BLOWER DOOR!TEST FORM 2G1ANNau
House Infiltration Test Certification BY
Prescriptive and Performance Method St U9CIP
Date: 12/12/18 Permit #:
Contractor: E)n_
Job Address: '6 W � (D bb LA e- i)r, i; n by - ` teyce— Pf, :S 0tL(r
Construction: (>&New Construction — Complete ( ) Existing —After Addition
House Infiltration Test jResults SLC Climate Zone 2
CFM (50) = Test Date: 12/12/18
Volume =
ACH (50) = CFM (50) x 60 / Volume 0 2-1 Mecha ical Ventilation required less than 3 ACH
Passing results must be &ACH (50) or less ( Pass ( )Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage -rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company -
Company Name: GFA International, 772-924-3575 Address: 607 NW Commodity Cove, Port St. Lucie f
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance With—&@gtion R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Michael Anderson
License/Certification #: BPI 5059963
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
772-462-2165 Fax 772-462-6443
FBC ENERGY CONSERVATION CODE
Duct Sealing Certification
Prescriptive and Performance Method
1go5z,6 83
FILE COPY
Date: 12/12/18 Permit #: � 1 9 7 - 6 0/r� % Lot #: & `_
Contractor: D.R. Horton Address:Irs
Construction: t Construction Test ❑ Rough -in Test
Test Conditions: ( )
Date: 12/12/18 Floor Area ft2 : /
Time: Primary Location of Supply Ductwork Bedrooms
Indoor Temperature (F): Primary Location of Return Ductwork Hallways
Outdoor Temperature (F):
Total Leakage Test (Outside)
Duct Leakage: ❑ Default ❑ Prop. Leak Free imposed On = <De4 FE—EZ 0 ki z) 3 b
Test Pressure: -25 (Pa) CJ
Baseline Duct Pressure (optional) NSA (Pa)
Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: Pass ❑ Fail
Installed Pa
-25 74 25 Total Leakage (cfm): , 2�
Total Leakage per 100 sgft:
CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft.
Testing Company
Company Name: GFA International, 772-924-3575
Address: 607 NW Commodity Cove, Port St. Lucie FI
I hereby certify that the above Duct am Leakage results demonstrate compliance with 5th Edition FBC Energy Conservation requirements in accordance with
Section R403.2.2.
Signature:
Printed Name: Michael Anderson License/Certificate #: BPI 5059963