALLER MAY DRAIN TO GRADE, ELSE COORDINATE WITH PLUMBER TO PROVIDE HUB DRAIN(S) IN MECHANICAL ROOM AND DRYWELL(S). HVAC CONTRACTOR TO PROVIDE P-TRAP AT UNIT SIZED FOR 2" GREATER THAN UNIT STATIC PRESSURE, PROVIDE CLEANOUT AT UNIT FOR SUSPENDED HORIZONTAL AIR HANDLERS. INSULATE CONDENSATE PIPE WITH 1/2" ARMAFLEX (OR EQUAL) INSULATION RATED FOR PLENUM APPLICATION. CONDENSATE DRAIN LINE SHALL BE NOT LESS THAN THE EQUIPMENT DRAIN LINE SIZE AND IN NO CASE LESS THAN 3/4" PIPE SIZE. DRAIN LINE SHALL SLOPE A MINIMUM OF 1/8" PER FOOT TOWARDS DRAIN. TERMINATION POINT SHALL BE COMPLY WITH FBCM 2010 SECTION 307.2 REFRIGERANT PIPING: PIPING SHALL BE FIELD FABRICATED ASTM B280 MUELLER STREAMLINE ACR OR READING HARD DRAWN FACTORY SEALED NITROGEN CHARGED SPECIAL REFRIGERATION DUTY COPPER TUBING. FITTINGS SHALL BE MUELLER OR NIBCO WROUGHT COPPER LONG RADIUS REFRIGERATION TYPE. WORKMANSHIP ON THESE SYSTEMS MUST BE GOOD, AND CLEANLINESS OF PIPING SYSTEMS IS MANDATORY. WORK THAT DOES NOT MEET THESE CRITERIA SHALL BE REMOVED AND REPLACED AT NO COST TO THE OWNER. THE ENGINEER SHALL DETERMINE WHETHER THE WORK MEETS THESE CRITERIA. COVER ALL EXPOSED LIQUID LINES AND ALL SUCTION PIPING (INDOORS AND OUTDOORS), FITTINGS, VALVES, ETC., CONTINUOUS THROUGH SLEEVES, HANGERS, ETC., WITH 3/4" FR/ARMAFLEX. INSTALLATION SHALL BE CONDENSATION FREE AND INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. PAINT ALL INSULATION EXPOSED TO OUTDOORS WITH UV PROTECTIVE PAINT PER MANUFACTURERS RECOMMENDATIONS. REFRIGERANT PIPING BELOW GRADE SHALL BE ROUTED THROUGH MINIMUM 4" DIAMETER PVC PIPE SLEEVES TO EACH CONDENSING UNIT. ALL UNDERGROUND REFRIGERANT PIPING SHALL BE CONTINUOUS SOFT DRAWN TUBING WITH NO UNDERGROUND JOINTS ALLOWED. REFRIGERANT PIPE SIZES SHALL BE SIZED PER MANUFACTURER'S RECOMMENDATION BASED ON LENGTH OF RUN BETWEEN CONDENSING UNITS AND AHU'S. VIBRATION ISOLATION: ALL BLOWER UNITS AND VIBRATING TYPE EQUIPMENT SHALL BE PROPERLY FITTED WITH MASON INDUSTRIES VIBRATION ISOLATION EQUIPMENT SIZED IN ACCORDANCE WITH EQUIPMENT WEIGHT AND DUTY PROVIDE FLEXIBLE CONNECTORS AT ALL SUPPLY AND RETURN CONNECTIONS TO AIR HANDLING EQUIPMENT CONSISTING OF HEAVY CANVAS OR NEOPRENE FABRIC WITH AIRTIGHT SEAMS AND CONNECTIONS TO THE EQUIPMENT. AIR FILTERS: FILTERS SHALL BE 1" FIBERGLASS MEDIA THROW AWAY TYPE IN A RIGID FRAME WITH A SUPPORTING MAZE ACROSS BOTH ENTERING AND LEAVING SURFACES. SUPPLY ONE COMPLETE SET OF FILTERS AFTER OWNER'S FINAL ACCEPTANCE. FARR 30/30 OR EQUAL. DUCTWORK: ALL DIMENSIONS ARE INSIDE NET FREE