HomeMy WebLinkAboutPRODUCT APPROVALFlorida
r
iG�fia7'x�•1?3tm
BCIS Home { Log In { User Registration I Hot Topics
Product Approval
} USER: Public User
Product Approval Menu > Product or Application Search >
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who dev
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
I
Referenced Standard and Year (of Standard)
e-
SCANNED
BY
Sftudeftntv
t {
I Submit Surcharge i Stats & Facts { Publications '{ FBC Staff BCIS Site Map Links { Search {
st > Application Detail
FL16027-R2
ST. LUCIE COUNTY BUILDING DIVISION?
Revision REVIEWED FOR COMPLIANCE
2017 REVIEWED BY
Approved DATE i
PLANS AND PERMIT MUST BE KE ' N JOB
SITE OR NO INSPECTIONS) WILL 6E MAD€
Tri-Built Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
david.ruiz@tribuiltmg.com
David Ruiz
david. ruiz@tribuiltmg.com
David Ruiz
250 Route 17 North
East Rutherford, NJ 07073
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
C Richard Schurman
9050 Louisiana Street
Merrillville, IN 46410
rich.schurman@alliedbuilding.com
Roofing
Modified Bitumen Roof System
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166 THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
UL LLC REQUIRED BY FIELD INSPECTORS THAT
10/06/2018 MAY BE NECESSARY IN ORDER TO
John W. Knezevich, FCOMPLY WITH ALL APPLICABLE CODES.
Validation Checklist - Hardcopy Received
FL16027 R2 COI 2017 01 COI Nieminen.pdf
Standard
ASTM D6163
ASTM D6164
ASTM D6222
FM 4470
FM 4474
CONCEALED FASTENERS OR AT
Equivalence of Product Standards ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
Year
2008
2011
2011
2012
2011
FILE COPY
�M
Professional Rwqua a_Iw.
.. .,
BCIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff E BCIS Site Map ! Links Search i
Florida
ii-10%
Product Approval
rUSER: Public User
dMNEJYca
Product Approval Menu > Product or Application Search > .Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration C
Validated By
Certificate of Independence
Referenced Standard and Year (of
FL16027-112
Revision
2017
Approved
Tri-Built Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800)516-1485
david.ruiz@tribuiltmg.com
David Ruiz
david.ruiz@tribuiltmg.com
David Ruiz
250 Route 17 North
East Rutherford, NJ 07073
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
C Richard Schurman
9050 Louisiana Street
Merrillville, IN 46410
rich.schurman@alliedbuilding.com
Roofing
Modified Bitumen Roof System
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
t-1 Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
10/06/2018
John W. Knezevich, PE
i11 Validation Checklist - Hardcopy Received
FL16027 R2 COI 2017 01 COI Nieminen.odf
Standard Year
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
FM 4470 2012
FM 4474 2011
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 09/30/2017
Date Pending FBC Approval 10/08/2017
Date Approved 12/12/2017
Summary of Products
FL #
Model, Number
or Name
Description
16027.1
TRI-BUILT Modifi
d Bitumen Roof
SBS and APP modified bitumen roof systems
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16027 R2 II 2017 09 FINAL Al ER TRI-
Approved for use outside HVHZ: Yes
BUILT MODBIT FL16027-R2.pdf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The Design Pressure noted in
t iis application
Evaluation Reports
refers to one system. Refer to ER Appendi
for all systems and
FL16027 R2 AE 2017 09 FINAL ER TRI-
max. design pressures. 2.) Refer to ER Se
ion 5 for Limits of
BUILT MODBIT FL16027-R2.pdf
Use.
Created by Independent Third Party: Yes
Back Next
Contact Us :'^ 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records.
