Loading...
HomeMy WebLinkAboutNOASCAMW BY St LudeCnitnt/ MWAM DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) RECEIVED FT Synthetics, Inc. 12179-86"Avenue I MAY 3 12018 Surey BC CANADA V3W 3118 ST. Lucie County, PCPs^ I•IIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 7 www.miamidade.gov/economy SCOPE: This NOA is being. issued under the applicable rules ana regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). i This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas otherithan Miami -Dade County) reserve the right .to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend -the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roofing Underlayment LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.14-1202.05 and consists of pages 1 through 4. CONCEALED FASTENERS OR ATi ACHMENTS The submitted documentation was reviewed by Gaspar J Rodriguez. ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD ( NOA No.: 16-0510.30 ST. LUCIE COUNTY BUILDING REVIEWED FOR COMPLIANCE; E PLANS AND ALL PROPOSED WORK 3LIBMECT TO ANY CORRECTIONS TIRED BY FIELD INSPECTORS THAT Page 1 of 4 R TO BE Y WITH ALL APPLICABLE ODES. PLANS AND PER IT MUST BE KEPT ON JOB SITE OR NO INSPECTIONS) WILL BE MADE FILE -COPY ROOFING COMPONENT APPROVAL Category: Roofing Sub-Categorv: Underlayment Material: Polypropylene SCOPE: This approves FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments, as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description _F_T"Syntheties:Silver 48"-x 250' rolls ASTM D226 Type Woven synthetic polymer underlayment-with.-two 06 lbs. per roll �- 18c sides coated with UV protected and slip -resistant 1 polymer -stabilized polypropylene on both sides. FT Synthetics Gold 48" x 250' rolls ASTM D226 Type Woven synthetic polymer underlayment with two 32 lbs. per roll I &III sides coated with UV protected and slip resistant I polymer stabilized polypropylene on both sides. FT Synthetics Platinum 48" x 250' rolls ASTM D226 Type Woven synthetic polymer underlayment with two 35 lbs. per roll I & III sides coated with UV protected and slip resistant I polymer stabilized polypropylene on both sides. MANUFACTURING LOCATION: 1. Qindao, China EVIDENCE SUBMITTED: Test Agency Intertek Testing Services Test Identifier i 101866009COQ-002A 101866009COQ I'T001 Test Name/Report Physical Properties ASTM D 226 Date 11/19/14 11/17/14 NOA No.: 16-0510.30 Page 2 of 4 I ' I I INSTALLATION SPECIFICATIONS: (Single Layer: Slopes of 2:12 or greater) FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayment I. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall be installed in strict compliance with applicable Building Code. 2. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall be installed with a minimum 4-inch horizontal -lap and 64nch vertical laps in a shingle layer fashion. Vertical laps in a succeeding course shall be staggered from those in preceding course by minimum 6-feet. 3. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall be fastened with approved roofing nails and tin -caps spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll. 4. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments may be used with Asphaltic shingles, Wood shakes and shingles, Non-structural metal roofing, and quarry slate. 5. For fire classification of specific roof assemblies using FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments refer to a current Approved Roofing Materials Directory for fire ratings of this product. I BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied 1. This Notice of Acceptance. 2. Any other document's required by the Buil evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance; fire ratings of this product. of the following: Official or applicable building code in order to properly to a current Approved Roofing Materials Directory for 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building bode. 3, FT Synthetics Silver, FT Synthetics Gold, FT Sy Ithetics Platinum Roof. Underlayments shall be applied to a smooth,. clean and dry surface with deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. -4. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall not be hot mopped, refer to manufacturer's published literature for product compatibility. 5. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall not be applied over an existing roof membrane as a recover system. 6, FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall not be left exposed as a temporary roof for longer than 30 days of application. 7. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments are components used in roof system assemblies. Roof system assemblies are approved under a specific Notice of Acceptance. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. NOA No.: 16-0510.30 Page 3 of 4 $, FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments may be used with any approved roof covering Notice of Acceptance listing FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments as a component part of an assembly in the Notice of Acceptance. If FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments are not listed, a request may be made to the Authority Having Jurisdiction'(AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing�results. 9. All products listed herein shall have a quality as audit in accordance with the Florida Building Code and Rule'61G20-3 of the Florida Administrative I Code. 10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city; state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE i i NOA No.: 16-0510.30 Page 4 of 4 MIAMI•DAD DEPARTMENT OF REGULATORY AND ECONOMIC BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA GAF 1 Campus. Drive Parsipanny, NJ 07054 MIAMI-:DADE COUNTY PRODUCT CONTROL SECTION JRCES (RER) 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.sov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). I This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes,. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such1testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the. right to revoke this acceptance, if it is determined by Miami -Dade County Product Cont of Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Leak Barriers and Roof Deck Protection LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal o`f NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA 16-1213.04 and consists of pages 1 through 10. The submitted documentation was reviewed by Hamley Pacheco, P.E. MIAMI-DADS COUNTY NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 1 of 10 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS/Polypropylene/Asphalt PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description WeatherWatch® Mineral 36" x 50' rolls ASTMiD 1970 Granular surfaced modified, fiberglass reinforced, Surfaced Leak Barrier 36" x 66.7' rolls bituminous sheet material for use as a leak barrier Manufacturing underlayment in sloped roof assemblies. Location #1, 9 Designed as an ice & rain shield. Film = 36" x 66.7' rolls ASTM D-1970 C1Vlodified, fiberglass reinforced, bituminous sheet �StormGaardo Surface'd_L-eak-Barrier _ 'material' for use as a high temperature leak -barrier Manufacturing} underlayment in sloped roof assemblies. Location #1;t9 i -Designed as an ice & rain shield. LibertyTm SBS Self- 39 3/8" x 66' rolls AST1V� D 1970 Self -adhering SBS roof membrane. Adhering Base/Ply Sheet ASTM D4601 Manufacturing Type II Location #1, 9 Deck-ArmorT' Premium 54" x 222' rolls i ASTM D 226 A UV -stabilized polypropylene breathable Breathable Roof Deck 48" x 100' rolls Type II underlayment. To be used for roof deck Protection protection as an underlayment in sloped roof Manufacturing assemblies. Location #2 Tiger Paw" Roof Deck 48" x 250' rolls ASTM D 226 A UV -stabilized polypropylene non -breathable Protection 48" x 100' rolls Type II underlayment. To be used for roof deck protection Manufacturing as an underlayment in sloped roof assemblies. Location #3, 5, 6 FeltBuster® High -Traction 48" x 250' rolls ASTM D 226 A UV -stabilized polypropylene non -breathable Synthetic Roofing Felt Type I underlayment. To be used for roof deck protection Manufacturing as an underlayment in sloped roof assemblies. Location #7, 8 Shingle -Mate® Roof Deck 36" x 144' rolls ASTM D 226 Fibergass-reinforced asphalt felt underlayment. To Protection Type I be used for roof deck protection as an Manufacturing underlayment in sloped roof assemblies. Location #4 NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 2 of 10 PRODUCTS DESCRIPTION: (Test Product Product Dimensions