SCOPE:
This NOA is being. issued under the applicable rules ana regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
i
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas otherithan Miami -Dade County) reserve the right .to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend -the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roofing Underlayment
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.14-1202.05 and consists of pages 1 through 4. CONCEALED FASTENERS OR ATi ACHMENTS
The submitted documentation was reviewed by Gaspar J Rodriguez. ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
( NOA No.: 16-0510.30
ST. LUCIE COUNTY BUILDING
REVIEWED FOR COMPLIANCE;
E PLANS AND ALL PROPOSED WORK
3LIBMECT TO ANY CORRECTIONS
TIRED BY FIELD INSPECTORS THAT Page 1 of 4
R TO
BE Y WITH
ALL APPLICABLE ODES.
PLANS AND PER IT MUST BE KEPT ON JOB
SITE OR NO INSPECTIONS) WILL BE MADE
FILE -COPY
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Categorv: Underlayment
Material: Polypropylene
SCOPE:
This approves FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments, as
described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High
Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test
Product
Product
Dimensions
Specification
Description
_F_T"Syntheties:Silver
48"-x 250' rolls
ASTM D226 Type
Woven synthetic polymer underlayment-with.-two
06 lbs. per roll
�- 18c
sides coated with UV protected and slip -resistant
1
polymer -stabilized polypropylene on both sides.
FT Synthetics Gold
48" x 250' rolls
ASTM D226 Type
Woven synthetic polymer underlayment with two
32 lbs. per roll
I &III
sides coated with UV protected and slip resistant
I
polymer stabilized polypropylene on both sides.
FT Synthetics Platinum
48" x 250' rolls
ASTM D226 Type
Woven synthetic polymer underlayment with two
35 lbs. per roll
I & III
sides coated with UV protected and slip resistant
I
polymer stabilized polypropylene on both sides.
MANUFACTURING LOCATION:
1. Qindao, China
EVIDENCE SUBMITTED:
Test Agency
Intertek Testing Services
Test Identifier
i
101866009COQ-002A
101866009COQ I'T001
Test Name/Report
Physical Properties
ASTM D 226
Date
11/19/14
11/17/14
NOA No.: 16-0510.30
Page 2 of 4
I '
I
I
INSTALLATION SPECIFICATIONS: (Single Layer: Slopes of 2:12 or greater)
FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayment
I. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall be installed in
strict compliance with applicable Building Code.
2. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall be installed with
a minimum 4-inch horizontal -lap and 64nch vertical laps in a shingle layer fashion. Vertical laps in a
succeeding course shall be staggered from those in preceding course by minimum 6-feet.
3. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall be fastened with
approved roofing nails and tin -caps spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the
field of the roll.
4. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments may be used with
Asphaltic shingles, Wood shakes and shingles, Non-structural metal roofing, and quarry slate.
5. For fire classification of specific roof assemblies using FT Synthetics Silver, FT Synthetics Gold, FT
Synthetics Platinum Roof Underlayments refer to a current Approved Roofing Materials Directory for fire
ratings of this product. I
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied
1. This Notice of Acceptance.
2. Any other document's required by the Buil
evaluate the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance;
fire ratings of this product.
of the following:
Official or applicable building code in order to properly
to a current Approved Roofing Materials Directory for
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building bode.
3, FT Synthetics Silver, FT Synthetics Gold, FT Sy Ithetics Platinum Roof. Underlayments shall be applied to a
smooth,. clean and dry surface with deck free of irregularities. All nails in the deck shall be carefully checked
for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and
debris prior to application.
-4. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall not be hot
mopped, refer to manufacturer's published literature for product compatibility.
5. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall not be applied
over an existing roof membrane as a recover system.
6, FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments shall not be left
exposed as a temporary roof for longer than 30 days of application.
7. FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments are components used
in roof system assemblies. Roof system assemblies are approved under a specific Notice of Acceptance. Refer
to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
NOA No.: 16-0510.30
Page 3 of 4
$, FT Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments may be used with any
approved roof covering Notice of Acceptance listing FT Synthetics Silver, FT Synthetics Gold, FT Synthetics
Platinum Roof Underlayments as a component part of an assembly in the Notice of Acceptance. If FT
Synthetics Silver, FT Synthetics Gold, FT Synthetics Platinum Roof Underlayments are not listed, a request
may be made to the Authority Having Jurisdiction'(AHJ) or the Miami -Dade County Product Control
Department for approval provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing�results.
