REVISION
Compliant with Florida Building Code 2017 (6 Compliant with Florida Product Approval Ruh e Compliant: Keystone Certifications I Product: 5 V Crimp 2 GA Steel Roof Panel FBC Yield strength: 50 ksi rain.; Attached Deck w/ min. 0.42 specific gravity wi Rib Height 3/8" I Corrosion Resistant Compliant: FBC Sec.1507 Fastener 1(Method 1 Attachment): #9 x 1-1/ 3/16" min. thru deck or 5/8" embedment into requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 penetrate 3/16" min. thru deck or 5/8" embe( to meet requirements) Underlayment: To be compliant with FBC Sec. wit Slope: Shall be in compliance with FBC Sec. Palm City, FL 34990 ed.) C # 61G20-3 L—RECEIVED N 14 2018County, 0. Permittir•,, { Sec.1507.4.2 to min.15/32" plywood or Wood .4.3 2" Hex -Washer Head wood screw* to penetrate o wood plank. (*or sufficient length to meet x 1-1/2" Hex -Washer Head wood screw* to ment into wood plank. (*or sufficient length 1507.1.1 Fasteneyat zwfiment specifications above Install Details: Table_A Allowable Loads. METHOD i - _METHOD 2 METHOD 3 _,,,.,,_METHOD 4 DESIGN PRESSURE* _ _ _ - _ _ _- . , -86 PSF , -93.5 PSF -101 PSF_ _ —228 PSF ROW SPACING_._ - - - --- - — - - _ .r --16"o.c. - - - -16" oc. 8" O.C. - -- 6„ o.c. FASTENER_ SPACING, (ALONG_Panel width) , 120 o.c. _..12".o.c.. _ -_ . 12" o.c. 12" o.c. FASTENER SIZE #9 ; #10 #10 #10 Reference Data: ARCHITECTURALTESTING, INC. TST ID#:15 UL 580-06 & 1897-041 Test Report 100�893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897--04 is equivalent to test standard UL 1897-% r t *Design pressure margin of safety 2:1 Locke Bowden, P.E. does not have, not will acquire a financial intQT' under this evaluation. •`~ Locke Bowden, P.E. Is not owned, operated, or controlled by air coi report. _ rV .: y. �cgq�l'r4iafacturingor distributing products iart#PrnAdfs+rtureP, or distributing products under this SNTE s.� S►ON.A 0';��'' }` I 7 FL17022.1 5V Crirr',— 6GA Steel), 24" Wide Roof Pan'-.' IDetails u' ' Liry tions: 1/1 Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 1513T or greater Plywood, or Wood plank 24 318 l0Fn0 iali.sMATI Ns-� I I Panel Profile Nominal12" 1 Nominal12" O.C. i O.C. Fasten 99 x 1-1/2" Min. or #10 x 1-1/2" Min. per —fable "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Wdth Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or, - Wood plank i RECEIVED l ? M AMI-DADS COUNTY MIAM4 J U N 14 20 i BRDDUCT CONTROL SECTION 4 r 11805 W 26 Strcct, Room 208 DEPARTMENT OF REGULATORY AND ECONOMICRESOURCES (1fR)Lucie County, Permittin .Florida33175-2474 BOARD AND CODE ADMINISTRATION DIVISION I 7 -2590 F (78 6)315-2599 NOTICE OF ACCEPTANCE (NOA) „V,V'1V.111ianridade.e2vkc"°2M Interwrap, Inc. 32923 Mission Way Mission, BC, Canada V2V-6E SCOPE: REV This NOA is being issued under the applicable rules at documentation submitted has been reviewed and accep used in Miami Dade County and other areas where alk CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD regul$tibn,ove inguse Nc.traction materials. The d by Miami -Dade County RER - Product Control Section to be ed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur theexpense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicablel building code. This product is approved as described herein, and has including the High Velocity Hurricane Zone of the Fl, DESCRIPTION: Titanium® UD1-30 / Titanium® and UDIrMD (2 ply) / Titanium LABELING: Each unit shall bear a permanent label statement: "Miami -Dade County Product Control Apl n designed to comply with the Florida Building Code a Building Code. SU-30, T to '9 UDL:25 PLUS"/ itanium® PSU-30, PSU-30 Underlayment System the manufacturer's name or logo, city, state and following 1", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the plerformance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal If NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 13-0730.01 and co Isists of pages 1 through 7. COPY The submitted documentation was reviewed by Alex Trgera. , FILE i NOA No.: 14-0603.19 MIAMI•DADECOUNTY ` _ Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 1 of 7 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR`COMPLIANC�i!ZJ� DATE THESE PLANS AND ALL PROPOSED WORK PLANS AND PE M T MUST BE KEPT ]OB ARE SUBJECT TO ANY CORRECTIONS SITE OR NO INSPECTION(S) WILL BE MADE REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. ROOFING COMPONENT APPROVAL Category- Roofing Sub -Category: Underlayment Material: Polypropylene TRADE NAMES OF PRODUCTS MANUF Product Dimensions Manufactuting Location #1& #2 UDL-MD (2Ply system) 48" x 250' rolls Manufactuting Location #2 Titanium® UDL-30 48" x 250' rolls Manufactuting Location #1& #2 Titanium® PSU-30 36" x 72' rolls Manufacturing Location #3 MANUFACTURING LOCATIONS: 1. ML1 2. ML3 3. MIA MIAMI•DADE COUNTY URED BY APPLICANT TABLE 1 Test Product Description ' D226 Woven synthetic polymer underlayment with a I & H chemical slip resistant and UV protected coating on both sides. i D226 Woven synthetic polymer underlayment with two I & II sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. 