HomeMy WebLinkAbout99110499 POOL - SPA PLAN■
SHOWER AND HOSE BIBS W/
VACUUM BREAKER WITHIN 20 FT
OF POOL AND SPA WATERS EDGE
SKIMMER
W/SPRING LOADED
CHECK VALVE AND
EQUALIZER LINE
PAVER DECK W/NON-SLIP
IMPERVIOS FINISH, SLOPE
AWAY FROM SPA AT 2%
TO 4% GRADE.
(2) 12" x 12" MAIN DRAIN W/ TAMPER PROOF
SCREW FASTENED FRAME AND ANTI VORTE>
COVER VELOCITY THRU GRATE= 0.413 FPS.
NOTE=PROVIDE AT LEAST I FEET
VERTICAL CLEARANCE ABOVE
SPA WATER AND DECK SURFACES
SLOPE DECK 2% TO 4%
3/4"(ON TREAD) x 2"(ON RISER) -
BULLNOSE TILE(DARK)
CONTINOUS ON ALL STEP EDGES
AND BENCH EDGES
DISTANCE FROM BOTTOM OF SPA TO SKIMMER
MIDPOINT 3'6" DISTANCE FROM TOP OF SPA
DECK TO SKIMMER MIDPOINT 6"
TOTAL STEP RISER DISTANCE 4'
USE (4) 12" STEPS
12 VOLT 100 WA
SPA LIGHT
HAND RAIL
HANDRAIL
r
TOP STEP SHALL HAVE A
'CLEAR MINIMUM SURFACE
AREA OF 10" WIDE x 12" LONG
RETURN INLETS
JETS (TOTAL OF 8)
LENGTH OF TOP STEP EDGE 6'
-THERAPY JETS
TOTAL 10
PLANTER
v SKIMMER
JUNCTION BOX I I . ff W/SPRING LOADED
AND XFMR \�l�`\ CHECK VALVE AND
\\ EQUALIZER LINE
\\\\
Iliz" STATIC LINE \
21j2" RETURN LINE \\
CX" MAIN DRAIN LINE \
2�'2" SKIMMER LINE \\\ \
3" JET LINE
PLAN OF SPA
SCALE: 1/8" = I'-0"
14'
rc"x6" GLAZED TILE TYP. 2" MAX. OVERHANG
WATER LEVEL
EXPOSED AGGREGATE —
FINISH
(2) 12" x 12" M.D. VELOCITY THRU GRATE —
SHALL NOT EXCEED i S F.P.S.
GRATE SHALL BE SECURED WITH SCREWS
MAIN DRAIN SHALL BE FITTED WITH
HYDROSTATIC RELIEF VALVE
40
I F—
SLOPE TO
DRAIN (TYP.)
BULLNOSE BRICK
SLOPE DECK 2% TO 49.
i
2 • 3 CONT.
THESE 1:'UV,1: 3 ) 9%, L PROPOSED WO ,.',
ARE SK:.'_ 's`', : ANY ^ORRECTIONS
REQU4' tvZj -d " `'?:"4., I1,[ aPECTORS THAT
MAY LSE NE,, ° ,'V ORDER TO
COMPLY VI? CODES.
l
5PA DATA
UNIT SERVED
SEE APPLICATIONS
SIZE
14' x 14'
AREA
154 S.F.
DEPTH
V6"
VOLUME
3280 GALLON
PERIMETER
44 LF,
TURNOVER
30 MIN.
FLOW RATE
110 G.P.M.
BATHING LOAD
15
PROVISOS
1. Provide an equalizer valve that fits the Bermuda skimmer.
2. Provide an erosion feeder capable of feeding 6 ppm into 110 GPM recirculation flow rate.
3. Specify the radius of curve for the edge of the stairs. Identify the center of curve.
4. Contractor shall note discrepancy in sizing of the main drain line between the piping plan
on Sheet 1 (4" diameter) and the piping schematic on Sheet 4 (6" diameter). The
4" diameter line causes flow velocity to exceed 3 fps, and is thus not acceptable.
6" THICK WALLS 4
FLOOR W/03 v12" OCR Rp;,;Or HEALTH
o/c EACH WAY.