9. All products listed herein shall have a quality as audit in accordance with the Florida Building Code
and Rule'61G20-3 of the Florida Administrative I Code.
10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city; state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
County Product Control Seal as shown below.
END OF THIS ACCEPTANCE
i
i
NOA No.: 16-0510.30
Page 4 of 4
MIAMI•DAD
DEPARTMENT OF REGULATORY AND ECONOMIC
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA
GAF
1 Campus. Drive
Parsipanny, NJ 07054
MIAMI-:DADE COUNTY
PRODUCT CONTROL SECTION
JRCES (RER) 11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.sov/economv
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
I
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes,. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such1testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the. right to revoke this acceptance,
if it is determined by Miami -Dade County Product Cont of Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Leak Barriers and Roof Deck Protection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal o`f NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA 16-1213.04 and consists of pages 1 through 10.
The submitted documentation was reviewed by Hamley Pacheco, P.E.
MIAMI-DADS COUNTY NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 1 of 10
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS/Polypropylene/Asphalt
PRODUCTS DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Description
WeatherWatch® Mineral
36" x 50' rolls
ASTMiD 1970
Granular surfaced modified, fiberglass reinforced,
Surfaced Leak Barrier
36" x 66.7' rolls
bituminous sheet material for use as a leak barrier
Manufacturing
underlayment in sloped roof assemblies.
Location #1, 9
Designed as an ice & rain shield.
Film
= 36" x 66.7' rolls
ASTM D-1970
C1Vlodified, fiberglass reinforced, bituminous sheet
�StormGaardo
Surface'd_L-eak-Barrier
_
'material' for use as a high temperature leak -barrier
Manufacturing}
underlayment in sloped roof assemblies.
Location #1;t9
i
-Designed as an ice & rain shield.
LibertyTm SBS Self-
39 3/8" x 66' rolls
AST1V� D 1970
Self -adhering SBS roof membrane.
Adhering Base/Ply Sheet
ASTM D4601
Manufacturing
Type II
Location #1, 9
Deck-ArmorT' Premium
54" x 222' rolls
i
ASTM D 226
A UV -stabilized polypropylene breathable
Breathable Roof Deck
48" x 100' rolls
Type II
underlayment. To be used for roof deck
Protection
protection as an underlayment in sloped roof
Manufacturing
assemblies.
Location #2
Tiger Paw" Roof Deck
48" x 250' rolls
ASTM D 226
A UV -stabilized polypropylene non -breathable
Protection
48" x 100' rolls
Type II
underlayment. To be used for roof deck protection
Manufacturing
as an underlayment in sloped roof assemblies.
Location #3, 5, 6
FeltBuster® High -Traction
48" x 250' rolls
ASTM D 226
A UV -stabilized polypropylene non -breathable
Synthetic Roofing Felt
Type I
underlayment. To be used for roof deck protection
Manufacturing
as an underlayment in sloped roof assemblies.
Location #7, 8
Shingle -Mate® Roof Deck
36" x 144' rolls
ASTM D 226
Fibergass-reinforced asphalt felt underlayment. To
Protection
Type I
be used for roof deck protection as an
Manufacturing
underlayment in sloped roof assemblies.
Location #4
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 2 of 10
PRODUCTS DESCRIPTION:
(Test
Product
Product
Dimensions
Specification
Description
LibertyTM SA Glass Cap
39 3/s" x 34' rolls
ASTM D 1970
Granular surfaced modified, fiberglass reinforced,
Sheet
ASTM P 6163
self -adhering SBS roof membrane.
Manufacturing
ASTM D 7530
Location # 9
1
GAFGLAS® Ply 4
39.37"
ASTM 4 D2178
Aspahalt impregnated glass felt with aspahlt
Manufacturing
(1 meter) Wide
Type IV
coating.
