Fl- FL17022-117
Application Type Revision
Code Version 2017
Application Status Approved
RECEIVED
MAY 31 2018
ST, Lucie County, Permitting
Comments
08/18/2017v. date reapply 08/21/17
Archived
r-;
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phan
CONCEALED FASTENERS OR ATTACHMENTS
2160 SW Pama Drive;
Palm City, FL 34990
ARE THE RESPONSIBILITY OF THE
(772) 872-8034
CONTRACTOR OR RECORD
flvalidation@yahoo.com
Authorized Signature
Richard McKuhen
fiva tidation@ya hoo.coni
Technical Representative
Richard McKuhen
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
I richard@emfab,net THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
Quality Assurance Representative
REQUIRED BY FIELD INSPECTORS THAT
Address/Phone/Einail
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Category
Rooting
Subcategory
Metal Rooting
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
L.-3 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
LOCKE BOWDEN 1.
PE-49704
Keystone Certifications, Inc.
04/22/2024
Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
FL1__707.2 R7 CO.F FL 17022.1 V f,R7MP sar.odf
Referenced Standard and Year (of Standard)
Standard
FILE
COPY
U«807
Equivalence of Product Standards
Certified By
Sections from the Code
YPPX
2003
2012
2006
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR COMPLIANCE
REV'
EWED,BY
DATE
PLANS AND PERMIT MUST BE KEPT JOB
SITE OR NO INSPECTION(S) WIL MADE
RitiME,' ' 41i r
Compliant with Florida Building Cod- -r -,:
Compliant with.EViK70_-
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1S07.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" rein. thru deck or 5/8" embedment intojwood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment); #10 x 1-1/2" Hex -Washer Bead wood screw* to
penetrate 3/16" ruin. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements
UnderlaVment: To be compliant with F8C Sec: Chart 1507.1.1
Install Details: Table A Allowable Loads
METHOD 1
1 METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURES
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" o.c.
16" O.C.
8" O.C.
6" o.c.
FASTENER SPACING (ALONG Panel width)
12" O.C.
12" o.c.
12" O.C.
12" O.C.
FASTENER SIZE
#9
#10
#10
#f10
Reference Data: ARCHITECTURAL TESTING;, INC. TST ID#: 1527
UL 580-06 & 1897-041 Test Report D[5893.01-450-18 OS/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897--04 is equivalent to test standard Ui.1897-12 *Design
pressure margin of safety 2.1
Locke Bowden, P.E. does not have, not will acquire a financial i . y� cq d re m��wfacturing or distributing products
under this evaluation. . a
Locke Bowden, P.E. is not owned, operated, or controlled by al2y coeiparN;)n'1bb9 aftureP, or listributing products under this
report. ,
o
7 O
0dr hti=m ffia �'� .ti.
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel a Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ad,
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6tn ed., Chapter 22 , for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
v
pegs:
15t..T or greater Pt gal, or
Wood pfarvk.
-- Fasteners
99 x 1.1m Min. or
910-1-112" M n., perTaSie A' for Rove S-V Olnv Roof Pant
Spacing and Design Pressures
Hex Washer Head Wood Screws
-- — 247
—.—....I.._...—....._�_—...., e
Nominal 12" Nominal 12"
0.0. O.C.
\ / Fasten
B x 1-1.2"Min. or ;910 X 1-112"Min. per
'Table "A" Hex Washer Head Screw
Pane! Spaced 12" o.c. across the panel Wdth
iieferto Table "A" for Spacing Along, Panel
Overlap Length
Deck-15132" or greater
Plywood, or
-Mod plank
I
. ��� f,�'T t;7s'� 5' ""�-,r � i�� a r�•s-•- .�"� � � � , _ �, ,.F, �� � .
y+a
'is'�'.w'�":srr��ME ,��
BCIs None j ! og In 1 UserRegistration ttor 7oplcs i Submit Sunouc stars & Fact.,i publications 1 FBC. Staff y BCIS Site tap Link. ; Search
US£R: Product Approval
Pn611C U5pr I RECEIVED .
yt��,. hn.le tl .lr;�mvat M1L••tn> j?r,. u<s; or Hpghc%sUan _s^srci a;: 41 .ton l ;t I Application Oetaii MAY 31 2018
� G J FL # FL16048-116
Application Type Revision ST. Lude County, Permitting
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Add ress/Plione/E mai i
Quality Assurance Representative
Address/Phone/Einail
Tri-Built Materials Group, LLC
i
1'0 Box 70
Rutherford, NJ 07070
(B00)516-1485
david, ruiz@tribuiitmg, co m
David Ruiz
aavid.ruiz@tribuilting.com
David Ruiz
i250 Route 17 North
East Rutherford, NJ 07073.
