HomeMy WebLinkAboutPRODUCT APPROVAL SHEETBuilding Permit #
SGAF
Ludo 10,110ank
Owners Name I e..,.u.�"•
Product
Opening Design
Product Rated
Manufacturer
Modelp
Product Approval
Glass T a
Type
Method Attachment
Pressure
Desi n Pressure
Number
of
Concrete tapcon anchor, 1/4", 6" max o/c spacing in top right
Swing door
(+36) / (-47)
(+67) / (-67)
Therma-Tru
Smooth Star
FL5891.2-R6
N/A
and left corners, 14" max. spacing elsewhere horizontally and
i
vertically. 1 1/4" embedment.
Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from
corners,113/4" a/c atjamb, 16" @ head. 1 1/4" embedment.
Type 11: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max.
SH Window
(+38) / (-48)
(+50) / (-50)
Ply Gem
Ply Gem 1500
FL16103.1-R9
Non Impact
from corners, 7 1/4" o/c atjamb, 10 1/4" @ head. 11/4"
embedment. Two additional tapcons mldspan and one at lower
frame required vertically each side. Install per manufacturers
recommended requirements.
Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from'
corners, 14" a/c at jamb, 10" @ head. 1 1/4" embedment.
SH Window (Integral
Type R: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max.
Mulled)
(+38) / (48)
(+50) / (-55)
Ply Gem
Ply Gi m 1500
FL36100.1-R6
Nan Impact
from corners, 8 1/2" o/c atjamb, 6" @ head. 1 1/4"
embedment. Eight additional tapcons top and bottom required
horitontally, one mldspan vertically each side. Install per
manufacturers recommended requirements.
1/4" concrete tapcon anchor. 2 1/2" minimum edge distance.
Sliding Glass Door
(+33) / (-41)
(+50) / (-50)
Ply Gem
Builders Series
FL14634.2-R3
Non Impact
6" max o/c from corners and 20 3/4" max o/c elsewhere top,
4780
vertically and bottom. 2 1/2" min embedment.
'
1/4" concrete screw 6" edge distance @ head, 4" edge
Opaque single door
distance @ jamb, 4" each side of transom centerline to
with transom
(+36) / (•47)
(+47) / (-47)
Therma-Tru
Smadth Star
FL20461.17-R3
N/A
bucking. Tapcon spacing @ 15" a/c max. @ head and jamb.
I
Min. embedment of all anchors to be 1 1/4"
Double Garage Door
(+29) / (-35)
(+46) / (-52)
Overhead
Series 170,
FL14170.5-RB
N/A
5/16x1-5/e" lag screw at each jamb bracket.
171,173, 174
Use galvanized (zinc coated) roofing nails,11 or 12 gauge, with
at least 3/8" dia. heads, long enough to penetrate through
plywood or 3/4" Into boards. Use 4 nails per shingle placed 6-
Roof
IKO Cambridge
FL7006.1-R10
1/8" above the butt edge, approx. 1" and 13" from each end
and 1/2" above each cutout. Drive nails straight so that nail
head is flush with, but not cutting into shingle surface.
Miami -Dade approved corrosion resistant tin -caps and 12
Underlayment
Interwrap
RhinoRoof U20
FL35216.1-R3
gauge 1'/." annular ring -shank nails,
spaced 6" o.c. at all laps and three staggered rows fastened 12"
o.c. In the field of the roll
Soffit ,
+31.5, -38.8
(+157) / (-46.1)
PlyGem
Variform Soffits
FL24161.1
1/4" x 20 stainless steel or ELCO Panelmate with minimum
Hurricane Panels Less
than 6' s an
(+47) / (-53)
Hurricane Storm
24 GAGE
FL16293-R2
embedment @ 13/4" In concrete / masonry, 2 1/2" min. edge
P
panel MFG.
I
distance, 12" o/c max. spacing. Can he headed screw or all
thread but with wing nuts.
1/4" x 20 stainless steel or ELCO Panelmate with minimum
Hurricane Panels 6'
(+45) / (-SO)
Hurricane Storm
24 GAGE
FL16293-R2
embedment @ 13/4" in concrete / masonry, 2 1/2" min. edge
span or more
panel MFG.
distance, 12" a/c max. spacing. Can be headed screw or all
thread but with wing nuts.
Zip System Sheathing
Huber
Wall Sheathing
17147.2-R2
Install per manufacturers recommended requirements.