Location # 9, 10
GAFGLAS® FlexPIyTI' 6
39.37"
ASTM D2178
Aspahalt impregnated glass felt with aspahlt
Manufacturing
(1 meter) Wide
Type VI
coating.
Location # 9, 10
MANUFACTURING LOCATION:
1.Mt. Vernon, IN
2.North Bay, Ontario
3.Mission, British Columbia
4.Pryor, OK
S.Qingdao, China
6.Charleston, SC
7.Spartanburg, SC
8.Dadra, India
9.Savannah, GA
IO.Mobile, AL
I
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 3 of 10
i
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Intertek Testing Services NA Ltd.
3077464-101
ASTM D 1970
08/23/06
3090131
Wind Uplift and Self Seal ability
08/23/06
100258583CO9-010A
ASTM D 226 Type II
01/08/11
100673818COQ-003
ASTM D 226 Type II
06/13/13
10157289000Q-005
ASTM D 226 Type II
04/17/14
F8549.02-106-18
ASTM D 226 Type I
11/08/16
PRI Construction Materials
RGM-023-02-01
ASTM D 4798
05/16/07
Technologies, LLC.
GAF-112-02-01
ASTM D 226 Type II
03/15/06
GAF-238-02-01
ASTM D 1970
03/03/10
GAF-323-02-01
ASTM D 1970
11/30/11
GAF-324-02-01
ASTM D 1970
12/01/11
GAF-325-02i O1
ASTM D 1970
12/01/11
GAF-326-02'-O1
ASTM D 1970
11/30/11
GAF-275-02-01
ASTM D 1970
11/11/10
GAF-344-02i01
ASTM D 1970
04/23/12
GAF-339-021,01
ASTM D 226 Type I
03/14/12
ELK-311-02',O1
ASTM D 1970
09/11/07
GAF-518-02 ',O 1
ASTM D 226 Type 1
06/04/14
GAF-818-02 0I
ASTM D 4533
12/06/17
GAF-829-02-01
ASTM D 226 Type II
01/15/18
GAF-314-02-61
ASTM D 2178
07/21/11
GAF-315-02-61
ASTM D 2178
07/21/11
Trinity-ERD
GAF-SC13285.03.17-1
ASTM D 1970
03/08/17
GAF-SC13285.03.17-3
ASTM D 1970
03/01/17
GAF-SC13285.03,.17-4
ASTM D 1970
03/01/17
GAF-SC13285.02,.17-2
ASTM D 4601 Type II
02/08/17
GAF-SC9700.08-15-RI
ASTM D 2178
09/09/15
GAF-SC12915.12.17-RI
ASTM D 1970
12/11/17
GAF-SC12915.12.17-RI
ASTM D 6163
12/11/17
GAF-SC12915.12.17-RI
ASTM D 7530
12/11/17
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 4 of 10
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E (1): Anchor sheet mechanically fastehed to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type�I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck-ArmoJm Premium Breathable Roof Deck Protection, FeltBuster®
High -Traction Synthetic Roofing,. Felt, or Tiger PawTM Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). AlwaysI, apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
i
Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film
Surfaced Leak Barrier, LibertyTml SA Glass Cap Sheet, or LibertyTm SBS Self -Adhering
Base/Ply Sheet membrane with a'minimturi 3" side lap and 6" end lap. Place the first course of
membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the
release membrane as the membrane is applied. Vertical strapping of the roof with
WeatherWatch® Mineral Surfaced Leak Barrier, or StormGuard® Film Surfaced Leak Barrier is
acceptable.
Surfacing: Approved Roofing Assembly.
I
M �.R®� NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 5 of 10
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Membrane mechanically fastened to deck.
Separator Sheet: One or more plies of GAFGLAS® Ply 4, GAFGLAS®F1exPlyTm 6, Shingle -Mate® Roof Deck
Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -
Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection loose laid.
Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film
Surfaced Leak Barrier, LibertyTM,SA Glass Cap Sheet, or LibertyTM SBS Self -Adhering
Base/Ply Sheet membrane mechanically fastened with a minimuin 3" side lap and a 6" end lap to
deck through the separator sheet with approved nails and tin caps 6" o:c. at the laps and two
staggered rows 12" o.c. in the field of the roll.