1(201) 642-2449
david.ruiz@tribuiltmateriaisgroup.com
I
Category Roofing
Subcategory Underlayments
I
Compliance Method i Evaluation Report from a Florida Registered Architect or a Licensed
1 Florida Professional Engineer
i i.. Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
07/18/2020
Validated By
John W. Knezevich, PE
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
, validation Checklist- Hardcopy Received
':i:Z 4 8 Rb .'Oi 2017 01 CO! Nieminen.nc#f
Standard
Year
ASTM D1970
2015
ASTM G155
2005
FM 4474
2011
FRSAfTRI April 2012 (04-12)
2012.
UL.1897
2012
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 10/01/2017
Date Pending FBC Approval IW03/2017
Date Approved 12/12/2017
Summary of Products,
FL #
Model, Number or Name I
Description
1604,$.1
TRI-13UILT Roof Underlayments
Self -adhering, modified bitumen roof underiayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
F160,48 R6 It ?017 09 FIN& :R, TR1-
Approved for use outside HVHZ: Yes
T 1 nL&y.;E:I'_7yi,TG1: &R'u!'fF
Impact Resistant: N/A
Verified By. Robert Nieminen PE-59166
Design Pressure: +N/A/-150 I
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -on tale systems overtop the self -adhering
FL16048 R(3 .A - It � 0-1 )I NAi, i RT
underlayment for one particular application. See ER Sectionp•1f
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Use.
Created by Independent Third Party: Yes
Ilaok ENext
Contact Us.:: 260I. Blair Stone Road. Tallohnssee F1 32399 phone: 850-487-1824
The State or Florida is an AW'EF.0 employer. Copyright 2007-201I3 State rf Florida, :: privacy Statement•:.4,�essibilily statement :: ge6rnd Statement
Under Florida law, email addresses are public. records. If you do not wtlnt your e-mail address released in response to a public -records request, do not'send electronic
matt to this entity. Instead, contact tile office by phone or by traditional mall. If you have any questions, please contact 650.487.1395. *Pursuant to Section 455,275
(1), Florida Statutes, effective Dcmber 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with,art email address If they have one. The
emails provided may be usrd for official communicatidn with the license, iioweveremail addresses am public record. If you do not wish to supply a personal address,
please provide the Department with an emaitaddress which call be mi de available to the public. To determine if you are a licensee under Chapter 455, F:S.,please
click here .
Product Approval AA�cc�ee�pts:
. i E "1 to
s ERD
EVALUATION REPORT
TRI-BUILT Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800)516-1485
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
3.53 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report A42960.10.12-R6
FL16048-R6
Date of Issuance:10/25/2012
Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing. the use of
construction materials in the State of Florida. The documentation•submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underiayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nierinen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
•;r`s ?= L
Florida Registration No. 59166, Florida DCAANE1983
The facsimile seal appearing eras authorized hY Roixrt Nieminrn,
P.E. on OG/29/2027, This does not serve as an electronically signed
dccumant.
CEnTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2, Trinity ERD is not owned, operated or controlled by any company manufacturing of distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial. interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
F e�
TRINITY i ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlaymenis, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of fhe 6th Edition (2017) Florida Building Code through testing.
