HomeMy WebLinkAboutALUMINUM ROOF OVER PLANA24 ALUM F
r RIDGED POLYSTYRENE INSULATION
EXISTING MOBILE HOME ROOF-7
2X3 P.T. WI#W' W.§. ®9' U,
INTO EXISTING COACH FRAMI
o
EXISTING COACH
FRAME
UDEO ALUM. ATTACH RAIL
w/N8X11/4 S.M.S. 3' O.C.
BUM RUBBER SEAL
024 ALUM FLASHING
9UTYLRUBBERSEAL
V
ED ALUM- ATTACH RAIL
w/N8X1114S.MS.3'O.C.
21 ALUA ROOF
1 I .024 ALUM F
r RIDGED POgYSTYRENE INSULATION
/ EXISTING PATIO ROOF -7
2X1 P.T. WMW' W.S. ® 8' O.C.
2X3 P.T. BLOCKS CUT TO FIT INP
PANS w/0) SB S.M.S. PER PAN
\—iMSTING PATIO ROOF
"EXISTING WALL CHANNEL
ALTERNATE COACH & PATIO ROOF ATTACHMENT #1 ALTERNATE PATIO PAN
CONNECTION DETAIL(NTS) (NO41h WALL) . N.T.S.
.024 ALUM ROOF.
r FUDGED POLYSTYRENE INSULATION
EXISTING MOBILE HOME ROOF EXTRUDED ALUM. ATTACH RAIL
wl 88X11N S.M.S. 3' O.C.
i BUM RUBBER SEAL
.024'ALUM ROOF FLASHING
uDED1 / /
114 ATTACH RAIL
w/N8X11/4 SAI S.MS.3.O.C.
2X3 P.T. W/ N8X3' W.S. @ B' O.C. BUM RUBBER SEAL
INTO EXISTING ROOF FRAME 024 ALUM ROOF
30# FELT ON TOP OF
' . PANS.,
2X3 P.T. BLOCKS CUT TO FTTINTO
PANS w/M#8S.M.S.PER PAN
EXISTING PAWS w/
EXISTING COACH INSULATION INSERTS
FRAME EXISTING ALUM.
COL & BEAM
.024 ALUM
309 FELT ON TOP OF. -
PANS
EXISTING PANS W'
INSULATION INSERTS
2X3 P.T. BLOCKS CUT TO FIT INT
PANS w/ (2) 18 SAES: PER PAN
—EXTRUDED ALUM. ATTACH RAIL
024 ALUM i1'wiiONT.OVER
wl#8X11/4 SAI.S. T O,C.
RIDGE W/ FACTORY SEMIS @ 48' O.C.
FASCIA EDGE DETAIL OR
RUBBER
-BUTYL64ALUMFLAL
GUTTER EDGE DETAIL
.024ALUM FLASHING INTO PAN
��
\`
AND CAULK OR CONTINUE
;/
_________________
---------------=-------
FLASHING TO GUTTER
®L ---=----------
2#8 SMS wl NEOPRENE
(\ %
INSULATION
WASHERS TO TOP OF EACH R%
1
EXISTING
MOBILEHOMEROOF SINGLEVVbQNTSJ
ova
POLYSTYRENE
�`�NfTdUVJ�
C-TYPICAL ROOFSECTf0N
FOAM
EXISTINGALM.
N.T.S.
COL & BEAM INSERT EACH PAN
#8>C1%i STAINLESS STEEL HEX HEAD
ATTACHMENT DETAIL "A" . 2 FUDGED POLYSTYRENE INSULATION
EXISTING MOBILE HOME ROOF-,
EXTRUDED ALUM. ATTACH RAIL
wl#8X11/4S.M.S.3.O.C.
�RUBBBUTYL
ER 0244 ALUM FLASHING INTO PAN
AND CAULK OR CONTINUE .
FLASHING TO GUTTER ..
2X3 P.T. WI X
248SMSw/NEOPRENE
INTO EXISTING
WASHERS TO TOP OF EACH PAN .