mail to this entity. Instead, contact the office by
455.275(1), Florida Statutes, effective October 1, 20
one. The emalls provided may be used for official com
address, please provide the Department with an emai
jIf you do not want your e-mail address released in response to a public -records request, do not send electronic
phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
12, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
munication with the licensee. However email addresses are public record. If you do not wish to supply a personal
4 address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
® 99 M
Credit Card
Safe
TRINITY i ERD
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPUFT RESISTANCE
n...s...,,.,. Page
1A-1
Wood
New or Reroof (Tear -Off)
A-21
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
1A-2
Woad
New, Reroof (Tear -Off) or Recover
A-21
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
18
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
5
iC
Wood
New, Reroof (Tear -Off) or Recover
C
Mech, Attached Insulation, Bonded Roof Cover
6
ID
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
6
lE 1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated Mech. Attached Base Sheet, Bonded Roof Cover
7
lE-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
B
1F
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
B
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
9
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
9
2C
Steel or Structural concrete
New Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation Mech. Attached Base Sheet, Bonded Roof Cover
10
I -iA
3A Structural concrete New or Reroof
3B Structural concrete New or Reroof
4A LWIC New or Reroof (T
N o Reroof (T
F Non, -Insulated, Bonded Roof Cover
A-1 Bonded Insulation, Bonded Roof Cover .. ., _�....e --A b...�hrinn R —4.A R—f r—,
14
1b-lb
1b
19
20
21
4B
4C
LWIC ew r-
LWIC New or Reroof (Tear -Off) E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
17•
5A
CWF - New or Reroof (Tear -Off) A-�
Bonded Insulation, Bonded Roof Cover
513
CWF New, Reroof (Tear -Off) or Recover A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
SC
CWF New, Reroof (Tear -Off) or Recover B
I Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22
SD
CWF New Reroof (Tear -Off) or Recover C
- Mech. Attached Insulation, Bonded Roof Cover
22
5E
CWF New Reroof (Tear -Off) or Recover E
I Non -Insulated Mech. Attached Base Sheet, Bonded Roof Cover
22
6A
Gypsum New or Reroof (Tear -Off) A-1
Bonded Insulation, Bonded Roof Cover
23
6B
Gypsum New, Reroof (Tear -Off) or Recover A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
24
6C
Gypsum New, Reroof (Tear -Off) or Recover C
Mech. Attached Insulation, Bonded Roof Cover
24
6D
Gypsum New Reroof (Tear -Off) or Recover E
Non -Insulated Mech. Attached Base Sheet, Bonded Roof Cover
24
7A
Various Recover A-1
Bonded Insulation, Bonded Roof Cover
25-26
7B
Various Recover F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
26
The
following notes apply to the systems outlined herein:
1.
The roof system evaluation herein pertains to above -deck roof components. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBCPpproval
documentation.
2.
Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
> Wood: Minimum 0.75-inch penetration.
> Steel: Minimum 0.75-inch penetration and engage the top flute of the
steel deck.
> Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with
fastener manufacturer's published installation instructions.
3.
Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate,
polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CIA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam
plastic, FBC Chapter 16, when installed with the roof cover.
Exterior
Research and Design, LLC. d/b/a Trinity( ERD
Evaluation Report A42970.10.12-R2 for FL16027-RZ
Certificate of Authorization #9503 6' EDITION
(2017) FBC NON-HVHZ EVALUATION
Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred
Bitumen Roof Systems; (900) 516-1485
Appendix 1, Page 1 of 26
NTINITY
1 ERD
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Secti Ion 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions.
> HA (HA): Full coverage at 25-30 Ibs%square.
> Dow INSTA STIK Qulk Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inchiwide ribbons,12-inch o.c.
> Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
> OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch1wide ribbons,l2-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced
> OlyBond Classic (OB Classic): Full coverage at 1 gal/squ re.
> ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch vide ribbons, 12-inch o.c.
> Note: When multiple layers(s) of insulation and/or coverboard are Installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing.
> Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickn Iss noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values he used to 'Increase' the DP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material I sted In the table:
> Millennium One Step Foamable Adhesive (M-OSFA): MDP '-157.5 psf (Mir. 0.5-inch thick)
> OMG OlyBond 500 (OB500): MDP -45.0 psf (Mir. 0.5-inch thick Multi -Max FA-3)
> OMG OlyBond 500 (OB500): MDP -187.5 psf (Mir. 0.5-inch thick ISO 95+GQ
> OMG OlyBond 500 (OB500): MDP -315.0 psf (Mir. 0.5-inch thick ENRGY 3)
> OMG OlyBond 500 (OB500): MDP -487.5 psf (Mir. 0.5-inch thick ACFoam 11)
➢ ICP Adhesive & Sealants CR-20: MDP -117.5 psf (Mip. 1.0-inch thick)
8. Bonded polyisocianurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum desigrj pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a quail ad design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk` carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall rreet or exceed critical design pressure determined In accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANTI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance.with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 td the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specifiiclLWC is not referenced, the minimum design mix shall he 300 psi. In all cases, the minimum top -coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2
Certificate of Authorization #9503 61e EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modifled Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 2 of 26
TRINITY i ERD
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheetllapplications.
