HomeMy WebLinkAboutBLOWER DOOR TEST FORMQCANWtu ��-�79G BY Planning & DeveloprtIMUrot cCoilrit, Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 RECEIVED Phone:772-462-2165 Fax:772-462-6443 1010 au� o e HoOWER se InfDOORonEST TestOCerMtification peTM01n o Cou v ent Prescriptive,and Performance Method Date: 8 / 9 / 2019 Permit #: 1805-0776 Contractor: Paradise Homes Job Address: 18503 Mach One Dr, Port St. Lucie, Construction: (><) New Construction — Complete ( ) Existing —After Addition House Infiltration Test Results CFM (50) = 1905 Volume = 33450 SLC Climate Zone 2 Test Date: 8 / 8 / 2019 ACH (50) = CFM (50) x 60 / Volume = 3.42 Mechanical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less X/1 Pass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and ' erified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or indill iduals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. ►12! FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Energy House Technology Address: 3341 Pine Hill Trail, Palm Beach Gardens, FL I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements i accordan with tion R402.4.1.2 Climate Zone 2. Signature: Printed Name: Bruce Tschosik License/Certification #: RTIN: 4510152 Duct: Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Builder: Paradise Homes munity: Permit #: 1805-0776 Lot: NA Address: 18503 Mach One Dr City: Port St. Lucie State: FL Zip: 34987 System 1 12 cfm cfm25 System 2 18 cfm cfm25 System 3 cfm25 Sum of any cfm25 Total of all 30 cfm cfm25 30 cfm _ 3297 = 0.01 Qn Total of all Total Conditioned systems Square Footage PASS ❑FAIL Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. Company Name: Energy House Technology Phone: 561-459-0242 1 hereby verify that the above duct lea tind results are in accordance with the Florida Building Code requirements with the selected compliance papi as state Bove, eit r; the Prescriptive Method or Performance Method. Signature of Tester: Date of Test: 8 / 9 / 2019 Printed Name of Tester: Bruce Tschosik License/Certification #: RTIN: 4510152 Issuing Authority: FSEC/RESNET 8/9/2019 11:30:50 AM EnergyGauge@ USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1