Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEi _ FORM R405-2017 FLORIDA ENERGY EFFICIgMI Florida Department of Business and P VOE FOR BUILDING CONSTRUCTION onal Regulation - Residential Performance Method Project Name: PARADISE - HAMMER RESIDENCE I Builder Name: Paradise Homes Street: Aero Acres I S663 Mach we v¢ • Permit Office: St. Lucie Co. City, State, Zip: St Lucie Co., FL, 'piost.Wcte 3%Ra'4 Permit Number: Owner. Jeff and Lynda Hammer Jurisdiction: St. Lucie Co. Design Location: FL, ST LUCIE_CO INTL I County:: St. Lucie (Florida Climate Zone .2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2928.0 sgft.). Insulation Area 2. Single family or multiple family Single-family a. Concrete_ Block - Int Insul, Exterior R=4.1 2808.00 ft2 b. Frame - Wood, Adjacent R=1.1.0 120.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (3298.0 §oft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3298.00 f12 6. Conditioned floor area above grade (ft2) 3297 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. WA R= ft2 11. Ducts R ft2 7. Windows(601.0 sgft.) Description Area a. Sup: GREAT ROOM, Ret: GREAT ROOM, AH: G 6 300 a. U-Factor: Sgl, U=1.07 601.00 ft2 b. Sup: MASTER SUITE, Ret: MASTER SUITE, AH 6 329.7 SHGC: SHGC=0.30 b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 55.0 SEER:16.50 b. Central Unit 17.7 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 32.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 C6P:1.00 Area Weighted Average Overhang Depth: 13.943 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (3297.1 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 3297.10 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 15. Credits Pstat Total Propose Modified Loads: 102.75 Glass/Floor Area: 0.182 i PASS Total Baseline Loads: 103.70 1 1 hereby certify that the plans an speci fio s covered b� Review of the plans and Sxg7� this calculation are in complian wit a Flo da E ergy specifications covered by this O�-T%E O Code. calculation indicates compliance��„�b'j, ' _=: with the Florida Energy Code. ti rrrrrr '� PREPARED BY: DATE: I Before construction is completed this building g will be inspected for compliance with Section 558.908 'f } * E I hereby certify that this building, as designed is in compliance Florida Statutes. COD with the Florida Ener y Code. I yvs'� OWNER/AGENT: I .BUILDING OFFICIAL: DATE: I DATE: = Compliance requires certification by the air handle certified factory -sealed in accordance with R403.3 - Compliance requires an Air Barrier and Insulation ' envelope leakage test report with envelope leakage - Compliance with a proposed duct leakage Qn regi tested in accordance with ANSI/RESNETIICC 380, is 5/9/2018 4:58 PM EnergyGauge® unit manufacturer that the air handler enclosure qualifies as .1. pection Checklist in accordance with 'R402.4.1.1 and this project requires an greater than 4.00 ACH50 (R402.4.1.2). s a Duct Leakage Test Report confirming duct leakage to outdoors, t greater than 0.040 Qn for whole house. HIM E=7 #'"% #*w4`Iil PV Nw., "4a a I FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 7 FORM R405-2017 (PROJECT Title: PARADISE - HAMMER RESI Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3297 Lot # Owner Name: Jeff and Lynda Hammer Total Storiels: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Paradise Homes Rotate Angle: 0 Street: Aero Acres Permit Office: St. Lucie Co. Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie Co. Whole Hodse Fan: No City, State, Zip: St Lucie Co. , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI I 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 SYS 1 771 7710 2 SYS 2 2526 25740 I SPACES Number Name Area Volume I Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER SUITE 350 3500 No 0 3 1 No Yes Yes 2 WIC LRG 85 845 No 0 1 No Yes Yes 3 WIC SML 40 400 No 0 1 No Yes Yes 4 MASTER BATH 272 2720 No 0 1 No Yes Yes 5 TIOLET BATH 24 240 No 0 1 No Yes Yes 6 DINING FOYER 240 2880 No 0 1 No Yes Yes 7 GREAT ROOM 546 5460 No 0 1 No Yes Yes 8 DINETTE 154 1540 No 0 1 No Yes Yes 9 KITCHEN 280 2800 No 0 1 No Yes Yes 10 PANTRY 40 400 No 0 1 No Yes Yes 11 LAUNDRY HALL 130 1300 No 0 1 No Yes Yes 12 LAUNDRY 167 1870 No 0 1 No Yes Yes 13 BATH 2 85 845 No 0 1 No Yes Yes 14 BED 2 192 1920 No 1 1 No Yes Yes 15 BED 3 192 1920 I No 1 1 No Yes Yes 16 WIC BED 3 34 338 No 0 1 No Yes Yes 17 WIC BED 2 38 380 No 0 1 No Yes Yes 18 BATH 3 66 660 No 0 1 No Yes Yes 19 STUDY 272 2720 No 1 1 No Yes Yes 20 STUDY HALL 70 700 i No 0 1 No Yes Yes I I 5/9/2018 4:58 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet • 1 Slab -On -Grade Edge Insulatio MASTER SUITE 46 (`t 351 ft2 ____ 0 0 1 2 Slab -On -Grade Edge Insulatio WIC LRG III 13 84.5 ft2 -__- 0 0 1 3 Slab -On -Grade Edge Insulatio WIC SML 1 40 ft2 0 0 1 4 Slab -On -Grade Edge Insulatio MASTER BATH 30 272 ft2 ___ 1 0 0 5 Slab -On -Grade Edge Insulatio TIOLET BATH Ift 6 ft 24 ft2 _-__ 1 0 0 6 Slab -On -Grade Edge Insulatio DINING FOYER 24 ft 240 ft2 __-_ 0.5 0 0.5 7 Slab -On -Grade Edge Insulatio GREAT ROOM 18 ft 546 ft2 ___- 0 0 1 881ab-On-Grade Edge Insulatio DINETTE 16 ft 154 ft2 ____ 1 0 0 9SIab-On-Grade Edge Insulatio KITCHEN 1 ft 280 ft2 ___- 1 0 0 10SIab-On-Grade Edge Insulatio PANTRY 5 ft 40 ft2 ___- 1 0 0 11SIab-On-Grade Edge Insulatio LAUNDRY HALL 1 i ft 130 ft2 _-__ 1 0 0 12SIab-On-Grade Edge Insulatio LAUNDRY 30 ft 187 ft2 _-__ 1 0 0 13SIab-On-Grade Edge Insulatio BATH 2 6.5 ft 84.5 ft2 __-_ 1 0 0 14SIab-On-Grade Edge Insulatio BED 2 12 ft 192 ft2 -___ 0 0 1 15SIab-On-Grade Edge Insulatio BED 3 12 ft 192 ft2 -_-_ 0 0 1 16SIab-On-Grade Edge Insulatio WIC BED 3 ft 33.8 ft2 ____ 0 0 1 17SIab-On-Grade Edge Insulatio WIC BED 2 4 5 ft 38.3 ft2 -__- 0 0 1 18SIab-On-Grade Edge Insulatio BATH 3 8 ft 66 ft2 _-__ 1 0 0 19SIab-On-Grade Edge Insulatio STUDY I9 ft 272 ft2 ____ 0 0 1 20SIab-On-Grade Edge Insulatio STUDY HALL 5ft 70 ft2 _--- 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Arela Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 3571 ft2 I 0 ft2 Medium 0.9 No 0.9 No 20 