Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL SHEETBuilding Permit # CANNED Sly Owners Name MU"" Ctl Applicant Product Opening Design Product Rated Manufacturer Model# Produ to roval PP Glass Type Method of Attachment Pressure Design Pressure Number Concrete tapcon anchor, 1/4", 6" max o/c spacing in top right Swing door (+36) / (-47) (+67) / (-67) Thermo-Tru Smooth Star FL5891.2-R6 N/A and left corners, 14" max. spacing elsewhere horizontally and vertically. 11/4" embedment. Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 113/4" o/c atjamb, 16" @ head. 11/4" embedment. Type II: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max. SH Window (+38) / (-48) (+50) / (-50) Ply Gem Ply Gem 1500 FL16103.1-R9 Non Impact from corners, 7 1/4" o/c atjamb, 10 1/4" @ head. 11/4" embedment. Two additional tapcons midspan and one at lower frame required vertically each side. Install per manufacturers recommended requirements. Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from' corners, 14" o/c at jamb, 10" @ head. 1 1/4" embedment. SH Window (Integral Type If: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max. Mulled) (+38) / (-48) (+50) / (-55) Ply Gem Ply Gem 1500 FL16100.1-R6 Non Impact from corners, 8 1/2" o/c at jamb, 6" @ head. 11/4" embedment. Eight additional tapcons top and bottom required horitontally, one midspan vertically each side. Install per manufacturers recommended requirements. 1/4" concrete tapcon anchor. 2 1/2" minimum edge distance. Sliding Glass Door (+33) / (-41) (+50) / (-50) Ply Gem Builders Series FL14634.2-R3 Non Impact 6" max o/c from corners and 20 3/4" max c/o elsewhere top, 4780 vertically and bottom. 2 1/2" min embedment. 1/4" concrete screw 6" edge distance @ head, 4" edge Opaque single door distance @ jamb, 4" each side of transom centerline to with transom (+36j / (-47) (+47) / (47) Therma-Tru Smooth Star FL20461.17-R3 N/A bucking. Tapcon spacing @ 15" o/c max. @ head and jamb. Min. embedment of all anchors to be 11/4" Double Garage Door (+29) / (-35) (+46) / (-52) Overhead I Series 170, FL14170.5-R8 N/A 5/16x1-5/8" lag screw at each jamb bracket. 171,173, 174 Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" dla, heads, long enough to penetrate through plywood or 3/4" Into boards. Use 4 nails per shingle placed 6- Roof INO Cambridge F1.7006.1-1110 1/8" above the butt edge, approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. Miami -Dade approved corrosion resistant tin -caps and 12 Underlayment Interwrap i RhinoRoof U20 FL15216.1-R3 gauge 1 X" annular ring -shank nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. i the field of the roll Soffit +31.6, -38.8 (+157) / (46.1) PIYGem I Variform Soffits FL24161.1 1/4" x 20 stainless steel or ELCO Panelmate with minimum Hurricane Panels Less than 6'span (+47) / (-53) Hurricane Storm 24 GAGE FL16293-R2 embedment @ 13/4" In concrete / masonry, 2 1/2" min. edge panel MFGI distance, 12" o/c max. spacing. Can be headed screw oral] thread but with wing nuts. 1/4" x 20 stainless steel or ELCO Panelmate with minimum Hurricane Panels 6' / (-50)• Hurricane Storm , 24 GAGE FL16293-R2 embedment @ 13/4" In concrete / masonry, 2 1/2" min. edge span or more panel MF i(+45) distance, 12" o/c max. spacing. Can he headed screw or all thread but with wing nuts. Zip System stem Sheathing Huber Wall Sheathing 17147.2•R2 Install per manufacturers recommended requirements.