HomeMy WebLinkAboutNOADEPARTMENT OF REGULATORY AND ECONOMIC BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE I RECEIVED JUN 01 2018 ST, Lucie County, Permittin I_110 MIAMI-DADE COUNTY 'RODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 Petersen Aluminum Corporation REQUIRED BY FIELD INSPECTORS THAT 102 Northpoint Parkway, B1dg.106 MAY BE NECESSARY IN ORDER TO Acworth, GA. 30102 COMPLY WITH ALL APPLICABLE CODES. SCOPE: This NOA is being issued under the applicable ru�'es and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Edge-Loc 1.0: x 16" wide x 24 ga. Steel Panel over Wood Deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered afte i r a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA 14-0129.11 and consists of pages 1 through 5. The submitted documentation was reviewed by Freddy Semi%no CONCEALED FASTENERS OR ATTACHMEINTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD —�_00= - QMIAMMINADEMCOUtvTr T. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANC REVIEWED BY DATE ` NOA No.: 17-1002.16 Expiration Date: 03/16/24 Approval Date: 11/02/17 Page 1 of 5 PLANS AND PERMIT MUST BE KEPT ON JOB FILE SITE OR NO INSPECTION(S) WILL BE MADE COPY ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Metal, Panels(Non-Structural) Materials: Steel Deck Type: Wood Maximum Design Pressure —101 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Descrintion Edge-Loc 1.0 Length: various TAS 110 Corrosion resistant, prefinished, coated Width: 16" galvanized, galvalume, standing seam, metal Height: 1" panels. Thickness 0.024" (24 ga.) Min. Yield Strength: 50 ksi Trim Pieces Length: varies N/A Corrosion resistant, prefinished, coated Width: varies galvanized, galvalume, standing seam, metal Thickness 0.024" (24 ga.) panels. EVIDENCE SUBMITTED: Test Agencv Test Identifier Test Name/Report Date Valspar 433X515 ASTM B 117 11/21/11 Valspar' 433B143 ASTM D 4587, ASTM G 23 11/21/11 Force Engineering & Testing 72-0314T-06A-C TAS 125 03/24/07 Inc. Farabaugh Engineering and T158-07A TAS 100 04/14/07 Testing Inc. NOA No.: 17-1002.16 Expiration Date: 03/16/24 Approval Date: 11/02/17 Page 2 of 5 APPROVED ASSEMBLIES: System: Edge-Loc 1.0 Panel x 116" Wide x 24 ga. Steel Deck Type: Wood, Non -Insulated i Deck Description: New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or greater plywood. i Slope Range: 2": 12" or greater Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") The above attchment method must be in addition to existing attachment. Underlayment: i Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 11/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 ors Association's current published installation instructions. and with PAC Contrac�1.0 Metal Panels and Install the "Edge-Loc Panel" and accessories in compliance with the current published Accessories: installation instructions and details in PAC Contractors Association's Installation Manual. Flashings, penetrations, valley construction and other details shall be constructed in compliance with Roofing Application Standard RAS 133. I Panels shall be secured at a spacing listed below in Table A with corrosion resistant #10-13 x 1" pancake head screws of sufficient length to penetrate through the sheathing a minimum 3/16 of an inch. The adjacent panel shall overlap and be secured to each other when The female rib of panel is snapped over the male rib of panel. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas ! Field Perimeter and Corner' Maximum Design Pressures —59.75 psf. —101 psf. Maximum Screw Spacing 16" o.c. 6.75" o.c. 1. Extrapolation shall not be allowed NOA No.: 17-1002.16 Expiration Date: 03/16/24 Approval Date: 11/02/17 Page 3 of 5 SYSTEM LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133. 1 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city, state, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. 5. All products listed herein shall have a quality iassurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 6. Panels may be shop or jobsite roll formed with machine models # 10110884, E00578860, or 01110072 from PAC Contractors Association or manufactured at Petersen Aluminum Corporation's plant in Acworth, GA. NOA No.: 17-1002.16 Expiration Date: 03/16/24 Approval Date: 11/02/17 Page 4 of 5 Z r- i I PROFILE DRAWINGS I Fastener Relief, Stiffening Ribs and Striations are Optional Field Condition I I EDGE-LOC 1.0 PANEL SYSTEM i END OF THIS ACCEPTANCE I NOA No.: 17-1002.16 Expiration Date: 03/16/24 Approval Date: 11/02/17 Page 5 of 5 MAt+41• L DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA Owens Corning One Owens CorningParkway Toledo, OH 43659 RECEIVLE , ` JUN 01 2018 ST. Lucie County, permitting 1 I MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.Eov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance puoses. