Loading...
HomeMy WebLinkAbout1902-0598 WINDSTORM FRAME INSTALLATION INSTRUCTIONSWi IAdoa all g F0260 R1 SINGLE SWING 3070 t 100 PSF MAX. DESIGN 4080 t 70 PSF MAX. DESIGN 4" MIN./14" MAX. DEPTH 16 GA. MIN. KD OR WELDED (12 GA. WEL IMPACT RATING = 350 FT—IJ Frame Installation Instructions For Use With FL 4553 ON& 4" FACE FRAME HFAD II II II II — II II II II\ II II \ II II OPTIO II I,I HARDW II II OR h II II MULLI II 11 II II DOUBLE II II II II II II II II LOAD _OAD )ED) BF 8080 MAX. 4" MIN./14" MAX. DEPTH 16 GA. MIN. KID OR WELDED 0 2 GA. WELDED) DESIGN LOAD = +/-70 PSF IMPACT RATING = 350 FT—LBF ANCHORS & MEfHO OF ATTACHMENT ANCHOR TYPE *LOCATION EO — PIPE & SLEEVE (BUTTERFLY UP TO 3070 MAX.) 12" MAX. FROM EACH WOOD BUCK END & 19" O.C. 3/8" X 6" LAG SCREW EO — PIPE & SLEEVE (BUTTERFLY UP TO 3070 MAX.) 12" MAX. FROM EACH MASONRY BUCK END & 19" O.C. 3/8" X 6" EXPANSION SHELL MASONRY "T" — GROUTED 16" — 24" O.C. (Head: 3/8" x 6" Expansion Shel) @ GROUT JOINTS WIRE MASONRY —• GROUTED 16" — 24" O.C. (Head: 3/8" x 6" Expansion Shel) @ GROUT JOINTS WOOD STUD 6", 6" & EQUAL — 21" MAX. METAL STUD FOR INTERMEDIATE SPACES (NO FLOOR -ANCHORS) Poured In Place Wall NA *FOR DOUBLE SWING FRAMES WITH 4" FAC WHEN INSTALLED IN MASONRY WALL OR (2 IN STUD WALL LOCATION OF ANCHORS TI OR CAN BE GROUTED FULL WITH 2O00 PSI **FOR SIZES 6070 OR LESS REFER FRAME HEADS, (2) EO ANCHORS REQUIRED Ii STUD ANCHORS REQUIRED WHEN INSTALLED 1 BE 16" FROM CENTERLINE OF FRAME HEAD, MIN. CONCRETE. TO TABLE ABOVE. THREE -SIDED FRAMES ElCecoDoor ASSAABLOY SCANNED By Trio & Trio—E Opening **Sizes Over 6070 Pairs LOCATION @ Jamb:12"Max. From Each End & 19" O.C. @ Head: (4) Total Req'd, 9" Max. From Centerline of Head, 9" Max. from Each Hinge Jamb @ Jamb:12"Max. From Each End & 19" O.C. @ Head: (4) Total Req'd, 9" Max. From Centerline of Head, 9" Max. from Each Hinge Jamb @ Jamb:16"-24" O.C.@ Grout Joints @ Head: (4) Total Req'd, 9" Max. from Centerline of Head, 9" Max. From Each Hinge Jamb. @ Jamb:16"-24" O.C.@ Grout Joints @ Head: (4) Total Req'd, 9" Max. from Centerline of Head, 9" Max. From Each Hinge Jamb. @ Jamb:6", 6" & Equal-21" Max for Intermediate Spaces. @ Head: (4) Total Req'd, 6" Max. From Centerline of Head, 6" Max from Each Hinge Jamb NA Page 1 of 15 F0277,. Windstor Frame Installation Instructions For Use With FL 4553 -q] ..SINGLE:: S _Y8 m ONCE JA a PRCIEILE +a a� L -t. II FRAME.'HEAD.' & LOCK JAMB PROFILE. -3O70. MAK. 5; 5/8 MiN.f.14 MAC', D:EPTH:: DIMPLED HDLES�- 6 GA: ;WELDE•D ONLY 901H FAMS DESIGN LOAD;. = +.f-6a R5F (WITHC}LJT ... D I LT DES. GN LOAD..._-. +: 70 `.PSF. (WITH [?EADBOLT} IMPACT RATING 350 FT-18F j: a, AN HDRS k METHOD OF ,ATTACHMENT ANCHOR TYPt LOCATION :PLUMB: NCHOR;' ..ANCHOR,. ToP'..,PLUMB„ANCHOR,. &` STD LbC' +HOOD STUD SCREW BTM .P*Lb*mY . ,NC'HGR OR 9;; 15:" mm =FFRQ M METAL ST D : SCRE1+t' BIM OF FRAME: THREE -SIDED FRAME Meco Door a AB" Page 2 of 1S ITS F0291 KD OR WELDED (12 GA WELDED) DESIGN LOAD=+/-150 PSF IMPACT RATING = 35D FT LBF 4" Seotbn &a 193 mh.) lintel 96 " Max. Opening .625" Max n Frame Installation Instructions For Use With FL 4553 100" 96" Max. Opening Head Anchor (Bolts Only) Locations Max. FRAME MATERIAL 14 GAGE(.067 MIN.) COLD ROLLED OR GALVANIZED (A60) STFBL 4" MIN. FRAME DEPTH. &3 Anchors Equaly Spaced (see note#3) 2" Min. B--J _ 4" Max. 6" M�ax.T ' m 12 A O L =r O Cr —s N D m 'o .G 0 C O o� � r rn IN o 6" Max. u► C B+-i Intertior View Pair 8080 max for pairs, 4080 max. for singles. Single openings are described in active leaf of pair. EO anchor locations shown. MT or WM jamb anchors are optional. EO bolts only option for header. (2) EO bolts in header up through 30" singles. (3) bolts up through 40" singles. (4) bolts up through 6'0" pairs and (5) bolts up through 8'0" pairs. Hinge (4.5 x 4.5 x .180) locations are Ceco standard. Curries & Fleming locations are optional or+/- 1" of any locations tested. �) Frame header is reinforced for 12 gauge lintel. �) Frame is prepared for approved Multi -point lock and surface bolts for pairs and approved Multi -point lock for singles. q)Frame header is prepared for surface bolt strike. Preparation is indoor rabbet for inswing as shown and preparation is in soffit for outswing. THREE -SIDED FRAME C= ao = S"Cbn C-C Page 3 of 15 i Frame Installation Instructions For Use With FL 4553 F0260_A "OPTIONAL 4" FACE FRAME HEAD - lil SINGLE 3070 MAC. 4" MIN./14" MAX. DEPTH 16 GA. M N. KID OR WELDED (12 GA. WELDED) DESIGN LOAD = +/-100 PSF IMPACT RATING = 1350 FT-LBF vas "Rio SIdV f WY VME6 1DRS T Om�RYbl 7 Mf YN S YN f W% SSTYAZ OONVENMM PWFQE WJiffB xvs OovRalbl t" Spa f uuc Om/RaEE�i � �REB xia T r�mu fu�R n NENF PROFIlE *ANCHORS & METHOD OF ATTACHMENT ANCHOR TYPE *LOCATION EO - PIPE & SLEEVE (BUTTERFLY UIP TO 3070 MAX.) 12" MAX. FROM EACH WOOD BUCK END & 19" O.C. 3/8" X q LAG SCREW EO - PIPE & SLEEVE (BUTTERFLY UP TO 3070 MAX.) 12" MAX. FROM EACH MASO RY BUCK END & 19" O.C. 3/8" X 6" XPANSION SHELL MASONRY "T" - GROUTED 16" - 24" O.C. @ GROUT JOINTS WIRE MASOi RY - GROUTED 16" - 24" O.C. GROUT JOINTS WOOD ME�AL STUD STUD 6", 6" & EQUAL - 21" MAX. (NO FLOOR ANCHORS) FOR INTERMEDIATE SPACES Poured n Place Wall NA THREE SIDED FRAMES PaCecoDoor ASSAABLOY Page 4 of 15 Wi i Frame Installation Instructions For Use With FL 4553 1. DESIGN PRESSURE = +/— 60 P f IMPACT RATING = 350 FT—LBF 2. ALL FRAME PERIMETERS & HEADS OF FASTENERS SEALED WITH SILICONE 3. CORNER CONSTRUCTION = WELDED ONLY 4. ANCHORS = SEE CHART BELOW 5. FRAME DEPTH = 4" MIN. / 14" MAX. 16 GA IN. F0261 FRAME ELEVATIONS 3,. GLAZING DIM. B" DIM. "C" DIM. "D" DIM. "E" FRAME FACES DIM. 'A MATERIAL MAX. MAX. MAX. MAX. MIN. MAX. •GLASSLAM SAFETY PLUS 2 36" 72" 36" 94" LAMINATED GLASS 6. DOOR OPENING = 3'-0" X 8'-0' SINGLE MAX. 6'—O"" X 8'-0' PAIRS MAX. .BEDDING IS CLOSED,CELL FOAM TAPE 1/5' X 1/2" AND DOW CORNING 995 STRUCTURAL 7. STOP HEIGHT = 5/8" MIN. SIUCONE. 