Surfacing: Approved Roofing Assembly.
CMAMMMECOM
—B 4 1
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 6 of 10
Deck Type 1: Wood, non -insulated 1.
Deck Description: 19/32" or greater plywood or wood plank
System E (3): Anchor sheet mechanically fastened to deck, membrane adhered.
Secondary Water Install a minimum 4" wide WeatherWatch® Mineral Surfaced Leak Barrier, , LibertyTM SBS
Barrier: Self -Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, or StormGuard® Film Surfaced
(Optional) Leak Barrier membrane over the joints of the plywood roof deck prior to installation of the base
sheet. Do not overlap end or side joints. All side and end laps should be butted firmly side by
side, flush with each other but not overlapped. Do not leave the WeatherWatch® Mineral
Surfaced Leak Barrier, or StormGIuard® Film Surfaced Leak Barrier membrane exposed for more
than 30 days without a roof deck protection underlayment protecting the secondary water barrier.
Base Sheet: Two plies of ASTM D 226 Type I for Shingle -Mate' Roof Deck Protection OR one or more plies
of ASTM D 226 Type I1, Deck-ArmorTM Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection with a
minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and four�lstaggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fasteners.
Surfacing: Approved Roofing Assembly.
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 7 of 10
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood' plank
System E (4): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I� or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck-ArmorTM Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection with a
minimurn 4" side lap and a 6" end jap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and four, staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of StormGuardo Film Surfaced Leak Barrier membrane with a minimum 4"
side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied. i
Surfacing: Approved for Metal roofing, Slate, and Asphalt Shingle assemblies.
I
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 8 of 10
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, Liberty'r1*1 SBS Self -
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck -Armor m
Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection shall not be used as roof tile underlayment.
3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak
Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, Liberty"mt SA Glass Cap Sheet, Shingle -Mate® Roof Deck
Protection, Deck -Armor' Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic
Roofing Felt, and Tiger PawTM Roof Deck Protection shall be installed in strict compliance with applicable
Building Code.
4. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM
Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection membranes shall be applied'', to a smooth, clean and dry surface with deck free of
irregularities.
5. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering Base/Ply Sheet, Liberty"rm SA Glass Cap Sheet, Shingle -Mateo Roof Deck Protection, Deck-ArmorTM
Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection membranes shall not be applied over an existing roof membrane.
6. WeatherWatch® Mineral Surfaced Leak' Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM
Premium Breathable Roof Deck Protection, FeltBuster®' High -Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application.
7. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM
Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatch®
Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply
Sheet, LibertyT" SA Glass Cap Sheet, Shingle -Mateo Roof Deck Protection, Deck-ArmorTM Premium Breathable
Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection
as a component part of an assembly in the Notice of Acceptance. If WeatherWatch® Mineral Surfaced Leak
Barrier, StormGuardo Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, LibertyTM SA
Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt and Tiger PawTM Roof Deck Protection are not listed; a request
may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department
for approval provided that appropriate documentation is provided to detail compatibility of the products, wind
uplift resistance, and fire testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45' F and
rising.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions.
NOA No.: 18-0119.15
MIAMI-MDE COUNTY
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 9 of 10
LIMITATIONS:
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetration's in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Coder
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
END OF THIS ACCEPTANCE
NOA No.: 18-0119.15
MIAWDAD�Fgurt' COUNTY ynlj Expiration Date:02/22/23
-0119.15
Approval Date: 02/22/18
Page 10 of 10
CREEK
TECHNICAL SERVICES,. LLC
EVALUATION REPORT
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 6Te EDITION (2017)
Manufacturer:
DREXEL METALS, INC.
Issued September 14, 2017
1234 Gardiner Lane
Louisville, KY 40213
(502) 716-7143 '
www.drexmet.com
Manufacturing:
Drexel Metals Associl tion of Regional Manufacturers (DM -ARM)
Quality Assurance:
Architectural Testing, Inc. (QUA1844)
SCOPE
RECEIVED
Category:
Roofing
MAY 31 2018
Subcategory:
Metal Roofing
Code Sections:
1504.3
ST. Lucie County, Permitting
Properties:
Wind Resistance
REFERENCES
Entit
Report No.