TABLE 1: TRI-BUILT ROOF COVERS
Reference
Layer
Material
Application
BP -AA
(Base and Ply sheets, Asphalt -Applied)
Base Ply
FBC Approved ASTM
D4601, Type II
HA at 20-40lbs/square
Ply
FBC Approved ASTM
D2178, Type IV or VI
SBS-AA
(SBS, Asphalt -Applied)
Cap Ply
TriBuilt SBS Granular
HA at 20-40lbs/square
SBS-TA
(SBS, Torch -Applied)
Cap Ply
TriBuilt SBS Grantllar
< < < < <
Torch -Applied
SBS-SA
(SBS, Self -Adhering)
Base Ply
TriBuilt SA SBS Bade
Self -Adhering
Cap Ply
TriBuilt SA SBS Cap
APP-TA
(APP, Torch -Applied)
Base Ply or Ply
TriBuilt APP Smooth
< < < < <
Torch -Applied
Cap Ply
TriBuilt APP Smooth,
TriBuilt APP Granular
APP-SA
Self-Adhering)
Cap Ply
TriBuiltSAAPPCap
Self -Adhering
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MOP listings below vs. those in Table 3A
n ro
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DEcx; ADHERED INSULATION PER TABLE 3A
Option q
Primer
Vapor Barrier
Insulation Adhesive
MDP (psf)
Type
Attach
VB-1.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
-60.0
VB-2.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Insta-Stik,12-inch o.c.
-75.0
VB-3.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Millennium One Step Foamable Adhesive, 12-inch o.c.
-157.5
VB-4.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
CR-20, 12-inch o.c.
-270.0
VB-1.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
I
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-inch o.c.
-290.0
17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based o� allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL36027-R2
Certificate of Authorization #9503 6r" EDITIO (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nleminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) S16-1485 Appendix 1, Page 3 of 26
T,TRINITYIERD
TABLE 1A-1; WOOD DECKS
-NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEMTYPEA-2: MECHANICALLY ATTACHED
ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
Deck
Anchor5heet
Base Insulation
Top Insulation
Roof Cover (Note 15)
MOP
No.
(Note 1)
Type
Fasteners
Attach
Type
Attach
Type
Attach
Base Ply
Ply
Cap Ply
(Psf)
Min.0.25-inch Dens
8-inch o.c. in 4-
Deck, Dens Deck Prime,
Polyglass G2 Base,
32 ga., 1-5/8-
inch lap and 8-
(Optional)
FBC
SECU ROCK Gypsum -
Min. 19/32-
CertainTeed Glasbase,
Inch diameter
inch o.c. in
Approved,
Fiber Roof Board, Min.
(Optional)
SBS-AA,
VV_1
Inch plywood
Firestone MB Base, JM
tin caps with it
three, equally
A5TM
C3289,
HA
0.75-inch FescoBoard
HA
BP -AA
BP AA
SBS-TA,
-60.0
at max. 24-
Perma-Ply 28, Tam
a annular ringspaced,
8 '
P
P
tyP
e II OI iso-
P y
(homogeneous) or min.
g )
APP-TA
inch spans
Glass Base or
shank nails
staggered
cyanurate
0.5-inch S[ructodek
GAFGLAS #75
center rows
High Density Fiberboard
Roof Insulation
8-Inch o.c. in 4-
Min. 19/32-
Polyglass G2 Base,
CertainTeed Glasbase,
32 ga., 1-5/8-
Inch lap and 8-
(Optional)
tional) FBC
Min. Dens
(Optional)
SBS-SA,
W_2
inch plywood
Firestone MB Base, JM
inch diameter
tin caps with 11
inch o.c. In
three, equally
A{�proved,
A5TM
C1289,
HA
Deck, Dens Deck Prime,
HA
SBS-SA
e
more SBS-
APP-SA,
60
-.0
at max. 24-
Perma-Ply 28, Tamko
ga. annular ring
spaced,
ty
e II polyiso-
SECUROCK Gypsum-
5A or
SBS-TA ar
APP-TA
inch spans
Glass Base or
shank nails
staggered
nurate
Fiber Root Board
APP TA
GAFGLAS#75
center rows
6-inch o.c. in 4-
Min
. 2-inch
D-IS, OB500,
Min. 19/32-
32 ga., 1-5/8-
inch lap and 6-
A I
Foam II, III,
CR-20 or M-
Min. 0.25-inch Dens
D-IS,
SBS-AA,
in plywood
Polyglass Elastobase
inch diameter
inch o.c. in
H�Shield,
H-
OSFA, atop
Deck, Dens Oeck Prime
08500,
BP -AA
(Optional)
SBS-TA,
-60.0'
W-3
at max. 24-
or Polyglass
tin caps with 12
four, equally
Sf
ield CG,
fastener
or SECUROCK Gypsum-
CR-20 or
BP -AA
inch spans
Elastobase Poly
ga. annular ring
spaced,
Multi
-Max FA3
rows, 7-inch
Fiber Roof Board
M-OSFA
APP-TA
shank nails
staggered
odIIENRGY-3
oc
center rows
6-inch o.c. in 4-
I
Min. 19/32-
32 ga., 1-5/8-
inch lap and 6-
M(n.
