PRODUCT APPROVAL
Automatic Transfer Switches SOMILU GENERACO BY �t�uciP('rnrnt� . Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Single Phase C @us LISTED In the USA uft doreaft and foreIgn pub *CUL only applies to non -service rated switches Description Generac Automatic Tr fer Switches are designed fir use with single phase generators that utilize an Evolution TM or NexusT"' Controller. The 100, 00 and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipmen rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RTSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 311 enclosure"`, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The -controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. * Non -service rated (RTSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), t ese switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When rased in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation effic'ent power management options available. A �zSO f GENERAC® 100-400 Amps, Single Phase Functions All timing and sensing functions originate in the generator controller Utility voltage drop-out................................................................ Timer to generator start............................................................... Engine warm up delay................................................................. Standby voltage sensor................................................................ Utility voltage pickup.................................................................... Re -transfer time delay.................................................................. Engine cool -down timer............................................................... Exerciser..................................................................................... The transfer switch can be operated manually without power appli *When used in conjunction with units utilizing Evolution- contra Specifications Automatic Smart Transfer Switches .............................................................................................................................................. <60% ...........................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer* ........................................................................................................................................5 seconds ...........................................................................................................................60% for 5 seconds ................................... ........................................................................................................... > 80% ......................................................................................................................................15 seconds ......................................................................................................................................60 seconds ..................................................................................................................12 minutes every 7 days Model RTSC100A3 RTSW100A3RTSW150A3 RTSC200A3 RTSW200A3 RTSW300A3 RTSC400A3 RTSW400A3 Amps 100 100 I 150 200 200 300 400 400 Voltage 120/240,1e 120/240,1e 120/240, 1e 120/240,10 120/240,1e 120/240, 19 120/240,1e 120/240, to Load Transition Type (Automatic) Open Transition Open Transition Service Rated O�en Transition Service Rated Open Transition Open Transition Service Rated Open'Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 313 NEMA/UL 3R *MA/UL 311 NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 311 NEMA/UL 311 UL Rating UUCUL UL UL UUCUL UL UL UUCUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug Range 1/0 - #14 250 MCM - #6 1600 MCM - #4 or 1/0 - 250 MCM Dimensions Model RTSC100A3 R`rSW100A3 RTSW150A3 RfSC200A3 RTS 200A3 RTSW300A3 R`rSC400A3 R`rSW400A3 Height H1 17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.7 /679.4 42.91/1089.9 31.25/793.8 42.91/1089.9 (in✓mm) H2 20/508 20/508 30/762 20/508 30n62 48/1219.2 36/914.4 48/1219.2 Width W1 12.5/317.5 12.5/317.5 10.5/266.7 12.5/317.5 10.5/266.7 16.69/423.9 19.18/487.2 16.69/423.9 (in✓mm) W2 14.6/370.8 14.6/370.B 13.5/342.9 14.6/370.8 13.5I342.9 21.82/554.2 24/609.6 21.82/554.2 Depth (in✓mm) 7.09/180.1 7.09/180.1 6.3/160.1 7.09/180.1 6.3/1II60.1 10.06/255.5 10.06/255.5 10.06/255.5 Weight (Ibs./Idlos) 2019.07 22.5/10.21 39/17.69 20/9.07 39/1p.69 140/63.5 133/60.33 140/63.5 GENERAC® DEPTH DEPTH Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2015 Generac Power Systems,) Inc. All rights reserved. All wecirica8ans are subject to change without notice. Ide8n 00205-8 Printed in U.S.A. 07/28/11 Protector° Series INCLUDES: • Two -Line LCD Multilingual Digital E, Controller (English/Spanish/French, with external viewing window for ee generator status and breaker posit! • Capability to be installed with 18" ( building* • True PowerTM Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1 % Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed Note: 25-45 kW units are field convertible between natural gas or liquid propane. 