in accordance with the following Standards. Compliance is subject to the'Installation Requirements and Limitations /
Conditions of Use set forth herein. I
2. STANDARDS:
Section
1.504.3.1
1504.3.1
1504.6
1507.2.4 / 1507.1.1, 1507.2.9.2
1507.3.3
I REFERENCES:
EntitV
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
UL, LLC. (QUA9625)
UL, LLC. (QUA9625)
Property
Wind Resistance
Wind Uplift
Accelerated Weathering
Physical Properties
Physical Properties
Examination
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Accelerated Weathering
Wind Resistance
Quality Control
Quality Control
Standard
FM 4474
UL 1897
ASTM G155
ASTM D1970
FRSA/TRI April 2012 (04-12)
Reference
S40540.02.13-1
S40540.11.13
S40540.03.14
S44870.04.14-2
S44870.04.14-3
S44870.04.14-1
S44870.04.14-4
543530.02.14-1-R1
S43530.05.14
540540.10.14
SC7645.02.15
SC8520.04.15
SC14045.05.17-R1
Multiple -Listing R16814
Service Confirmation
Year
2011
2012
2005
2015
2012
Date
02/19/2013
11/19/2013
03/26/2014
04/02/2014
04/02/2014
04/10/2014
04/10/2014
05/14/2014
05/28/2014
10/31/2014
02/13/2015
OS/27/201S
06/07/2017
12/10/2015
Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a, self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, U.C. Evaluation Report A42960:10.12-R6
Certificate of Authorization N9903 6" EDITION (2017) FBC NON-HVHZ EVALUATION PLI6048-R6
TRI-BUILT Roof Underlaymenis; (800).516-1485 Revision 6: 09/25/2017
Page 2 of 6
!
r
RINITY {E D
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof .cover where the product is
specifically referenced within FBC approval documents.- If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE RoorCovf IiP710N i f
v.,
j Asphalt
Underlayment
Nail -On Tile
; Foam -On Tile
Metal
Wood Shakes
Slate
i Shingles
& Shingles
Tri-Built Sand-R SA Shingle Yes
No
No
No
Yes
Yes
Underlayment
I--_.._..__....._..—._...._ ....,.._ _ ...................
.............__....__......._..........._.._.......----
i
Tri-Built 5/A HT TU
Yes
yes
I Underlayment
Yes
See 5.5.1
Yes
Yes
Yes
T i-fsuittSt ootil MiSfA j Yes
No
No
Yes
_.
Yes
I Yes
nder, yr eiZt
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
� xis �' TABCEIA ALl.OWABLETlLE%ABHESnlE{ UNDERCAYNIEAlTCQ BttiIATtOIVS�` ""` r
Adhesive
Florida Product Approval Underlayments
ICP Adhesives Polyseta AH-160
FL6332 i Tri-Built 5/A HT TU Underlayment
DowTileBond`"
FL22525 Tri-BuiltS/A HT TU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
"v Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle .Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
I Refer to 7-le Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC, Evaluation Report A42960.10.12•R6
Cerrlffcare of Authorization #9503 O' EDITION (2017) FOC NON44VkZ EVALUATION rLIG048-RG.
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/1017
Page 3 of 6
TRINITY ERD
5.6.3 Bond to Mechanically Attached Base Layer;
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or-Tri-Built Smooth HT S/A
Underlayment applied to:
A ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI Apr -I 2012 (04-12) and are used in foam -on the
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A ol,
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure=-45.0 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer:
(Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer:
Soprema Eiastocol 600c
Underlayment:
Tri-BuiltS/A HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be, driven flush with the surface. All sharp
splinters and wood project)ons,shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction,
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 15175.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-BuiltS/A HT TU Underlayment, self -adhered.
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-RG
Certificate of Authorization N9503 6" EDrnoN (2017) FBC NON-HVIiZ EVALUATION FLIGM-R6
TRI-BUILT Roof Underlayments; (800) SIG-1485 Revision 6: 09/25/2017
Page 4 of 6
g,-
V.
ERD
E
5.&4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WI31, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10-1 of FM loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayrnent in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only Abe exceeded by using battens during loading of the roof
tiles.
�, 'TABLE
Z Ttc>r SLIP,PAC�E LEMITA"TIOi�S FOR DIRECf"f�E�KsTILE
1lU5TALtAT1QNS
.,
4 "� r...?; �., „ , ; ;^ .. '
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Fiat
Max. 10-tile stack 6:12
Lugged
Max.10-tile stack 5:12
Max.10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
c n slope, as shown below)
Tri-Built S/A HT TU
Underlayment
f
Lugged
�A
I
d �e
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6` {EQn1ON (2017) F8C NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800),516-1485 Revision 6: 09/25/2017
Page 5 of 6
3
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the.substrate (if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials ;Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch oX.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Tri-Built S/A HT TU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a mannler that prevents the slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
EMtP_rior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6Y" EDITION (2017) FSC NON-FiVHZ EVALUATION FL15048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 6 of 6