HomeMy WebLinkAboutPRODUCT APPROVALFlorida
�i,,
y
�� ►�"'' Product Approval
�- ),USER: Public User
Product Approval Menu > Product or ADDllcation Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archlved
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL9555-R4
Revision
2017
Approved
SCANNED
BY
St hirl 01"O"
UNION CORRUGATING COMPANY
701 S. KING ST.
FAYETTEVILLE, NC 28301
(910)483-0479 Ext256
jstleby@unioncorrugatlng.com
John Stleby
jstleby@unioncorrugating.com
Structural Components
Roof Deck
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Bala Sockalingam
PE-62240
Keystone Certifications, Inc.
09/07/2027
Yoosef Lavl, P.E.
+' Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard) Standard
ASTM E1592
FM 4470
Equivalence of Product Standards
Certified By
Sections from the Code
FILE COPY
Year
2005
2012
httpsJ/www.floddabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgtvOROQkZA5RE8EOgziUdi7ntuFlu2jC5s%3d 1/3
1/9/2018 'Florida Building Code Online
Product Approval Method Method 1 Option D
10
Date Submitted
08/23/2017
Date Validated
08/28/2017
Date Pending FBC Approval
09/09/2017
Date Approved
12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
9555.1
5V Panel
29 ga., 24" wide, through fastened panel over wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationReoortC2172 S.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-70.25
Evaluation Reports
Other: Uplift load of 70.25 psf @ support spacing of 24" o.c.
FL9555 R4 AE Eva IuationReoortC2172 i.Ddf
Created by Independent Third Party: Yes
9555.2
MasterRib Panel
26 ga., 36" wide, through fastened panel over steel supports
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL9555 R4 II EvaluationReoortC2172 2.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-47.2
Evaluation Reports
Other: Uplift load of 47.2 psf @ support spacing of 60" o.c.
FL9555 R4 AE EvaluationReoortC2172 2.Ddf
Created by Independent Third Party: Yes
9555.3
MasterRib Panel
29 ga., 36" wide, through fastened panel over steel supports
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL9555 R4 II EvaluationReoortC2172 3.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +27.1/-37.7
Other: Design load of 27.1 & -37.7 psf at support spacing of
48" o.c.
Evaluation Reports
FL9555 R4 AE EvaluatlonReoortC2172 3.odf
Created by Independent Third Party: Yes
9555.4
MasterRib Panel
29 ga., 36" wide, through fastened panel over wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: iYes
FL9555 R4 ii EvaluationReportC2172 4.Ddf
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +27.1/-36.2
Other: Design load of 27.1 &-36.2,psf at support spacing of
Evaluation Reports
FL9555 R4 AE Eva luatlonReoortC2172 4.Ddf
48" o.c.
Created by Independent Third Party: Yes
9555.5
MasterRib Panel
29 ga., 36" wide, through fastened panel over nom. 1" x 4"
wood supports
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL9555 R4 I1 EvaluatlonReoortC2172 S.DdF
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.9
Evaluation Reports
Other: Uplift load of 138.9 psf @ support spacing of 24" o.c.
FL9555 R4 AE Eva luationReDortC2172 5.Ddf
Created by Independent Third Party: Yes
9555.6
PBR Panel
Min. 26 ga., 36" wide, through fastened roof panel over open
steel supports
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL9555 R4 H EvaluationRenortC2172 6.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +96/-163
Evaluation Reports
Other: Design loads of 96 & -163 psf at support spacing of
FL9555 R4 AE Eva luationReoortC2172 6.odf
20" o.c.
Created by Independent Third Party: Yes
D:(c:( i4a(t
Contact Us :: 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone: 050-487-1824
The State of Florida Is an AA/EEO employer. Comtriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. N you do not want your e-mall address released In response to a public -records request, do not send electronic
httpsJ/www.floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgtvOROQkZA5REBEOgziUdi7ntuFlu2jC5s%3d 2/3
1/g/2018
Florida Bt lding Cade Online
mall to this entity. Instead, contact the office,by phone or by traditional mall. If you have any questions, please contact 850.4137.1395. -Pursuant to Section
45S.27S(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emalis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a Ikensee under Chapter 4S5, F.S.,
please dick bg .
Product Approval Accepts:
11
Credit Card
Safe
httpsJ/www.floddabuilding.org/prlpr app till.aspx7param=wGEVXQwtDgtvOROQkZA5REBEOgziUdi7ntuFlu2jC5s%3d 313
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
;'29 GA: 5V PANEL'
OVER WOOD SUPPORTS
I
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 9555.1-R4
STRUCTURAL COMPONENTS
U
ROOF DECK
Prepared For:
in Corrugating Company
P. O. Box 229
'ayetteville, NC 28302
ephone: (910) 483-0479
Fax: (910) 483-8897
Prepared By:
Bala Sockalingam, Ph.D., P.E..