60 kW units are built per fuel requirement and are not convertible. GENERAL' RECEIVED JUN 0 6 2019 ST. L.UCIC County, Permitting PROTECTOR® SERIES Standby Generators Liquid -Cooled Gaseous Engine It Standby Power Rating Model RG025 (Aluminum - Bisque) - 25 kW 60 Hz itionT"" Model RG030 (Aluminum - Bisque) - 30 kW 60 Hz rtuguese) Model RG036 (Aluminum - Bisque) - 36 kW 60 Hz indication of Model RG045 (Aluminum - Bisque) - 45 kW 60 Hz Model RG060 (Aluminum - Bisque) - 60 kW 60 Hz mm) of a ST.LUCIE COUNTY PLAN REVIEW o o _ GENp= DATE: EL.EC -Fe — �uMB; DAM - HEM. E1� QUIEf DATE �o xvmesaeiw5nutry nly if located away from doors, Meets EPA Emission Regulations r ndows, and fresh air intakes, and 25,30 & 45 kW CA/MA emissions compliant less otherwise directed by local codes. applicable for 25kW and 30kW units only. 36 & 60 kW not for sale in CA / MA FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. GENERAC'S success in "IMPROVING POWER BY DESIGN." But, it This state: -of -the -art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing, reliability all Generac models. It provides optimized FAST RESPONSE to changing testing, environmental testing, destruction and life testing, plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA, NEMA, EGSA, and other standards, allows you to electronically torque -matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at ±1 %. systems will provide superior performance. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: v PROTOTYPE TESTED NEMA MG1-2F EVALUATION O GENERAC TRANSFER SWITCHES. Long life and reliability are • SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. y P GENERAC® 25.30.36• GENERAC® IIIIIIIN 45 • 60 kW application & engineering data GENERATOR SPECIFICATIONS Type Synchronous Rotor Insulation Class H Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct VOLTAGE REGULATION Type Electronic Sensing Single Phase Regulation t 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation -±- 0.25`9a ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 15 Amp 12 Volt 30 Amp - 25 & 30 kW 36, 45 & 60 kW Static Battery Charger 2 Amp Recommended Battery (battery not included) Group 26, 525CCA System Voltage 1 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated All models fully prototyped tested ENCLOSURE FEATURES Aluminum weather Ensures protection against other nature. protective enclosure Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade Quiet, critical grade muffler is mounted' inside the unit muffler to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures aluiet operation. (All ratings in accordance with BS5514, ISO3046, IS08528, SAE J1349 and DIN6271) ENGINE SPECIFICATIONS: 25 & 30 kW Make Generac Model In -line Cylinders 4 Displacement (Liters) 1.5 Bore (in/mm) 3.05/77.4 Stroke (in/mm) 3.13/79.5 Compression Ratio 11:1 Intake Air System Naturally Aspirated Lifter Type Hydraulic ENGINE SPECIFICATIONS: 36, 45 & 60 kW Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bore (in/mm) 3.41/86.5 Stroke (in/mm) 3.94/100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (36 & 45 kW) or Turbocharged/Aftercooled (60 kW) Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge 4/3.8 - 25, 30, 36 & 45 kW Crankcase Capacity (qUl) 5.25/4.96 - 60 kW ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven 2484 - 25 & 30 kW Fan Speed (rpm) 1865 - 36 & 45 kW 2100 - 60 kW 17.7/449.6 (25 & 30 kW) or Fan Diameter (iNmm) 22/558.8 (36, 45 & 60 kW) Pusher (25 & 30 kW) or Fan Mode Puller (36, 45 & 60 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water column/9-26 mm HG LP Fuel Pressure 11 -14" Water Column NG Fuel Pressure 5 -14" Water Column a 25.30.36. 45.60kW GENERATOR OUTPUT VOLTAGEAW - 60 Hz GENERACO. operating data kW i PG I Amn LPG kW Nat_ Gas Amn Nat. Gas CB Size (Both) 120/240 V,10,1.0 pf 25 104 25 104 125 RG025 120/208 V, 30, 0.8 pf 25 87 25 87 100 120/240 V, 30, 0.8 pf 25 75 25 75 90 120/240 V,10,1.0 pf 30 I 125 30 125 150 RG030 120/208 V, 30, 0.8 pf 30 104 30 104 125 120/240 V, 30, 0.8 pf 30 I 90 30 90 100 120/240 V,10,1.0 pf 36 150 36 150 175 1201208 V, 30, 0.8 pf 36 125 36 125 150 RG036 120/240 V, 30, 0.8 pf 36 108 36 108 125 277/480 V, 30, 0.8 pf 36 54 36 54 60 120/240 V,10,1.0 pf 45 188 45 188 200 120/208 V, 30, 0.8 pf 45 I 156 45 156 175 RG045 120/240 V, 30, 0.8 pf 45 135 45 135 150 277/480 V, 30, 0.8 pf 45 68 45 68 80 120/240 V,10.1.0 pf 60 250 60 250 300 120/208 V, 30, 0.8 pf 60 208 60 208 250 RGO60 120/240 V, 30, 0.8 pf 60 180 60 180 1 200 277/480 V, 30, 0.8 pf 60 90 1 60 90 1 100 SURGE CAPACITY IN AMPS Voltage Dip @ < 114 pf 15% 30% RG025 120/240 V, 10 65 1 0 120/208 V. 30 80 1 �0 120/240 V, 30 69 112 120/240 V, 10 75 100 RG030 120/208 V, 30 96 145 120/240 V, 30 83 134 120/240 V, 10 105 240 120/208 V, 30 44 1 �0 RG036 120/240 V, 30 38 1115 277/480 V, 30 20 fill 120/240 V, 10 105 240 120/208 V, 30 44 130 RG045 120/240 V, 30 38 111,5 277/480 V. 30 20 60 120/240 V, 10 140 320 RGO60 120/208 V. 30 70 210 120/240 V, 30 61 182 277/480 V, 30 30 9� Note: Fuel pipe must he sized for full load. For Btu content, multiply W/hr x 2520 (LP) or W/hr x 1000 (NG) For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 ( G) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. ENGINE FUEL