Loading...
HomeMy WebLinkAbout99110499 POOL - SPA PLAN■ SHOWER AND HOSE BIBS W/ VACUUM BREAKER WITHIN 20 FT OF POOL AND SPA WATERS EDGE SKIMMER W/SPRING LOADED CHECK VALVE AND EQUALIZER LINE PAVER DECK W/NON-SLIP IMPERVIOS FINISH, SLOPE AWAY FROM SPA AT 2% TO 4% GRADE. (2) 12" x 12" MAIN DRAIN W/ TAMPER PROOF SCREW FASTENED FRAME AND ANTI VORTE> COVER VELOCITY THRU GRATE= 0.413 FPS. NOTE=PROVIDE AT LEAST I FEET VERTICAL CLEARANCE ABOVE SPA WATER AND DECK SURFACES SLOPE DECK 2% TO 4% 3/4"(ON TREAD) x 2"(ON RISER) - BULLNOSE TILE(DARK) CONTINOUS ON ALL STEP EDGES AND BENCH EDGES DISTANCE FROM BOTTOM OF SPA TO SKIMMER MIDPOINT 3'6" DISTANCE FROM TOP OF SPA DECK TO SKIMMER MIDPOINT 6" TOTAL STEP RISER DISTANCE 4' USE (4) 12" STEPS 12 VOLT 100 WA SPA LIGHT HAND RAIL HANDRAIL r TOP STEP SHALL HAVE A 'CLEAR MINIMUM SURFACE AREA OF 10" WIDE x 12" LONG RETURN INLETS JETS (TOTAL OF 8) LENGTH OF TOP STEP EDGE 6' -THERAPY JETS TOTAL 10 PLANTER v SKIMMER JUNCTION BOX I I . ff W/SPRING LOADED AND XFMR \�l�`\ CHECK VALVE AND \\ EQUALIZER LINE \\\\ Iliz" STATIC LINE \ 21j2" RETURN LINE \\ CX" MAIN DRAIN LINE \ 2�'2" SKIMMER LINE \\\ \ 3" JET LINE PLAN OF SPA SCALE: 1/8" = I'-0" 14' rc"x6" GLAZED TILE TYP. 2" MAX. OVERHANG WATER LEVEL EXPOSED AGGREGATE — FINISH (2) 12" x 12" M.D. VELOCITY THRU GRATE — SHALL NOT EXCEED i S F.P.S. GRATE SHALL BE SECURED WITH SCREWS MAIN DRAIN SHALL BE FITTED WITH HYDROSTATIC RELIEF VALVE 40 I F— SLOPE TO DRAIN (TYP.) BULLNOSE BRICK SLOPE DECK 2% TO 49. i 2 • 3 CONT. THESE 1:'UV,1: 3 ) 9%, L PROPOSED WO ,.', ARE SK:.'_ 's`', : ANY ^ORRECTIONS REQU4' tvZj -d " `'?:"4., I1,[ aPECTORS THAT MAY LSE NE,, ° ,'V ORDER TO COMPLY VI? CODES. l 5PA DATA UNIT SERVED SEE APPLICATIONS SIZE 14' x 14' AREA 154 S.F. DEPTH V6" VOLUME 3280 GALLON PERIMETER 44 LF, TURNOVER 30 MIN. FLOW RATE 110 G.P.M. BATHING LOAD 15 PROVISOS 1. Provide an equalizer valve that fits the Bermuda skimmer. 2. Provide an erosion feeder capable of feeding 6 ppm into 110 GPM recirculation flow rate. 3. Specify the radius of curve for the edge of the stairs. Identify the center of curve. 4. Contractor shall note discrepancy in sizing of the main drain line between the piping plan on Sheet 1 (4" diameter) and the piping schematic on Sheet 4 (6" diameter). The 4" diameter line causes flow velocity to exceed 3 fps, and is thus not acceptable. 