Florida (Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
I
Report No. C2172-1
Date: 8 20.2017
36a�94AA9A0Bg��
t°0 GYA L I JVQ I,.,
yovQ ..........
N S
%%
d,
lyo
oCr
LU
O ¢ ; Cu
S•
Manufacturer:
Product Name:
Panel Description:
Materials:
Support Description:
Slope:
FL 9555.1-R4
C2172-1
8.20.2017
Page 2 of 3
Union Corrugating Company
5V Panel
24" wide'coverage with (5)1/2" high ribs
Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Nom. 1" k 4" (min) lumber (Southern Yellow Pine Untreated)
(Must be (designed by others)
1/2:12 orIgreater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 70.25 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) (3 or more spans)
Panel Attachment: #9-15 or #10-14 x 1-1/2" long wood screws with washer
At panel ends @ 12" o.c. across panel width
At intermediate @ 12" O.C. across panel width
Test Standards: Roof assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural Performance of Sheet Metal Roof and Siding
Systems i by Uniform Static Air Pressure Difference' and FM 4470
Section 5.5 `Resistance to Foot Traffic'.
Test Equivalency: The test I procedure in ASTM E 1592-01 comply with test procedure
prescribed in ASTM E1592-05(2012).
The test procedure in FM 4470 (1992) comply with test procedure
prescribed
d in FM 4470 (2012).
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. ;The maximum support spacing listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineei. This product is not approved for use in the High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
approved roofing materials directory for fire ratings of this product.
FL 9555.1-R4
C2172-1
8.20.2017
Page 3 of 3
Supporting Documents: ASTM E1592 Test Report
Farabaugh Engineering and Testing Inc
Project N;o. T246-06, Revised Reporting Date 11/7/06
1
FM 44701 Test Report
ENCON Technology Inc
C1583-3; Reporting Date 7/24/08
PANEL IFASTENER
#9-151 OR #10-14 X 1.5" LONG WOOD
SCREWS @ MAX 12" O.C.
I
FASTENER PATTERN
SUPPORT SPACING = 24" O.C.
ALLOWABLE (UPLIFT PRESSURE = 70.25 -PSF
12'
NOM. 1" X 4" (MIN)
SYP UNTREATED rl
(DESIGN BY OTHERS) O
m
a
1/2'T
24. _
5V Panel Profile
Minimum 29 Gouge, Minimum Yield a 80 KSI
r
1/9/2018 Florida Elilding Code Online
BCIS Home ` Login j User Registration Hot Toplcs j Submit Surcharge i Stats & Fads i PubllcaUons FBC Staff j BCIS Site Map Unks j Search j
Florida
61,
�] us Product Approval
VD 1 USER: Public User
p:y c c,• "�
Product Aooroval Menu > Product or Anolicadon Search > Aoollcatlon Ust > Application Detall
FL # FL9555-114
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETMVILLE, NC 28301
(910)483-0479 Ext256
jstleby@unioncorrugating.com
Authorized Signature John Stieby
JsUeby@unioncorrugating.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi, P.E.
s Validation Checklist - Hardcopy Received
Certificate of Independence FL9555 R4 COI CertificateIndeoend
Referenced Standard and Year, (of Standard) Standard
ASTM E1592
FM 4470
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2005
2012
httpsJAvww.floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgtvOROQkZA5RE8EOgziUdi7ntuFI42JC5s%3d 1/3
1/9/2018 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
08/23/2017
08/28/2017
09/09/2017
12/12/2017
FL # I Model, Number or Name Description
9555.1 1 5V Panel 29 ga., 24" wide, through fastened panel over wood supports
Limits of Use Installation Instructions
Approved for use in HVHZ: Na FL9555 R4 II EvaluationReDOrtC2172 1.Ddf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-70.25' Evaluation Reports
Other: Uplift load of 70.25 psf @ support spacing of 24" o.c. EL9555 R4 AE EvaluatlonReoortC2172 i.Ddf
Created by Independent Third Party: Yes
9555.2 MasterRib Panel 26 ga., 36" wide, through fastened panel over steel supports
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL9555 R4 II Evaluation Rem rtC2172 2.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-47.2 1 Evaluation Reports
Other: Uplift load of 47.2 psf @ support spacing of 60" o.c. FL9555 R4 AE EvaluationReoortC2172 2.017
Created by Independent Third Party: Yes
19555.3 1 MasterRib Panel 129 ga., 36" wide, through fastened panel over steel supports
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL9555 R4 II EvaluationRQportC2172 3.Ddf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A i Created by Independent Third Party: Yes
Design Pressure: +27.1/-37.7 Evaluation Reports
Other: Design load of 27.1 & -37.7 psf at support spacing of FL9555 R4 AE Eva luatlonReoortC2172 3.odf
48" o.c. Created by Independent Third Party: Yes
19555.4 1 MasterRib Panel 129 ga., 36" wide, through fastened panel over wood supports
Limits of Use i Installation Instructions
Approved for use in HVHZ: No FL9555 R4 Ii Evaluation RenortC2172 4.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +27.1/-36.2 Evaluation Reports
Other: Design load of 27.1 & -36.2 psf at support spacing of FL9555 R4 AE EvaluationReoortC2172 4.odf
48" o.c. Created by Independent Third Party: Yes
9555.5
MasterRlb Panel
29 ga., 36" wide, through fastened panel over nom. 1" x 4"
wood supports
Limits of Use
Installation Instructions
Approved for use In HVHZ:! No
FL9555 R4 II EvaluationReportC2172 5.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.9
Evaluation Reports
Other: Uplift load of 138.9 psf @ support spacing of 24" o.c.