Rr-
�CE-A,AED
OU 1 9 1999
BUREAU OF FACILITY PROORAMI
SPA cfk6d %ECTION
SCALE: N.T.S
M
TL�UU! ,IrK1!4 NAt
STATE O'� Li.'r"oDA
Dept Qt "-ealth
Sp 15 8 2 5 NOV
I Environmental Enni,. wing
I I STIW'L RL DESIGN NC. "'ED
SCANNLU
BY
St LudeGmmtt
a
A
r
s
m
r°,,
r
A
>A
ANGULAR --
DRINKING FOUNTAIN
to
W/H.B. MAX20'
NON-ABSORBANT,,�
SLIP RESISTANT PAVER
DECK SLOPED MIN2%,
MAX 4% AWAY FROM POOL
EQUIPMENT LOCATION
COLLECTOR TANK
FOR SPA
RESTROOM NOTES:
I. TIOLETS AND SHOWER FLOORS SHALL BE CONSTRUCTED OF CONCRETE OR OTHER
IMPERVIOUS MATERIAL HAVING A SMOOTH SLIP RESISTANT FINISH.
2. FLOOR SHALL SLOPE TO FLOOR DRAINS WITH WALL -FLOOR INTERSECTIONS
COVED FOR CLEANING.
3. CARPET, DUCKBOARDS, OR OTHER SIMILAR FLOOR COVERINGS ARE PROHIBITED.
4. INTERIOR PARTITIONS SHALL BE PLACED ON A CONTINUOUS 4" HIGH CONCRETE BASE.
5, ENTRANCE DOORS SHALL BE LABELED TO DEPICT EACH SEX.
(o. SANITARY FACILITIES ARE TO BE MAINTAINED IN A CLEAN SANITARY MANNER AND BE
SUPPLIED WITH SOAP, PAPER TOWELS, TOILET PAPER, AND OTHER ITEMS ASSOCIATED
WITH SANITARY FACILITIES.
7, EACH RESTROOM SHALL HAVE A HOSE BIBB, WITH A VACUUM BREAKER.
S. SIGNS SHALL BE POSTED IN MINIMUM I" HIGH LETTERS LEGIBLE FROM ALL PORTIONS
OF THE POOL DECK SHOWING DIRECTION TO SANITARY FACILITIES.
9. ALL FENCING AROUND POOL FACILITY SHALL MEET LOCAL CODE REQUIREMENTS.
IA, WALKWAYS BETWEEN THE POOL AND SANITARY FACILITIES SHALL BE CONCRETE WITH
A NON -SLIP FINISH.
II. THERE SHALL BE NO FOOD OR DRINK SERVING FACILITIES WITH 12 FEET OF THE
INNER EDGE OF THE POOL DECK
NOTE:MIN. 15' OF WALKWAY BETWEEN SPA AND
SANITARY FACILITIIES SHALL BE IMPERVIOUS
AND SLIP RESISTANT.
:WALL FLOOR INTERSECTION OF SANITARY FACILITIES
SHALL BE COVED. SANITARY FACILITIES FLOOR SHALL
BE SLIP RESISTANT AND IMPERVIOUS.
elTE PLAN
mm
NOTE: A POOL CLOSED SIGN MUST BE CONSPICUSLY PLACED NEAR THE
ENTRANCE OF EACH BATHING UNIT THIS SIGN SHALL BE PLACED EACH DAY
NO LATER THAN ONE HALF HOUR BEFORE SUNSET AND SHALL NOT BE
REMOVED EARLIER THAN ONE HALF HOUR AFTER SUNRISE THE LETTERING
MUST BE MINIMUM OF FOUR INCHES C4") HI6fl4,WITI4 CONTRASTING BACK GROUND
COLOR OF THE SIGN STATING "POOL CLOSED"
•
•
— SANITARY
FACILITIES A SIGN
SHALL BE POSTED
SHOWING DIRECTIONS
I WATER CLOSET
ILAVATORY
2 URINALS
IV
"I
it
•
5 WATER CLOSETS
ILAVATORY
rI
w
s
•
•
•
y`
+
•
GENERAL NOTES:
• THE SPA SHALL BEAR ONLY ON CLEAN SANDS. ALL ORGANIC OR
MARL ENCOUNTERED ON EXCAVATION SHALL BE REMOVED IN THEIR
ENTIRETY AND BACKFILLED WITH SAND. 1500 PSF BEARING CAPACITY IS
REQUIRED.