AREA. MATERIALS: LOW PRESSURE SUPPLY AND RETURN DUCTWORK SHALL BE FIBERBOARD EQUAL TO MANSVILLE FR-800 (SUPERDUCT). PROVIDE MINIMUM "R" VALUE OF 4.2 FOR DUCTS INSTALLED IN CONDITIONED SPACE AND 6.0 FOR DUCT INSTALLED IN UNCONDITIONED SPACE. DUCTWORK SHALL BE LINED WITH ANTI MICROBIAL COATING. SEAL ALL JOINTS WITH GLASS FABRIC AND MASTIC. TAPE ALONE IS NOT ALLOWED. MEDIUM PRESSURE DUCT SHALL BE STEEL SHEET METAL. GENERAL EXHAUST DUCTS SHALL BE GALVANIZED OR STAINLESS STEEL SHEET METAL. WET EXHAUST DUCTS SHALL BE ALUMINUM OR STAINLESS STEEL SHEET METAL. ADJUSTABLE SPUTTERS AND DAMPERS SHALL BE INSTALLED IN EVERY SPLIT AND BRANCH DUCT AND SHALL BE PROVIDED WITH LOCKING QUADRANTS ON EXPOSED OR IN ACCESSIBLE AREAS OF THE DUCT FOR EASE OF OPERATION. ACCESS PANELS OR YOUNG REGULATORS SHALL BE PROVIDED WHERE DAMPERS ARE INSTALLED ABOVE HARD CEILINGS OR IN SOFFITS. ELBOWS OR CHANGES IN DUCT DIRECTION GREATER THAN 45 DEGREES SHALL BE FITTED WITH AIR TURNS CONSISTING OF CURVED AIRFOIL BLADES OR VANES WHICH WILL PERMIT THE AIR TO MAKE ABRUPT TURNS WITHOUT APPRECIABLE TURBULENCE. FLEXIBLE DUCTWORK SHALL BE ACOUSTICAL LOW PRESSURE TYPE WITH INTERIOR LINER, METAL HELIX, FIBERGLASS INSULATION WITH AN R-VALUE OF 6.0 OR GREATER, AND COPOLYMER SEAMLESS OUTSIDE SLEEVE. THE ENTIRE FLEXIBLE DUCT ASSEMBLY SHALL BE LISTED IN ACCORDANCE WITH UL-181 CLASS 1 AIR DUCT MATERIAL. THE MAXIMUM LENGTH OF ANY FLEX DUCT SHALL BE 7'-0". FLEXIBLE DUCTWORK SHALL MEET THE FLORIDA MODEL ENERGY EFFICIENCY CODE. ALL JOINTS AT CONNECTIONS TO DIFFUSERS AND DUCTWORK SHALL BE SEALED WITH CLASS FABRIC AND MASTIC. INSTALL DUCTWORK INDICATED ON DRAWINGS, MAKING NECESSARY CHANGES IN CROSS -SECTIONS AND OFFSETS, WHETHER OR NOT SPECIFICALLY INDICATED. SPIRAL DUCTWORK SHALL BE SIMILAR TO "SEMCO" MODEL SL(85)P LOW PRESSURE. PROVIDE U.L.LISTED FIRE,SMOKE OR COMBINATION FIRE SMOKE DAMPER IN ALL PENETRATIONS OF RATED SURFACES PER APPLICABLE CODE AND IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND THE U.L. LISTING REQUIREMENTS. INTERLOCK THE UNIT WITH FIRE ALARM SYSTEM. INSULATION: SHALL BE AS MANUFACTURED BY CERTAINTEED, OWENS-CORNING, MANVILLE, PITTSBURGH CORNING, ARMSTRONG, OR APPROVED EQUAL. INSULATION SUNDRIES AND ADHESIVES SHALL BE AS MANUFACTURED BY BENJAMIN FOSTER, CHILDERS, VIMASCO, OR APPROVED EQUAL. ALL INSULATION SHALL BE SUITABLE FOR INSTALLATION IN A RETURN AIR PLENUM. INSULATE ALL SHEETMETAL DUCTWORK EXCEPT EXHAUST DUCTWORK EXTERNALLY WITH MANVILLE R SERIES MICROLITE TYPE 75 OR 100 INSULATION OR APPROVED. INSULATION TO