1 3/4" STEEL STIFFENED, HONEYCOMB, POLYURETHANE, MINERAL CORE OR B. FULL HEIGHT VERTICAL & 6' NOR ZONTAL POLYSTYRENE CORE PANELS (18 Go Min — 14 Go Max) MAY BE USED IN LIEU OF GfASSLAM. PANELS ARE WELDED TO FRAME WITH WELDS LOCATED ON THE SIDES 3" MAX. MULLIONS MUST BE REINFORCED WITH FROM EACH END & 3" MAX. O.C. & ON THE TOP & BOTTOM 3" MAX. FROM EACH END & (2) 10—GAUGE X 3/4" X FRAME DEPTH AT 12" MAX. O.C. THE WELDS ARE MIN. 1/4' WELDS X 1/2" LONG. PANELS TO BE "C" CHANNELS INSTALLED BACK 0 INSTALLED IN EXTERIOR (OUTSIDE) RABBET_ WELDS ARE LOCATED WHERE PANEL ABUTS BACK TO FORM SIMULATED "1" B♦SAM. FRAME SOFFIT. PANELS ARE SEALED WITH SILICONE. c n 11 "A —A" ANCHORS & METHOD OF ATTACHMENT ANCHOR TYPE LOCATION EO — PIPE & SLEEVE OR BUTTERFLY WOOD BUCK 3/8" X 6" LAG SCREW 0 JAMB 12" �AX. FROM SILL, 8" FROM HEAD & 20" O.C. 0 HEAD 2" ­2 " FROM EACH VERTICAL MEMBER & 14" O.C. 0 SILL 2" F OM EACH VERTICAL MEMBER & 0 MIDSPAN .EO — PIPE & SLEEVE OR BUTTERFLY MASONRY BUCK /8" X 6" EXPANSION SHELL 0 JAMB 12" AX. FROM SILL" 8" FROM HEAD & 20" O.C. 0 HEAD ••2" IFROM EACH VERTICAL MEMBER & 14" O.C. 0 SILL 2" Ff OM EACH VERTICAL MEMBER & 0 MIDSPAN WIRE MASONRY OR MASONRY "T" — GROUTED, WELDED TO STEEL HEADER, EO 8- OR BUTTERFLY — 3 8" X 6" BOLTS 0 JAMB 8' f6. FROM EACH END & 16" O.C. 0 HEAD •••W LDED TO STEEL CHANNEL HEADER 0 SILL 2" FpOM EACH VERTICAL MEMBER & 0 MIDSPAN I WELDED TO STEEL BUCK 0 JAMB •••51 MAX. FROM SILL & 27.5" MAX. O.C. 0 HEAD •••W LDED TO STEEL CHANNEL HEADER 0 SILL 2" FROM EACH VERTICAL MEMBER & 0 MIDSPAN WOOD STUD METAL STUD (NO FLOOR ANCHORS) 0 JAMB 0 HEAD 5" MAX. FROM SILL & 27.5" MAX. O.C. '•2" M . FROM EACH VERTICAL MEMBER & 14" O.0 0 SILL 2" FROM EACH VERTICAL MEMBER & 0 MIDSPAN --FOR 6' & UP HEAD MEMBERS. FOR HEADS LESS THA� 6". LOCATE ANCHORS 2' MAX. FROM EACH VERTICAL MEMBER & 0 MIDPOINT OF SPAN: •'•1/4' THICK MAX. SHIM PLATES (2' WIDE X 7' LONG OR TO SUIT JAMB DEPTH) WELDED TO STEEL CHANNEL & FRAMES WELDED TO SHIM PLATES. SHIM PLATES TO BE 1-1/4' GREATER THAN JAMB DEPTH. HEADER WELDS LOCATED 3" FROM EACH JAMB & 3" FROM EACH SIDE OF VERTICAL MULLIONS & 0 MIDPOINT OF SPAN OF HEAD ABOVE DOORS. WELDS ARE MIN. 3/ 6" X 1" LONG. SHIM PLATES ARE PROVIDED BY OTHERS. AFTER WELDING FRAME TO SHIMS, CAULK GAP BETWEEN FRAME AND STRUCTURAL STEEL CHANNEL WHERE SHIM PLATES ARE VOID. LITE AND TRANSOM FRAMES CCecoDoor ASSAA MOY DEPTH — 1/4- 0 GAUGE 0.750 0.750 ETAI L "A —A Page 5 of 15 Windstorm Frame Installation Instructions For Use With FL 4553 1. DESIGN PRESSURE = +/— 60 PSF IMPACT RATING = 350 FT—LBF 2. ALL FRAME PERIMETERS & HEADS FASTENERS SEALED WITH SILICONE. 3. CORNER CONSTRUCTION = WELDED 4. ANCHORS = SEE CHART BELOW 5. FRAME DEPTH = 4" MIN. / 14" M 16 GA. MIN 6. STOP HEIGHT = 5/8" MIN. 7. FULL HEIGHT VERTICAL & C HORIZ MULLIONS MUST BE REINFORCED N (2) 10—GAUGE X 3/4" X FRAME [ "C" CHANNELS INSTALLED BACK TC BACK TO FORM SIMULATED "I" BEA 12'-8" MAX. F0262 A" NC , 10'-6" s OTE MAX. C CI A A AI NS. FRAME FACES DIM. DIM. MAX. EXPOSED GLAZING "B" "C" GLAZED DIM. "A" MATERIAL MAX. MAX. zAREA (in.) MIN. MAX. *GLASSLAM SAFETY PLUS 2 2" 4" 72" 94" 3384 LAMINATED GLASS 'BLUUINO IS cLUSLU ULLL rUa ,art 1/0 A ,/t ^^� SILICONE. 1 3/4' STEEL STIFFENED, HONEYCOMB, POLYURETHANE, MINERAL CORE OR POLYSTYRENE CORE PANELS (18 Go Min — 14 Go Max) MAY BE USED IN LIEU OF GLASSLAM. PANELS ARE WELDED TO FRAME WITH WELDS LOCATED ON THE SIDES 3" MAX. FROM EACH END & 3" MAX. O.C. & ON THE TOP & BOTTOM 3" MAX. FROM EACH END & AT 12" MAX. O.C. THE WELDS ARE MIN. 1/4' WELDS X 1/2" LONG. PANELS ARE SEALED WITH SILICONE. ANCHORS & METHOD OF ATTACHMENT ANCHOR TYPE I I LOCATION EO — PIPE & SLEEVE OR BUTTERFLY WOOD BUCK 3/8" X 6" LAG SCREW ® JAMB 12" FROM SILL, 8" FROM HEAD & 20" O.C. ®HEAD ••2" F1ROM EACH VERTICAL MEMBER & 14" O.C. 0 SILL I 2"FROM EACH VERTICAL MEMBER & ® MIDSPAN EO — PIPE & SLEEVE OR BUTTERFLY MASONRY BUCK /8" X 6" EXPANSION SHELLS & JAMB 12' MAX. FROM SILL, 8" FROM HEAD & 20" O.C. ® HEAD • 2" FROM EACH VERTICAL MEMBER & 14" O.C. 0 SILL I 2"'FROM EACH VERTICAL MEMBER & ® MIDSPAN WIRE MASONRY OR MASONRY "T" — GROUTED, WELDED TO STEEL HEADER. EO P&S OR BUTTERFLY — 3 B" X 6" BOLTS ® JAMB B" M FROM EACH END & 16" O.C. ® HEAD ­WEDED TO STEEL CHANNEL HEADER ® SILL E 2" F OM EACH VERTICAL MEMBER & ® MIDSPAN WELDED TO STEEL BUCK 0 JAMB ••15"1 MAX. FROM SILL & 27.5" MAX. O.C. 0 HEAD -WELDED TO STEEL -CHANNEL HEADER ® SILL 1 2" FROM EACH VERTICAL MEMBER & 0 MIDSPAN WOOD STUD METAL STUD (NO FLOOR ANCHORS) ®JAMB ® HEAD 5" MAX. ••2AX. " M FROM SILL & 27.5" MAX. O.C. FROM EACH VERTICAL MEMBER & 14" O.0 ® SILL 1 2" F OM EACH VERTICAL MEMBER & ® MIDSPAN "FOR 6' & UP HEAD MEMBERS. FOR HEADS LESS TNA 6', LOCATE ANCHORS 2' MAX. FROM EACH VERTICAL MEMBER & 0 MIDPOINT OF SPAN. •••1/4" THICK MAX. SHIM PLATES (2' WIDE X 7' LONG OR TO SUIT JAMB DEPTH) WELDED TO STEEL CHANNEL & FRAMES WELDED TO SHIM PLATES. SHIM P TES TO BE 1-1/4' GREATER THAN JAMB DEPTH. HEADER WELDS LOCATED 3' FROM EACH JAMB & 3" FROM EACH SIDE OF VERTICAL MULLIONS & 0 MIDPOINT OF SPAN OF HEAD ABOVE DOORS. WELDS ARE MIN. 3/116" X 1' LONG, SHIM PLATES ARE PROVIDED BY OTHERS. AFTER WELDING FRAME TO SHIMS, CAULK GAPSI BETWEEN FRAME AND STRUCTURAL STEEL CHANNEL WHERE SHIM PLATES ARE VOID. BORROWED LITE FRAMES C=CecoDoor ASS MIJOY ,I DEPTH — 1/4" _ I 0—GAUGE �0.750 0.750 ETAI L "A —A; Page 6 of 15 Windstor' Frame Installation Instructions For Use With FL 4553 GLASSLAM SAFETY PLUS II 1/8' X 1/2' CLOSED CELL FOAM TAPE PET FLAP REQUIRED GLASS MAY BE INSTALLED ON EITHER SIDE OF THE FIXED FRAME STOP. W CORNING 5 SILICONE -18x1-1/2' OVAL HEAD EK SCREW i i 5/8' 5/8' l I DOW CORNING 995 SILICONE GLASSLAM SAFETY PLUS II DOW CORNING 995 SILICONE 1/8' X 1/2' CLOSED CELL FOAM TAPE PET FLAP REQUIRED CORNING SILICONE 1.) BEFORE REMOVING THE REMOVABLE STOPS, USING A PENCIL, MARK ALIGNMENT MARKS (IN THE STOPS AND THE FRAME, 2.) UNSCREW THE #8 X 1-1/2' OVAL HEAD TEK SCREWS FROM THE REMOVABLE STOPS AND REMOVE THE STOPS. 3.) WIPE THE FIXED STOP CLEAN AND THEN APPLY THE CLOSED CELL FOAM TAPE TO THE FIXED STOP.' 4.) IF THERE ISi PLASTIC RELEAS ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK ABOUT 2'•FROM EACH END OF THE FOAM TAPE. PULL THE PLASTIC RELEASE ABOVE THE FIXED STOP S❑ IT CAN BE GRASPED AFTER PLACING THE. GLASSLAM ON THE UNEXPOSED FOAM TAPE. STEP 5-MAY REQUIRE THE ASSISTANCE OF ANOTHER PERSON TO HELP HOLD THE GLASSLAM IN PLACE. 