Specification Description LibertyTM SA Glass Cap 39 3/s" x 34' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Sheet ASTM P 6163 self -adhering SBS roof membrane. Manufacturing ASTM D 7530 Location # 9 1 GAFGLAS® Ply 4 39.37" ASTM 4 D2178 Aspahalt impregnated glass felt with aspahlt Manufacturing (1 meter) Wide Type IV coating. Location # 9, 10 GAFGLAS® FlexPIyTI' 6 39.37" ASTM D2178 Aspahalt impregnated glass felt with aspahlt Manufacturing (1 meter) Wide Type VI coating. Location # 9, 10 MANUFACTURING LOCATION: 1.Mt. Vernon, IN 2.North Bay, Ontario 3.Mission, British Columbia 4.Pryor, OK S.Qingdao, China 6.Charleston, SC 7.Spartanburg, SC 8.Dadra, India 9.Savannah, GA IO.Mobile, AL I NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 3 of 10 i EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Intertek Testing Services NA Ltd. 3077464-101 ASTM D 1970 08/23/06 3090131 Wind Uplift and Self Seal ability 08/23/06 100258583CO9-010A ASTM D 226 Type II 01/08/11 100673818COQ-003 ASTM D 226 Type II 06/13/13 10157289000Q-005 ASTM D 226 Type II 04/17/14 F8549.02-106-18 ASTM D 226 Type I 11/08/16 PRI Construction Materials RGM-023-02-01 ASTM D 4798 05/16/07 Technologies, LLC. GAF-112-02-01 ASTM D 226 Type II 03/15/06 GAF-238-02-01 ASTM D 1970 03/03/10 GAF-323-02-01 ASTM D 1970 11/30/11 GAF-324-02-01 ASTM D 1970 12/01/11 GAF-325-02i O1 ASTM D 1970 12/01/11 GAF-326-02'-O1 ASTM D 1970 11/30/11 GAF-275-02-01 ASTM D 1970 11/11/10 GAF-344-02i01 ASTM D 1970 04/23/12 GAF-339-021,01 ASTM D 226 Type I 03/14/12 ELK-311-02',O1 ASTM D 1970 09/11/07 GAF-518-02 ',O 1 ASTM D 226 Type 1 06/04/14 GAF-818-02 0I ASTM D 4533 12/06/17 GAF-829-02-01 ASTM D 226 Type II 01/15/18 GAF-314-02-61 ASTM D 2178 07/21/11 GAF-315-02-61 ASTM D 2178 07/21/11 Trinity-ERD GAF-SC13285.03.17-1 ASTM D 1970 03/08/17 GAF-SC13285.03.17-3 ASTM D 1970 03/01/17 GAF-SC13285.03,.17-4 ASTM D 1970 03/01/17 GAF-SC13285.02,.17-2 ASTM D 4601 Type II 02/08/17 GAF-SC9700.08-15-RI ASTM D 2178 09/09/15 GAF-SC12915.12.17-RI ASTM D 1970 12/11/17 GAF-SC12915.12.17-RI ASTM D 6163 12/11/17 GAF-SC12915.12.17-RI ASTM D 7530 12/11/17 NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 4 of 10 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 19/32" or greater plywood or wood plank System E (1): Anchor sheet mechanically fastehed to deck, membrane adhered. Base Sheet: Two plies of ASTM D 226 Type�I or Shingle -Mate® Roof Deck Protection OR one or more plies of ASTM D 226 Type II, Deck-ArmoJm Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing,. Felt, or Tiger PawTM Roof Deck Protection with a minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's installation instructions). AlwaysI, apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. i Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTml SA Glass Cap Sheet, or LibertyTm SBS Self -Adhering Base/Ply Sheet membrane with a'minimturi 3" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with WeatherWatch® Mineral Surfaced Leak Barrier, or StormGuard® Film Surfaced Leak Barrier is acceptable. Surfacing: Approved Roofing Assembly. I M �.R®� NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 5 of 10 Deck Type 1: Wood, non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Membrane mechanically fastened to deck. Separator Sheet: One or more plies of GAFGLAS® Ply 4, GAFGLAS®F1exPlyTm 6, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High - Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection loose laid. Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM,SA Glass Cap Sheet, or LibertyTM SBS Self -Adhering Base/Ply Sheet membrane mechanically fastened with a minimuin 3" side lap and a 6" end lap to deck through the separator sheet with approved nails and tin caps 6" o:c. at the laps and two staggered rows 12" o.c. in the field of the roll. Surfacing: Approved Roofing Assembly. CMAMMMECOM —B 4 1 NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 6 of 10 Deck Type 1: Wood, non -insulated 1. Deck Description: 19/32" or greater plywood or wood plank System E (3): Anchor sheet mechanically fastened to deck, membrane adhered. Secondary Water Install a minimum 4" wide WeatherWatch® Mineral Surfaced Leak Barrier, , LibertyTM SBS Barrier: Self -Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, or StormGuard® Film Surfaced (Optional) Leak Barrier membrane over the joints of the plywood roof deck prior to installation of the base sheet. Do not overlap end or side joints. All side and end laps should be butted firmly side by side, flush with each other but not overlapped. Do not leave the WeatherWatch® Mineral Surfaced Leak Barrier, or StormGIuard® Film Surfaced Leak Barrier membrane exposed for more than 30 days without a roof deck protection underlayment protecting the secondary water barrier. Base Sheet: Two plies of ASTM D 226 Type I for Shingle -Mate' Roof Deck Protection OR one or more plies of ASTM D 226 Type I1, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection with a minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four�lstaggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape (follow the tape manufacturer's installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fasteners. Surfacing: Approved Roofing Assembly. NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 7 of 10 Deck Type 1: Wood, non -insulated Deck Description: 19/32" or greater plywood or wood' plank System E (4): Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: Two plies of ASTM D 226 Type I� or Shingle -Mate® Roof Deck Protection OR one or more plies of ASTM D 226 Type II, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection with a minimurn 4" side lap and a 6" end jap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four, staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. Membrane: One or more plies of StormGuardo Film Surfaced Leak Barrier membrane with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. i Surfacing: Approved for Metal roofing, Slate, and Asphalt Shingle assemblies. I NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 8 of 10 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, Liberty'r1*1 SBS Self - Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck -Armor m Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall not be used as roof tile underlayment. 3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, Liberty"mt SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck -Armor' Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall be installed in strict compliance with applicable Building Code. 4. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self - Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection membranes shall be applied'', to a smooth, clean and dry surface with deck free of irregularities. 5. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self - Adhering Base/Ply Sheet, Liberty"rm SA Glass Cap Sheet, Shingle -Mateo Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection membranes shall not be applied over an existing roof membrane. 6. WeatherWatch® Mineral Surfaced Leak' Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self - Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster®' High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. 7. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self - Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, LibertyT" SA Glass Cap Sheet, Shingle -Mateo Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection as a component part of an assembly in the Notice of Acceptance. If WeatherWatch® Mineral Surfaced Leak Barrier, StormGuardo Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt and Tiger PawTM Roof Deck Protection are not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 8. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45' F and rising. 9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. NOA No.: 18-0119.15 MIAMI-MDE COUNTY Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 9 of 10 LIMITATIONS: 10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 11. Flash vent pipes, stacks, chimneys and penetration's in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Coder 12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE NOA No.: 18-0119.15 MIAWDAD�Fgurt' COUNTY ynlj Expiration Date:02/22/23 -0119.15 Approval Date: 02/22/18 Page 10 of 10 CREEK TECHNICAL SERVICES,. LLC EVALUATION REPORT Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE, 6Te EDITION (2017) Manufacturer: DREXEL METALS, INC. Issued September 14, 2017 1234 Gardiner Lane Louisville, KY 40213 (502) 716-7143 ' www.drexmet.com Manufacturing: Drexel Metals Associl tion of Regional Manufacturers (DM -ARM) Quality Assurance: Architectural Testing, Inc. (QUA1844) SCOPE RECEIVED Category: Roofing MAY 31 2018 Subcategory: Metal Roofing Code Sections: 1504.3 ST. Lucie County, Permitting Properties: Wind Resistance REFERENCES Entit Report No. Standard Year Architectural Testing (TST1558) 56840.02-122-18 TAS 100 1995 Architectural Testing (TST1558) 58389.01-122-44 UL 580 2006 Architectural Testing (TST1558) 58459.01-122-44 UL 580 2006 Architectural Testing (TST1558) 58461.01-122-44 TAS 125 2003 Architectural Testing (TST1558) 8I 776.