HAVE TYPE II FSK FACING AND UL FIRE HAZARD CLASSIFICATION OF FLAME SPREAD 25/SMOKE DEVELOPED 50/FUEL CONTRIBUTED 50. INSTALL INSULATION PER SMACNA, FLORIDA MODEL ENERGY EFFICIENCY CODE AND MANUFACTURER'S RECOMMENDATIONS. ALL INSULATION JOINTS SHALL BE SEALED WITH GLASS FABRIC AND MASTIC. MINIMUM INSULATION REQUIREMENTS AS FOLLOWS: - SUPPLY AND RETURN AIR UNCONDITIONED: 2" (R-6 MIN) - OUTSIDE AIR: 2" (R-6 MIN) PIPING ROUTED ALONG BUILDING EXTERIOR WALL SHALL BE PROTECTED BY SHEET METAL HOUSING PROVIDE ALL EXTERIOR INSULATION DUCTWORK OR PIPING EXPOSED TO THE OUTDOORS WITH A MINIMUM SECURELY ATTACHED TO WALL AT 8'-0" INTERVALS AND PAINTED TO MATCH BUILDING EXTERIOR. 8 MIL THICK ALUMINUM OR PVC JACKET. TRAP OIL IN SUCTION LINE AT EVAPORATOR COIL. NO OTHER COIL TRAPS PERMITTED. PROVIDE SUCTION RISERS, CHECK VALVES, SOLENOID VALVES, OR OTHER DEVICES REQUIRED IN PIPING SYSTEM BY MANUFACTURER'S INSTALLATION INSTRUCTIONS. FURNISH ALL LABOR AND MATERIALS TO REPLACE REFRIGERANT LOST DURING THE ONE YEAR WARRANTY PERIOD. PIPE HANGERS AND SUPPORTS: PIPE HANGERS, WHERE NEEDED, SHALL BE GRINNEL #260 CLEVIS TYPE, 5'-0" ON CENTER, SECURELY ATTACHED TO BUILDING CONSTRUCTION. SPACE AT MIN. 5'-0" INTERVALS. PIPE SUPPORT: ATTACH LINES SECURELY ALONG PAD/FLOOR/EQUIPMENT/STRUCTURE TO PREVENT MOVEMENT. SUPPORT IN A MANNER THAT LINES DO NOT HANG FROM EVAPORATOR CONNECTIONS OR BLOCK ACCESS TO FILTERS, CONTROLS, ETC. SUPPORT AT MIN. 8'-0" INTERVALS FOR VERTICAL PIPES, 5'-0" FOR SUSPENDED HORIZONTAL PIPING. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ADEQUATE AND PROPER INSULATION AND MOISTURE -SEAL IN A MANNER THAT WILL PERMANENTLY PREVENT THE ACCUMULATION OF ANY OBJECTIONABLE MOISTURE ON THE EXTERIOR OF AIR CONDITIONING UNITS, REFRIGERANT PIPING, CONDENSATE DRAIN PIPING, AIR DUCTS OR OTHER PARTS OF THE SYSTEM. CONTRACTOR SHALL CORRECT THE CAUSE OF ANY CONDENSATION AND FULLY REPAIR, WITHOUT COST TO THE OWNER, ANY DAMAGES TO BUILDING SURFACES, FURNISHINGS OR EQUIPMENT CAUSED BY CONDENSATION FROM THIS SYSTEM, FOR THE FULL PERIOD OF GUARANTEE. CONTROLS: FACTORY MOUNTED CONTROL SHALL BE PROVIDED TO ACCOMPLISH THE SEQUENCE OF OPERATION. ALL INTERIOR CONTROLS SHALL BE FACTORY FURNISHED AND INSTALLED. PROVIDE ALL 24 VOLT WIRING BETWEEN CONTROL DEVICES AS NECESSARY TO MAKE COMPLETE AND OPERATION SYSTEM. PROVIDE 110/24 VAC TRANSFORMERS AS REQUIRED. COORDINATE WITH DIVISION 16 FOR 120V POWER ROUGH -IN, CONTROL, POWER AND WIRING. 