5.) IF THERE IS PAPER RELEASE ION THE FOAM GLAZING TAPE, REMOVE THE PAPER RELEASE BEFORE GLAZING. SPRAY THE EXPOSED FO M TAPE WITH A MILD SOAP SOLUTION IMMEDIATELY BEFORE PLACING THE GLASSLAM ON THE EXPOSED ❑AM TAPE. 6.) PLACE GLAZING SHIMS, AS NE DED, THEN SET THE GLASSLAM ON THE FOAM GLAZING TAPE. 7.) ADJUST HE GLASSLAM ASSEMB Y, AS NECESSARY, TO CENTER THE ASSEMLY IN THE OPENING. 8.) IF THE RELEASE IS PLASTIC, GRASP THE FREE END OF THE PLASTIC RELEASE, WHILE HOLDING THE GLASSLAM T❑ KEEP IT FROM MOVING. THEN SLOWLY PULL THE RELEASE OFF THE FOAM TAPE THAT WAS APPLIED TO THE FIXED STOP, PRESS THE GLASSLAM AGAINST THE FOAM TAPE. 9.) INSERT A PUTTY KNIFE BETWEEN THE PET FLAP AND THE FRAME RABBET. USING THE PUTTY KNIFE PULL THE PET FLAP UP AND OFFI THE FRAME RABBET. 10.) WHILE HOLDING THE PET FL P BACK AWAY FROM THE FRAME RABBET WITH THE PUTTY KNIFE, USE A CAULKING GUN TO APPLY DOW CO NING 995 SILICONE BETWEEN THE PET FLAP AND THE FRAME RABBET. IMPORTANT: ENSURE THAT TH DOW CORNING 995 SILICONE FULLY WETS OUT OR COVERS THE PET FLAP AND COMES IN CONTACT WITH THE FRAME RABBET. 11.) SLOWLY MOVE THE PUTTY KNIFE AROUND THE FRAME AHEAD OF THE CAULKING GUN AND APPLY THE SILICONE AROUND THE ENTIRE OPENING BETWEEN THE PET FLAP AND THE FRAME RABBET. 12.) APPLY 1/8' X 1/2' CLOSED (ELL FOAM TAPE TO THE REMOVABLE STOP. 13.) IF THERE IS PLASTIC RELEA E ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK ABOUT 2' FROM EACH END OF THE FOAM TAPE. PULL THE PLASTIC RELEASE ABOVE THE REMOVABLE STOP S❑ IT CAN BE GRASPED AFTER PACING THE REMOVABLE STOPS AGAINST THE GLASSLAM. 14.) IF THERE IS PAPER RELEAS ON THE FOAM GLAZING TAPE, REMOVE THE PAPER. SPRAY THE EXPOSED FOAM TAPE WITH MILD SOAP SOL TION IMMEDIATELY BEFORE PLACING THE REMOVABLE STOPS AGAINST THE GLASSLAM. 15.) USING THE ALIGNMENT MARK , POSITION THE REMOVABLE GLASS STOPS AGAINST THE GLASS. IF STOPS ARE TOO TIGHT LIGHTLY GRIND HE END OF STOP FOR ADDITIONAL CLEARANCE. 16.) INSTALL AND TIGHTEN THE 8 X 1-1/2` OVAL HEAD TEK SCREWS IN THE REMOVABLE STOPS, BE CAREFUL NOT TO OVER TIGHTEN. 17.) IF THE RELEASE IS PLASTIC GRASP THE FREE END OF THE PLASTIC RELEASE TAPE AND SLOWLY PULL THE PLASTIC RELEASE OFF THE FOAM TAPE, 18.) TRIM THE PET FLAP AS NEEDED. 19.)USING THE DOW CORNING 995ISILICONE OR OTHER HIGH QUALITY SILICONE, APPLY A SMALL CAP BEAD OVER THE CLOSED CELL FOAM TAAPE. 1' = 25.4 mm, e.g„ 1-3/4' = 44.45 mm) 9-217 07/01/15 HURRICANE RESISTANT FLAMES-GLASSLAM SAFETY PLUS II GLAZING INSTRUCTIONS C=—C=Door ASMABLOY Page 7 of 1S Windstor I Frame Installation Instructions 7For Use With FL 4553 F0292 3/4" LEG OF "C" CHANNELS FULLY WELDED TO FRAME NOTE: 1. MULLIONS MUST RUN THROU REINFORCED WITH 10 GAUGE V IN LENGTH. 2. 10 GA. "C" CHANNELS MUST B ON EACH END. 3. EQUALLY SPACED AT EACH E FACE V CONTINUOUSLY WELDED ON BOr acC IYV1G 1 70" MIN .118" MAX 10 "C" CHANNEL I1 I� III 0.75" I PROFILE WIDTH I� -1/4' ���111 'H HEADS, SILLS, OR JAMBS AND BE "C" CHANNELS (ITEM 10) IF EQUAL TO OR GREATER THAN INSTALLED.BEFORE WELDING TOGETHER. OFFSET 3/4" OF MULLION. FRAME1CONSTRUCTION AND MULLION DETAIL "" BEAM CONSTRUCTION DETAILS Meco Door ASSA ABIJOY Page 8 of 15 F0263 TF2SL TFLSL * OPTION: ARCHED U LSL RSL LPSL RPSL I Frame Installation Instructions For Use With FL 4553 N ITS TFRSL 2SL P2SL VARIES WINDOW FRAME ABOVE FLOOR TF TFLPSL ARCHED FRAMES TF2PSL TFRPSL SLOPED FRAMES WINDOW FRAME ON FLOOR ALTERNATE FRAME DESIGN Meco Door ASMAs" Page 9 of 15 Windstor Frame Installation Instructions tFor Use With FL 4553 F0282 CONVENTIONAL FRAME CORNER ASSEMBLY SLOTS FOR CORNER TABS BEND CORNER TABS TABSTOWARD INSIDE OF I FRAME SLOTS FOR JAMB IAB JAMB TABS Install rubber isilenct frame is setup to a...._ , ___ pluggin� holes. HEAD BEND JAMB TABS TOWARD OUTSIDE OF FRAME DRYWALL FRAME CORNER ASSEMBLY #8 x 1/2" MIN. PHSMS JHIVIO CORNER ASSEMBLY 17-1 Ia DOOR OPG AT HEAD _I SPREADER Typical wood spreader must be square and made SQUARING THE FRAMq from lumber at least 1" thick. Length of spreader The installer should use wood spr aders, equals door opening width at the head. Cut clear — a carpenters level and a carpenters square. once notches for frame stops as shown. Spreader Set the frame in the desired location. Level must be nearly as wide as frame depth for proper head and plumb jambs. Shim under jambs if installation. necessary. KD FRAME CORNERS C—Cecowor I AM MIJOY Page 10 of 15 0 n Frame Installation Instructions For Use With FL 4553 Pocket Provided for 1/2 or 5/8" thick wall board 0 0 Flush with stud _� 2" Snap -in hype U/ METAL STUD ANCHOR Pocket provided for 1/2" or 5/8" thick wall board l Flush with We stud METAL STUD ANCHOR Pocket Provided for 1/2' or 5/8" thick wall board ded 11z 11 WOOD STUID "Z" STRAP ANCHOR EXISTING OPEN ING ANCHOR F0283 l Welded METAL STUD "Z" ANCHOR Pocket provided for 1/2" or 5/8" thick wall board 0 o � Flush o with stud --� 2" i Snap -in type WOOD STUD ANCHOR (Used also for METAL STUD Walls) STUD WALL FRAME ANCHORS CCecoDoor AMAB" M Page 11 of 15 Snap —in type WIRE MASONRY ANCHOR YOKE AND STRAP MASONRY ANCHOR Welded EXISTING OPENING ANCH POURED IN PLACE W F0284 A 7Frame Installation Instructions For Use With FL 4553 MIME 01II], MASONRY "T" ANCHOR Bend in field to fit. \� Snap -in type MASONRY "T" ANCHOR (ADJUSTABLE) _ ' z" �— Snap —in type EXISTING OPENING ANCHOR I Welded o\ STANDARD FLOOR ANCHOR IRY WALL FRAME ANCHORS Mao= ASSA MLOY Page 12 of 15 Windstor ' Frame Installation Instructions 7For Use With FL 4553 FOR STEELSHIM LOCATIONS . SEE "SIDE LITE TRANSOM FPWES", PAGE 5 AND "BORROWED LITE FRAMES", PAGE 6 4" MAX. A-36 STEEL SHIM PLATE EXT FRAME WELDED TO SHIM WITH 3-" x 1" LONG FLARE BEVEL WELD BOTH SIDES OF FRAME WITH E6018 ELECTRODES 4" MAX. THICK A-36 STEEL SHIMS WELDED TO STRUCTURAL BUILDING MEMBER WITH FILLET WELDS MEASURING 2" LONG AND SHIM PLATE 1.25' SIZED TO THE SAME LINGER THAN FRAME JAMB DEPTH THICKNESS AS THE SHIM PLATE USING E6018 ELECTRODES WELD HOLLOW METAL FRAME TO SHIM WITH 16" x 1" LONG FLARE BEVEL WELDS, BOTH SIDES OF FRAME USING E6018 ELECTRODES '"MAX. THICK, 2" WIDE A-36 / STEEL SHIM PLATE(S), LENGTH 1.25" GREATER THAN FRAME AFTER WELDING FRAME TO SHIMS, JAMB DEPTH CAULK GAPS BETWEEN FRAME AND STRUCTURAL STEEL MEMBER WHERE SHIM PLATES ARE VOID. ' 9-214 (Conversi rr 1' = 25.4 nn, e.g., 1-3/4' = 44.45 nn) 12/07/12 RESISTANT FRAMES - SHIM PLATE DETAIL YCecoDoor A%AAB r Page 23 of 15 Windstor Frame Installation Instructions For Use With FL 4553 S44 P381 AND 385 312 312 P385 12' LONG PIECE OF P381 APPLIED ON LOCK JAMB DOOR RABBET STARTING AT SILL. REMAINDER OF JAMB IS P385. 