22.6 ATTIC I V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3297 ft2 N N I 5/9/2018 4:58 PM EnergyGauge® USA - F aRes2017 Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER SUITE 0 Blown 351 ft2 0.1 Wood 2 Under Attic (Unvented) WIC LRG 0 Blown 85 ft2 0.1 Wood 3 Under Attic (Onvented) WIC SML 0 Blown 40 ft2 0.1 Wood 4 Under Attic (Unvented) MASTER BAT 0 Blown 272 ft2 0.1 Wood 5 Under Attic (Unvented) TIOLET BATHi 0 Blown 24 ft2 0A Wood 6 Under Attic (Unvented) DINING FOYER 0 Blown 240 ft2 0.1 Wood 7 Under Attic (Unvented) GREAT ROONj 0 Blown 546 ft2 0.1 Wood 8 Under Attic (Unvented) DINETTE 0 Blown 154 ft2 0.1 Wood 9 Under Attic (Unvented) KITCHEN 0 Blown 280 ft2 0.1 Wood 10 Under Attic (Unvented) PANTRY 0 Blown 40 ft2 0.1 Wood 11 Under Attic (Unvented) LAUNDRY HA L 0 Blown 130 ft2 0.1 Wood 12 Under Attic (Unvented) LAUNDRY 0 Blown 187 ft2 0.1 Wood 13 Under Attic (Unvented) BATH 2 0 Blown 85 ft2 0.1 Wood 14 Under Attic (Unvented) BED 2 0 Blown 192 ft2 0.1 Wood 15 Under Attic (Unvented) BED 3 0 Blown 192 ft2 0.1 Wood 16 Under Attic (Unvented) WIC BED 3 0 Blown 34 ft2 0.1 Wood 17 Under Attic (Unvented) WIC BED 2 0 Blown 38 ft2 0.1 Wood 18 Under Attic (Unvented) BATH 3 0 Blown 66 ft2 0.1 Wood 19 Under Attic (Unvented) STUDY 0 Blown 272 ft2 0.1 Wood 20 Under Attic (Unvented) STUDY HALI1 0 Blown 70 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space Tn Wall TypeFt In Ft In Are;; R-\/,qliip l7mrtonn Ahqnr a 1 N Exterior Concrete Block - Int InsMASTER SUI 4.1 6 0 10 0 60.0 ft2 0 0 0.5 0 _ 2 NE Exterior Concrete Block - Int InsMASTER SUIT 4.1 6 0 10 0 60.0 ft2 0 0 0.5 0 _ 3 SW Exterior Concrete Block - Int InsMASTER SUIT 4.1 21 0 10 0 210.0 ft2 0 0 0.5 0 4 NW Exterior Concrete Block - Int InsIVIASTER SUII 4.1 12 0 10 0 120.0 ft2 0 0 0.5 0 5 SW Exterior Concrete Block - Int InsulWIC LRG 4.1 13 0 10 0 130.0 ft2 0 0 0.5 0 6 NE Exterior Concrete Block - Int InsUASTER BA 4.1 3 0 10 0 30.0 ft2 0 0 0.5 0 _ 7 E Exterior Concrete Block - Int InsUASTER BI 4.1 5 0 10 0 50.0 ft2 0 0 0.5 0 8 SE Exterior Concrete Block - Int InsMASTER BAI 4.1 8 4 12 0 100.0 ft2 0 0 0.5 0 _ _ 9 S Exterior Concrete Block - Int InsWASTER BAI 4.1 5 0 10 0 50.0 ft2 0 0 0.5 0 _ 10 SW Exterior Concrete Block - Int InsWASTER BA 4.1 7 0 10 0 70.0 ft2 0 0 0.5 0 11 SW Exterior Concrete Block - Int InS01IOLET BAT 4.1 6 0 10 0 60.0 ft2 0 0 0.5 0 _ 12 E Exterior Concrete Block - Int Ins@INING 7 4.1 5 0 12 0 60.0 ft2 0 0 0.5 0 13 SE Exterior Concrete Block - Int InsIDINING FO Y 4.1 14 0 12 0 168.0 ft2 0 0 0.5 0 _ 14 S Exterior Concrete Block - Int Ins(DINING FOY 4.1 5 0 12 0 60.0 ft2 0 0 0.5 0 15 �16 NW I Exterior Concrete Block - Int InsGREAT ROO 4.1 18 0 10 0 180.0 ft2 0 0 0.5 0 N Exterior Concrete Block - Int InsulDINETTE 4.1 2 0 10 0 20.0 ft2 0 0 0.5 0 17 SW Exterior Concrete Block - Int InsulDINETTE 4.1 6 0 10 0 60.0 ft2 0 0 0.5 0 18 W Exterior Concrete Block - Int InsulDINETTE 4.1 4 0 10 0 40.0 ft2 0 0 0.5 0 19 NW Exterior Concrete Block - Int InsulDINETTE 4.1 4 0 10 0 40.0 ft2 0 0 0.5 0 �20 