CONSUMPTION Natural Gas Propane W/hr) (m3/hr) (aal/hr) (1/hr) W/hr) Exercise cycle 60 1.7 0.7 2.5 24 25% of rated load 220 6.3 2.9 9.1 88 RG025 50% of rated load 297 8.4 3.3 12.3 119 75% of rated load 362 10.3 4 15 145 100% of rated load 430 12.2 4.7 17.8 1 172 Exercise cycle 60 1.7 0.7 2.5 24 25% of rated load 240 6.8 2.6 10 1 96 RG030 50% of rated load 320 9.1 3.5 13.3 128 75% of rated load 400 11.4 4.4 16.6 160 100% of rated load 492 14 5.4 20.4 197 Exercise cycle 65 1.8 0.7 2.6 25 25% of rated load 210 6 2.3 8.6 83 RG036 50% of rated load 380 10.8 4.2 15.7 151 75% of rated load 545 15.5 5.9 22.4 216 100% of rated load 730 20.7 8 30.1 290 Exercise cycle 65 1.8 0.7 2.6 25 RG045 25% of rated load 210 6 2.3 8.6 83 50% of rated load 380 10.8 4.2 15.7 151 75% of rated load 545 15.5 5.9 22.4 216 100% of rated load 730 20.7 8 30.1 290 Exercise cycle 123 3.5 1.34 5.1 49.3 25% of rated load 267 7.6 2.7 10.5 101 RG060 50% of rated load 483 13.7 5 19 183 75% of rated load 672 19.1 7 26.5 255 100% of rated load 862 24.5 9 33.9 1 327 STANDBY RATING: Standby ratings apply to installations served by a re fable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with SO-3046-1. Design and specifications are subject to change without notice. GENERAC® 25.30.36. 45.60kW ENGINE COOLING operating data 25 kW 30 kW 36 kW 45 kW 60 kW Air flow (inlet air including alternator and combustion air in cfm/cnrm) 2490/70.5 2490/70.5 2725/77.2 2725/77.2 3280/92.9 System coolant capacity (gal/liters) 2/7.6 2/7.6 2.5/9.5 2.5/9.5 2.5/9.5 Heat rejection to coolant (BTU per hr/MJ per hr) 112,000/118.2 135,000/142.4 193,000/203.6 193,000/203.6 270,000/284.9 Maximum operation air temperature on radiator CC/°F) I 60/140 Maximum ambient temperature (°C/°F) 50/122 COMBUSTION REQUIREMENTS Flow at rated power (cfm/cmm) 1 I 62/1.8 1 72/2 1 144/4.1 1 144/4.1 1 180/5.1 SOUND EMISSIONS Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 59 59 1 61 1 61 1 65 Sound output in dB(A) at 23 ft (7 m) with generator operating at no{mal load* 1 72 1 73 1 70 1 73 1 72 *Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfm/cmm) 203/5.7 1 237/6.7 1 300/8.5 1 420/11.9 1 494/14 Exhaust temperature at muffler outlet (°C/°F) 593/1100 1 610/1130 1 579/1075 1 593/1100 1 566/1050 ENGINE PARAMETERS Rated Synchronous rpm 1 1 3600 1 POWER ADJUSTMENT FOR AMBIENT Temperature Deration..........................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 IF above 77 IF Altitude Deration (25, 30, 36 & 45 kW).............................................................................1 % for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Altitude Deration (60 kW)............................................................................................... 1 % for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft CONTROLLER FEATURES Two -Line Plain Text LCD Display...................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto............................................................ ................................................................................Automatic Start on Utility failure. 7 day exerciser Off.........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual........................................................................................ Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds...............................................................................................................................................10 sec Standard Engine Start Sequence ............................ .............................I... .... ........ ............................................ Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration) EngineWarm-up....................................................................................................................................................................................................................5 sec EngineCool-Down.................................................................................................................................................................................................................1 min Starter Lock-out................................................................... ............................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartBattery Charger...................................................................................................................................................................................................... Standard Automatic Voltage Regulation with Over and Under Voltage Protection ................................................................................................................................ Standard AutomaticLow Oil Pressure Shutdown.............................................................................................................................................................................. Standard OverspeedShutdown............................................................................................................................................................................................. Standard, 