Standard
Year
Architectural Testing (TST1558)
56840.02-122-18
TAS 100
1995
Architectural Testing (TST1558)
58389.01-122-44
UL 580
2006
Architectural Testing (TST1558)
58459.01-122-44
UL 580
2006
Architectural Testing (TST1558)
58461.01-122-44
TAS 125
2003
Architectural Testing (TST1558)
8I 776.01-109-44
UL 580
2006
UL 1897
2012
Architectural Testing (TST1558)
82784.01-109-44
UL 580
2006
'
UL 1897
2012
Architectural Testing (TST1558)
83296.01-109-44
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
178-0054T-12
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
178-0055T-12
UL 580
2006
UL 1897
2012
Hurricane Test Laboratory (TST1527)
0287-0209-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0308-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0311-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0313-07
TAS 125
2003
Hurricane Test Laboratory (fST1527)
0287-0512-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0706-07
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
VLS-005-02-01
ASTM B 117
2016
TAS110
2000
PRI Construction Materials Technologies (TST5878)
VLS-004-02-01
ASTM G 155
2005a
TAS110
2000
PRI Construction Materials Technologies (TST5878)
DMC-004-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-005-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-006-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-007-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-008-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-009702-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-014-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-016-02-01
TAS 100
1995
PRIConstruction Materials Technologies (TST5878)
DMC-017-02-01 Rev 1
UL 580
2006
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
DMC-018-02-01
UL 580
2006
UL 1897
2012
PRI Construction Materials Technologies (TST5878) DMC-024-02-01 UL 580 2006
UL 1897 2012
DRX15001.4 FL17678-R4 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality 'assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
l
Entitv
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
DM-033-02-01.1
UL 580
2006
UL1897
2012
PRI Construction Materials Technologies (TST5878)
DMC-037-02-01
UL 580
2006
UL1897
2012
PRI Construction Materials Technologies (TST5878)
DM137-02-02
UL 580
2006
UL1897
2012
PRI Construction Materials Technologies (TST5878)
DMC-038-02-01
UL 580
2006
UL 1897
2012
PRODUCT DESCRIPTION
01VIC100NS" + Profile: tr" ; �`1:iii: snap lock seam- Max.16 in. coverage =:'
:. - .._..._ .._ _ _ .. _ .. _....
Description _Non-structural, snap lock standing seam roof panel with integral perorated nail
'� strap
Material: ; Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
, -ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
i
.......................................
i
II 5 1" o.C.
i
DMC 150SL Profile: 1.5 in. snap lock seam; Maxl 16 in. coverage
................ ....... .I— ............. ... r----------------------- - ................
Description Non-structural, snap lock standing seam roof panel
................. :_ . g . _..._............ .............
Material: ; Min. 24 a. Fluro on® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
_,..._......:....................._....._......._...................................__...__.........._..._._...._....._..--------•-•-------•-----........................_........_._..
T
12
I
DMC 15OSS Profile: 1.5 in. mechanical seam; Max_ 1.6 in. coverage
-_.---.._.._............ .....................................
Description: ; Non-structural, mechanical lock standing seam roof panel
! Material: j Min. 0.032 in. Fluropon® coated 'ASTM B209 aluminum; Fy = min. 16 ksi; Shall
conform with FBC Section 1507.4.3
.........._ ............... ._.........................:...........
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min: 50 ksi: Shall conform with FBC Section 1507.4.3
............ .... .............. .
2 3" B
9
12 1is
I-- ------- 16" --- -- I
DRX15001.4 FL17678-R4 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
a
I
CREEK
TECHNICAL SERVICES, LLC I
DMC 175S Profile: 1:75 in. snap lock sear
........._ _
Description: Non-structural, snap lc
Material: ; Min. 0.032 in. Fluropor
conform with FBC See
Min. 0.040-inch Flurop
I conform with FBC Sec
................
Min. 24 ga. Fluropon®
ASTM A653 G90; Fy =
DREXEL METALS, INC.
Metal Roofing
n; Max __18 In. coverage
....... ....... .. _ _.......------- ..............................
ck standing seam roof panel ................_................................... _.._ ..._. .... . .