103 Unreinforced polymer modified bitumen material adhered to the underside of a polymer -coated, synthetic woven sheet. The underside is backed with a release film. j NOA No.:14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Intertek Testing Services #3031783 TAS 104 02/19/03 3124826-01 ASTM E108 02/19/08 3119607COQ-003B ICC-ES AC48 02/20/08 3130639COQ-002A ASTM D226 02/20/08 312482696-007 ASTM E108 02/25/08 3146738COQ-003B ASTM D 1876/ TAS 117 03/28/08 3146738C Q-003A ASTM D226 04/22/08 Trinity ERD 135520.06.11 TAS 103 / TAS 104 06/15/11 I35520.06.11 TAS 103 /TAS 104 06/15/11 I38010.68.11 ASTM D226 08/11/11 I35520.08.11-1 TAS 114 08/12/11 I35520.08.11 ASTM D2523 / D1781 08/17/11 I44970.07:13-R1 ASTM D226, ASTM D1876 09/09/13 i i and TAS 114(C) MIAMI-DADE COUNTY NOA No.: 14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 3 of 7 i III APPROVED TITANIUM UNDERLAYMENT'SYSTEM ASSEMBLIES: Deck Type 1: Wood Deck Description: 11132" or greater plywood or Wood plank System E(1): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. All General and System Limitations shall apply. noted;belbwe;:� ^' - r-,ism1- IaN� Note ` tani:rin® UDL-30 shall be inverted to provide a smoohi bonding;u, ace. Primer is not required when 77taniui @ UDL-30 is installed inverted (printed side facing down) Fastening: Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8" o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet. Primer: MetaUTin caps shall be primed with ASTM D41 primer i Ply Sheet: (Optional) Titanium(M PSTI,30, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. I Membrane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Place the first6urse of Titanium&PSU-30 parallel to the eave and field, using a heavy pressure roller under safe conditions to further secure the membrane. Surfacing: Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow TILE BOND Roof Tile Adhesive. NOA No.:14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 4 of 7 Deck Type 1: Wood Deck Description: 1 132" or greater plywood or wood plank System E (2): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. All General and System Limitations shall apply. Base sheet: One or more plies Titanium® UDL-30 applied with minimum 4" horizontal laps and minimum 6" vertical laps and mechanically fastened as noted below. Fastening: i Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8" o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet. Primer: Titanium® UDL-30 shall be primed on the printed side with ASTM D41 primer prior to placement of cap sheet. Ply Sheet: (Optional) Titanium® PSUIi 30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: I Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" . vertical laps. Place the frsticourse of Titanium® PSU-30 parallel to the eave, using a heavy pressure roller under safe coinditions to further secure the membrane. Surfacing: Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. Note: I For file roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For foam -on tile roof assemblies,1 approved use with ICP Adhesives Polyset AH-160 and Dow TILE BOND Roof Tile Adhesive. I I MIAMI•DADE COUNTY NOA No.: 14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 5 of 7 � � I Deck Type 1: Wood Deck Description: 19/32" or greater plywood or wood plank System E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. All General and System Limitations shall apply. - Base sheet: One or more plies of UDL-MD (2Ply system) applied with minimum 4" horizontal laps and minimum 6" vertical laps and mechanically fastened as noted below. Fastening: Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8" o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet. �I Ply Sheet: (Optional) Titanium® PSU-30, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: I Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Place the fast course of Titanium® PSU-30 parallel to the eave and field, using a heavy pressure roller under safe conditions to further secure the membrane. Surfacing: Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the file manufacturer's NOA. For foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow TILE BOND Roof Tile Adhesive. NOA No.: 14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 6 of 7 4 1\ . BUILDING PERMIT REQUIREMENTS Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Titanium Synthetic Underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 4. Titanium® UDL-25 PLUS / Titanium® PSU-30, Titanium® UDL-30 / Titanium® PSU-30, UDL -MD (2Ply system) / Titanium® PSU-30 two-ply underlayment system, may be used in asphalt shingle, mechanically fastened roof tile, foam-on'roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. 5. The standard maximum roof pitch for the Titanium© UDL-25 PLUS / Titanium® PSU-30, Titanium® UDL-30 / Titanium® PSU-30, UDL-MD (2Ply system) / Titanium® PSU-30 two-ply underlayment system shall be 5:12 for flat tiles and 6:12 on profiled tiles with lugs. For flat tile applications at slopes exceeding 5:12, flat tiles shall be staged 2 base tiles perpendicular to slope behind a mechanically attached batten or toe board with maximum 7 tiles high on the slope atop base tiles (Total of stack not to exceed 9 tiles). At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the roof tile. 6. Titanium Synthetic Underlayments shall not be applied over an existing roof membrane as a recover system. 7. Titanium® UDL-30 / Titanium© PSU-30, Titanium® UDL-25 PLUS / Titanium® PSU-30, UDL-MD (2Ply system) / Titanium® PSU-30 two-ply underliayment system shall not be left exposed as a temporary roof for longer than 90 days of application. S. Titanium Synthetic Underlayments are components used in roof system assemblies. Roof system assemblies are approved under a specific Notice of Acceptance. Refer to Prepared Roofing System Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 9. Titanium Synthetic Underlayments may be used with any approved roof covering Notice of Acceptance listing Titanium Synthetic Underlayments as a component part of an assembly in the Notice of Acceptance. If Titanium Synthetic Underlayments are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami Dade I County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE NOA No.:14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 7 of 7