Loading...
HomeMy WebLinkAboutICC-ES EVALUATION REPORTwI^ AD,IA JJ _I 1 DIVISION:08 00 00—OPENINGS SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS OWN 12 2019 Permitting Department tv St. Lucie County REPORT HOLDER: FLOOD FLAPS®, LLC EVALUATION SUBJECT: FLOOD FLAPS® AUTOMATIC FLOOD VENTS: MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05 ICC ICC ICC "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence" A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. i There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to a product covered b the report. aeo 17065 p m' p y re iso p amducl co'"wtfoo Body 01000 Copyright 0 2018 [CC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-3660 Reissued September 2018 This report is subject to renewal September 2019. www.icc-es.oru 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—VentslFoundation Flood Vents REPORT HOLDER: FLOOD FLAPS®, LLC EVALUATION SUBJECT: FLOOD FLAPS® AUTOMATIC FLOOD VENTS: MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2018, 2015, 2012 and 2009 International Building Code® (IBC) ■ 2018, 2015, 2012 and 2009 lntemational Residential Code® (IRC) Properties evaluated: ■ Physical operation ■ Water flow ■ Weathering 2.0 USES Flood Flaps® automatic flood vents are used to provide for the equalization of hydrostatic flood forces on exterior walls. Certain models also allow natural ventilation. 3.0 DESCRIPTION 3.1 General: Flood Flaps® automatic flood vents are engineered mechanically operated flood vents (FVs) that automatically allow flood waters to enter and exit enclosed areas. The FVs are constructed of ABS plastic which serves as the FVs housing, and a front grill that contains an anodized metal screen imbedded in polypropylene plastic. On contact with rising flood water, the grill will disengage from its secured position, allowing flood water and debris to flow through in either direction. The FVs are available in two series as described in Section 3.3. The sealed series models contain two rubber flaps that close the FV to the passage of air when using with conditioned areas or sealed crawl spaces. In the same manner as the grill, the two rubber flaps are pushed open by water pressure, allowing water and debris to flow through the FV in either direction. See Figure 1 for an illustration of the Flood Flaps® automatic FV. 3.2 Engineered Opening: The Flood Flaps° automatic FVs comply with the design principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 (2018 and 2015 IBC and IRC) [Section 2.6.2.2 of ASCE/SEI 24-05 (2012 and 2009 IBC and IRC)] for a rate of rise and fall of 5 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Flood Flaps® automatic FVs must be installed in accordance with Section 4.0. 3.3 Flood Vent Series Models: Flood Flaps® automatic FVs are available in two series with multiple models and sizes as described in Table 1. The sealed series models, designated FFWF, include two rubber flaps for the prevention of air flow. The multi- purpose series, designated FFNF, omits the rubber flaps. 3.4 Natural Ventilation: Flood Flaps® automatic FV models FFNF12, FFNF08, FFNF05, and FFNF02 have metal screens with 114 inch by 1/4 inch (6 mm b�r 6 mm) openings and provide 37 square inches (0.02 m) of net free opening to supply natural ventilation for under -floor ventilation. Flood Flaps® automatic FV models FFWF12, FFWF08, and FFWF05 have not been evaluated for use as openings for under- floor ventilation. 4.0 DESIGN AND INSTALLATION Flood Flaps® automatic FVs are designed to be installed into walls of existing or new construction. Installation of the FVs must be in accordance with the manufacturer's instructions, the applicable code and this report. Flood Flaps® automatic FVs can be installed in wood, masonry and concrete walls up to a thickness of 12 inches (305 mm). In order to comply with the engineered opening design principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 (2018 and 2015 IBC and IRC) [Section 2.6.2.2 of ASCE/SEI 24-05 (2012 and 2009 IBC and IRC)], the Flood Flaps® FVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one FV for every 220 square feet (20 m2) of enclosed area. ■ Below the base flood elevation. ■ With the bottom of the FV located a maximum of 12 inches (305 mm) above grade. 