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing (TST1558) 82784.01-109-44 UL 580 2006 ' UL 1897 2012 Architectural Testing (TST1558) 83296.01-109-44 UL 580 2006 UL 1897 2012 Force Engineering & Testing (TST5328) 178-0054T-12 UL 580 2006 UL 1897 2012 Force Engineering & Testing (TST5328) 178-0055T-12 UL 580 2006 UL 1897 2012 Hurricane Test Laboratory (TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0311-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0313-07 TAS 125 2003 Hurricane Test Laboratory (fST1527) 0287-0512-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0706-07 TAS 125 2003 PRI Construction Materials Technologies (TST5878) VLS-005-02-01 ASTM B 117 2016 TAS110 2000 PRI Construction Materials Technologies (TST5878) VLS-004-02-01 ASTM G 155 2005a TAS110 2000 PRI Construction Materials Technologies (TST5878) DMC-004-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) DMC-005-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) DMC-006-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) DMC-007-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-008-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-009702-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-014-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) DMC-016-02-01 TAS 100 1995 PRIConstruction Materials Technologies (TST5878) DMC-017-02-01 Rev 1 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies (TST5878) DMC-018-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies (TST5878) DMC-024-02-01 UL 580 2006 UL 1897 2012 DRX15001.4 FL17678-R4 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality 'assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC l Entitv Report No. Standard Year PRI Construction Materials Technologies (TST5878) DM-033-02-01.1 UL 580 2006 UL1897 2012 PRI Construction Materials Technologies (TST5878) DMC-037-02-01 UL 580 2006 UL1897 2012 PRI Construction Materials Technologies (TST5878) DM137-02-02 UL 580 2006 UL1897 2012 PRI Construction Materials Technologies (TST5878) DMC-038-02-01 UL 580 2006 UL 1897 2012 PRODUCT DESCRIPTION 01VIC100NS" + Profile: tr" ; �`1:iii: snap lock seam- Max.16 in. coverage =:' :. - .._..._ .._ _ _ .. _ .. _.... Description _Non-structural, snap lock standing seam roof panel with integral perorated nail '� strap Material: ; Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or , -ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 i ....................................... i II 5 1" o.C. i DMC 150SL Profile: 1.5 in. snap lock seam; Maxl 16 in. coverage ................ ....... .I— ............. ... r----------------------- - ................ Description Non-structural, snap lock standing seam roof panel ................. :_ . g . _..._............ ............. Material: ; Min. 24 a. Fluro on® coated ASTM A792 AZ50, or ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 _,..._......:....................._....._......._...................................__...__.........._..._._...._....._..--------•-•-------•-----........................_........_._.. T 12 I DMC 15OSS Profile: 1.5 in. mechanical seam; Max_ 1.6 in. coverage -_.---.._.._............ ..................................... Description: ; Non-structural, mechanical lock standing seam roof panel ! Material: j Min. 0.032 in. Fluropon® coated 'ASTM B209 aluminum; Fy = min. 16 ksi; Shall conform with FBC Section 1507.4.3 .........._ ............... ._.........................:........... Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; Fy = min: 50 ksi: Shall conform with FBC Section 1507.4.3 ............ .... .............. . 