OVERHANG
EXISTING ALUM: `POLYSTYRENE FO
COL & BEAM - INSERT EACH PAN
ALTERNATE PATIO PAN ROOF ATTACHMENT DETAIL "B"
N.T.S.
r BUTYLRUBBER
r RIDGED POLYSTYRENE INSULAn(
ALTERNATE COACH & PATIO ROOF ATTACHMENT #2 OVERLAPPING
F \
CONNECTION DETAIL (NTS) (w/ 4U� WALL) 024ALUMR(O
.024 ALUM ROOF
r RIDGED POLYSTYRENE INSULAT7//
EXISTING MOBILE HOME ROO
20 P.T.
INTO EX
EXTRUDED ALUM. ATTACH RAIL
wl#BX1114SALS.7O.C.
r-BUTYL RUBBER SEAL
r.024 ALUM ROOF
EXTRUDED ALUM ATTACH RAIL
wl#8X1 14S.M.S.ITO.C.
2X3 P.T. wl #w
W.S. @3' O.C.
COACH AND PATIO ROOF
CONNECTION DETAILS
FOAM INSULATION
/--.024 ALUM ROOF
PATIO ROOF
a FROM ATTACHMENT RAIL TO EXISTING
nfib l MOBILE HOME FRAME @ 5' O.C. MIN. 1r
INTO EXISTING FRAMING
rEXT UDEDALUMATTACH RAIL 11Bk1'WIDEBUMRUBBLRCONi. 3• s �
w1N8Xi 1N-,
M S.M.S. 3' O.C. .024 ROLL ALUMINUM
INSULATION
BUM RUBBER SEAL
ATTACH CONT. 2W P.T. TO EXISTING
MOBILE HOME FRAMING W10T WOOD
SCREWS ® SPACING TO STRAIGHTEN .
WOOD ONLY, IN LIEU OF FULL FRAMING
` ATTACHMENT PER DETAILS
`024 ALUM GUTTER .
-WI STRAPS @"O.C.
co
O
O
m
a 03
G 03
ttOo
~ w _ cc
m cm
N
t a
y cq
O Q.
tl
' NOIE:THISALTERNATE
O
IMYBEIk�T00MTIN
4.
OFIAAMNCi
NOTE THIS CXWrzCnON
MIAYBEUSEDATALL
-
.
COPNECTIONAWASAS
ALUMTECON ECT01
0
Z
lL
�
Q
O ..
�.
U
%%Y / S' STAINLESS STEEL
EXISTING COACH . �� SCREWS
0 � O.C. INTO.
FRAME EXISTING MOBILE HOME PRE -PUNCHED HOLES.
FRAMING & ROOFING
ALTERNATE ATTACHMENT RAIL FASTENING #1
GUTTER EDGE DETAIL N•T•S'
NT.S.' .024 GALVALUME CLEAT
RECEIVED ae• o.c.(TYP)
.024' ALUM
JUN 04 2018
ST. Lucie County, Permitting
024' ALUM
.024 ALUM ROD
r RIDGED POLYSTYRENE INSULATIO
EXISTING MOBILE HOME ROOF S77
DOSTING CENTER J
`EXISTING COACH FRAMING
CAP
DOUBLE WIDE RIDGE DETAIL
N.T.S.
BUM RUBBER SEAL
EXTRUDED Am ATTACH RAIL
r RIDGED POLYSTYRENE INSULATION
w/wL114 SALS.3.O.C.
OVERLAPPING��
.024 ALUM ROOF
P.T. WOODBLOCK°A -
#8X3' W.S. ® SPANNING
_ TO STRAIGHTEN WOOD ONLY
2X3 P.T. WI#BX
INTO EXISTING
EXISTING COACH --J L
FRAME EXISTING PATIO ROOF
MAX SPANI4'4•
TAPERED INSULATION AS REQUIRED
NG WALLCHANNEL
FOAM FILLER
ALTERNATE COACH & PATIO ROOF ATTACHMENT#3
EXISTING CENTER CAP NG COACH FRAMING
CONNECTION DETAIL (NTS) (NO DROP BETWEEN ROOFS)
DOUBLE WIDE RIDGE DETAIL
USING ALTERNATE #1 ATTACHMENT (NTS)
MOBILE HOME ALUMINUM ROOF OVER PLANFOR 185 MPH EXPOSURE C
EXISTING COACH -
FRAME
STYRENE-BUTADIENE
-EXTRUDED ALUM.