5.0 CONDITIONS OF USE The Flood Flaps® automatic flood vents described in this report comply with, or are suitable alternatives to what is ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement o the subject o there report or a recommendation or its use. There is no warran .r I f P .% ry by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to airy product covered by the report Copyright0201B ICC Evaluation Service, LLC. All rights reserved. Page 1 of ESR-3560 I Most Widely Accepted and Trusted Page 2 of 4 specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Flood Flaps® automatic FVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict, the instructions in this report govern. 6.2 The Flood Flaps® automatic FVs must not be used in place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015 (editorially revised October 2017). 7.0 IDENTIFICATION 7.1 The Flood Flaps® models recognized in this report are identified by a label bearing the manufacturer's name, the model number, and the evaluation report number (ESR-3560). 7.2 The report holders contact information is the following: FLOOD FLAPS®, LLC POST OFFICE BOX 1003 ISLE OF PALMS, SOUTH CAROLINA 29451 (843) 881-0190 www.floodflaps.com infoOfloodflaps.com TABLE 1—FLOOD FLAP AUTOMATIC FLOOD VENT MODEL SIZES MODEL NUMBER MODEL DESIGNATION ROUGH OPENING (Width X Height) (inches) VENT SIZE (W X H X D) (inches) ENCLOSED AREA COVERAGE (fe) N FREE AREA OP ING' in) FFWF12 Sealed Series 16 x 8 15 /s X /4 X 12 220 NA FFNF12 Multi -Purpose 16 x 8 15 /s X /4 X 12 220 37 FFWF08 Sealed Series 16 x 8 15 /e x 7 /4 x 8 226 NA FFNF08 Multi -Purpose 16 x 8 15 /8 x 7314 x 8 220 37 FFWF05 Sealed Series 16 x 8 15518 x 7 /4 x 5 220 NA FFNF03 ultiiPurpose 16 x $ �1.'5rlsTx}7a/��x{5� �220� For SI: 1 inch = 25.4 mm; 1 ff 1.093 m` 'For under -floor ventilation only. FIGURE 1—FLOOD FLAPS® AUTOMATIC FLOOD VENT ESR-3560 I Most Widely Accepted and Trusted Page 3 of 4 FRgFI . FFNF08 FIGURE 2—FLOOD FLAPS" AUTOMATIC FLOOD VENT SERIES MODELS FFNF05 0 12" DEPTH 8" DEPTH 5" DEPTH FIGURE 3—FLOOD FLAPS® AUTOMATIC FLOOD VENTS MULTIPLE DEPTH OFFERINGS IMES Evaluation Report ESR-3560 FBC Supplement Reissued September 2018 This report is subject to renewal September 2019. www.icc-es.ora 1 (800) 423-6587 1 (562) 699-0643 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: FLOOD FLAPS®, LLC EVALUATION SUBJECT: FLOOD FLAPS® AUTOMATIC FLOOD VENTS: MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Flood Flaps® automatic flood vents, recognized in ICC-ES master evaluation report ESR-3560, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2017 Florida Building Code —Building ■ 2017 Florida Building Code —Residential 2.0 CONCLUSIONS The Flood Flaps flood vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-3560, comply with the Florida Building Code —Building and the Florida Building Code —Residential, provided the design and installation are in accordance with the 2015 International Building Code® provisions noted in the master report. Use of the Flood Flaps flood vents has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code -Building and the Florida Building Code —Residential. For products falling under Florida Rule 9N-3, verification that the report holder's quality -assurance program is audited by a quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued September 2018. ICC ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed as an endorsement of the subject of the report or a recommendation for'its use. There is no warranty by ICC Evaluation Service, LLC, express or implied as to arty finding or other matter in this report, or as to any product covered by the report. niEwu oxu aacamxx Copyright© 2018 [CC Evaluation Service, LLC. All rights reserved. Page 4 of 4