HomeMy WebLinkAboutBLOWER DOOR TEST FORMPlanning & Development Services FILE COPY Building & Code Regulation Division O 2300 Virginia Ave, Rm 201 ILM• s Fort Pierce, FL 34982 Phone:772-462-21�65 Fax:772-462-6443 BLOWER DOOR!TEST FORM 2G1ANNau House Infiltration Test Certification BY Prescriptive and Performance Method St U9CIP Date: 12/12/18 Permit #: Contractor: E)n_ Job Address: '6 W � (D bb LA e- i)r, i; n by - ` teyce— Pf, :S 0tL(r Construction: (>&New Construction — Complete ( ) Existing —After Addition House Infiltration Test jResults SLC Climate Zone 2 CFM (50) = Test Date: 12/12/18 Volume = ACH (50) = CFM (50) x 60 / Volume 0 2-1 Mecha ical Ventilation required less than 3 ACH Passing results must be &ACH (50) or less ( Pass ( )Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage -rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company - Company Name: GFA International, 772-924-3575 Address: 607 NW Commodity Cove, Port St. Lucie f I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance With—&@gtion R402.4.1.2 Climate Zone 2. Signature: Printed Name: Michael Anderson License/Certification #: BPI 5059963 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method 1go5z,6 83 FILE COPY Date: 12/12/18 Permit #: � 1 9 7 - 6 0/r� % Lot #: & `_ Contractor: D.R. Horton Address:Irs Construction: t Construction Test ❑ Rough -in Test Test Conditions: ( ) Date: 12/12/18 Floor Area ft2 : / Time: Primary Location of Supply Ductwork Bedrooms Indoor Temperature (F): Primary Location of Return Ductwork Hallways Outdoor Temperature (F): Total Leakage Test (Outside) Duct Leakage: ❑ Default ❑ Prop. Leak Free imposed On = <De4 FE—EZ 0 ki z) 3 b Test Pressure: -25 (Pa) CJ Baseline Duct Pressure (optional) NSA (Pa) Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: Pass ❑ Fail Installed Pa -25 74 25 Total Leakage (cfm): , 2� Total Leakage per 100 sgft: CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft. Testing Company Company Name: GFA International, 772-924-3575 Address: 607 NW Commodity Cove, Port St. Lucie FI I hereby certify that the above Duct am Leakage results demonstrate compliance with 5th Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. Signature: Printed Name: Michael Anderson License/Certificate #: BPI 5059963