FACTORY SEAM DESIGN FOR RUBBER SEALANT
T O.C.ALUMINUM
w�#Bx11usA1s.3•.c.
ROOF COVERINGS• BETWEEN SHEEt & CLEAT
OVER SOLID ROOFS ONLY PRODUCT APPROVAL #FL5739
BUM RUBBER SEAL'
�
OVER ATTACHED STRUCTURES PRODUCT APPROVAL #FL 7570-RO
024 ALUM FASCIA
N.T.S. =
'ATADWENT PATIO ROOF
NOTES:
PROVIDE.024 FLASHING
1.) THIS DESIGN CONFORMSTO-THE'2017 FCORLDA BUILDING.CODE FORA
INTO PATIO ROOF (MIN n
WIN SMS @ 1r O.C. .. '
CATEGORY 11 BUILDING FOR WIND LOADING OF?185'MPH'EXPOSURE 0 AS
DETERMINED'BY"ASCE S TANDARD;7.
2.)'THIS•DESIGN CONFORMSTOrFLORIDA ST TUTE 15G2.0081 FOR
STING EXTRUDED WALL CHANNEL
MOBILEWANUFACTURED HOME REPAIR AND REMODELING.
3.) 'ALUMINUM ROOFING IS DESIGNED FOR USE OVER A SOLID ROOF ONLY. IT.
`
SHALL NOT BE USED AS A STRUCTURAL ROOF SYSTEM.
_
4.) THE ROOF COVERING SHALL NOT OVERHANG THE EXISTING ROOF.
5.) ENGINEER IS NOT RESPONSIBLE FOR STRUCTURAL INTEGRITY OF EXISTING '
ROOF. THE STRUCTURE OF THE EXISTING ROOF.SHOULD BE ABLE TO.
SUPPORT THE CONSTRUCTION LOADING FOR THE NEW ROOF SYSTEM.
�cA L+I�I]�CT1/+ TA I{ 6.) MAXIMUM WIDTH OF A SINGLE WIDE MOBILE HOME NOT TO EXCEED 14'-0.
�I -S /1 EDGE_DETA L 7.) MAXIMUM WIDTH OF A DOUBLE WIDE MOBILE HOME NOT TO EXCEED 29.0
N.T.S. 8.) INSULATION TO BE POLYSTYRENE FORM APROX. DENSITY 1# PER S.F.
9.) MAXIMUM HEIGHT OF MOBILE HOME NOY TO EXCEED 15'4•.
10.) MINIMUM THICKNESS OF ALL ROOF FLASHING TO BE .024 ALUM.
11.) THE R-VALUE OF THE 2• EPS INSULATION IS R=6.7,
SHEETNo.: S1 Of 2
OWNER � \ 2L_�� NOT VAL:IUUNtESS DATED
& SEALED WITH EMBOSSED
ADDRESS: O oa <ry_. L•V C_\ Q LEA Q ENGIN FJAL
CITY: {�-r, Q \ �G� STATE ZIP: 9 L_�c L III ��
Z cl
LOT# BLOCK# RANGE: DAMES BUSHOUSE, P.E. Y
PROFESSIONAL ENGINEER 20311 _
U
STATE OF FLORIDA
C3
�to
.to.•.
CQ
Ohl
m �
N m
to W
co c.
4
O
"�1 V to
r; N`Fc�
"V 0312
lrV�
'C O
to
1214
wOto
O
b
hq0
q
O
4
r-EXTRUDED ALUM. ATTACH RAIL
w/
024 ALUM ROOF a8X11/4 S.M.S. r O.C.
r RIDGED POLYSTYRENE BUM RUBBER SEAL
INSULATION ZV PTw//14WTEXSCREWS ® 8' O.C. THRU
_ BONDED PANEL INTO EXISTING BEAM
.024 ALUM FLASHING
EXTRUDED ALUM. ATTACH RAIL
w/18X11N S.M.S. T O.C.