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of they Florida Building Code. DESCRIPTION: Weatherlock® Specialty Tile & Metal Underlayment LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. I TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and reln�I val of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 13-1010.03 and consists of pages 1 through 4. The submitted documentation was reviewed by Alek Tigera. Al I 90 MIAMI•DADE COUNTY ... b m FILE COPY NOA No.: 17-0522.01 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Weatherlock® 36" x 33.3' rolls TAS 103 SBS self -adhering asphalt sheet material with a Specialty Tile & 36" x 66.7' rolls ASTM D 1970 white or green glass re -enforced polyester Metal Underlayment surfacing fabric; for use as an underlayment in sloped roof assemblies. MANUFACTURIGN LOCATION: 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMITTED: I Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. R14610 Follow up Service 03/28/02 IRT-Arcon, Inc. 02-012 TAS 103 02/28/02 PRI Asphalt Technologies, Inc. NEI-006-02-01 TAS 103 04/01/02 NEI-008-02-01 TAS 114 (H) 07/30/02 PRI Construction Materials NEI-045-02-01 ASTM D 4798 & ASTM G 155 08/08/07 Technologies, LLC. NEI-053-02-01 ASTM 1) 4798 & ASTM G 155 05/01/08 NEI-076-02-01 TAS 103 / ASTM D4798 02/14/11 NEI-034-02-02 ASTM D 1970 10/28/13 OCF-312-02-01 ASTM D 1623 07/03/17 OCF-320-02-01 I TAS 103 06/28/17 NOA No.: 17-0522.01 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated, new construction Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. i Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c.ithe field of the roll. Membrane: One or more plies of Weath6rlock® Specialty Tile & Metal Underlayment with a minimum 3" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maxim�' m contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with Weatherlock® Specialty Tile & Metal Underlayment is acceptable. Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. NOA No.: 17-0522.01 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this accepta 2. This acceptance is for prepared roofing a] applicable building code. Weatherlock® compliance with applicable Building Code. 3. Weatherlock® Specialty Tile & Metal unde free of irregularities. 4. Weatherlock® Specialty Tile & Metal um recover, but may be applied over roofing B, 5. Weatherlock® Specialty Tile & Metal unde 90 days of application. 6. The standard maximum roof pitch for Weal are loaded directly to the Weatherlock® required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product specific prepared roofing products. 8. Tiles shall be stored on battens on roof nitc] 9. Weatherlock® Specialty Tile & Metal and Acceptance listing Weatherlock® Specialty Notice of Acceptance. If Weatherlock® Spe to the Authority Having Jurisdiction (AHJ) provided that appropriate documentation is and fire testing results. 10. All nails in the deck shall be carefully chec the deck thoroughly to remove any dust and Minimum deck requirements shall be in compliance with Tile & Metal underlayment shall be installed in strict shall be applied to a smooth, clean and dry surface with deck Etyment shall not be applied over an existing roof membrane as a Anchor sheet underlayment. yment shall not be left exposed as a temporary roof for longer than Specialty Tile & Metal underlayment shall be 6:12 when tiles Tile & Metal underlayment; loading boards or battens are Notice of Acceptance for listed approval of this product with greater than 6:12". ryment may be used with any approved roof covering Notice of & Metal underlayment as a component part of an assembly in the lty Tile & Metal underlayment is not listed, a request may be made the Miami -Dade County Product Control Department for approval Med to detail compatibility of the products, wind uplift resistance, for protruding heads. Re -fasten any loose decking panels. Sweep ris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Weatherlock® Specialty Tile & Metal underlayment shall be applied over the underlayment. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 1 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. I END OF THIS ACCEPTANCE NOA No.: 17-0522.01 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 4 of 4