346C 771 312 CN 12' LENGTH OF P381 APPLIED ON S771 3,81 THRESHOLD STARTING AT THE LOCK P385 JAMB. REMAINDER OF THRESHOLD WEATHERSTRIP IS P385, t—..75"—1.375r 5 ,, 375 \25, —�.375 ise �8 ❑]3 L^��.250 gEMMKKOO PEMKO PEMKO PEMKO PEMKO I 242 P261 P266 P381 P385 75 B 1 1.25 .43B .250 �1 .375 8 r.047 438 --� .4�38 �1j RS PEMKO PEMKO PEMKO PEMKO 312 S771 S44 315CN 6 .00 JJIIII___LL________ PEMKO 346C L PEMKO 2008 .5B WEATHER STRIP FOR WATER INFILTRATI❑N SINGLE DOORS PER • AS DESIGN PRESSURE 50 PSF F0305 WATER 11 IFILTRAT16N PREPARATIONS SINGLE SWING Meco Door ASSAABLQY Page 14 of 15 Windstorrh Frame Installation Instructions For Use With FL 4553 PAIR WITH RIM EXIT P385 AND HARDWARE MULLION P385 P266 312 WITH 12' LENGTH OF P381 APPLIED ON BOTH MO L HOLLOW METAL I ILL. ONRE MINDER OFRABBETS AMULLION RTING TISH 385. S771 root -,L37 t—rzso .375�—,.ase �3�3 rs�s-I�zso (PEMKO "I PEMKO PEMKO PEMKO PEMK❑� P242 P261 P266 P381 P385 aoo� zso z� .+ us .+39 a oa —:.38 2s PEMKO PEMKO PEMKO' PEMKO 312 S771 S44 315CN L,:=�i�o P�MKO 2008 6 8 m sn LPEMKO PEMK[ P255 so WEATHER I STRIP FOR WATER INFILTRATION PAIRS OF DOORS PER TAS 202 DESIGN PRESSURE 60 PSF F0306 WATER INFILTRATION PREPARATIONS STANDARD SWING PAIR CCecoDoor A%AAB" Page 15 of 15 UNDERWRITERS LABOP-�TORIES INC. FOLLOW-UP SERVICE PROCEDURE. DRAWN BY: TTH I MANUFACTURING & SERVICE CENTER LOCATIONS I PROJECT REF: TS03CL61 Ey IN EXTERIOR WITDOOIjsDIR AME R27576 HMA A250.13WINDSTORM RESISTANCE IMPACT RATING : 350 FT-LBS DESIGN LOAD RATING PSF LSO CLASSIFIED IN ACCORDANCE WITH 4ZBI ANSI/ASTM E330, ANSI/ASTM E1866, ASTM E7996, TAS-201. TAS-202 and/or TAP-203 7000746 The label design has the follo*ing information: 1. UL classified log 2. Ceco Door / ASSA ABLOY logo 3. UL assigned Conol Number (4ZB1) 4. Complimentary classification (Windstorm Resistant Frame) 5. Design Load Rat>ng & Impact Rating 6. ANSUASTUT IS Test Number References 7. Ceco part number (7000746) Labels will be metal with holes for fastener attachment. ISSUE FILE: R27576 M.Ceco dao AMABLYY VOL: 1 SEC: 1 WINDSTORM LABEL DETAIL (FRAMES) ILL: 7 BY Windstorm Door Installation Instructions „04 mmnoty For Use With FL 4553 . ,..- Class I Stiffness .. � rLockside Door Max. M1 Design, Mm Latch Throw (m) Min patch � Hardware Type` Conf� urat�on Type 9x Size Gaue k> _ Load h Strength (Ib1] E Medallionr Cyllndncal Lock, Legion 30 70; '/z" cyliridncal Mortise Lock Ultra ` InswmgJ „ x " morti e 630 (DeatlbOlt not Regent Outswmg Single a regwred) omega �t Fue o Medallion Legioncylindncal, 1",deadlock , �Ylmdncal,Lock x Inswing/ 30,X10 3/a" mortise deadbolt: Deadlock, Mortise :Ultra Outswmg Single ,1" act latch, 1" deadbolt 735 Lock w/deadbolt;;,; Regent: Omega, ti h (ICL) Interconnected lock fue o, x , Medallion ' " Mo i e Lock Legion a w ✓ ,r { y 3/a" mortise, 1" deadbolt ; wJdeadbolt, Rim' ': Ultra m Outswmg 80 18 5 +% 60 n rod exit h 20 Exit, Vertical Rod Single n/a mJvertical Regent a x xi xt r � ducal Loc k► Medallion '/ c lindr cal Z y �CyMn ortise;Lock Legion Ultra x 30 x 70 3%a" mortise lock 630 (Deadbolt not", putswmg Single- n/a mortise/nm/vertical .-require ,Mortise q ) Regent- Omega _: : rotl `exit w s Exit, Rim Exdt, ' *, r Vertical Rod Exit„:' Fue o Medallion k t'" t ,_ , Mortise Loc Legion :Ultra _ a 40 x 80 3/a" mortise; 1" deadbolt 1y120 w/deadboltk Re ent. 9 Outswing£ Single` 16 +/ 70 n/a urn vertical rod exit :. Rim Exit, Vertical Rod Exit s ;ue o r Mortise Lock Medallion w/deadbolt (active)'; - 3/a" mortise,, l Deadbolt / /Surface Bolts ... Legion 804,80 6 +/ 70 1'la"surface bolt 1120 inactive Vertical: ( )• Ultra Re Outswmg Pair °: n/a rim/vertical rod exit :. Rod x Vertical 9 ent> Omega; k Exit, Rmi, Exit x Mullion Stiffness Class L Continued'on *Glass lights may limit design loads. See details to follow for additional information. **Louvers are excluded from use with Trio and Trio-E Doors Optional All Door Series -1/2" max. diameter cutout for viewer. CCeco_Door Page 1 cWjnu AMAABLOY I Door Installation Instructions or Use With FL 4553 a ' X -Mortise Lock Outswmg 80 x 80 °: 3/a" mortise 1" deadbolt w/deadbolt (active) Fuego .1120 • Pair bolt J Surface Bolts r 11/4"surface inactive Medallion Regent- Inswing/ 4U x 80 14 s, ** 1 deadbolt 3/a, " 2400 Multi Point Lock r`: " flutswmg Single +/ . 150 mortise wJdeadbolt , Im e�ial ti 3/a" 1"deadbolt ` Multi Point Lock Medallion Regent` Inswing/. 80 x 80 14 **. mortise / 2400 w/deadbolt (active) Imperiaa Outswing r Pair „ . Surface Bolts 1 /a surface bolt w .inactwe *Trio Inswing% 30 x 70 /2" cylmdncal ` Cylmdncal Lock, z 18 +/ 100 3/a"mortise 'lock 1050 Mortise Lock w/^ Trio E . Outsw�ng Single, **Trio ' = Outswmg 30 x 70 ., 18 >� +/ 100 3/a"rim exit 1050 R�rn Exit Trio Sin le Cylindncal Lockx"` cylindrical Deadlock Mortise **Trio 70 /z" 1"deadloek Lock w/ deadbolt:` , Inswing/; 60 x Pair 18 +/ 70,735 3/a" function (active) '- Trio. Outswmg rriortise'lock, tlushbbit T< Flush Bolt or , 1" ., Surface Bolt (In " g :acctive ;**Trio ; Inswing) 4Q x 80/z" cylindrical Cylindrical Lock, wJ ' Trio E ` Outsw�ng Single 18 z +/, ,70 3/a" mortise dock 1120 Mortise Lock = ....: ,, ..,..: deadliolt:function.: *Trio ; 40 x 80 18 3/a",rim 1120 Rim Exit Trio E ; Outswing Single +/ :70 exitY %a" ricri exit x 3/a" rim Rim 'Exit **Trio K exit $ X Hardware Mullion Outswin9 80 x 80 = 18.3,:' 1120 'w :... Trio E .: Pair ��w:,' La Vertical Rod Exit x, Vertical R'od Exit x` 3/a" Ueitical Rod Ewt,< .Vertical Rod' Exit.:; } Cylindrical Lock:x=: Dea"dlock, 1/2"' cyl hdrical Mortise Lock. _ ** Trio , Inswing/ 80 x 80 18 �.+/- 70 1 „ �1120; w/Deadbolt ' Trio E CV swing Pair .deadlock 3 ". /a mortise. lock Function' (active) > ., Flush Bolton':. Surface Bolt "(Inactive) *Glass lights may limit desio loads. See details to follow for additional information. **Louvers are excluded fromluse with Trio, Trio-E. Glass lights and louvers are excluded from use with 150 PSF Doors. CCecoDoor Page 2 of 18 ASM ABLAY i Door Installation Instructions or Use With FL 4553 Max Mm Design z me Latch, Door , Configuration f Min Latch£Throw (In) Hardware Type Type Size Gauge Load° U Strer>tgth s5 Ibf .