FL9555 R4 AE EyaluationReportC2172 5.Ddf
Created by Independent Third Party: Yes
9555.E PBR Panel Min. 26 ga., 36" wide, through fastened roof panel over open
steel supports
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9555 R4 II EvaluationReoortC2172 6.Ddf
Approved for use outside'HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A I Created by Independent Third Party: Yes
Design Pressure: +96/-163 Evaluation Reports
Other: Design loads of 96 & -163 psf at support spacing of FL9555 R4 AE EvaluationReoortC2172 6.odF
20" o.c. Created by Independent Third Party: Yes
1ae;t ilcat
Contact Us :: 2601 Blair Stone Road, Tallahassee Fl. 32399 Phone: 650-"7-1824
The State of Florida Is an AA/EEO employer. C°nvrioht 2007-2013 state of Florida.:: Privacy Statement :: AccesslhlliN Statement :: Refund Statement
Under Florida law, emall addresses are public records. If you do not want your e-mall address released in response to a publlrrecords request, do not send electronic
hftps://www.floddabuilding.orgfpr/pr�_app_00.aspx?param --wGEVXQwtDqtvOROQk7A5REBEOqzlUdi7ntuFlu2jC5s%3d 2/3
1/9/2018 Florida 13'uilding Cade Online
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emalls provided may be used forof clal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, RS.,
please dick }ffL.
Product Approval Accepts:
i
Credit Card
Safe
httpslwww.floridabuilding.org/pr/pr app dtl.aspx7param=wGEVXQwtDgtvOROQkZA5RE8EOgziUdl7ntuFlu2jC5s%3d 3/3
I
'I
it
I
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
1 '29 GA. 5V PANEL'
OVER WOOD SUPPORTS.
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 9555.1-R4
STRUCTURAL COMPONENTS
ROOF DECK
Prepared For:
Union Corrugating Company
P. O. Box 229
Fayetteville, NC 28302
Telephone: (910) 483-0479
Fax: (910) 483-8897
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Report No. C2172-1
Date:-8 20.2017
FL 9555.1-R4
C2172-1
8.20.2017
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24" wide coverage with (5)1/2" high ribs
Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755). '
Support Description: Nom. 11" x 4" (min) lumber (Southern Yellow Pine Untreated)
(Must be designed by others)
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 70.25 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) (3 or more spans)
Panel Attachment: #9-15 or #10-14 x 1-1/2" long wood screws with washer
At panel ends @ 12"' o.c. across panel width
At intermediate @ 12 o.c. across panel width
Test Standards: Roof ;assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural Performance of Sheet Metal Roof and Siding
Systems by Uniform Static Air Pressure Difference' and FM 4470
Section 5.5 `Resistance to Foot Traffic'.
Test Equivalency: The test procedure in ASTM E1592-01 comply with test procedure
prescribed in ASTM E1592-05(2012).
The test procedure in FM 4470 (1992) comply with test procedure
prescribed in FM 4470 (2012).
Code Compliance: The product described herein has demonstrated compliance with FBC
2017' Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017, Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer. This product is not approved for use in the High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
approved roofing materials directory for fire ratings of this product.
. . a
FL 9555.1-R4
C2172-1
8.20.2017
Page 3 of 3
Supporting Documents: ASTM E1592 Test Report
Farabaugh Engineering and Testing Inc
Project No. T246-06, Revised Reporting Date 11/7/06
FM 4470 Test Report
ENCON Technology Inc
C1583-3, Reporting Date 7/24/08
PANEL FASTENER
#9-15 OR #10-14 X 1.5" LONG WOOD
SCREWS O MAX 12" O.C.
FASTENER PATTERN
SUPPORT SPACING = 24" O.C.
ALLOWABLE UPLIFT PRESSURE = 70.25 PSF
NOM. 1 " X 4" (MIN)
SYP UNTREATED
(DESIGN BY OTHERS)
12'
1/2T
24'
5V Panel Profile
Minimum 29 Gouge, Minimum Yield - 60 KSI
H
0
m
fai