Loading...
HomeMy WebLinkAboutLETTER-RESPONSE TO LETTERAiRC H I TECTS 1 Design roue Inc. June 21, 2018 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave. Fort Pierce, Fl. 34982 (772)462-2172 RE: Permit# 1805-0781 D.R. Horton Homes Creekside Lot 29 Response Letter Please see below for response to the above listed project. 4CANNLU BY Sta/ Luciemuff, Comment 1: PLEASE ADD THE LI`1E LOAD FOR THE FLOOR AND THE LIVE LOAD FOR THE ROOF IN ACCORDANCE WITH TABLE 301.5 AND TABLE 301.6 OF THE 2017 FLORIDA RESIDENTIAL CODE-SIXTH'EDITION. Response 1: Please see Section 2 under GENERAL NOTES on sheet GN for . information on minimum superimposed floor and roof live loads. Comment 2: PLEASE ADD THE LIVE LOAD FOR THE ROOF IN ACCORDANCE: WITH TABLE 301.5 AND TABLE 361.6 OF THE 2017 FLORIDA RESIDENTIAL CODE SIXTH EDITION. Response 2: Please see Section 2 under GENERAL NOTES on sheet GN for information on minimum superimposed roof live loads. Comment 3: PLEASE PROVIDE A, DETAIL FOR THE VEHICLE BARRIER FOR APPLIANCE IMPACT PROTECTION IN ACCORDANCE WITH 1607.8.3 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDITION. Response 3: Please refer to detail 17/17A on revised sheet D4-provided with this response package. Comment 4: PLEASE SHOW AUTOMATIC GARAGE DOOR OPENER BEING. IN ACCORDANCE WITH 309.4 OF THE 2017 FLORIDA RESIDENTIAL CODE SIXTH EDITION IF APPLICABLE. Response 4: Please refer to the revised sheet' 5.1, electrical notes provided with this response package. i FILE COPY 1441 N. Ronald Reagan Blvd. • Longwood; FL 32750 • Phone: (407) 77476078 • Fax: (407) 774-4078 AA0003325 www:abdesigngroup.coin ARCHITECTS roue Comment 5: PLEASE ADD TO THE PLANS THE CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA WEATHERING AND TERMITE AREA IN ACCORDANCE WITH TABLE 301.2(1). Response 5: Please see revised sheet,2 for the climatic and geographic design criteria weathering and termite area table. Comment 6: PLEASE SHOW CERAMIC TILE IS IN ACCORDANCE WITH 702.4 OF THE 2017 FLORIDA RESIDENTIAL. CODE SIXTH EDITION. Response 6: The is no Ceramic tile used on this house. Comment 7: PLEASE SUBMIT DETAIL FOR SOFFIT INSTALLATION AS PER CHAPTER I SECTION 107 SUBSECTION 107.1 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDITION. Response 7: Soffit installation is per the Manuf Spec. We are including the Product Approval installation with .this revision package. I Comment 8: PLEASE SHOW. ON PLANS DETAIL FOR THE POST ATTACHMENT ON THE PORCH. -SEE CHAPTER.1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDITION. Response 8: Installation of the post its listed on the Framing Plan. Please refer to sheet 4D. (2) 2x12 BM. TO 6X6 POST (2) MSTA-24 & (1) HTS716. POST TO SLAB. ABU66. (TYP 2) 1 Comment 9: PLEASE REVIEW AND CORRECT ACCORDINGLY. THE ENERGY CALCULATIONS CUBIC VOI UMFJ IS DIFFERENT THEN WHAT THE PLANS INDICATE. Response 9: Please see the revised Cover Sheet and. Floor Plan sheet 2 provided with this response package for changes. Should you have any questions, please feel free to contact me. 0 Ia Florida Architbct #AR93723 1441 N. Ronald Reagan Blvd.. Longwood, FL 32750 • Phone: (407) 7.74-6078 • Fax: (407) 774-4078 AA0003325 w;ww.abdesigngroup.com