24 VOLT WIRING SHALL BE PLENUM RATED CABLE. AIR CONDITIONING UNITS (DX SPLIT): UNITS SHALL BE SPLIT SYSTEM AIR-TO-AIR ELECTRIC AIR CONDITIONING UNITS AND HEAT PUMPS AS SCHEDULED ON DRAWINGS. UNITS WITH INTEGRAL ELECTRIC RESISTANCE HEATERS SHALL HAVE A SINGLE -POINT ELECTRIC CONNECTION. TOTAL COOLING CAPACITY OF THE UNITS SHALL BE AS SCHEDULED ON DRAWINGS, UNIT CABINET SHALL BE CONSTRUCTED OF GALVANIZED STEEL, BONDED AND COATED WITH BAKED ENAMEL. CABINET INSULATION SHALL COMPLY WITH FLORIDA ENERGY CODE. FANS AND MOTORS - THE INDOOR AIR FANS SHALL BE OF THE FORWARD -CURVED CENTRIFUGAL CLASS 1 TYPE. MOTOR AND DRIVE TO PROVIDE HIGHER FAN OUTPUT WHEN JOB REQUIREMENTS EXCEED STANDARD FAN CAPACITY SHALL BE PROVIDED. COOLING SYSTEM SHALL BE PROTECTED BY LOSS OF CHARGE PROTECTION, HIGH AND LOW PRESSURE SENSORS, COMPRESSOR MOTOR OVERLOADS, AND A TIMING DEVICE WHICH WILL PROHIBIT THE COMPRESSOR MOTOR FROM BEING SUBJECTED TO A STARTING CURRENT MORE THAN ONCE EVERY FIVE MINUTES. HEAT PUMP/CONDENSING UNIT INSTALLATION: PROVIDE CONCRETE PADS FOR GRADE MOUNTED CONDENSING UNITS. PADS SHALL BE A MINIMUM OF 4" THICK, 3,000 PSI CONCRETE, AND SHALL BE 4" LARGER ON EACH SIDE THAN THE FOOTPRINT OF THE CONDENSING UNIT. VERIFY UNIT DIMENSIONS WITH APPROVED SHOP DRAWINGS PRIOR TO FABRICATION OF PADS. EXHAUST FANS: FURNISH EXHAUST FANS WITH PERFORMANCE AND CAPACITIES AS LISTED ON THE DESIGN DRAWINGS. COORDINATE WITH ARCHITECT TO LOCATE EXHAUST FANS, EXHAUST GRILLES, WALL OR ROOF CAPS A MINIMUM DISTANCE OF 10'-0" FROM ANY OPERABLE WINDOW, DOOR OR FRESH AIR INTAKE. AIR DISTRIBUTION EQUIPMENT: FURNISH SUPPLY AIR GRILLES AND RETURN AIR REGISTERS WITH OPPOSED BLADE BALANCING DAMPERS AS SCHEDULED ON THE DESIGN DRAWINGS. GRILLES, REGISTERS, AND CEILING DIFFUSERS SHALL BE FURNISHED AS SCHEDULED ON THE DESIGN DRAWINGS AND SHALL BE ALL ALUMINUM CONSTRUCTION UNLESS NOTED OTHERWISE. AIR DISTRIBUTION SHALL NOT EXCEED NC-30 NOISE CRITERIA AS DEFINED IN THE LATEST ASHRAE GUIDE. MECHANICAL SPECIFICATION SCALE: NTS W U 00 3 How o=e�o�8mU'F0944 n'S�ec18 iUUN pO=jNWm x l3 CWU H��aFsiZlri Y� rz� w Z WoFF-- o}4} a'3r_Zl> kfkl U' x Z m �� W m z U 5 r Nc 15Q8 HNUOOxx_f fi Lne V J V Z r 00 W m cif) Z ca / V "(Q 0 Z �— LL uj •m Q ix Cc J L6 R* d ``*4`�� uG'UND,�,, .XCENS 3cj,: :' No: 60102 STATE OF 1c Ufa H COVERED AREA COVERED AREA COVERED AREA _ :y o 0 p: a W itF o: rn i W % Z fn O A 0 0 VI- :.i J J a Of m So C r0 J JLL W F- co r kJ f1 00 W Q ¢ Cc?, rn E :$Oaa 0 z 0 J H m 0 Oa _ rn Z o ,may o � S Z 0 LL 0 W I- C7 I t W z Z t- o O W Z o cli �00 ma0 2mo Ill❑ _ -coo wa0U)M ~ z 0 LL Z) LL �O W Z en Q p 0 Z ¢ H 