� Im`periai Inswing/ = 30 x 70%z" cyhndncal Mortise Lock Versadoor Outswmg ; Si:ngle/a" MO, IS 630 (Deadbolt'not` T require d 1/�2" Cylindrical'Lockx " nyllndrlCal�' 1" deadlock a 1 Deadlock, Mortise: Imperial Inswing/ = 30 x70 la mortise deadbolt ° 735 aLock w/deadbolt Versadoor Outswing - Smgle :'/z" act`aatch; l" deadbolt - ' Interconnected "(ICL') lock Imperial Inswing/_, 30`x 80 � 18 I +/- 60 `3 " � /a mortise 1 deadbolt 720 Mortise Lock h��; Versadoor Outswin Sm le i' =.w deadbolt L k i(2" cyhndricalt Mortise Lock Imperial 30,x 70 3/a" mortise ` 1 " 63,0 (Deadbolt'not Versadoor : Outswing - Single 18 +%=,60 _ „n/a mortise/rim/vertical regwre'd), Mortise rod exit Exit; Rim Exit, }: w, Vertical; Rod .E:d { :r Mortise Lock F^ Imperial - 30=x 80 3/a" mortise 1"deadbolt ' w%deadbolt' Rim Versadoor Outswm . g . Single 18 + - 60 . n/a rim/vertical rod exit 720 Exit, Vertical Rod Exit.t. Imperial ., Inswing/, 40 x 80 16 +/- 70 �: 3 „ /a mortise, 1 deadbolt 1120 Mortise Lock Versadoor Outswin .. Sin le w%deadbolt v , M Mortise Lock Imperial 40 x 80 -3/a" mortise, 1" dead,bolt w/deadbolt, Versadoor Outswmg, Single .. 16 - _ +,70 n/a rim/vefical rod exit 1120 r Rim Exit, Vertical 'Rod Exit£ Imperial; Outswing 60 x 70 . 18 '..' +/- 60 n/a rim exit 63J0 "Rim Exit x Mullion; Versadoor . 5 `,.Fair ,. a.. x. Imperial' , Outswmg 80 x 80 +/ 70 31a" mortise, 1."'deadbolt / rt 1120 w/deadbolt '` Versadoor ` pair .16 _ 1�/d" surface bolt (active) /Surface.: olts: inactive .. Imperial Inswing/, . Outswin - 40 x 80 Sin le . ,. 14 ;** + - .150 3/a mortise, 1 deadbolt " 2400 Multi; Po�nt:Lock z� uirdeadbolt , Multi Pomt<Lock ° Inswing/.` 80 x 80 ** 3/a" mortise 1" deadbolt / H►/.deadbolt Imperial Outswing Pair 14 +/ `150 1,%a" surface bolt 2400 (Active) Surface Bolts .Inactive *Glass lights may limit design' loads. See details to follow for additional information. **Louvers are excluded from use with Trio, Trio-E. Glass lights and louvers are excluded from use with 150 PSF Doors, MCecoDoor Page 3 of 18 ASS ABLOY Windstorm jDoor Installation Instructions F r Use With FL 4553 Vertically Stiffened Door CONSTRUCTION DETA LS HINGE 4 GAGE CLOS R PREPARATION 4GAGT D0235B \,,4:EIN1ORCEME (OPTIONAL) FIBER LASS INSULATION BETWEEN STIFFENERS — MINIMUM DENSITY 0.5 PCF . BOTTOM — FACE SHEET TOP FACE SHEET HINGE J EDGE LOCK RECESSED 16 GAGE BOTTOM CHANNEL 15 SPOT WELDED TO BOTH FACE SHEETS V1 VERTICAL SECTION THRU BOTTOM OF DOOR LOCK EDGE LOCK AND HINGE EDGES ARE BEVELED 1/8' IN 2" (10 6) SOUARE EDGE OPTIONAL RECESSED 16 GAGE TOP CHANNEL IS WELDED TO BOTH FACE SHEETS 18 GAGE CAP CHANNEL IS SCREWED TO INVERTED CHANNEL (OPTIONAL). CLOSER REINF. 14Gax6"x2O" VERTICAL SECTION THRU TOP OF DOOR STANDARD: CENTER EDGE SEAM VERTICAL EDGE SEAMS ARE VISIBLE WITH 18 GAUGE BACKUP CHANNEL FULL HEIGHT OF DOOR WITH OPTIONAL BONDO FILLED OR WELDED SEAMLESS EDGE AVAILABLE 1-3/4" OPTIONAL: TAB & SLOT MECHANICAL INTERLOCK WELD SEAMED EDGES GROUND SMOOTH ARE OPTIONAL 1-3/4" HORIZONTAL SECTION THRU LOCK EDGE Note: 1. Drawing Not To Scale 22 GAGE FORMED STEEL STIFFENERS (20 GAGE AND GALV STEEL OPTIONAL) POSITIONED NOT MORE THAN 6" APART AND SPOT WELDED TO BOTH FACE SHEETS AT 5" O.C. MAX HORIZONTAL SECTION THRU VERTICAL STIFFENER Steel -Stiffened Core Door Details Meco Door ASSA ABLY Page 4 of 18 HINGE PREPARATION BOTTOM - FACE SHEET Door Installation Instructions it Use With FL 4553 TRIO DOOR" CONSTRUCTION DETAILS 14 GAGE REINFORC (OPTIONA TOP FACE SHEET LOCK P FACE SHEETS 18 GAGE CRCQ STEEL (STANDARD) 16 GAGE CRCQ STEEL (OPTIONAL) GALVANIZED (A60) STEEL (OPTIONA D0295B R LOCK EDGE IS BEVELED 1/8" IN 2" HINGE EDGE IS PERPENDICULAR TO FACES HINGE BACKSET IS 1/4" (VARIES PER CONDITION) INVERTED (16 GAGE MIN., 14 GA. MAX.) TOP CHANNEL SPOT OR PROJECTION WELDED TO TOP & BOTTOM SKIN 18 GAGE CAP CHANNEL IS SCREWED TO INVERTED CHANNEL (OPTIONAL). 'POLYURETHANE INSULATION BETWEEN STIFFENERS DENSITY : 1.8-2.0 LBS/CUBIC FOOT 22 GA VERTICAL SECTION LINER THRU TOP OF DOOR LOCK EDGE 16 OR 18 GA. (WELDING OPTIONAL) VERTICAL EDGES ARE WELDED THE FULL HEIGHT OF DOOR AND DRESSED SMOOTH TO OBTAIN COMPLETELY SEAMLESS HINGE AND LOCK EDGES. 22 GA 1-3/4" LINER VERTICAL EDGES ARE CECO'S STANDARD HORIZONTAL SECTION TAB & SLOT THRU LOCK EDGE MECHANICAL INTERLOCK STANDARD 22 GAGE (20 or 18 GAGE OPTIONAL) FORMED STEEL STIFFENERS, POSITIONED NOT MORE THAN 6" APART, AND WELDED TO 22 GAGE LINER (5. O.0 MAX.). 22 GA LINER IATION 22 GA STIFFENER HORIZONTAL SECTION THRU VERTICAL STIFFENER INVERTED (18 GAGE MIN., 14 GA. MAX.) BOTTOM CHANNEL SPOT OR PROJECTION WELDED TO TOP & BOTTOM SKIN 22 GA LINER OPTIONAL CONTINUOUS BEAD OF STRUCTURAL 5 8" MIN. ADHESIVE APPLIED TO BOTH 1° MAX. VERTICAL SECTION FLANGES OF BOTTOM SKIN THRU BOTTOM OF DOOR Steel -Stiffened Core Door Details Meco mor Page 5 of 18 AMA ABLY WindstormlDoor Installation Instructions For Use With FL 4553 TRIO-E DOOR LOCK EDGE IS BEVELED 1/8" IN 2" CONSTRUCTION i DETAILS HINGE EDGE IS PERPENDICULAR TO FACES HINGE BACKSET IS 1/4" (VARIES PER CONDITION) 14 GAGE CLOSER REINFORCEM NT INVERTED (16 GAGE MIN., 14 GA MAX.) TOP HINGE (OPTIONAL) CHANNEL SPOT OR PROJECTION WELDED PREPARATION TO TOP & BOTTOM SKIN 'POLYU ETHANE INSULATION BEIWEE STIFFENERS 18 GAGE CAP CHANNEL IS SCREWED DENSI 1.8-2.0 LBS/CUBIC FOOT TO INVERTED CHANNEL (OPTIONAL). BOTTOM FACE SHEET 22 GA VERTICAL SECTION LINER THRU TOP OF DOOR FEDGEK 16 OR 18 GA. (WELDING OPTIONAL) VERTICAL EDGES ARE WELDED THE FULL HEIGHT OF DOOR AND DRESSED SMOOTH TO OBTAIN COMPLETELY SEAMLESS HINGE AND LOCK EDGES. 22 GA 1-3/4" LINER VERTICAL EDGES ARE CECO'S STANDARD HORIZONTAL SECTION TAB & SLOT THRU LOCK EDGE MECHANICAL INTERLOCK TOP FACE SHEET STANDARD 22 GAGE (20 or 18 GAGE OPTIONAL) FORMED STEEL STIFFENERS, POSITIONED NOT MORE THAN 6" APART, AND WELDED TO 22 GAGE LINER (5" O.0 MAX.). 