0503-0349 LETTER-ENGINEERING REPORT
Roof Asset �ECEYVED Management, Inc. Post Office Box 7236 JUL 1 9 Lakeland, FL 33807-7236 (863) 701-2742/FAX(863) 701-2403 Bar. Florida Architecture Cert.of Auth.AA26000505 July 12, 2006 SCANNED BY Mr. Terry McMillan StLucie C'niinfi TOMAC of Florida, Inc. 3503 Ocean Drive Vero Beach, FL 32963 RE: Atlantic View Condominium closeout documents Dear Terry: POSTfO We are in receipt of the engineering report (attached) from Exterior Research & Design, L.L.C. for the above referenced project. This report properly documents the design pressures required for the roof system to meet the Florida Building Code and includes a copy of the Miami Dade approval for the Soprema system that was used substantiating that the roof system has been tested to meet the requisite design pressures. If you need any additional information please notify my office. Please give me a call with any questions. Thomas A. Feazel Vice President TAF/sdw RECEIVED JUL 14 2006 Exterior Research & Design, L.L.C. Building Science and Envelope Consultants ERD Certificate of Authorization #9503 February 21, 2005 Paul Riesebieter Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281 RE: Atlantic View Condominiums — Ft, Pierce, FL Design Pressure Calculations & System Attachment Analysis ERD Project #2500-AVC-FPF Dear Paul: We are in receipt of documents from your office, received on January 14, 2005, outlining the design parameters for the above noted project and have spoken with Chris Long of TRA on today's date. This letter serves to document wind design pressures for roof cladding at the upper roof only in accordance with ASCE 7-98' based on the building parameters provided, and establish attachment requirements for the proposed Soprema roof assembly to meet said pressures. Note: The Project Information Form indicates the project is not eligible for a wind warranty rider. 1. DESIGN PRESSURES: The following parameters are set forth in the referenced documents. Design Parameter Value Source Max. Roof Height: 181 ft From PIF Parapet Height: > 3 ft From PIF Building Exposure: C From PIF Category: II Assumed Importance Factor: 1.0 Assumed Wind Speed: 140 mph From ASCE 7-98 map Designing for: Roof Cladding Tributary Area: < 10 ft2 Area per fastener Int. Pressure Coeff: 0.18 Assumed Assumotions: a. Non -Critical structure, Category II Building -�- I = 1.00 b. Enclosed Building b GCp, = +0.18 c. The building is not located atop any significant hill, ridge or escarpment (Kzt = 1) d. No load combinations apply (Kd = 1.0) e. There are no overhangs. f. The building is not designated as an EHPA. Main Office: 2412 7t6 Ave W • Suite 101 • Seattle, WA 98119 . Voice (206) 467-0054 • Fax (206) 467-5840 Laboratory: 600 W. Nickerson St • Seattle, WA 98119 • Voice (206) 298-3620 • Fax (206) 298-3130 ERD East: 2 Mattoon Road • Waterbury, CT 06708 9 Voice (203) 596-7884 9 Fax (203) 596-7058 e ` Certificate of Authorization *13503 Res I s• )I Riesebieter, Soprema, Inc. Re: Atlantic View Condominiums February 21, 2005 Page 2 of 3 Table 1: Design Pressures, ASCE 7-98 Pressure Zone Design Pressures (psf) - Roof Cladding Upper Roof Zone 1 (field): -113.4 Zone 2 (perimeters): -177.9 Zone 3 (corners): See Zone 2* Zone 2/3 Dimension: Min. 10.5 ft Notes: 1. Perimeter and corner pressure zones are those within the lesser of 40% of the height or 10% of the minimum building width, but not less than 3 feet, and not less the Soprema requirements. 2. *It is reported that a parapet wall > 3 ft exists on the upper roof. ASCE 7-98 specifies treatment of Zone 3 as Zone 2 if such a wall exists. If no such wall exists, reevaluation is required. 2. PROPOSED ROOF SYSTEM: It is understood the following assembly is under consideration: • Roof Deck: Existing lightweight insulating concrete cast over existing concrete deck • Base Membrane: Soprafix[F] mechanically attached with Tri-Fix Fasteners • Cap Membrane: Sopralene Flam 180 FR GR, heat welded. 3.- PERFORMANCE DATA: LABORATORY TESTING: The proposed roof system has been tested for wind uplift resistance in accordance with FM Standard 4470 / TAS 114(]). Review of data yields a base membrane attachment value of 214 Ibf per fastener. Applying a 2 to 1 margin of safety provides a laboratory design value of 107 Ibf per fastener. FIELD TESTING: Protech Products field report dated 01/01/05 documents withdrawal resistance testing of the Tri-Fix Fasteners installed in the existing roof deck at the upper roof. Statistical analysis of the data in accordance with TAS 105 yields a Minimum Characteristic Resistance Force (MCRF) of 182 lbf. The existing deck at the upper roof is suitable to receive the Tri-Fix Fasteners while maintaining the above noted design value (107 Ibf). 