HomeMy WebLinkAboutPRODUCT APPROVAL SHEETBuilding Permit # SGAF Ludo 10,110ank Owners Name I e..,.u.�"• Product Opening Design Product Rated Manufacturer Modelp Product Approval Glass T a Type Method Attachment Pressure Desi n Pressure Number of Concrete tapcon anchor, 1/4", 6" max o/c spacing in top right Swing door (+36) / (-47) (+67) / (-67) Therma-Tru Smooth Star FL5891.2-R6 N/A and left corners, 14" max. spacing elsewhere horizontally and i vertically. 1 1/4" embedment. Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners,113/4" a/c atjamb, 16" @ head. 1 1/4" embedment. Type 11: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max. SH Window (+38) / (-48) (+50) / (-50) Ply Gem Ply Gem 1500 FL16103.1-R9 Non Impact from corners, 7 1/4" o/c atjamb, 10 1/4" @ head. 11/4" embedment. Two additional tapcons mldspan and one at lower frame required vertically each side. Install per manufacturers recommended requirements. Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from' corners, 14" a/c at jamb, 10" @ head. 1 1/4" embedment. SH Window (Integral Type R: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max. Mulled) (+38) / (48) (+50) / (-55) Ply Gem Ply Gi m 1500 FL36100.1-R6 Nan Impact from corners, 8 1/2" o/c atjamb, 6" @ head. 1 1/4" embedment. Eight additional tapcons top and bottom required horitontally, one mldspan vertically each side. Install per manufacturers recommended requirements. 1/4" concrete tapcon anchor. 2 1/2" minimum edge distance. Sliding Glass Door (+33) / (-41) (+50) / (-50) Ply Gem Builders Series FL14634.2-R3 Non Impact 6" max o/c from corners and 20 3/4" max o/c elsewhere top, 4780 vertically and bottom. 2 1/2" min embedment. ' 1/4" concrete screw 6" edge distance @ head, 4" edge Opaque single door distance @ jamb, 4" each side of transom centerline to with transom (+36) / (•47) (+47) / (-47) Therma-Tru Smadth Star FL20461.17-R3 N/A bucking. Tapcon spacing @ 15" a/c max. @ head and jamb. I Min. embedment of all anchors to be 1 1/4" Double Garage Door (+29) / (-35) (+46) / (-52) Overhead Series 170, FL14170.5-RB N/A 5/16x1-5/e" lag screw at each jamb bracket. 171,173, 174 Use galvanized (zinc coated) roofing nails,11 or 12 gauge, with at least 3/8" dia. heads, long enough to penetrate through plywood or 3/4" Into boards. Use 4 nails per shingle placed 6- Roof IKO Cambridge FL7006.1-R10 1/8" above the butt edge, approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. Miami -Dade approved corrosion resistant tin -caps and 12 Underlayment Interwrap RhinoRoof U20 FL35216.1-R3 gauge 1'/." annular ring -shank nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. In the field of the roll Soffit , +31.5, -38.8 (+157) / (-46.1) PlyGem Variform Soffits FL24161.1 1/4" x 20 stainless steel or ELCO Panelmate with minimum Hurricane Panels Less than 6' s an (+47) / (-53) Hurricane Storm 24 GAGE FL16293-R2 embedment @ 13/4" In concrete / masonry, 2 1/2" min. edge P panel MFG. I distance, 12" o/c max. spacing. Can he headed screw or all thread but with wing nuts. 1/4" x 20 stainless steel or ELCO Panelmate with minimum Hurricane Panels 6' (+45) / (-SO) Hurricane Storm 24 GAGE FL16293-R2 embedment @ 13/4" in concrete / masonry, 2 1/2" min. edge span or more panel MFG. distance, 12" a/c max. spacing. Can be headed screw or all thread but with wing nuts. Zip System Sheathing Huber Wall Sheathing 17147.2-R2 Install per manufacturers recommended requirements.