• OWNER AND CONTRACTOR SHALL VERIFY SPA LAYOUT AND ALL
DIMENSIONS, NOTIFY ENGINEER OF ANY CHANGES AND OBTAIN REVISED
PLANS FOR CHANGES.
• ALL HOSE BIBBS SHALL HAVE VACUUM BREAKERS.
• NO OVERHEAD WIRING WITHIN 10' OF SPA.
• ELECTRICAL EQUPMENT WIRING AND INSULATION SHALL CONFORM WITH
CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE OF THE NATIONAL
FIRE PROTECTION ASSOCIATION AND SHALL COMPLY WITH APPLICABLE
LOCAL CODES.
• ALL PIPING TO BE P.V.C. SCHEDULE 40 NON -THREADED NSF-PW APPROVED.
• ALL VALVES SHALL BE TAGGED AND WATERPROOF OPERATING
INSTRUCTIONS POSTED IN FILTER ROOM.
• DECK AREA OF SPA AS REQUIRED TO BE SLIP RESISTANT AND NON
PERVIOUS
• SPA SHELL SHALL BE LIGHT (PASTEL) IN COLOR SO AS TO REFLECT
RATHER THAN ASSORT LIGHT.
• STEPS TREADS
SHALL HAVE SLIP RESISTANT FINISH,
MIN. WIDTH 10"
EDGES SHALL HAVE CONTRASTING COLORED STRIPS 2" IN WIDTH.
• STEPS RISERS
EDGES SHALL HAVE CONTRASTING COLORED STRIPS 2" IN WIDTH,
HEIGHT SHALL NOT EXCEED 12" EXPECT BOTTOM WHICH IS ALSO THE
BECNH.
• ALL CONSTRUCTION SHALL COMPLY WITH CHAPTER 64E-9 OF THE STATE
OF FLORIDA DEPARTMENT OF HEALTH, FLORIDA ADMINISTRATIVE CODE
AND LOCAL BUILDING CODE.
• PROVISION SHALL BE MADE FOR VENTILATED STORAGE OF CHEMICALS
UNDER ROOF AND PROTECTION FROM ACCESS BY UNAUTHORIZED PERSONS
SPA RULES AND REGULATIONS
RULES AND REGULATIONS FOR BATHERS SHALL BE POSED NEAR SPA SIDE,
BE LEGIBLE FROM SPA DECK, LETTERING SHALL BE A MIN. ONE(I) INCH IN
HEIGHT, EXCEPT "NO DIVING ALLOWED" TO BE A MIN. FOUR(4) INCH IN HEIGHT
AND SHALL CONTAIN THE FOLLOWING:
I. NO ANIMALS IN SPA OR ON SPA DECK
2, NO FOOD, DRINK OR GLASS IN SPA OR ON DECK AREA.
3. SHOWER BEFORE ENTERING SPA.
4. BATHING LOAD 15 PERSONS.
5, SPA HOURS:DAWN TO DUSK
6. WATER TEMPERATURE NOT TO EXCEED 104' F
-1. NO DIVING ALLOWED.
8. CHILDREN UNDER 12 MUST HAVE ADULT SUPERVISION
S. PREGNANT WOMEN, SMALL CHILDREN, PEOPLE WITH HEALTH PROBLEMS
AND PEOPLE USING ALCOHOLNARCOTICS OR OTHER DRUGS THAT
CAUSE DROWSINESS SHOULD NOT USE SPA POOLS WITHOUT FIRST
CONSULTING A DOCTOR
10. MAXIMUM USE 15 MINUTES
FIRST AID EQUIPMENT
FIRST AID EQUIPMENT SHALL BE AVAILABLE FOR USE IN CONNECTION WITH
INJURIES WHICH MAY OCCUR IN THE SPA OR ON DECK.
1 1/2"
ANCHOR
UJ Dr-::PA1NC�40R [DETAIL
u.T.s.
12 VOLT TRANSFORMER
OR GP.I. (100 WATT)
TO EXISTING PANEL
3012 IN 1/2" COND.
NOTE:ALL ELECTRICAL
W.P. PANEL SHALL CONFORM
W/ ART. 680 N.E.0
IN POOL AREA GROUND
ALL BOXES, RAILS, LIGHT,
MOTOR, ECT. W/ 08 WIRE
ELECTRICAL DIAGRAM
NOTE: MATERIALS USE IN HEATER MUST BE NON -TOXIC
t ACCEPTABLE FOR POTABLE WATER USE.