Concrete Int 0 SE Exterior Block- Insul PANTRY 4.1 4 2 12 0 50.0 ft2 0 0 0.5 5/9/2018 4:58 PM EnergyGauge® USA - FI$Res2017 Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Ornt To ace Typp Space R-Value Et in Ft in Area R_Vallfp Frnntinn Ahsnt Grade% 21 SE -Wall Exterior Concrete Block - Int InshAUNDRY H 4.1 5 0 12 0 60.0 ft2 0 0 0.5 0 22 SW Exterior Concrete Block - Int InsdLAUNDRY H 4.1 6 0 10 0 60.0 ft2 0 0 0.5 0 23 SE Exterior Concrete Block - Int InsuLAUNDRY 4.1 14 2 12 0 170.0 ft2 0 0 0.5 0 24 SW Exterior Concrete Block - Int InsuLAUNDRY 4.1 3 0 10 0 30.0 ft2 0 0 0.5 0 25 NE Exterior Concrete Block - Int Insul BATH 2 4.1 6 6 10 0 65.0 ft2 0 0 0.5 0 26 NE Exterior Concrete Block - Int Insul BED 2 4.1 12 0 10 0 120.0 ft2 0 0 0.5 0 27 NE Exterior Concrete Block - Int Insul BED 3 4.1 12 0 10 0 120.0 ft2 0 0 0.5 0 28 NE Exterior Concrete Block - Int InsLWVIC BED 2 4.1 4 6 10 0 45.0 ft2 0 0 0.5 0 29 NE Exterior Concrete Block - Int Insul BATH 3 4.1 8 0 10 0 80.0 ft2 0 0 0.5 0 30 N Exterior Concrete Block - Int Insul STUDY 4.1 4 0 10 0 40.0 ft2 0 0 0.5 0 31 NE Exterior Concrete Block - Int Insul STUDY 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 32 SW Exterior Concrete Block - Int Insul STUDY 4.1 8 0 10 0 80.0 ft2 0 0 0.5 0 33 NW Exterior Concrete Block - Int Insul STUDY 4.1 13 0 10 0 130.0 ft2 0 0 0.5 0 34 W Exterior Concrete Block - Int Ins9IrUDY HALL 4.1 5 0 10 0 50.0 ft2 0 0 0.5 0 _35 NE Garage Frame - Wood MASTER SUI 11 12 10 120.0 ft2 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood MASTER SUI None .2 .1 .1 .0 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 TIM Single (Tinted) Yes 1.07 0.3 N 32.0 ft2 30 ft 0 in 1 ft 0 in None None 2 NW 4 Metal Single (Tinted) Yes 1.07 0.3 N 55.0 ft2 15 ft 0 in 1 ft 0 in None None 3 E 7 Metal Single (Tinted) Yes 1.07 0.3 N 7.0 ft2 20 ft 0 in 1 ft 0 in None None 4 SE 8 Metal Single (Tinted) Yes 1.07 0.3 N 12.0 ft2 2 ft 0 in 1 ft 0 in None None 5 S 9 Metal Single (Tinted) Yes 1.07 0.3 N 7.0 ft2 . 2 ft 0 in 1 ft 0 in None None 6 SW 11 Metal Single (Tinted) Yes 1.07 0.3 N 7.0 ft2 2 ft 0 in 1 ft 0 in None None 7 E 12 Metal Single (Tinted) Yes 1.07 0.3 N 20.0 ft2 2 ft 0 in 1 ft 0 in None None 8 SE 13 TIM Single (Tinted) Yes 1.07 0.3 N 72.0 ft2 24 ft 0 in 1 ft 0 in None None 9 SE 13 Metal Single (Tinted) Yes 11.07 0.3 N 36.0 ft2 2 ft 0 in 1 ft 0 in None None 10 S 14 Metal Single (Tinted) Yes 1.07 0.3 N 20.0 ft2 16 ft 0 in 1 ft 0 in None None 11 NW 15 Metal Single (Tinted) Yes 1.07 0.3 N 96.0 ft2 26 ft 0 in 1 ft 0 in None None 12 SW 17 Metal Single (Tinted) Yes 1.07 0.3 N 19.0 ft2 34 ft 0 in 1 ft 0 in None None 13 W 18 Metal Single (Tinted) Yes 1.07 0.3 N 19.0 ft2 22 ft 0 in 1 ft 0 in None None 14 NW 19 Metal Single (Tinted) Yes 1.07 0.3 N 19.0 ft2 17 ft 0 in 1 ft 0 in None None 15 SE 21 Metal Single (Tinted) Yes 1.07 0.3 N 15.0 ft2 2 ft 0 in 1 ft 0 in None None 16 SE 23 Metal Single (Tinted) Yes 1.07 0.3 N 24.0 ft2 2 ft 0 in 1 ft 0 in None None 17 NE 25 Metal Single (Tinted) Yes 1.07 0.3 N 7.0 ft2 2 ft 0 in 1 