ACFoam
2-inch
II, III,
D-IS, OB500,
CR-20 or M-
D-IS,
(Optional)
SBS-SA,
inch plywood
Polyglass Elastobase
inch diameter
inch o.c. in
H
Shield, H.
OSFA, atop
(Optional) Additional
OB500,
One or
APP-SA,
W.4
at max. 24-
or Polyglass
tin caps with 12
four, equally
i- C
fastener
layers of base insulation
SBS-SA
more SBS-
or
-60.0•
inch spans
Elastobase Poly
ga. annular ring
spaced,
Multi
-Max FA3
rows, 7-inch
M-OSFA
M-OS A
SA or
APP-TSBS-T
APP-TA
shank nails
staggered
lIEN
oc
APP-TA
center rows
ogENRGY-3
Exterior Research and Design, U.C. d/b/a Trinity I ERD
Certificate of Authorization #9503 6r"EDITIO (2017) FBC NON-HVHZ EVALUATION
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485
Evaluation Report A42970.10.12-R2 for FL16027-R2
Revision 2: 09/25/2017
Appendix 1, Page 4 of 26
s �
CJ TRINITYjERD
TABLE 1A-2: WOOD DECKS —ANEW
CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPEA•2: MECHANICALLY ATTACHED
ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
Deck
Anchor Sheet
Base insulation
Top Insulation
Roof Cover (Note IS)
MDP
No.
(Note 1)
Type
Fasteners
Attach
I Type I
Attach
Type
Attach
Base Ply
Ply
Cap Ply
(psf)
Min. 0.25•inch Dens Deck,
Polyglass
12-inch o.c. in 4-
(Optional)
FBC
Dens Deck Prime, SECUROCK
Min. 19/32-
Elastobase or
OMG Flat
inch lap and 12-
Apptoved,
Gypsum -Fiber Roof Board,
(Optional)
SBS-AA, SBS-
W-5
inch plywood
Polyglass
Bottom Plates
inch o.c. in two,
ASTM
C1289,
HA
Min. 0.75-Inch FescoBoard
HA
BP -AA
BP -AA
TA, APP-TA
•60.0
at max. 24
Elastobase
s uare with
(square)
equally spaced,
q y p
typed
II polyiso-
(homogeneous) or min. 0.5-
inch spans
Poly
y
Roofgrip 412
staggered center
garturate
inch Structodek High Density
rows
Fiberboard Roof Insulation
Polyglass
12-inch o.c.in 4-
(Optional)
FBC
(Optional)
Min.19/32-
Elastobase or
OMG Flat
inch lap and 12-
App
oved,
Min. 0.25-inch Dens Deck,
One or
SBS-SA, APP-
W 6
inch plywood
Polyglass
Bottom Plates
inch o.c. in two,
ASTM
C1289,
HA
Dens Deck Prime, SECUROCK
HA
SBS-SA
more SBS-
SA, SBS-TA
-60.0
at max. 24
Elastobase
(square) with
equally spaced,
hpeI
II polyiso-
Gypsum-Fiber Roof Board
SA or APP-
or APP-TA
inch spans
Poly
Roofgrip#12
staggered center
rows
ganluraol
TA
TABLE IS: WOOD DECKS-14EW
CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHEDIBASE
INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover (Note 35)
MDP
No.