UMRUBBERSEAL
3' MIN THICK.BONDED PANEL
—.024 ALUM FLASHING
NOTE:'
MAX 12 SPAN BONDED PANEL .
1' MAX O.H.
> . EXISTING ALUM.---,, EXISTING
COLLtBEAM / OVERHANG
OR FRAMING
BONDED PANEL ROOF EDGE DETAIL #2
N.T.S.
EXTRUDED ALUM. ATTACH
W/ #8X1 1/4 S.M.S. 3' O.C.
12'xl2x.024 ALUM CAP -7
BUM RUBBER SEAL
2'x4' PT CONT. w/ #8x3' WOOD SCREWSO.C. TO RIDGE BEAM & 1-98)W WOOD
SCREW TO EACH TRUSS
.024 ALUM ROOF 2' RIDGED POLYSTYRENE INSULATION
2'k4' WOOD TRUSS @
24'O.C. W/ 1/2SHEATHING RUDED ALUM. ATTACH RAIL
���3►� w/ #8X1 1/4 S.M.S. 3' O.C.
i
BUM RUBBER SEAL
00 00 SEE GUTTER S
FASCIA EDGE
DETAILS, S-1
j
2X4 P.T. w/ #8x3'WOOD SCREWS
MAX 28' WIDTH MAX 18' O.H.—� TOEACH TRUSS TAIL @ 2 C.
CONTINUOUS
2' FASCIA TYP,
PARK MODEL DETAIL A
N.T.S.
d
Z W
O
U
EXTRUDED ALUM. -ATTACH RAIL BUM RUBBER SEAL
w/ #BX1 1/4 S.M.S. 3' O.C. m
12'x12'x 024 ALUM CAP 2'k4' PT CONT. w/ 24W WOOD SCREWS TO EACH TRUSS �
LAP OF ROOF ROLL TO BE. ON q
DOWNWARD SIDE, _ y O m
\ - .024 ALUM ROOF 2' RIDGED POLYSTYRENE INSULATION fy M
03
2-x4' WOOD TRUSS (9§ol
1 eT 24'O.C. W/ 1/2' SHEATHING EXTRUDED ALUM. ATTACH RAIL w
21 W/ #8X1 1/4 S.M.S.' O.C. V
1 $4
BUM RUBBER SEAL
SEE GUTTER & FASCIA EDGEm
1 j DETAILS, s-1
to
i O 4
' 2z4 P.T. w/g8x3'WOOD SCREWS
MAX 14' WIDTH MAX 18' O.H. —+ I @ 12' O.C. TO FASCIAw/ 1-#W- �
TO EACH TRUSS TAIL @124'O.C.. v 1
CONTINUOUS
02' FASCIA TYP.
24 ALUM ROOF
PARK MODEL DETAIL B
r RIDGED POLYSTYRENE DEDALUM. ATTACHRAIL
INSULATION
wl#BXI IN S.M.S.3' O.C. N.T.S.
BUM RUBBER SEAL r , _rq q abD
024ALUM FLASHING
3' MIN THICK BONDED PANEL
2V PTw/#WV SMS ®4' INTO N
EXTRUDED METAL d BONDED PANEL
NOTE: -
MAX 17 SPAN BONDED PANEL / Oto
1' MAX O.H. `.032 EXTRUDED FASCIA
4
EXISTINGALUM. / EXISTING OR GUTTER 03 14 to
4 0o
COL & BEAM / OVERHANG SZ Of 2
OR FRAMING SHEET\\\\\\
OWNER NOT VALID UNLESS DATED
BONDED PANEL ROOF EDGE DETAIL #1 &SEALED WITH EMBOSSED a
ADDRESS: ENGINEEKS SEAL
N.T.S. CITY: STATE: ZIP:
Z 0
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C .. LOT# BLocic# RANGE: JAMESBUSHOUSE,P.E. 30 =
PROFESSIONAL ENGINEER2l)311 V
STATE OF FLORIDA