4. ATTACHMENT REQUIREMENTS': Table 2 provides minimum base membrane attachment requirements to meet the design pressures in Table 1. Attachment is based on a design value of 107 Ibf per fastener. I Determined in accordance with procedures published in FBC PAS 117. Main Office: 2412 7" Ave W • Suite 101 • Seattle, WA 98119 • Voice (206) 467-00S4 • Fax (206) 467-5840 ERD East: 2 Mattoon Road • Waterbury, CT 06708 • Voice (203) 596-7884 • Fax (203) 596-7058 Laboratory: 600 W. Nickerson St • Seattle, WA 98119 . Voice (206) 298-3620 9 Fax (206) 298-3130 E-RD. Certificate of Authorization #9503 11 Riesebieter, Soprema, Inc. Re: Atlantic View Condominiums February 21, 2005 Page 3 of 3 Table 2: Attachment Requirements Soprafix[F] with Tri-Fix Fasteners Pressure Zone: Attachment - Upper Roof Zone 1 (Field): Max. 8-inch o.c. in a 5-inch lap and 8-inch o.c. in one center row Zone 2 (Perimeters): Max. 7-inch o.c. in a 5-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows Zone 3 (Corners): I See Zone 2* -it is reported that a parapet wan > 3 rt exists on the upper roor. ASCt i-.vts specines rrearmenr or zone 3 as Zone 2 if such a wall exists. If no such wall exists, reevaluation is required S. COMMENTS: A. The information herein relates solely to the upper roof at the project. ERD's scope excludes any work at the lower roof. B. The analysis herein relates solely the new roof cladding to be installed atop the existing roof deck. ERD does not purport to address wind loading or adequacy of the existing LWIC or structural concrete roof decks, perimeter edge terminations, flashings or rooftop equipment. C. Tri-Fix Fasteners shall be installed in strict accordance with published installation instructions, using the correct angle of installation for each of the three nails. D. The laps in the Soprafix[F] base membrane, as well as the cover -strips in center rows, shall be heat -welded in accordance with Soprema installation instructions, fully encapsulating the fasteners within the lap or beneath the cover strip. 6. CONCLUSIONS: The proposed roof system outlined in Section 2, when attached in accordance with Section 4, meets the wind load requirements of FBC Chapter 16 / ASCE 7-98, provided the applicable comments in Section 5 are fulfilled. Please contact our office with any questions. Sincerely, Robert Nieminen, P.E. Florida Reg. No. 59166 General Manager, ERD East c.c. . Chris Long, The Roof Authority - Todd Rauktis, Roofing Technologies, Inc. ASCE 7-98, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers, ©2000 Main Office: 2412 7t6 Ave W • Suite 101 . Seattle, WA 98119 • Voice (206) 467-0054 • Fax (206) 467-5840 ERD East: 2 Mattoon Road • Waterbury, CT 06708 • Voice (203) 596-7884 • Fax (203) 596-7058 Laboratory: 600 W. Nickerson St • Seattle, WA 98119 9 Voice (206) 298-3620 • Fax (206) 298-3130 MIAMI-D BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281 MUM -DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2008 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed. by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).. This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County); reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Soprema Modified Bitumen Roofing Systems Over Lightweight Insulating Concrete Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA # 04-0927.06 and consists of pages 1 through 46. The submitted documentation was reviewed by J ge L. Acebo. �- NOA No.: 06-0216.01 Expiration Date: 02/22/11 Approval Date: 03/09/06 Page 1 of 46 I � F Deck Type 4: Lightweight Concrete Deck Description: Cellular Concrete, LLC. Lightweight Insulating Concrete, 300 psi. min System Type E(2): Base sheet mechanically fastened All General and System Limitations apply. Deck: Minimum 22 ga., type BV steel decking attached to support spaced at 5' o.c. maximum using 3/8" puddle welds with washer (every bottom flute). Steel deck side laps are attached three Traxx 1 #10 evenly spaced between supports or structural concrete deck. Base Sheet: One ply of Soprafix, Soprafix-e, Soprafix [S], Soprafix [F], Soprafix [X] or Soprafix [H] fastened to the deck as described below: Note: Soprafix [IV is for use with a self -adhered cap membrane. Fastening #1: Attach base sheet using Tri-Fixx Fasteners spaced 9" o.c. in a 5" lap. The side lap fastener row is encapsulated in the heat welded lap. (meets —45 psf — See General Limitation #7.) Fastening #2: Attach base sheet using Tri-Fixx Fasteners spaced 8" o.c. in a 5" lap and 8" o.c. in one center rows. The side lap fastener row is encapsulated in the heat welded lap and the center row is stripped -in with a 8" wide strip of torch applied membrane. (meets —75psf— See General Limitation #7.) Ply Sheet: (Optional) One ply of Elastophene Flam, Elastophene Flam 2.2, Sopralene (180, 250 or 350) Flam, or Sopralene (180, 250 or 350) SP heat welded. Membrane: Elastophene Flam, Elastophene SP 2.2mm, Elastophene SP 3.0mm, Elastophene Flam GR, Elastophene Flam FR GR, FR+GR, Sopralene (1.80, 250, 350) Flam GR, Sopralene (180, 250, 350) Flam FR GR, FR+GR, or Sopralast 50 TV Alu heat welded or Colphene FR GR or Colphene HR FR GR self adhered. NOA No.: 06-0216.01 a Expiration Date: 02/22/11 Approval Date: 03/09/06 Page 22 of 46