Loading...
HomeMy WebLinkAbout1006-0186 ENGINEERING OF RECORDSUSTAINABLE EARTH ENGINEERING C. SCANNED 8528 SW Kansas Ave By Stuart, FL 34997 q f 01 I1%10 On1 tv Saint Lucie County Code Compliance Division 2300 Virginia Avenue, Fort Pierce, F 34982 Re: Permit Application # 1006-01 6 Engineer of Record for Repairs & Waterproofing Atlantic View Beach Club Co dorm 5047 N AIA, Fort Pierce, FL 04949 Dear Saint Lucie County Building To maintain structural integrity and 1 will be initiated in July, 2010. Roger be the engineer of record. The inspections scheduled for this pt installation of shoring should it be re preparation. The first inspection will of steel reinforcement corrosion. Are inspection and sounding. The contra( chipping hammers. The special inspe contractor, will determine the extent The second inspection will be upon anticipated that nominal shoring to s Structural shoring is not anticipated. 12 July 2010 g value, a repair and waterproofing project , Florida Professional Engineer 43855, will ;ct will be upon the identification of a repair area, upon ired, and at the conclusion of the reinforcement cur when the contractor identifies degradation in the form if interest were pre -identified for the contractor by visual r will expose these areas by pneumatic or electric )r or inspectors representative, working with the the repairs to be performed. installation, and only when this is required. It is A form will be needed for balcony edge spalling. The third and final inspection will be the completion of steel surface preparation prior to the installation of repair mortar. The repa r location and extent will be documented by photograph, given distinct repair identifier, and wi 1 be annotated on a simplified diagram of the balcony (threshold, beam, or column). The inspection records will be forwarded to the building department upon completion of the project. Note that sliding glass doors and thre., It was included in the contract for the possible; but has not been validated. 'I necessary to accomplis'a this, will be i Smc ly," er V b'. r ' ofessional Engineer orida,-43855 work has been identified as part of the scope of work. )se of completion. The necessity for threshold work is cold and sliding glass door work, and the steps 3sed if and when required. Atlantic View Beach Club Page 1 of I Engineer of Record Letter BREITENBACH ENGINEERING, INC 9073 SE Bridge Rd, #A, Hobe Sound, July 13, 2010 TO: Building Official St. Lucie County Building Division 2300 Virginia Avenue Fort Pierce, Florida 34982 RE: Building Inspection for Project: Concrete Repairs and Atlantic View Beach C 5047 N Al A Ft Pierce, FL 34949 jbach442@comcast.net 33455 Tel/Fax: (772) 546-6809 Cell: (772) 834-4743 Building, Permit Application #1006-0186 terprooting Condominium This letter is to inform you that thresho'Id building special inspector, John Breitenbach PE 59770, will be performing Threshold Building Inspection services for the upcoming structural restoration project at the above referenced location. Insp ction work will be performed as required according to specifications and letter of SustainablelEarth Engineering, Inc (engineer of record), dated 7-12-10. My threshold building special inspectoe' number is 2072: firm registration #26001. Occasional, the following will be authorized by me to perform inspections: Roger Baber, PE #43855. I will be sending you copies of inspection reports and a final inspection report when the project is completed. The following will be part of the final records: 1. Photographs, with unit # and 2. Field notes and sketches. 3. Special repair details or sketi Should you have any Respectfully, ``�`�w�O• DnC�/CCU ' B `14P�4� Nsi.. a �° '• STATE OF �•�'• FIOR1OP �`'/011f A1. John D. Breitenbach, , of all repairs. (if required). contract me. FL PE #59770, FL SI #2072, Firm Reg.1 #26001 Via Mail: 1-hard copy, signed and sealed (to St Lucie Co) e-mail: pdf format, to St Lucie Co Bldg Qept- cicioi@stlucieco.or file= 10025-3-Atlantic View BCC Atlantic View BCC Letter of Intent.doc SUSTAINABLE EARTH ENGINEERING $ 8528 SW Kansas Ave Stuart, FL 34997 Saint Lucie County Code Compliance Division 2300 Virginia Avenue, Fort Pierce, F 34982 Re: Permit Application # 1006-01 Engineer of Record for Repairs & Waterproofing Atlantic View Beach Club Cc 5047 N AlA, Fort Pierce, FL Dear Saint Lucie County Building To maintain structural integrity and 1 will be initiated in July, 2010. Roger be the engineer of record. The inspections scheduled for this pr installation of shoring should it be re preparation. The first inspection will of steel reinforcement corrosion. Are inspection and sounding. The contra( chipping hammers. The special inset contractor, will determine the extent The second inspection will be upon anticipated that nominal shoring to s Structural shoring is not anticipated. 12 July 2010 0 g value, a repair and waterproofing project , Florida Professional Engineer 43855, will *t will be upon the identification of a repair area, upon iced, and at the conclusion of the reinforcement cur when the contractor identifies degradation in the form if interest were pre -identified for the contractor by visual r will expose these areas by pneumatic or electric )r or inspectors representative, working with the the repairs to be performed. installation, and only when this is required. It is a form will be needed for balcony edge spalling. The third and final inspection will be at the completion of steel surface preparation prior to the installation of repair mortar. The repair location and extent will be documented by photograph, given distinct repair identifier, and wi.l be annotated on a simplified diagram of the balcony (threshold; beam, or column). The inspection records will be forwarded to the building department upon completion of the project. Note that sliding glass doors and thres It was included diri the, contract for the ;-`but hasaiot been validated. 'Ipossible necess'afy to accorripltsa this, will be Sinc - ger filer ofeional Enginerr; orid' 855' Atlantic View Beach Club Engineer of Record Letter work has been identified as part of the scope of work. )se of completion. The necessity for threshold work is cold and sliding glass door work, and the steps 3sed if and when required. Page 1 of 1 Joe Cicio From: Joe Cicio Sent: Tuesday, July 13, 2010 9:51 AM To: 'John Breitenbach' Subject: RE: 7-13-10 from Breitenbach Engineering Thanks John for the response * Would you please remove "Sustainable Earth Engineering " from your letter and use the name Roger Baber as the company name does no, carry a certificate of authorization from FBPE. Thanks From: John Breitenbach [mailto:jbach442@com Sent: Tuesday, July 13, 2010 9:44 AM To: Joe Cicio Cc: sustainableearth@comcast.net Subject: 7-13-10 from Breitenbach Engineering Re: Atlantic View BCC St Lucie Bldg Dept: Permit App.# 1006-01 Attached is the letter of intent in pdf format, sig sealed is in regular mail. John D. Breitenbach, PE Breitenbach Engineering, Inc 9073 SE Bridge Rd, Suite A Hobe Sound, Florida 33455 772-546-6809 Tel/Fax ibach442(a�comcast. net Please Note: Florida has very broad public records laws. Most w available to the public and media upon request. It is the policy of or copying. Your e-mail communications will be subject to public please notify the sender by reply e-mail and delete all materials f and sealed, for the Threshold Inspections. A hard copy, signed and n communications to or from County officials regarding County business are public records Lucie County that all County records shall be open for personal inspection, examination and / :losure unless an exemption applies to the communication. If you received this email in error, all computers. 1