0 C W C7 CL W W O Z:s 0w 00 W z J W ZR Z -1 0 m ZF- Q Lu Z- y III 0 _, WF-CS N Q S fll WCL O U)W I- W _ F =y Illa ZW Lu ZC ¢0Z00Z OOz ww00 9 z LL$ K z H S O 0 W 1 Q C J W 0) <A M 0 S U yF-Hcn < WED Um III W N O N~ W O = =- O0 FI S- LL F l� WL0 H O co W O O z W Lu o U � a w �^ LL Lu 0 Q U Lu 0 H fN E L00 PLUMBING PLAN SCALE: 3/32" = l'-0" DRAWN BY: W.J.S. DESIGN DATE: 10/24/2018 REVISION 1: DATE SHEET : PL001 REVISION2: DATE SCALE: 3/32" = 1'-0' _a...arv,_ Os. N'11-1 . ��, . ...t his CLEAR FLOOR SPACE 1 60" MIN. WATER CLOSET CLEAR FLOOR SPACE N.T.S 0 0 II z CLEAR FLOOR SPACE — 30" MIN. FN LOW e I I X� I cLeaR � I min I 6 max _ L__ _J 30 min PLAN VIEW NI-LO DRINKING FOUNTAIN DETAIL N.T.S BATHROOM EQUIPMENT LEGEND 11 SOAP DISPENSER HAND DRYER v NON ACCESSIBLE TOILET FD W/GREASE 4" SANITARY LINE TABLE 604.4 MAXIMUM FLOW RATES AND CONSUN PLUMBING FIXTURES AND FIXTURE PLUMBING FIXTURE OR FIXTURE FITTING LAVATORY, PUBLIC, (METERING) 0.25 GI LAVATORY, PUBLIC, (OTHER THAN METERING) URINAL SINK FAUCET 1.0 GA WATER CLOSET 1.6 GAI I II I a TrM 1. ALL WATER PIPING TO BE SCHED 40 CPVC. 2. PROVIDE ISOLATION VALVES TO ALL PLUMBING FIXTURES INSTALLE 3. PROVIDE BACK FLOW PREVENTION DEVICE TO ALL EQUIPMENT WAT 4. COLD WATER ONLY. 5. NO UNDER SLAB JOINTS IN WATER PIPING. 16 FD PROVIDE ISOLATION VALVES TO CW AND HW FOR MOP SINK. 7 PROVIDE WATER HAMMER ARRESTOR TO ICE CUBER MACHINE. ANITARY ALL DWV SANITARY LINES TO BE SCHED 40 PVC. ALL WORK SHALL COMPLY WITH FBC 2017 ,6TH EDITION, PLUMBING. GREASE TRAP SEWER LINE DIAGRAM N.T.S. 1` SK l I 14 I I, AV 1 � � \1�lC� p 0 p W co < 0, O •. Z F- v U A F. O z s J I- 0 � o m 1 a x z _ 7 o ~U)W3 .60 z:W O O W t W Z Z o oow O J Z o cr om °O = W � LL � O a�oo� H W 2 J n 3 z DLL �LLO W U Z H U 00 IY Z z Ua p OZ J U I - Ill z o w U w a 0 Zw Z a p Jw z(n OW m tY W O r Q2 m w O w W W = FU)L aw I zW2ooz zo 0 } o�oz LL ZO H U—' w W> Z mu U Q 0 U U I- 1- in In m } Q W Z Z Q K = UI LL K w -Uln0 (nw w0 = w o 2 S = J 7� W O co OU Quo a who LL � [w+ co I— V1 U LLIIn E-1 O O O a a rI 0 F- F- z O U PLUMBING ISOMETRIC & LEGENDS .00 SCALE: 1/4" = 1'-0" DRAWN BY: W.J.S. DESIGN DATE: 10/24/2018 REVISION 1: DATE SHEET: REVISION 2: DATE PL002 SCALE: 1/8" = V-0' TOP ELEV. OF FLOOR DRAIN ------- - \ FINISHED FLOOR I PROVIDE TRAP PRIMER CONNECTION AS REQUIRED P-TRAP MINIMUM 3/8" ALL THREADEC PLUMBING PIP INSULATED NOT TO SCALE FLOOR DRAIN WITH ADJ. BRASS STRAINER SLOPE al MAX. 12'-0" FLOOR DRAIN (FD) DETAIL SCALE:NTS ASSEMBLY 5 JCTURE ABOVE PROVIDE ONE PIECE SPUN ALUMINUM BASE WITH, GRADUATED