6" THICK WALLS 4 FLOOR W/03 v12" OCR Rp;,;Or HEALTH o/c EACH WAY. Rr- �CE-A,AED OU 1 9 1999 BUREAU OF FACILITY PROORAMI SPA cfk6d %ECTION SCALE: N.T.S M TL�UU! ,IrK1!4 NAt STATE O'� Li.'r"oDA Dept Qt "-ealth Sp 15 8 2 5 NOV I Environmental Enni,. wing I I STIW'L RL DESIGN NC. "'ED SCANNLU BY St LudeGmmtt a A r s m r°,, r A >A ANGULAR -- DRINKING FOUNTAIN to W/H.B. MAX20' NON-ABSORBANT,,� SLIP RESISTANT PAVER DECK SLOPED MIN2%, MAX 4% AWAY FROM POOL EQUIPMENT LOCATION COLLECTOR TANK FOR SPA RESTROOM NOTES: I. TIOLETS AND SHOWER FLOORS SHALL BE CONSTRUCTED OF CONCRETE OR OTHER IMPERVIOUS MATERIAL HAVING A SMOOTH SLIP RESISTANT FINISH. 2. FLOOR SHALL SLOPE TO FLOOR DRAINS WITH WALL -FLOOR INTERSECTIONS COVED FOR CLEANING. 3. CARPET, DUCKBOARDS, OR OTHER SIMILAR FLOOR COVERINGS ARE PROHIBITED. 4. INTERIOR PARTITIONS SHALL BE PLACED ON A CONTINUOUS 4" HIGH CONCRETE BASE. 5, ENTRANCE DOORS SHALL BE LABELED TO DEPICT EACH SEX. (o. SANITARY FACILITIES ARE TO BE MAINTAINED IN A CLEAN SANITARY MANNER AND BE SUPPLIED WITH SOAP, PAPER TOWELS, TOILET PAPER, AND OTHER ITEMS ASSOCIATED WITH SANITARY FACILITIES. 7, EACH RESTROOM SHALL HAVE A HOSE BIBB, WITH A VACUUM BREAKER. S. SIGNS SHALL BE POSTED IN MINIMUM I" HIGH LETTERS LEGIBLE FROM ALL PORTIONS OF THE POOL DECK SHOWING DIRECTION TO SANITARY FACILITIES. 9. ALL FENCING AROUND POOL FACILITY SHALL MEET LOCAL CODE REQUIREMENTS. IA, WALKWAYS BETWEEN THE POOL AND SANITARY FACILITIES SHALL BE CONCRETE WITH A NON -SLIP FINISH. II. THERE SHALL BE NO FOOD OR DRINK SERVING FACILITIES WITH 12 FEET OF THE INNER EDGE OF THE POOL DECK NOTE:MIN. 15' OF WALKWAY BETWEEN SPA AND SANITARY FACILITIIES SHALL BE IMPERVIOUS AND SLIP RESISTANT. :WALL FLOOR INTERSECTION OF SANITARY FACILITIES SHALL BE COVED. SANITARY FACILITIES FLOOR SHALL BE SLIP RESISTANT AND IMPERVIOUS. elTE PLAN mm NOTE: A POOL CLOSED SIGN MUST BE CONSPICUSLY PLACED NEAR THE ENTRANCE OF EACH BATHING UNIT THIS SIGN SHALL BE PLACED EACH DAY NO LATER THAN ONE HALF HOUR BEFORE SUNSET AND SHALL NOT BE REMOVED EARLIER THAN ONE HALF HOUR AFTER SUNRISE THE LETTERING MUST BE MINIMUM OF FOUR INCHES C4") HI6fl4,WITI4 CONTRASTING BACK GROUND COLOR OF THE SIGN STATING "POOL CLOSED" • • — SANITARY FACILITIES A SIGN SHALL BE POSTED SHOWING DIRECTIONS I WATER CLOSET ILAVATORY 2 URINALS IV "I it • 5 WATER CLOSETS ILAVATORY rI w s • • • y` + • GENERAL