I R coated ASTM B209 aluminum; Fy = min. 16 ksi; Shall
tion 1507.4.3
on® coated ASTM B209 aluminum (Fy = min. 20 ksi); Shall
tion 1507.4.3
(coated ASTM A792 AZ50, or
min. 50 ksi; Shall conform with FBC Section 1507.4.3
-I— I
I
1 a'
I i I
16"
DMC 200S Profile: 2 in. mechanical seam; Max. 16 in. coverage
.........................---------------------------.-..__............- --._.-----._--...._.._._..--------------------------
Description: Non-structural, mechanical lock standing seam roof panel
f....._. _._.. .......
Material: Min. 0.040 In. Fluropon® coated ASTM 6209 aluminum; Fy = min. 20 ksi; Shall
' conform with FBC Section "1507.4.3
1................_...._..._...------------._..._...__ -- ... ...---------
.........
...........................
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; F = min.'50 ksi; Shall conform with FBC Section 1507.4.3
...............L...-.........._......._..._..............................:....................................-.._..._...................._......................__...................._....._ ................, ...........
r 13. s,. I
I --I 16 B r
1,..r
2 2" 2"
_J
16"--
DMC 450 Profile: 1.5 in. snap lock seam; Max. 16 in. coverage
Description, `, Non-structural, snap lock
_ __.__-_.__ ..._---.--o
p . p .. standing seam_ roof .panel with concealed clip
Material: 1 Min. 24 ga. ASTM A792 or ASTM A653; Fy = min. 50 ksi; Shall conform with FBC
Section 1507.4.3
. .... _ ..__....... ..... ....................... .........---------- .__...._.__---- ............ ... -.........
-- ..
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 24 ksi; Shall
1 conform with FBC Section 1507.4.3
r
1 z"
I i
�— -- - - 16"------- — _�
DRX15001.4 FL17678-R4 Page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
C R C E K
DREXEL METALS, INC.
G (�
Metal Roofing
TECHNICAL SERVICES, LLC
DMC 5V Profile:
j 3/8 in. ribs; 24 in. coverage
I Description:
Non-structural, through fastened roof panel
Material:
Min. 26 ga. FluroponO coated ASTM A792 or ASTM A653 G90 ; Fy = min. 50 ksi;
Shall conform with FBC Section 1507.4.3
I
-
i
- 1 24" Coverage -
_ .. .. .... .....
9, 119. _ 16
1116
,
' 3„
8
DMC Profile:
1/2 in, corrugation; 21 in..,coverage
_._. ....
Corrugated i Description:
...
_...------------........ .........
I Non-structural, through fastened roof panel
._ ...... . _ . .
Material:
Min. 26 ga. Fluropon@ coated ASTM A792 or ASTM A653 G90 ; Fy = min. 40 ksi;
?
Shall conform with FBC- Section...1507.4.3
- -- -
Mln 0 032 In Fluropon� coated ASTM 6209 aluminum; Fy =min. 19 ksi; Shall
conform with FBC Section �1507 4 3
I _ _.__.._-....... - ..
......_ . ._........
r,
i
I I
ir.....L. - .......
I
LIMITATIONS
I
I
1. Fire classification is not within the scope of this evaluatidln.
2. This report is not for use in the HVHZ.
3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4. Roof slope shall be in accordance with FBC Section 1507.4.2.
5. Reroofing shall be in accordance with FBC Section 1511.
6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
7. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
I
DRX15001.4 FL17678-R4 Page 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
DREXEL METALS, INC.
Metal Roofing
The products evaluated herein by Zachary R. Priest, lIP.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.'
``,
%tj%t1 a t����i��i
�G�p FtY ....
•,,��'ENs".�s�'- 2017.09.14
No 74021 / 1 6:34:1 J
0'. STATE OF :��/"—041001
--�'��•�4 O R O P'���` Zachary R. Priest, P.E.
RegistrationFlorida 21
�1 A` i Organization No.A E9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
i
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
i
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
i
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A —installation (11 pages) I
2) APPENDIX B — Approved Roof Systems (7 pages)
3) APPENDIX C — Design Wind Loads(4 pages)
DRX15001.4 FL17678-R4 Page 5 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.