STEPPED PVC BOOT, AND ADJUSTABLE STAINLESS STEEL CLAMPS. SET BASE IN BED OF MASTIC. MINIMUM 12" ABOVE ROOF ROOF INSULATION II II ____1 ,IIII III / III ROOF DECK PROVIDE SLEEVE IF - REQUIRES BY TYPE OF ROOF DECK 2" VENT MINIMUM 12" BELOW ROOF: B—LINE RIG. B3060 ADJUSTABLE PIPE HANGER RING B—LINE FIG. E33170 4" WASTE 1/8" SLOPE MIN.FOOT 6" THICK BY 18" SQUARE CONC. PAD. w w PROVIDE PIPE INCREASER — WHERE REQUIRED TO MAKE MINIMUM 3" VENT THRU ROOF. ANCHOR PIPE TO ROOF DECK OR JOISTS WITH U-BOLT AROUND PIPE AND ANGLE IRON WELDED OR SCREWED TO DECK OR JOIST. HUBLESS PIPE CONNECTORS ON CAST IRON PIPE OR PVC. REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VENT THRU ROOF MINIMUM TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE. PROVIDE 1" FIBERGLASS INSULATION WITH ALL -SERVICE JACKET ON VENT PIPE INSIDE BUILDING WITHIN SIX FEET OF VENT THRU ROOF LOCATION. VERIFY FLASHING AND COUNTER FLASH WITH ROOFING CONTRACTOR. VENT THRU ROOF (VTR) DETAIL NOT TO SCALE "CO" TO BE PVC IN COVER. PVC SCH 40 CLEANOUT WITH COVER FOR DUTY REQUIRED. GRADE PVC, EXTENSION SAME SIZE AS SEWER UP TO 4" DIA. PVC LONG SWEEP 1 /4" BEND OR PVC COMB, "Y" & 1/8" BEND. (USE REDUCING TYPE WHERE REQUIRED. — FINISHED FLOOR 4 44 4 PVC EXTENSION SAME SIZE AS SAN WASTE UP TO 4° DIA. �— BUILDING DRAIN OR \-- DIRECTION OF FLOW SEWER MATERIAL AND SIZE AS SPECIFIED. EXTERIOR CLEANOUT (ECO) INTERIOR FLOOR CLEANOUT (FCO (HEAVY TRAFFIC AREA) CLEANOUT (CO) DETAILS SCALE: NTS 1: Coordinate All Pipe Routing With All Other Trades Prior To Installation. Route All Piping To Avoid Ductwork, Electrical Raceways, and Building Structures. If Penetrations Through Structural Members Are Required For Plumbing Installations, Notify Architect and Structural Engineer Prior To installation To Ensure That Structural Integrity is Maintained. 2: This Contractor Shall Base His Proposal Upon The Equipment As Scheduled Or Specified, Using The Manufacturers and Model Numbers as Called For In The Specifications and Scheduled on The Drawings. 3: The Contractor Is Expected To Order All Materials In Sufficient Time To Avoid Delaying The Completion Of The Project. Delay In Deliveries Will Not Be Considered a Justifiable Reason For Submission Of Substitute Materials. 4: Route All Piping Concealed Above Ceiling, Within Walls, or In Chases Except as Specifically Noted, or In Mechanical Rooms. Piping Shall Not Be Run Thru Electrical Rooms or Closets. 