22 GA LINER LOCK PREPA ATION 22 GA STIFFENER HORIZONTAL SECTION THRU VERTICAL STIFFENER I INVERTED (18 GAGE MIN., 14 GA. MAX.) BOTTOM CHANNEL SPOT OR PROJECTION WELDED TO TOP & BOTTOM SKIN FACE SHEETS 18 GAGE CRCO STEEL (STANDARD) 1 22 GA 16 GAGE CRCO STEEL (OPTIONAL) J— LINER GALVANIZED (A40) STEEL (OPTIONAL) OPTIONAL CONTINUOUS. BEAD OF STRUCTURAL 5 8" MIN. D 0 2 9 6 B ADHESIVE APPLIED TO BOTH 1" MAX. VERTICAL SECTION FLANGES OF BOTTOM SKIN THRU BOTTOM OF DOOR Steel -Stiffened Core Door Details CCecoDoor Page 6 of 18 ABLOY Windstorm Door Installation Instructions For Use With FL 4553 HINGE PREPARATION (See Section "E" of R3791\ Volume 1 for Hinge Options) BOTTOM FACE SHEET Glazed Trio/Trio—E INSTRUCTION DETAILS 4 GAGE CLOSER !EINFORCEMENT EQUIRED WITH RIM EXITS POLYURETHANE INSULATION •BETWEEN STIFFENERS DENSITY : 1.8-2.0 LBS/CUBIC FOOT LOCK EDGE IS BEVELED 1/8' IN 2- HINGE EDGE IS PERPENDICULAR TO FACES HINGE BACKSET IS 1/4'. (VARIES PER CONDITION) LOCK EDGE TOP ACE HE (See Section "F"& "G" of R3791 Volume 1 for Lock Options) FACE SHEET FACE SHEETS 18 GAGE CRCQ STEEL (STANDARD) 16 GAGE CRCQ STEEL (OPTIONAL) GALVANIZED (A60) STEEL (OPTIONAL) OPTIONAL INVERTED (16 GAGE MIN., 14 GA. MAX.) TOP CHANNEL SPOT OR PROJECTION WELDED TO TOP & BOTTOM SKIN 18 GAGE CAP CHANNEL IS SCREWED TO INVERTED CHANNEL (OPTIONAL). 22 GA VERTICAL SECTION LINER THRU TOP OF DOOR 16 OR 18 GA (WELDING OPTIONAL) VERTICAL EDGES ARE WELDED THE FULL HEIGHT OF DOOR AND DRESSED SMOOTH TO OBTAIN COMPLETELY SEAMLESS HINGE AND LOCK EDGES. 22 GA -3/4- LINER VERTICAL EDGES ARE CECO'S STANDARD HORIZONTAL SECTION , TAB & SLOT THRU LOCK EDGE MECHANICAL INTERLOCK US BEAD OF STRUCTURAL APPLIED TO BOTH OF BOTTOM SKIN D0323 STANDARD 22 GAGE (20 or 18 GAGE OPTIONAL) FORMED STEEL STIFFENERS, POSITIONED NOT MORE THAN 6' APART, AND WELDED TO 22 GAGE LINER (5- O.0 MAX.). 22 GA LINER 22 GA STIFFENER HORIZONTAL SECTION THRU Trio-E VERTICAL STIFFENER STANDARD 22 GAGE (20 or 18 GAGE OPTIONAL) FORMED STEEL STIFFENERS, POSITIONED NOT MORE THAN 6' APART, AND WELDED TO 22 GAGE LINER (5. O.0 MAX.). �22 GA LINER —22 GA STIFFENER HORIZONTAL SECTION THRU Trio VERTICAL STIFFENER INVERTED (18 GAGE MIN., 14 GA. MAX.) BOTTOM CHANNEL SPOT OR PROJECTION WELDED TO TOP & BOTTOM SKIN 1 22 GA L LINER 5 8- MIN. 1- VERTICAL SECTION THRU BOTTOM OF DOOR d Trio/Trio-E Core Door Details with Rim Exit or Vertical Rod Only) Meco Door Page 7 of 18 HINGE PREPARATION BOTTOM FACE SHEET Windstorm poor Installation Instructions Fdr Use With FL 4553 POLYSTYRENE DOOR CONSTRUCTION DI TAILS 14 GAGE CLOSER REINFO�CEMENT (OPTIONAL) POLYSTYRENE CORE: 1 Ib/ft- LIL LISTED (ASSEMBLE WITH ADHESIVE APPLIED TO BOTH SIDES). LOCK EDGE IS BEVELED 1/8" IN 2" (1:16) SQUARE EDGE OPTIONAL INVERTED (16 GAGE MIN., 14 GA. MAX.) TOP CHANNEL SPOT OR PROJECTION WELDED TO TOP & BOTTOM SKIN 18 GAGE CAP CHANNEL IS SCREWED TO INVERTED CHANNEL (OPTIONAL). CLOSER REINF. 14GA. x 20" LONG (Optionol) VERTICAL SECTION THRU TOP OF DOOR - ---- --------- --'-"- q VERTICAL EDGES ARE CECO'S STANDARD ----------------------- LOCK TAB & SLOT MECHANICAL INTERLOCK -------------------p EDGE --------4----------- WELD SEAMED EDGES GROUND ______q SMOOTH ARE OPTIONAL ------~-----------4 ---_�--------_--_ q 1-3/4" �------------ I I I I ------------ ------------ -�------------ _ _ _ _ _ _ _ _ _ _ OPTIONAL: CENTER EDGE SEAM --- q VERTICAL EDGES ARE CONTINOUSLY WELDED WITH -------- 18GA MINIMUM BACKUP ANGLE FULL HEIGHT OF DOOR AND DRESSED SMOOTH TO OBTAIN SEAMLESS TOP FACE SHEET ----- HINGE & LOCK EDGES ___ q I I I I _ _ 1-3/4" - q I I I I LOC PREPARATION HORIZONTAL SECTION THRU LOCK EDGE D0255 INVERTED (18 GAGE MIN., 14 GA. MAX.) BOTTOM CHANNEL SPOT OR PROJECTION WELDED TO TOP & BOTTOM SKIN 5 8" MIN. 1" MAX. VERTICAL SECTION THRU BOTTOM OF DOOR Polystyrene Core Door Details C=—CecoDoor Page 8 of 18 Windstorm Door Installation Instructions For Use With FL 4553 Honeycomb Core Door CONSTRUCTION DETAILS HINGE PREPARA CLOSER HONEYCOMB CORE BOTTOM FACE SHEET ISHEET TOP F HINGE EDGE LOCK PREPARATION LOCK EDGE IS BEVELED 1/8' IN 2' (1:16) SQUARE EDGE OPTIONAL INVERTED (16 GAGE MIN., 14 GA. MAX.) TOP CHANNEL SPOT OR PROJECTION WELDED TO TOP 4 BOTTOM SKIN 18 GAGE CAP CHANNEL IS SCREWED TO INVERTED CHANNEL (OPTIONAL). CLOSER REINF. 14GA. x 20' LONG (OptionuD VERTICAL SECTION THRU TOP OF DOOR LOCK VERTICAL EDGES ARE CECO'S STANDARD EDGE TAB L SLOT MECHANICAL INTERLOCK WELD SEAMED EDGES GROUND SMOOTH ARE OPTIONAL �4• OPTIONAL, CENTER EDGE SEAM VERTICAL EDGES ARE CONTINOUSLY WELDED WITH 18GA MINIMUM BACKUP ANGLE FULL HEIGHT OF DOOR AND DRESSED SMOOTH TO OBTAIN SEAMLESS HINGE & LOCK EDGES 1-3/4' HORIZONTAL SECTION THRU LOCK EDGE INVERTED (18 GAGE MIN., 14 GA. MAX.) BOTTOM CHANNEL SPOT OR PROJECTION WELDED TO TOP 6 BOTTOM SKIN I - q 5/8' MIN. V MAX. VERTICAL SECTION THRU BOTTOM OF DOOR Honeycomb Core Door Details C—Cewoor Page 9of18 • Windstorm Door Installation Instructions For Use With FL 4553 Polyurethane Foam Core CONSTRUCTION DETAILS HINGE PREPARA BOTTOM FACE SHEET EMBOSSED SKINS OPTIONAL HINGE EDGE D0237B 14 GAGE or POLYURETHANE FOAM CORE LOCK EDGE PREPARATION LOCK EDGE IS BEVELED 1/8' IN 2' 016) SQUARE EDGE OPTIONAL INVERTED (16 GAGE MIN., 14 GA. MAX.) TOP CHANNEL SPOT OR PROJECTION WELDED TO TOP & BOTTOM SKIN 18 GAGE CAP CHANNEL IS SCREWED TO INVERTED CHANNEL (OPTIONAL). CLOSER REINF. 14GA. x 20' LONG (Optional) El VERTICAL SECTION THRU TOP OF DOOR VERTICAL EDGES ARE CECO'S STANDARD TAB & SLOT MECHANICAL INTERLOCK WELD SEAMED EDGES GROUND SMOOTH ARE OPTIONAL 1-3/4' OPTIONAL: CENTER EDGE SEAM VERTICAL EDGES ARE CONTINOUSLY WELDED WITH 18GA.MINIMUM BACKUP ANGLE FULL HEIGHT OF DOOR AND DRESSED SMOOTH TO OBTAIN SEAMLESS HINGE & LOCK EDGES 1-3/4' HORIZONTAL SECTION THRU LOCK EDGE INVERTED (16 GAGE MIN., 14 GA. MAX.) BOTTOM CHANNEL SPOT OR PROJECTION WELDED TO TOP & BOTTOM SKIN 5/8' MIN. 1' MAX. VERTICAL SECTION THRU BOTTOM OF DOOR Polyurethane Core Door Details Meco Door Page 10 of 18 Windstorm Door Installation Instructions Four Use With FL 4553 Mineral Core Door CONSTRUCTION DETAILS HINGE 1 PREPARATION r BOTTOM FACE SHEET HINGE EDGE US GYPSUM FIREDOOR COREBOARD (Assemble With Adhesive Applied To Both Surfaces) LOCK EDGE TOP FACEI SHEET //+�A LOCK PREPARATION D0262B / 1/ LOCK AND HINGE EDGES ARE BEVELED 1/8' IN 2" (1:16) SQUARE EDGE OPTIONAL RECESSED 16 GAGE TOP CHANNEL IS WELDED TO BOTH FACE SHEETS 18 GAGE CAP CHANNEL IS SCREWED TO INVERTED CHANNEL (OPTIONAL). 