ft 0 in None None 18 NE 26 Metal Single (Tinted) Yes 1.07 0.3 N 25.0 ft2 2 ft 0 in 1 ft 0 in None None ' 19 NE 27 Metal Single (Tinted) Yes 1.07 0.3 N 25.0 ft2 2 ft 0 in 1 ft 0 in None None 5/9/2018 4:58 PM EnergyGauge® USA - I FI Res2017 Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2017 - I WINDOWS Orientation shown is the entered, Pro osed orientation. / 1/ # Wall Ornt ID Frame Panes Overhang NFRC SHGC Imp Area Depth Separation Int Shade lactor Screening 20 21 22 NE 29 Metal Single (Tinted) Yes 11.07 0.3 N 7.0 ft' 2 ft 0 in 1 ft 0 in None NW 33 Metal Single (Tinted) Yes 11.07 0.3 N 55.0 ft' 2 ft 0 in 1 ft 0 in None W 34 TIM Single (Tinted) Yes 11.07 0.3 N 22.0 ft' 2 ft 0 in 1 ft 0 in None None None None GARAGE # Floor Area Ceiling Area E6osed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1215ft2 1215ft2 I 115ft loft 1 INFILTRATION i # Scope Method I SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000258 2229.2 122.38 230.15 .1933 4 HEATING SYSTEM i # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None COP:1 32 kBtu/hr 1 None COP:1 17 kBtu/hr 2 sys#1 sys#2 CIOOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ None I SEER: 16.5 55 kBtu/hr 1650 cfm 0.75 1 None I SEER: 16 17.7 kBtu/hr 531 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location I EF Cap Use SetPnt Conservation 1 Electric None LAUNDRY 10.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name I Collector Storage System Model # Collector Model # Area Volume FEF None None ftZ DUCTS I / v # ---- Supply --- Location R-Value Area -- Return --- Air CFM 25 CFM25 Location I Area Leakage Type Handier TOT OUT QN RLF HVAC # Heat Cool 1 2 GREAT ROO 6 300 ftZ MASTER SUI 6 329.7 ft GREAT ROO B2.45 ft Proposed Qn GREAT RO --- cfm 30.8 cfm 0.04 0.60 MASTER SUI 82.425 Proposed Qn MASTERS --- cfm 101.0 cfm 0.04 0.50 1 1 2 2 I - I i I I 5/9/2018 4:58 PM EnergyGauge® USA - IaRes2017 Section R405.4.1 Compliant Software Page 6 of 7 , FORM R405-2017 TEMPERATURES Programable Thermostat: Y Ceiling Fans - Cooling [[ ]] Jan Feb [[ Mar r ] A r [ ] May X Jun [X] Jul Au Se [ ]Oct [[ ]]Nov r Dec Heatin(X] Jan X Feb [X� Mar [ ] Apr [ ] May Jun [ ] Jul Au rj �Xj Sep [ j Oct [X] Nov Dec Ventin [[ ]] Jan (( Feb [[X] Mar [[[XXXII A r [ ]] Ma' i [ Jun t [ ] Jul Aug Se [X))) Oct [[Xl]l Nov [[[[ Dec L Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 178 78 78 78 78 80 80 80 80 PM 80 80 78 8 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 �8 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/9/2018 4:58 PM EnergyGauge® USA - F IaRes2017 Section R405.4.1 Compliant Software Page 7 of 7 FORM '41 1 : 4A, ENERGY Py DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. I$5o3 AAAa-1 ar-w- M, Ps%- IF-L. 3qq%:1 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Sgl, U=1.07 SHGC: SHGC=0.30 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A Aero Ac I New (From Plans) Single-family 3 No 3297 Insulation R=0.0 R= R= I I i I Area I 601.00 ft2, i ft? I ft2 I ft2 13.9431ft. 0.300 Area 1 3297.10 ft2 I