5: Sleeve and Fire Stop All Penetrations Of Rated Walls, Ceilings, Floors, Etc. In Accordance With Applicable UL Standards and Local Codes To Maintain Rating. See Specifications. See Architectural Drawings For Rated Walls and Floors. 6: Pipe Routing Shown Is Schematic and Is Intended To Indicate General Routing. Plumbing Contractor Shall Provide Any Additional Offsets and Fittings Required For Proper Installation and To Maintain Clearances As 7_ ___ Plumbing General Notes FINISHED FLOOR(SEE ARCHITECTURAL DRAWINGS FOR FLOOR SLOPES) �— SLOPE - I r ADJUSTABLE DRAIN HEAD -7 - DRAIN BODY P-TRAP CONNECTION I�lli7'177 FLOOR DRAIN DETAIL ROM SINK u FLOOR SINK�THE IR GAP = TWICE PIPE DIAMETER -DOME WASTE STRAINER INDIRECT DRAIN CONNECTION DETAIL N.T.S HUM Ez'g FLOW TO a w H 8. FIXTURE : ?��ZFREOUENTLY 0� 0�og.mz9AUTOMATIC TRAP PRIMER VALVE wo;�MOUNT IN CW SUPPLY LINE OF No RE! a��a- �0 USED FIXTURE NEAR gzc3�wz�aa FLOOR DRAINS) SUPPLIED N F���wa� �a AND SHALL COMPLY WITH SECCTION 1002.4 OF FBCP. �ai0oo�xN�F� —z �Na 1/2" COPPER TUBING - RUN UNDERFLOOR �oZ TO FLOOR DRAIN(S) s- FLOOR SLAB `FLOOR DRAIN (SEE PLANS) a a Z a d. O TRAP PRIMER CONNECTION IN FLOOR DRAIN TYPICAL FOR ALL FLOOR DRAINS FD W UNLESS NOTED OTHERWISE ON DRAWINGS TRAP PRIMER (TPV) CONNECTION DETAIL NOT TO SCALE a 0 TRAP PRIMER VALVE (MAXIMUM OF 8 DRAINS) "PRECISION PLUMBING PRODUCTS" \ ° TYPE "K" SOFT SEAMLESS COPPER WITH NO JOINTS BELOW FLOOR SLAB. SLOPE AT w" PER FOOT MINIMUM TO FLOOR DRAIN CONNECT'1"1 FLOOR DR) Encountered In Field. Mounting Heights, Dimensions, and Handicapped Requirements. Back flow Prevent Complying With The Requirements Of The Standard Plumbing Code; Table 608.1. 7: All Plumbing Installation and Materials Shall Be In Strict Accordance 14: Position Roof Drains at Low Points. For Exact Location See Architectural With Ali Local, State, and Federal Codes and Applicable Standards, Drawings. 22: All Water Piping Installed in Exterior Walls Shall Be Placed On The Regulations, and Authorities Having Jurisdiction Over The Project. Interior Side Of The Wall, The Wall insulation Shall Be Placed On The 15: Plumber Shall Be Licensed By State And Local Authorities To Install Exterior Side Of The Piping. 8: Provide Access Panels To All Valves Within Chases or Above Natural Gas Piping. Non -Accessible Ceilings. Refer To Architectural Drawings For Ceiling Types. 