2
100 WATT(UNDER WATER) LIGHT W/LOW WATER
CUT OFF DEVICE MIN. 18" BELOW WATER LINE
THERAPY JET PUMP 3 H.P.
RECIRCULATION PUMP 3 H.P.
X
IIIIII-111111=IIIIII
111111=111111=
Pyle
2 SECURED
GRATE
Sr<IMME R D TAi N.S.F. APPROVED)
N.T.s.
(2) 03 —LF
SKIMMER 1
WITH WALL
�f�f1 1�f R DETAIL
Rm
N
Im
IVA
(N.S.F. AFFFOVED)
N.T.s.
-
Y
•
-
xo
•
•
w -
-
14
•
•
NOTES:
5 FLOOR SHALL BE NON ABSORBANT, SLIP
IOESISTANT a SLOPED FOR DRAINAGE
r ALL EQUIPMENT IS ACCEPTABLE
AND DESIGNED FOR OUT DOOR USE.
ALL PIPING SHALL BE PAINTED TO
PROTECT IT FROM U.V. RAYS.
• EQUIPMENT AREA SHALL BE
ENCLOSED BY 5' CHAIN LINK
FENCE W/3' SELF CLOSING
AND SELF LATCHING GATE.
r MATERIAL USED FOR HEATER SHALL
BE NON -TOXIC AND ACCEPTABLE FOR
POTABLE WATER USE.
• 30 FOOT CANDLES OF LIGHTING
SHALL BE PROVIDED AT
EQUIPMENT LOCATION
AUTOMATIC AND MANUAL
FILL W/ 2" AIR GAP AND
HOSE BIBS 4 VAC. BREAKER
a
n
F
W
o
THERMOMETER z_1 W
Q
9 EROSION FEEDER 0_
WITH SOLENOID VALVE n
FROM HEATER
TO HEATER
CF-30250P
FLOW METER
(60-240 GPM)
2112" F_
L
PRESSURE GAUGES..
2" DIAM. FACE,
0-60 P51
AIR REL
VALVE
(TYP)
CAT 2000 PLUS
CONTROLLER
Q
Q N COLLECTOR TANK
Z - �300 GALLONS
TOTAL CAPACITY
ffim-
D.E. FILTER
EQUIFMENT RFLAN LAN VIEW
N.T.S.
LINE
3 H.P. SELF PRIMING
THERAPY PUMP
W/ HAIR 4 LINT STRAINER
2" WASTE LINE
W/ F AIR GAP
2112 � TO STORM SEWER
EQ(I/PMENT SCHEDULE
SOURCE OF WATER. PRIVATE POTABLE WATER SUPPLY
3 H.P. SELF PRIMING
RECIRCULATION PUMP
W/ HAIR 4 LINT STRAINER
SEPARATION
—TANK
SIGHT GLASS
VALVE SEQUENCE CHART
MATERIALS IN THE HEATER
ARE NON TOXIC AND ACCEPTABLE
FOR POTABLE WATER USE
ro
CF-30250P FLOW
FLOW METER (60
m
2 1/2" PRESSURE GAUGE
( 0 - 60 PSI ) ( TYP )
AIR RELIEF
VALVE S
(TYP)
VALVE
OPERATION
1
2
�3
4
5
6
NORMAL
OCCCOC
BACKWASH
C
O
O
C
C
C
PRECOAT
12CCCCO
C
C
O
C
C
START UP
O
11
NOTE: CHEMICALS SHALL BE STORED IN A COOL
DRY AND WELL VENTILATED AREA UNDER A ROOF
AND THE AREA SHALL BE INACCESIBLE TO THE
PUBLIC. CHEMICALS WHICH EMIT CORROSIVE FUMES
SHALL NOT BE STORED IN THE EQUIPMENT ROOM
CAT 2000 PLUS
CONTROLLER
NOTE: AIR GAP LEVEL Up
�
NOTE: FEEDER SHALL W/SPA WATER LEVEL
iS'OI-A16 .14A- Imes HAVE RATE OF FLOW AUTOMATIC AND MANUAL
INDICATOR AND FLOW FILL W/ 2" AIR GAP AND
EROSION FEEDER CONTROL VALVE. HOSE BIBS 4 VAC. BREAKER
WITH SOLENOID VALVEpP-P 141
THERMOMETER
3 H.P. SELF PRIMING �
RECIRCULATION PUMP
W/ HAIR 4 LINT STRAINER
L
IN
2112" TO WASTE
SIGHT GLASS
3
ti
WASTE LINE TO
STORM SEWER
FILTER TANK DRAIN LINE
W/ P AIR GAP
�-DE. FILTER AIR RELIEF
VALVE
(TYP)
C=CLOSE PIPING SCHEMATIC
O=OPEN OTE: MULTI PORT VALVES MAY BE USED
OVIDED IT ALLOWS FOR SAME VALVIN N.T.S.