NOTES: • THE SPA SHALL BEAR ONLY ON CLEAN SANDS. ALL ORGANIC OR MARL ENCOUNTERED ON EXCAVATION SHALL BE REMOVED IN THEIR ENTIRETY AND BACKFILLED WITH SAND. 1500 PSF BEARING CAPACITY IS REQUIRED. • OWNER AND CONTRACTOR SHALL VERIFY SPA LAYOUT AND ALL DIMENSIONS, NOTIFY ENGINEER OF ANY CHANGES AND OBTAIN REVISED PLANS FOR CHANGES. • ALL HOSE BIBBS SHALL HAVE VACUUM BREAKERS. • NO OVERHEAD WIRING WITHIN 10' OF SPA. • ELECTRICAL EQUPMENT WIRING AND INSULATION SHALL CONFORM WITH CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE OF THE NATIONAL FIRE PROTECTION ASSOCIATION AND SHALL COMPLY WITH APPLICABLE LOCAL CODES. • ALL PIPING TO BE P.V.C. SCHEDULE 40 NON -THREADED NSF-PW APPROVED. • ALL VALVES SHALL BE TAGGED AND WATERPROOF OPERATING INSTRUCTIONS POSTED IN FILTER ROOM. • DECK AREA OF SPA AS REQUIRED TO BE SLIP RESISTANT AND NON PERVIOUS • SPA SHELL SHALL BE LIGHT (PASTEL) IN COLOR SO AS TO REFLECT RATHER THAN ASSORT LIGHT. • STEPS TREADS SHALL HAVE SLIP RESISTANT FINISH, MIN. WIDTH 10" EDGES SHALL HAVE CONTRASTING COLORED STRIPS 2" IN WIDTH. • STEPS RISERS EDGES SHALL HAVE CONTRASTING COLORED STRIPS 2" IN WIDTH, HEIGHT SHALL NOT EXCEED 12" EXPECT BOTTOM WHICH IS ALSO THE BECNH. • ALL CONSTRUCTION SHALL COMPLY WITH CHAPTER 64E-9 OF THE STATE OF FLORIDA DEPARTMENT OF HEALTH, FLORIDA ADMINISTRATIVE CODE AND LOCAL BUILDING CODE. • PROVISION SHALL BE MADE FOR VENTILATED STORAGE OF CHEMICALS UNDER ROOF AND PROTECTION FROM ACCESS BY UNAUTHORIZED PERSONS SPA RULES AND REGULATIONS RULES AND REGULATIONS FOR BATHERS SHALL BE POSED NEAR SPA SIDE, BE LEGIBLE FROM SPA DECK, LETTERING SHALL BE A MIN. ONE(I) INCH IN HEIGHT, EXCEPT "NO DIVING ALLOWED" TO BE A MIN. FOUR(4) INCH IN HEIGHT AND SHALL CONTAIN THE FOLLOWING: I. NO ANIMALS IN SPA OR ON SPA DECK 2, NO FOOD, DRINK OR GLASS IN SPA OR ON DECK AREA. 3. SHOWER BEFORE ENTERING SPA. 4. BATHING LOAD 15 PERSONS. 5, SPA HOURS:DAWN TO DUSK 6. WATER TEMPERATURE NOT TO EXCEED 104' F -1. NO DIVING ALLOWED. 8. CHILDREN UNDER 12 MUST HAVE ADULT SUPERVISION S. PREGNANT WOMEN, SMALL CHILDREN, PEOPLE WITH HEALTH PROBLEMS AND PEOPLE USING ALCOHOLNARCOTICS OR OTHER DRUGS THAT CAUSE DROWSINESS SHOULD NOT USE SPA POOLS WITHOUT FIRST CONSULTING A DOCTOR 10. MAXIMUM USE 15 MINUTES FIRST AID EQUIPMENT FIRST AID EQUIPMENT SHALL BE AVAILABLE FOR USE IN CONNECTION WITH INJURIES WHICH MAY