23: Pressure Reducing Valves Shall Be Installed On Branch Lines Serving 16: Verify Invert Elevations and Exact Locations Of Sewers To Which New Fixtures And/Or Equipment When The Pressure In The Line Exceeds 60 P.S.I. 9: Install Water Hammer Shock Arrestors At Each Fixture or Battery Of Sewer Lines Are To Be Connected Before Installation. It Is Recommended That A Velocity Between 5 and 8 Feet Per Second Be Fixtures Where Required. Arrestors Shall Be Factory Fabricated. Install Maintained. Arrestors and Size Per Plumbing and Drainage Institute Standard P.D.I. 17: All Vents Through Roof Shall Be A Min. 10'-0" From Any Air Intakes. WH-201. Accepted Manufacturers, Sioux Chief, Josam, Jay R. Smith, Watts 24: Do Not Penetrate Wall Footings With Piping. Coordinate With General (NO.15 Series), Wade. Air Chambers Are Not Acceptable. 18: Plumbing Contractor Shall Install Dielectric Unions At All Connections Of Contractor To Drop Footing For Sleeved Stem Wall Penetrations As Required Dissimilar Metals. To Clear Plumbing Services Where Absolutely Necessary. 10: Site Connections Shall Be Provided On Civil Site Utilities Drawings. All Services Shown On This Set Of Plans Terminate 5'-0" From Building, Unless 19: Rough -In All Wastes And Supplies To Special Equipment In Strict 25: Fixture P-Trap Distance From Fixture Outlet To Trap Weir Shall Not Shown Otherwise on Drawings. This Contractor Shall Make All Final Plumbing Accordance With Manufactures Recommendations And Make Final Exceed 24 Inches. Service Connections To Site Work Utilities. Connections. All Supplies Shall Be Valved. Install Vacuum Breakers Where Required By Code. 26: Plumbing Contractor Shall Install Horizontal Combination Waste And Vent 11: Drainage Piping Shall Slope No Less Than 1/8" Fall Per Foot. See Systems In Strict Accordance With 2017 Florida Building Code Plumbing Specifications. 20: Submit Shop Drawings ( Including Pipe Routing and Equipment Location) Edition. To Architect/Engineer For Review Prior To The Installation or Purchasing Of 12: Furnish and Install Hose Bibbs and Wall Hydrants 24" Above Finished Any Piping And/Or Equipment. 27: Any Piping In Unconditioned Spaces Shall Be Fully Insulated And Grade/Floor And Proved Vacuum Breakers as Shown on Drawings With Protected From Freezing Temperatures. 150' Minimum Perimeter Intervals. 21: Provide 'Minimum Air Gap' as Defined In ANSI A112.1.2 For All Water 28: Absolutely No PVC or CPVC Piping Will Be Allowed In Return Air Distribution System Outlets. Where It Is Not Possible To Provide plenums. 13: See Architectural Drawings For Exact Plumbing Fixture Locations, Minimum Air Gap, The Outlet Shall Be Equipped With An Accessible 29: Indirect Waste Per FBCP 2017 802.1.1 And 801.2. TRAP PRIMER SCALE: NTS PLUMBING DETAIL SHEET