72 Hz HighTemperature Shutdown.............................................................................................................................................................................................. Standard OvercrankProtection......................................................................................................................................................................................................... Standard SafetyFused.....................................................................................................................................................................................................................Standard Failureto Transfer Protection.............................................................................................................................................................................................. Standard LowBattery Protection.......................................................................................................................................................................................................Standard 50 Event Run Log................................................................. ............................................................................................................................................. Standard FutureSet Capable Exerciser................................................ ............................................................................................................................................. Standard IncorrectWiring Protection................................................... ............................................................................................................................................. Standard InternalFault Protection....................................................................................................................................................................................................Standard CommonExternal Fault Capability........................................ ............................................................................................................................................. Standard GovernorFailure Protection...............................................................................................................................................................................................Standard AIR INTAKE BATTERY I2 RADIATORIEXHAUST BOTH SIDES) GROUP 26 DISCHARGEAIR NEGATNE GROUND (BOTH SIDES) 865.6I28 — P 077483 CENTER OF GFiAVRY (SEE NOTE 5) RADIATOR FILL CAP RAOIAT� I DISCHARGE AR ZUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE TOP VIEW _f WA vI w Ka 0 00 0 N O W SERVICE ITEM 1.51. NOTES: OIL FILL CAP EITHER DOOR Q OIL DIP STICK RIGHT DOOR 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43') WIDE X 1887 (74.3`) LONG. OIL FILTER RIGHT DOOR REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. N 2. ALLOW SUFFICIENTROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE OILDRAINHOSE RIGHT DOOR AND SERVICING. THIS UNIT MUST BE INSTALLED INACCORDANCE WITH CURRENT RADIATORDRAW HOSE RIGHT DOOR APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, AIR CLEANER ELEMENT RIGHT DOOR STATE, AND LOCAL CODES. 3. CONTROL PANEL/ CIRCUIT BREAKER INFORMATION: SPARK PINGS RIGHT DOOR �.��_ - - SEE SPECIFICATION SHEET OR OWNERSMANUAL -MUFFLER SEE NOTE 12 r I •`-?� -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS FAN BELT EITHER DOOR:, THE STUB4IP AREAS AS FOLLOWS: BATTERY RIGHT DOOR -HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION REFERENCE OWNERS MANUAL t� NEUTRAL CONNECTION. BATTERY CHARGER 120 VOLT AD (0.5AMP MAX) CONNECTION. FOR PERIODIC '+'- - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. REPLACEMENT PART LISTINGS. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. S. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. LS'" ti 7. EXHAUST SYSTEM MAXIMUM BACK PRESSURE 24INCHES H2O. B. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. e? MOUNTING BOLTS OR 6TUDS TO MOUNTING SURFACE SHALL BE 58-11 GRADE 5 ..vc�..,.. �r...,,n /—LIFTING PROVISION(4 PLACES) SEE NOTES 5, B AND LEFTSIDEVIEW CENTER OF GRAVITY DIMENSIONS. *U of `REAR ENCLOSURE 1. COVERPANEL —`' SEE NOTE IRCUIT BREAKS i [7�9e>7IiL'S� I [ SEE NOTE 3 SEE NOTE4 — 778 OVERALL WIDTH REAR VIEW WEIGHT DATA ENGWEIIKW ENCLOSURE MATERIAL WEIGHT GENSET ONLY KG (LBS) WEIGHT SMIPPWG SKID KG (LBS) SHIPPING WEIGHT KG ILBSI 1.6125KW ST 382I885) 301661 422 J931l 1.BIdOKW ST 408I895) .1661 436 P611 1.SL7l5KW AL 352 VM 301661 3821843 1.SL130KW AL 1 36618071 301601 396I6731 tU. MUST ALLOW FREE FLOW OF INTAKE AIR. DISCHARGE AIR AND EXHAUST. SEE SPEC V.. SHEET FOR MINIMUM AIR FLOW --MAXIMUM RESTRICTION REQUIREMENTS. 11. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 12. EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE ENCLOSURE TO ACCESS EXHAUST MUFFLER CIRCUIT BREAKER NEUTRAL AND CUSTOMER CONNECTION OPENING 48 119 TYP sp W OC G 25 A 30 kW K A "O z I'0 2 I �i w b GENERAC® installation layout Drawing #OK8420-B (2 of 2)