OCCUR IN THE SPA OR ON DECK. 1 1/2" ANCHOR UJ Dr-::PA1NC�40R [DETAIL u.T.s. 12 VOLT TRANSFORMER OR GP.I. (100 WATT) TO EXISTING PANEL 3012 IN 1/2" COND. NOTE:ALL ELECTRICAL W.P. PANEL SHALL CONFORM W/ ART. 680 N.E.0 IN POOL AREA GROUND ALL BOXES, RAILS, LIGHT, MOTOR, ECT. W/ 08 WIRE ELECTRICAL DIAGRAM NOTE: MATERIALS USE IN HEATER MUST BE NON -TOXIC t ACCEPTABLE FOR POTABLE WATER USE. 2 100 WATT(UNDER WATER) LIGHT W/LOW WATER CUT OFF DEVICE MIN. 18" BELOW WATER LINE THERAPY JET PUMP 3 H.P. RECIRCULATION PUMP 3 H.P. X IIIIII-111111=IIIIII 111111=111111= Pyle 2 SECURED GRATE Sr<IMME R D TAi N.S.F. APPROVED) N.T.s. (2) 03 —LF SKIMMER 1 WITH WALL �f�f1 1�f R DETAIL Rm N Im IVA (N.S.F. AFFFOVED) N.T.s. - Y • - xo • • w - - 14 • • NOTES: 5 FLOOR SHALL BE NON ABSORBANT, SLIP IOESISTANT a SLOPED FOR DRAINAGE r ALL EQUIPMENT IS ACCEPTABLE AND DESIGNED FOR OUT DOOR USE. ALL PIPING SHALL BE PAINTED TO PROTECT IT FROM U.V. RAYS. • EQUIPMENT AREA SHALL BE ENCLOSED BY 5' CHAIN LINK FENCE W/3' SELF CLOSING AND SELF LATCHING GATE. r MATERIAL USED FOR HEATER SHALL BE NON -TOXIC AND ACCEPTABLE FOR POTABLE WATER USE. • 30 FOOT CANDLES OF LIGHTING SHALL BE PROVIDED AT EQUIPMENT LOCATION AUTOMATIC AND MANUAL FILL W/ 2" AIR GAP AND HOSE BIBS 4 VAC. BREAKER a n F W o THERMOMETER z_1 W Q 9 EROSION FEEDER 0_ WITH SOLENOID VALVE n FROM HEATER TO HEATER CF-30250P FLOW METER (60-240 GPM) 2112" F_ L PRESSURE GAUGES.. 2" DIAM. FACE, 0-60 P51 AIR REL VALVE (TYP) CAT 2000 PLUS CONTROLLER Q Q N COLLECTOR TANK Z - �300 GALLONS TOTAL CAPACITY ffim- D.E. FILTER EQUIFMENT RFLAN LAN VIEW N.T.S. LINE 3 H.P. SELF PRIMING THERAPY PUMP W/ HAIR 4 LINT STRAINER 2" WASTE LINE W/ F AIR GAP 2112 � TO STORM SEWER EQ(I/PMENT SCHEDULE SOURCE OF WATER. PRIVATE POTABLE WATER SUPPLY 3 H.P. SELF PRIMING RECIRCULATION PUMP W/ HAIR 4 LINT STRAINER SEPARATION —TANK SIGHT GLASS VALVE SEQUENCE CHART MATERIALS IN THE HEATER ARE NON TOXIC AND ACCEPTABLE FOR POTABLE WATER USE ro CF-30250P FLOW FLOW METER (60 m 2 1/2" PRESSURE GAUGE ( 0 - 60 PSI ) ( TYP ) AIR RELIEF VALVE S (TYP) VALVE OPERATION 1 2 �3 4 5 6 NORMAL OCCCOC BACKWASH C O O C C C PRECOAT 12CCCCO C C O C C START UP O 11 NOTE: CHEMICALS SHALL BE STORED IN A COOL DRY AND WELL VENTILATED AREA UNDER A ROOF AND THE AREA SHALL BE INACCESIBLE TO THE PUBLIC. CHEMICALS WHICH EMIT CORROSIVE FUMES SHALL NOT BE STORED IN