3/16" T CLOSER REINF. I` 14Gax6"x20" / VERTICAL SECTION THRU TOP OF DOOR STANDARD: CENTER EDGE SEAM VERTICAL EDGES ARE CONTINOUSLY WELDED WITH 18GA MINIMUM BACKUP ANGLE FULL HEIGHT OF DOOR AND DRESSED SMOOTH TO OBTAIN SEAMLESS HINGE & LOCK EDGES M ' 3/4" OPTIONAL: TAB & SLOT MECHANICAL INTERLOCK WELD SEAMED EDGES GROUND SMOOTH ARE OPTIONAL 1-3/4" HORIZONTAL SECTION THRU LOCK EDGE RECESSED 16 GAGE BOTTOM CHANNEL IS SPOT WELDED TO BOTH FACE SHEETS / 3/16, VERTICAL SECTION THRU BOTTOM OF DOOR Mineral Core Door Details Meco Door Page 11 of 18 01 1.500 Windstorm Door Installation Instructions For Use With FL 4553 1 -ies a •V -fJV --1,656" 2 2" .4650" �250' ,187`_ ' 2 GLAZING SHII . AS NEEDED ,3-750" --j �-- 6 2 5° J GLAZING (OPTIONAL) )KGLAZING 1 4' MAKROLON POLYCARBONATE GLASSLAM'SAFETY PLUS 2 S EET BY SHEFFIELD PLASTICS LAMINATED GLASS TYPE 1 VISION LIGHT KIT TYPE 2 VISION LIGHT KIT "SEE LIMITATIONS BELOW 'SEE LIMITATIONS BELOW 5 OPTIONAL PROFILES 22 1/2' 24' MAX MAX --1.65 - {MIN EXPOSED SSD ��MIN EGLASSD 7 6' MIN I I I 6' MIN I I 0.750' min. 3 1/2' NOTE MAX. 66' SURROUND CHANNEL XPOSED MAX. GLASS LENGTH IS EQUAL TO CUT-OUT EXPOSED IN DOOR FOR VISION LIGHT K T. - GLASS MULTIPLE KITS MULTIPLE NOT ALLOWED KITS • GLASSLAM SAFETY PLUS 2---, LAMINATED GLASS MUST BE GLAZED WITH DOW CORNING 995 SILICONE DOW CORNING 995 SILICONE ALLOWED DESIGN LOAD = +/- 60 PSF DESIGN LOAD = +/- 60 PSF IMPACT RATING = 350 FT LBF IMPACT RATING = 350 FT LBF NOT AVAILABLE WITH TRIO OR TRIO-E VISION LIGHT KIT DETAILS NOTES, 1) 1/8 x 1/2 x PERIMETER OF VISION LIGHT KIT CLOSED CELL FOAM TAPE PER VISION LIGHT VISION LIGHT 2) 06 X 1 I/4' OVAL HEAD TEK SCREW - CORNER WELD MAXIMUM SCREW HOLE SPACING IS 9.75' ON CENTER DETAIL 3) GLASSLAM SAFETY PLUS 2 LAMINATED GLASS O O/ ( 4 SPOT WELDS 4) 18 GA. (.043) MIN. TYPE 2 VISION LIGHT KIT AT EACH CORNER ) 5) 14 GA (.068) MIN. PIECES SURROUND CHANNEL PER VISION LIGHT 6) 1/4' MAKROLON POLYCARBONATE SHEET D0254 Applied Glass Kit Details C=—CecoDoor Page 12of18 A%A ABL OY Windstorm Door Installation Instructions For Use With FL 4553 GLAZING SHIMS 1188" AS NEEDED DOW CORNING 995 SILICONE VISION LIGHT Krr DETAILS VISION LIGHT CORNER WELD DETAIL ( 4 SPOT WELDS AT EACH CORNER ) U .625"I 5 GLASSLAM SAFETY PLUS 2 LAMINATED GLASS TYPE 2 VISION LGHT KIT •SEE LIMITATIO S BELOW - 32" MAX 6 XPOSED MIN GLASS 6" MIN I I 42" MAX. EXPOSED GLASS -I AULTIPLE KITS NOT ALLOWED DESIGN LIOAD = +/- 70 PSF IMPACT RATING = 350 FT LBF ID0322 GLASSLAM SAFETY PLUS 2 LAMINATED GLASS MUST BE GLAZED WITH DOW CORNING 995 SILICONE NOTES: 1) 1/8 x 1/2 x PERIMETER OF VISION LIGHT KIT CLOSED CELL FOAM TAPE PER.VISION LIGHT 2) #6 X 1 1/4. OVAL HEAD TEK SCREW - MAXIMUM SCREW HOLE SPACING IS 8.250" ON CENTER AND 3.5' MAX. FROM ENDS 3) GLASSLAM SAFETY PLUS 2 LAMINATED GLASS 4) 18 GA. (.043) MIN. TYPE 2 VISION LIGHT KIT 5) 20 GA (.032) MIN. GAGE SURROUND CHANNEL Applied Glass Kit Details Trio/Trio-E Weco Door Page 13 of 18 A%AABLAY a d" X I" Foam ToF �.625„ Windstorm Door Installation Instructions Foir Use With FL 4553 TYPE "A" 4" h4ax. 2 3/4" D0256 e" X 2„ Foam Tope X h 3" Phil. F.H. K $crew Sp�twelds 3" Max. 500" From End & 12" Mox. 0A Center liwelds J" Max. m End & 8" Max. ZX J" Double Center f Sided Tape (OPTIONAL) NOTES: 1) Glass is 1/4" Makrolon Polycorboncte 2) Multiple kits not allowed 3) N/A Trio/Trio—E or Impericl/Versodoor TYPE "B" 0 8 X 1 J" Phil. F.H. TEK Screw Spotwelds B" Max. From End & 8" Max. On Center 22" MAX 6 EXPOSED MIN GLASS 1 6" MIN I I 33 1/2" MAX. EXPOSED GLASS DESIGN LOAD = +/— 60 PSF IMPACT RATING = 350 FT LBF Flush Welded Glass Kit Details Polycarbonate Glazing Instructions C=—Cec0000r AS MLOY Page 14 of 18 Windstorm Door Installation Instructions Foir Use With FL 4553 Polycakbonate Glazing Instructions TYPE "A" TYPE "B" .375" X .420" �1" X 4" Foam Tape Foam Tope #8 X 1 J" Phil. F.H. #8 X 1 4" Phil. F.H. TEK Screw TEK Screw Spotwelds 3" Max. From End & 12" Max. .500" .500" On Center F11: 3 .750" Spotwelds J" Max. 625" Spotwelds Mo . From End & 8" Max. From End 6 8" Max. X �" Double On Center On Center Sided Tape j (Not Required) 1/8" x 1/2" 2" �25a #6 X 1 j" Oval Head Foam To a TEK Screw GLAZING SHIMS AS NEEDED GLAZING (OPTIONAL) T 1/4" MAKROLON POLYCARBONATE SHEET BY SHEFFIELD PLASTICS 71PE 1 V1S10N LIGNT KIT .3750 1) BEFORE REMOVING THE REMOVA�LE STOPS, CHECK TO BE SURE THERE ARE SCREWS IN EVERY HOLE. IF A SCREW IS MISSING AND THE MATERIAL BELJOW HASN'T BEEN DRILLED, THEN PRE -DRILL HOLES WITH CORRECT BIT FOR THE SCREW SIZE. DO NOT REMOVE STOPS. 2) USING PENCIL, MARK ALIGNMENT MARKS ON THE REMOVABLE STOPS (AND THE DOOR IF TYPE I KIT). 3) UNSCREW THE TEK SCREWS FROM THE REMOVABLE STOPS AND REMOVE THE REMOVABLE STOPS. KEEP THE SCREWS. 4) APPLY 1/8" X 1/2" CLOSED FELL FOAM GLAZING TAPE TO THE FIXED STOP. 5) IF THERE IS PLASTIC RELEASO ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK ABOUT 2" FROM EACH END OF THE FOAM TAPE. FULL THE PLASTIC RELEASE ABOVE THE FIXED STOP SO IT CAN BE GRASPED AFTER PLACING THE POLYCARBOI JE 0 THE UNEXPOSED FOAM TAPE. 6) IF THERE IS PAPER RELEASE ON THE FOAM GLAZING TAPE, REMOVE THE PAPER RELEASE BEFORE GLAZING. SPRAY THE EXPOSED FOAM TAPE WITH A MILD SOAP SOLUTION IMMEDIATELY BEFORE PLACING THE POLYCARBONATE ON THE EXPOSED FOAM TAPE. 7) PLACE GLAZING SHIMS, AS NEEDED, THEN SET THE POLYCARBONATE ON THE FOAM GLAZING TAPE. 8) ADJUST THE POLYCARBONATE, AS NECESSARY, TO CENTER THE POLYCARBONATE IN THE CUTOUT. 9) IF THE RELEASE IS PLASTCd, GRASP THE FREE END OF THE PLASTIC RELEASE, WHILE HOLDING THE POLYCARBONATE TO KEEP IT FROM MOVING. TI EN SLOWLY PULL THE PLASTIC RELEASE OFF OF THE FOAM TAPE THAT WAS APPLIED TO THE FIXED STOP. I 10) APPLY 1/8" X 1/2" CLO�SED CELL FOAM TAPE TO THE REMOVABLE STOP. 11) IF THERE IS A PLASTIC RELEASE ON THE FOAM GLAZING TAPE, PULL THE RELEASE BACK ABOUT 2" FROM EACH END OF.THE FOAM TAPE. PU�L THE PLASTIC RELEASE ABOVE THE REMOVABLE STOP SO IT CAN BE GRASPED AFTER PLACING THE REMOVABLE STOP ON THE POLYCARBONATE. 