BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
'�n�ei
Date: \a�\�1711S
Contractor: �<1 �' h
Job Address: a C0)
RECEIVED
DEC 1 g 4.uio
ST. Lucie County, Permitting
Permit #: VS '35-D-1 � 1
be i ve Vie'c
Construction: (x) New Construction — Complete ( ) Existing — After Addition
I
House Infiltration Test esults SLC Climate Zone 2
CFM (50) _ `, 123 Test Date:
Volume = 6 7
ACH (50) = CFM (50) x 60 / Volume = J S Mechanical Ventilation required less than �5 ACH
Passing results must be & ACH (50) or less I (X) Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested
hour in Climate Zone 1, 2 and 3 air changes
blower door at a pressure of 0.2 inches w. g
Section 553.993(5) or (7), Florida Statutes o
approved third party. A written report of tl
provided to the code official. Testing shall I
thermal envelope.
ind verified as having an air leakage rate of not exceeding 7 air changes per
er hour in Climate Zones 3 through 8. Testing shall be conducted with a
(50 Pascals). Testing shall be conducted by either individuals as defined in
individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
results of the test shall be signed by the party conducting the test and
performed at any time after creation of all penetrations of the building
FBC, Residential i 3
Where the air infiltration rate of a dwelling unit is less tharr%air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: GFA International, In,c.
Address: 607 NW Commodity Cove, Port St. Lucie, Florida
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
%_ I
Signature:
Printed Name: , �� M� v �1Jf�e'No
q.
License/Certification #: 63P�. ! s 5L Q /