THE EQUIPMENT ROOM CAT 2000 PLUS CONTROLLER NOTE: AIR GAP LEVEL Up � NOTE: FEEDER SHALL W/SPA WATER LEVEL iS'OI-A16 .14A- Imes HAVE RATE OF FLOW AUTOMATIC AND MANUAL INDICATOR AND FLOW FILL W/ 2" AIR GAP AND EROSION FEEDER CONTROL VALVE. HOSE BIBS 4 VAC. BREAKER WITH SOLENOID VALVEpP-P 141 THERMOMETER 3 H.P. SELF PRIMING � RECIRCULATION PUMP W/ HAIR 4 LINT STRAINER L IN 2112" TO WASTE SIGHT GLASS 3 ti WASTE LINE TO STORM SEWER FILTER TANK DRAIN LINE W/ P AIR GAP �-DE. FILTER AIR RELIEF VALVE (TYP) C=CLOSE PIPING SCHEMATIC O=OPEN OTE: MULTI PORT VALVES MAY BE USED OVIDED IT ALLOWS FOR SAME VALVIN N.T.S. OPERATION AS SHOWN IT. ITEM MANUFACTURER MODEL NO: DESCRIPTION MAIN DRAIN, FRAME 4 GRATE HAYWARD SP-1032 12" x 12" 3 H.P. THERAPY PUMP W/HAIR 4 LINT STRAINER PUREX-TRITON WF-12 SELF PRIMING (150 GPM • 00 TDA4) "4R 3 H.P. RECIRC. PUMP W/HAIR 4 LINT STRAINER PUREX-TRITON WF-12 SELF PRIMING (110 GPM • 10 TDH) 60 S.F. DE. FILTER PURER -TRITON FNS-60 NSF. APPROVED 2.5" FLOWMETER (60 TO 240 GPM) BLUE WHITE CF-302501= EROSION FEEDER PPD^ D ADJUSTME NT VALVE W / RATE OF FLOW NSF APPROVED AUTO SURFACE SKIMMER EAU AL. r- 50-6310 NSF APPROVED TEST KIT TAYLOR 2005 THERMOMETER LETRO SL-IDW 2" PRESSURE GAUGE ASHCROFT GPD-26 0-60 PSI STATIC FITTING PURER TRITON 46114100 COLLECTOR TANK COM-PAC F-300 300 GALLON TANK LIGHT NICHE STA-RITE 5161-235-1 LIGHT 12VI00 W/LOW WATER CUT OFF STA-RITE 5501-2206 50' CORD 10 THERAPY JETS-GUNITE MICRO'SSAGE HYDRO AIR 16-5215 I S.S. HANDRAIL S.R. SMITH HR-12 I HEATER LAARS 400,000 BTU PROPONE HEATER DE. SEPARETION TANK PAC-FAB PF-1050 RATED FOR 60 SP. I CAT 2000 PLUS CONT.W/FLOW CELL KIT CAT 2000 PLUS W/AC075 CHL 4 PH 8 RETURN INLETS HAYWARD SP-1022 4 SD1419D HYDRAULIC DATA PIPE FLOW RATE VELOCITY 21j2" RETURN INLETS 110 G.P.M. 1.4 F.P.S 6" MAIN DRAIN 260 G.P.M. 2.9 F.P.S. 2112" SKIMMER 66 G.P.M. 43 F.P.S. 3" THERAPY JETS 150 G.P.M, roB F.PS. RETURN INLETS 110 G.P1'9 / 8 INLETS 13.15 GALLONS/INLET u 3 3 H.P. SELF PRIMING THERAPY PUMP W/ HAIR 4 LINT STRAINER VALVE LEGEND GATE VALVE PROPORTIONAL FLOW VALVE G v P� 5� � 300 GALLON COLLECTOR TANK W/ LOCKABLE LID. SCNNIVtU St Luc a County w CASTLE PINES @ PGA VILLAGE DATE: Ike i" t 1/26/99 DAVlc 1. FaS.� I.ari, ,-F. H.CENO: L'CENSE 0.41646 99988-I1S 5155 Powerl1r"e Road Fort Lauderdale, Florida 3330E INC. SHEET 4OF4 t r • r • • s.: • • • • • • • • a • i