12) IF THERE IS PAPER RELEASE ON THE FOAM GLAZING TAPE, REMOVE THE PAPER. SPRAY THE EXPOSED FOAM TAPE WITH A MILD SOAP SOLUTION IMMEDIATELY BEFORE PLACING THE REMOVABLE STOPS AGAINST THE POLYCARBONATE. 13) USING THE ALIGNMENT I ARKS, POSITION THE REMOVABLE STOPS AGAINST THE POLYCARBONATE. 14) INSTALL AND TIGHTEN THE TEK SCREWS IN THE REMOVABLE STOPS. BE CAREFUL NOT TO OVER TIGHTEN. 15) IF THE RELEASE IS PL(STIC, GRASP THE FREE END OF THE PLASTIC RELEASE, AND SLOWLY PULL THE PLASTIC RELEASE OFF THE FOAM TAPE THAT WAS APPLIED TO THE REMOVABLE STOP. 16) USING DOW CORNING 995 SILICONE OR OTHER HIGH QUALITY SILICONE, APPLY A CAP BEAD OVER THE CLOSED CELL FOAM TAPE ON THE JEXTERIOR SIDE OF THE DOOR VISION LIGHT KIT. (Conversion: 1" = 25.4 mm, e.g., 1-3/4" = 44.45 mm) Meco Door F-11�. s � : • 9-125 09/27/17 Page 15 of 18 Windstorm boor Installation Instructions Fo, Use With FL 4553 . TYPE "C" D0258 TYPE "D" X .625" 1" X �" .625" Foam Tape Foam Tape X 1 a" Phil. F.H. #8 X 1 J" Phil. F.H. EK Screw I 1 TEK Screw Dow Corning .500" Dow Corning 625" .500" 995 Silicone � 995 Silicone .750" Spotwelds J" Max. Spotwelds �" Max. From End & 8" Max. From End & 4" Max. 33 X J" Double On Center On Center i Sided Tape (OPTIONAL) Spotwelds 3" Max. From End & 12". Max. On Center NOTES: 1) Glass is Glasslam Safety Plus 11 2) Multiple kits allowed 22" 3) NA Trio/Trio—E or Imperial/Versodoor 6„ MAX MIN EXSS POSED GLA g" IT I I o — 66" MAX. 4" Max. EXPOSED GLASS � o 2 3/4" tJax. — i DESIGN LOAD = +/— 60 PSF IMPACT RATING = 350 FT LBF Alternate Flush Welded Glass Kit Details Weco Door Page 16 of 18 A%A ABWY Windstorm P Glasslam TYPE "C" a" X " —.625" Foam Tape #8 X 1 a" TEK Screw -� Dow Corr .500" 995 Silit Spat I .750"' 1 Fror Installation Instructions Use.With FL 4553 S I fety Plus II Glazing Instructions TYPE "D" Xi" hil. F.H. Fcom Tope me ." me 625"500 "I L Ids J" Max. End & 8° Max. " X d Doubid Spo welds 3" Mox. Sided Tape Fro End & 12' Mox. (Not Required L'T O. Center PET Flop Required— J..I I X 2" �I H6 X 1-}" Oval Screw Foam Toped •465D' I I I Head TEK Screw Spotwelds 3' Max. From End & 12 Mox. On Center Dow CORNING 995 SILICONE aal.7 N^ GLASSLAM SAFETY PLUS 2 LAMINATED GLASS PET Flop Required 6250- TYPE2WSIONLIGHTIOT ' PET Flap Required PET Flop .625" #8 X 1 1" Phil. F.H. TEK Screw Dow Corning 995 Silicone Spotwelds 8" Max. From End & 4" Max. On Center 1) BEFORE REMOVING THE REMOVABLE/ STOPS, CHECK TO BE SURE THERE ARE SCREWS IN EVERY HOLE. IF A SCREW IS MISSING AND THE MATERIAL BELOW HASN'T BEEN DPILLED, THEN PRE -DRILL HOLES WITH CORRECT BIT FOR SCREW SIZE. DO NOT REMOVE STOPS. 2) USING A PENCIL, MARK ALIGNMEN MARKS ON THE REMOVABLE STOPS (AND THE DOOR IF TYPE 2 KIT). 3) UNSCREW THE TEK SCREWS FRO4 THE REMOVABLE STOPS AND REMOVE THE REMOVABLE STOPS. KEEP THE SCREWS. 4) APPLY 1/8" X 1/2" CLOSED CE L FOAM GLAZING TAPE TO THE FIXED STOP. 5) IF THERE IS PLASTIC RELEASE ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK ABOUT 2" FROM EACH END OF THE FOAM TAPE. PULL THE PLASTIC REL�SE ABOVE THE FIXED STOP SO IT CAN BE GRASPED AFTER PLACING THE GLASSLAM ON THE UNEXPOSED FOAM TAPE. 6) IF THERE IS PAPER RELEASE O� THE FOAM GLAZING TAPE, REMOVE THE PAPER RELEASE BEFORE GLAZING. SPRAY THE EXPOSED FOAM TAPE WITH A MILD SOAP SOLUTION IMMEDIATELY BEFORE PLACING THE GLASSLAM ON THE EXPOSED FOAM TAPE. 7) PLACE GLAZING SHIMS, AS NEEDED, THEN SET THE GLASSLAM ON THE FOAM GLAZING TAPE. 8) ADJUST THE GLASSLAM, AS N�CESSARYI TO CENTER THE ASSEMBLY IN THE CUTOUT. 9) IF THE RELEASE IS PLASTIC, RASP THE FREE END OF THE PLASTIC RELEASE, WHILE HOLDING THE GLASSLAM TO KEEP IT FROM MOVING. THEN SLOWLY PULL TH PLASTIC RELEASE OFF OF THE FOAM TAPE THAT WAS APPLIED TO THE FIXED STOP. 10) TRIM THE PET FLAP SO IT 60ES NOT EXTEND BEYOND THE REMOVABLE GLASS STOP. 11) TAKE A PUTTY KNIFE AND INISERT IT BENEEN THE PET FLAP AND THE EDGE OF THE CUTOUT IN THE DOOR. USING THE PUTTY KNIFE PULL THE PET FLAP AWq FROM THE CUTOUT IN THE DOOR. 12) WHILE HOLDING THE PET FLAP BACK AWAY FRO44 THE CUTOUT WITH THE PUTTY KNIFE, USE A CAULKING GUN TO APPLY DOW CORNING 995 SILICONE 9ETWEEN THE PET FLAP AND THE STEEL IN THE CUTOUT OF THE DOOR. IMPORTANT: ENSURE THAT THE DOW CORNING 995 SILICONE FULLY WETS OUT OR COVERS THE PET FLAP AND COMES IN CONTACT WITH THE STEEL AROUND THE CUTOUT IN THE DOOR. 13) SLOWLY MOVE THE PUTT, KNIFE AROUND THE DOOR AHEAD OF THE CAULKING GUN AND APPLY THE 995 SILICONE AROUND THE ENTIRE CUTOUT IN THE DOOR. 14) APPLY 1/8" X 1/2" CL SED CELL FOA14 GLAZING TAPE TO THE REMOVABLE STOP. 15) IF THERE IS A PLASTIC RELEASE, ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK ABOUT 2" FROM EACH END OF THE FOAM TAPE. PULL THE PLASTIC ON ABOVE THE REMOVABLE STOP SO IT CAN BE GRASPED AFTER PLACING THE REMOVABLE STOP ON THE GLASSLAM. 16) IF THERE IS PAPER RELEASE ON THE FOAM GLAZING TAPE, REMOVE THE PAPER. SPRAY THE EXPOSED FOAM TAPE WITH A MILD SOAP SOLUTION IMMEDIAATELY BEFORE PLACING THE REMOVABLE STOPS AGAINST THE GLASSLAM. 17) USING THE ALIGNMENI�MARKS, POSITION THE REMOVABLE STOPS AGAINST THE GLASSLAM. 18) INSTALL AND TIGHTENII THE TEK SCREWS IN THE REMOVABLE STOPS. BE CAREFUL NOT TO OVER TIGHTEN. 19) IF THE RELEASE IS PLASTIC, GRASP THE FREE END OF THE PLASTIC RELEASE, AND SLOWLY PULL THE PLASTIC RELEASE OFF THE FOAM TAPE THAT WAS APPLIED TO THE REMOVABLE STOP. 20) USING THE DOW COffPNING 995 SILICONE OR OTHER HIGH QUALITY SILICONE, APPLY A CAP BEAD OVER THE CLOSED CELL FOAM TAPE ON THE EXTERIORISIDE OF THE DOOR VISION LITE KIT.' 9-126 I(Conversion: 1" = 25.4 mm. e.g., 1-3/4" = 44.45 mm) 09/27/17 C=-CecoDoor Page 17 of 18 ASM ABLOY Windstorm Door Installation Instructions For Use With FL 4553 6 6 6 LOUVE INSTALLATION NOTES- 1. DESIGN PRESSURE - 70 PSF MAX. (OUTSWING ONLY). 2. MARKAR WLV60 LOUVER WITH SECURITY GRILLE SHOWN. SECURITY 3. ANY LISTED LOUVER MAY BE USED. GRILLE 4. MAXIMUM LOUVER SIZE IS 34' X 78'. 5. 6' MINIMUM STILES AND RAILS. 6. MULTIPLE LOUVERS ALLOWED PER DOOR EXTERIOR INTERIOR 7. NOT AVAILABLE WITH TRIO OR TRIO-E 1.656• 750 I \ OPTIONAL END CHANNEL / SURROUND PROFILES F9-f 625'_ 1.500' L 18 GA. MIN. SURROUND CHANNEL D0274 Louver Details Weco Door Page 18of18 AMA ABIAY