Deck (Note 1)
Type
Fasteners
Attach
Type
Attach
Base Ply
Ply
Cap Ply
(psf)
Min.19/32-inch
Min.1.5-inch
Dekfast Hex with
I
1 pek
r
Min. 0.75-inch FescoBoard
(homogeneous) or min. 0.5-inch
(Optional if
(Optional if using
AA Base) One or
SBS-AA, SBS-TA,
W-7
plywood at max. 24-inch
ENRGY 3, H-Shield
Dekfast #12 or TruFast
1.33
t
Struct odek High Density Fiberboard
HA
using AA Ply)
more BP -AA or
APP-TA
-60.0
spans
or Polytherm
MP-3 with TruFast DP
Roof Insulation
BP -AA
APP-TA
Exterior Research and Design, U.C. d/b/a Trinity( ERD
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485
Evaluation Report A42970.10.12-R2 for FL16027-R2
Revision 2: 09/25/2017
Appendix 1, Page 5 of 26
QFJ
TRINITYIERD
TABLE 1C: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
' ,SYSTEM TYPE C: ,MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
Base Insulation
Top Insulation Layer
Roof Cover (Note 15)
MOP
Type I
Fasteners
Attach
Base Ply
Ply
Cap Ply
No.
Deck (Note 1)
Layer
(Psf)
Min. 19/32-inch
(Optional)
One more layers,
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or min. 0.25•
Dekfast Galvalume
1 per 1.33
(Optional if
(Optional if using AA
SBS-AA, SBS-TA, APP-
-82.5
W-8
plywood at max.
Steel Hex with
=
ft
using AA Ply)
Base) One or more BP
TA
24-inch spans
o
any combination,
inch Dens Deck, Dens Deck Prime or
Dekfast M12 DP
BP -AA
or APP-TA
loose laid
SECUROCK Gypsum -Fiber Roof Board
Dekfast Galvalume
Min. 19inch
(Optional)
One or more layers,
Min. 1.5-inch ENRGY 3, H-Shield or
Steel Hex with
1 per 1.33
SBS-SA
(Optional) One or more
SBS-SA, APP-SA, SBS-
82 5
W-9
plywoodd at at max.
any combination,
Polytherm
Dekfast M32 DP or
TruFast MP-3 with
it
SBS-SA or APP-TA
TA or APP-TA
24-inch spans
loose laid
TruFast DP
TABLE 1D: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPED: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Insulation Layer(s) I
I Base Sheet
Roof Cover (Note 15)
MDP
No.
Deck (Note 1)
Type
Attach
Base I
Fasteners
Attach
Base Ply
Cap Ply
(Psf)
Polyglass Elastobase, Polyglass
OMG Flat Bottom Plates
Min. 19/32-inch
Elastobase Poly, Polyglass G2 Base,
(square) with Roofgrip
12-inch o.c. in 4-inch lap and 12-
(Optional) One
SBS-AA,
W-10
plywood at max.
One or more layers,
Prelim.
CertainTeed Glasbase, Firestone MB
M34, Dekfast Hex with
Inch o.c. in two, equally spaced,
or more BP -AA
SBS-TA,
-52.5
24-inch spans
any combination
Attached
Base,1M Perma-Ply 28, Glass
Dekfast 414 or TruFast
staggered center rows
or APP-TA
APP-TA
jamko
Base or GAFGLAS 05
MP-3 with TruFast HD
Min.19/32-inch
One or more layers,
Prelim.
POlyglass Elastobase or
Polyglass
Dekfast Hex with Dekfast
or TruFast MP-3 with
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
One or more
SBS-SA,
APP-SA,
-52.5•
W-11
plywood at max.
any combination
Attached
Elastobase Poly with poly
top surface
T#14ruFast
TruFast HD
staggered center rows
SBS-SA
SBS-TA or
24-inch spans
APP-TA
Min. 19/32-inch
One or more layers,
Prelim.
Polyglass Elastobase or
Polyglass
OMG Flat Bottom Plates
12-inch o.c. in 4-inch lap and 12-
Inch o.c. in two, equally spaced,
(Optional) One
or more BP -AA
SBS-AA,
SBS-TA,
-60.0
W-12
plywood at max.
24-inch spans
any combination
Attached
Elastobase Poly
I
(square) with Roofgrip M12
staggered center rows
or APP-TA
APP-TA
Min.19inch
One or more layers,
Prelim.
Polyglass Elastobase or
Qolyglass
OMG Flat Bottom Plates
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
One or more
SBS-SA,
APP-SA,
-60.0•
W-13
at
plywoodd at max.
any combination
Attached
Elastobase Poly with poly
top surface
(square) with Roofgrip M12
staggered center rows
SBS-SA
SBS-TA or
24-inch spans
APP-TA
Exterior Research and Design, LLC. d/b/a Trinityl ERD Evaluation Report A42970.10.12-R2 for FL16027-R2
Certificate of Authorization M9503 6r"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 6 of 26