2 3" B 9 12 1is I-- ------- 16" --- -- I DRX15001.4 FL17678-R4 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. a I CREEK TECHNICAL SERVICES, LLC I DMC 175S Profile: 1:75 in. snap lock sear ........._ _ Description: Non-structural, snap lc Material: ; Min. 0.032 in. Fluropor conform with FBC See Min. 0.040-inch Flurop I conform with FBC Sec ................ Min. 24 ga. Fluropon® ASTM A653 G90; Fy = DREXEL METALS, INC. Metal Roofing n; Max __18 In. coverage ....... ....... .. _ _.......------- .............................. ck standing seam roof panel ................_................................... _.._ ..._. .... . . I R coated ASTM B209 aluminum; Fy = min. 16 ksi; Shall tion 1507.4.3 on® coated ASTM B209 aluminum (Fy = min. 20 ksi); Shall tion 1507.4.3 (coated ASTM A792 AZ50, or min. 50 ksi; Shall conform with FBC Section 1507.4.3 -I— I I 1 a' I i I 16" DMC 200S Profile: 2 in. mechanical seam; Max. 16 in. coverage .........................---------------------------.-..__............- --._.-----._--...._.._._..-------------------------- Description: Non-structural, mechanical lock standing seam roof panel f....._. _._.. ....... Material: Min. 0.040 In. Fluropon® coated ASTM 6209 aluminum; Fy = min. 20 ksi; Shall ' conform with FBC Section "1507.4.3 1................_...._..._...------------._..._...__ -- ... ...--------- ......... ........................... Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; F = min.'50 ksi; Shall conform with FBC Section 1507.4.3 ...............L...-.........._......._..._..............................:....................................-.._..._...................._......................__...................._....._ ................, ........... r 13. s,. I I --I 16 B r 1,..r 2 2" 2" _J 16"-- DMC 450 Profile: 1.5 in. snap lock seam; Max. 16 in. coverage Description, `, Non-structural, snap lock _ __.__-_.__ ..._---.--o p . p .. standing seam_ roof .panel with concealed clip Material: 1 Min. 24 ga. ASTM A792 or ASTM A653; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 . .... _ ..__....... ..... ....................... .........---------- .__...._.__---- ............ ... -......... -- .. Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 24 ksi; Shall 1 conform with FBC Section 1507.4.3 r 1 z" I i �— -- - - 16"------- — _� DRX15001.4 FL17678-R4 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. C R C E K DREXEL METALS, INC. G (� Metal Roofing TECHNICAL SERVICES, LLC DMC 5V Profile: j 3/8 in. ribs; 24 in. coverage I Description: Non-structural, through fastened roof panel Material: Min. 26 ga. FluroponO coated ASTM A792 or ASTM A653 G90 ; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 I - i - 1 24" Coverage - _ .. .. .... ..... 9, 119. _ 16 1116 , ' 3„ 8 DMC Profile: 1/2 in, corrugation; 21 in..,coverage _._. .... Corrugated i Description: ... _...------------........ ......... I Non-structural, through fastened roof panel ._ ...... . _ . . Material: Min. 26 ga. Fluropon@ coated ASTM A792 or ASTM A653 G90 ; Fy = min. 40 ksi; ? Shall conform with FBC- Section...1507.4.3 - -- - Mln 0 032 In Fluropon� coated ASTM 6209 aluminum; Fy =min. 19 ksi; Shall conform with FBC Section �1507 4 3 I _ _.__.._-....... - .. ......_ . ._........ r, i I I ir.....L. - ....... I LIMITATIONS I I 1. Fire classification is not within the scope of this evaluatidln. 2. This report is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be in accordance with FBC Section 1511. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. I DRX15001.4 FL17678-R4 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT DREXEL METALS, INC. Metal Roofing The products evaluated herein by Zachary R. Priest, lIP.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.' ``, %tj%t1 a t����i��i �G�p FtY .... •,,��'ENs".�s�'- 2017.09.14 No 74021 / 1 6:34:1 J 0'. STATE OF :��/"—041001 --�'��•�4 O R O P'���` Zachary R. Priest, P.E. RegistrationFlorida 21 �1 A` i Organization No.A E9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. i CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. i Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. i Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A —installation (11 pages) I 2) APPENDIX B — Approved Roof Systems (7 pages) 3) APPENDIX C — Design Wind Loads(4 pages) DRX15001.4 FL17678-R4 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.