OPERATION AS SHOWN
IT.
ITEM
MANUFACTURER
MODEL NO:
DESCRIPTION
MAIN DRAIN, FRAME 4 GRATE
HAYWARD
SP-1032
12" x 12"
3 H.P. THERAPY PUMP W/HAIR 4 LINT STRAINER
PUREX-TRITON
WF-12
SELF PRIMING
(150 GPM • 00 TDA4)
"4R
3 H.P. RECIRC. PUMP W/HAIR 4 LINT STRAINER
PUREX-TRITON
WF-12
SELF PRIMING
(110 GPM • 10 TDH)
60 S.F. DE. FILTER
PURER -TRITON
FNS-60
NSF. APPROVED
2.5" FLOWMETER (60 TO 240 GPM)
BLUE WHITE
CF-302501=
EROSION FEEDER PPD^
D ADJUSTME NT VALVE
W / RATE OF FLOW
NSF APPROVED AUTO SURFACE SKIMMER
EAU
AL. r-
50-6310
NSF APPROVED
TEST KIT
TAYLOR
2005
THERMOMETER
LETRO
SL-IDW
2" PRESSURE GAUGE
ASHCROFT
GPD-26
0-60 PSI
STATIC FITTING
PURER TRITON
46114100
COLLECTOR TANK
COM-PAC
F-300
300 GALLON TANK
LIGHT NICHE
STA-RITE
5161-235-1
LIGHT 12VI00 W/LOW WATER CUT OFF
STA-RITE
5501-2206
50' CORD
10
THERAPY JETS-GUNITE MICRO'SSAGE
HYDRO AIR
16-5215
I
S.S. HANDRAIL
S.R. SMITH
HR-12
I
HEATER
LAARS
400,000 BTU
PROPONE HEATER
DE. SEPARETION TANK
PAC-FAB
PF-1050
RATED FOR 60 SP.
I
CAT 2000 PLUS CONT.W/FLOW CELL KIT
CAT
2000 PLUS
W/AC075 CHL 4 PH
8
RETURN INLETS
HAYWARD
SP-1022 4 SD1419D
HYDRAULIC
DATA
PIPE
FLOW RATE
VELOCITY
21j2" RETURN INLETS
110 G.P.M.
1.4 F.P.S
6" MAIN DRAIN
260 G.P.M.
2.9 F.P.S.
2112" SKIMMER
66 G.P.M.
43 F.P.S.
3" THERAPY JETS
150 G.P.M,
roB F.PS.
RETURN INLETS 110 G.P1'9 / 8 INLETS 13.15 GALLONS/INLET
u
3
3 H.P. SELF PRIMING
THERAPY PUMP
W/ HAIR 4 LINT STRAINER
VALVE LEGEND
GATE VALVE
PROPORTIONAL
FLOW VALVE
G v
P�
5�
�
300 GALLON
COLLECTOR TANK
W/ LOCKABLE LID.
SCNNIVtU
St Luc a County
w CASTLE PINES @ PGA VILLAGE
DATE:
Ike i"
t 1/26/99
DAVlc 1. FaS.� I.ari, ,-F.
H.CENO:
L'CENSE 0.41646
99988-I1S
5155 Powerl1r"e Road
Fort Lauderdale, Florida 3330E
INC. SHEET
4OF4
t
r
•
r
•
•
s.:
•
•
•
•
•
•
•
•
a
•
i