ft2 I ft2 I certify that this home has complied with the Flori Construction through the above energy saving fez in this home before final inspection. Otherwise, a based on installed Code compliant features. Builder Signature: Address of New Home: 7 , St Lucie Co., FL, 9. Wall Types Insulation a. Concrete Block - Int Insul, Exterior R=4.1 b. Frame - Wood, Adjacent R=11.0 c. N/A R= d. N/A R= 10. Ceiling Types Insulation a. Roof Deck (Unvented) R=20.0 b. N/A R= c. N/A R= 11. Ducts a. Sup: GREAT ROOM, Ret: GREAT ROOM, AH: G b. Sup: MASTER SUITE, Ret: MASTER SUITE, AH 12. Cooling systems a. Central Unit b. Central Unit 13. Heating systems a. Electric Strip Heat b. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits a Energy Efficiency Code for Building Tres which will be installed (or exceeded) ew EPL ispiay Card will be completed Date: 1 b 1J City/FL Zip: S�, t✓t,�G1 Area 2808.00 ft2 120.00 ft2 ft2 ft2 Area 3298.00 ft2 ft2 ft2 R ft2 6 300 6 329.7 kBtu/hr Efficiency 55.0 SEER:16.50 17.7 SEER:16.00 kBtu/hr Efficiency 32.0 COP:1.00 17.0 COP:1.00 Cap: 50 gallons EF: 0.95 Pstat k��i3OJJp% %E Fi :Z 1� fill �;d �0D W-B *Note: This is not a Building Energy Rating; If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. I • **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. • I I 5/9/2018 4:58 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 I I 6 1A - AIR CON�6 TIO bY/II— Project Summary' SYS 2 I Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com For: PARADISE Notes: HAMMER RES. Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 30411 Btuh Ducts 9413 Btuh Central vent (94 cfm) 2908 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 42732 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg Cooling Area (ftZ)2526 2526 Volume (ft') 25735 25735 Air changes/hour 0.24 0.13 Equiv. AVF (cfm) 104 56 Heating, Equipment Summary Make CARRIER Trade Model 10 KW AHRI ref Efficiency 100AFUE Heating input 0 kW Heating output 0 Btuh Temperature rise 0 OF - - Actual air flow 1990 cfm Air flow factor 0,050 cfm/Btuh Static pressure 0 in H2O Space thermostat Job: Date: Jan 26, 2018 By: LINDSTROM Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 32007 Btuh Ducts 6972 Btuh Central vent (94 cfm) 1558 Btuh Blower 0 Btuh Use manufacturer's data n Ratelswing multiplier 0,95 Equipment sensible load 38510 Btuh Latent Cooling Equipment Load Sizing Structure 2924 Btuh Ducts 4430 Btuh Central vent (94 cfm) 3947 Btuh Equipment latent load 11302 Btuh Equipment total load 49811 Btuh Req. total capacity at 0.75 SHR 4.3 ton Cooling Equipment Summary Make CARRIER Trade Cond CA16NA060 Coil F134CNP061 AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16.5 SEER 41000 Btuh 14000 Btuh 55000 Btuh 1990 cfm 0.051 cfm/Btuh 0 in H2O 0.78 Calculations approved by ACCA to meet 'all requirements of Manual J 8th Ed. i 2018-May-09 17:01:40 A A`;--�- wrightsoft• Right -Suite® Universal 2013 13.0.12 RSU08398 Page 2 ..OJECTS ENERGYIA- MANUAL JIPARADISE , HAMMER.rup Calc = MJ8 I Front Door faces: N