Loading...
HomeMy WebLinkAboutSOIL NUCLEAR GAUGE- - - - - - ---Soil-Nuclear Gauge - - G�� Report Date: 10/25/2018 NA'OoNPv Test Method: ASTM D 6938 Port St Lucie FBPE CA # 4930 607 NW Commodity Cove Port St. Lucie, FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Client: Paul Jacquin & Sons, Inc. 7348 Commercial Circle Fort Pierce, FL 34951 -- -- Project: - - - - - - -- -- .. 18-5750.00 Paul Jacquin & Sons, Inc 2018-2019 Master -� Agreement Various Locations FL 34948 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture (% In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 4 10/23/18 P-1 N/A 11.0 107.5 10.1 104.8 12 97 951105 Pass 5 10/23/18 P-1 N/A 11.0 107.5 10.3 104.7 12 97 95 / 105 Pass 6 1 1 10/23/18 1 P-1 N/A 11.0 1 107.5 10.3 1 104.8 12 1 97 1 95 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge . Make / Model / SN / Calibrated Field Technician 4 Below Slab Grade: 1013 Copenhaver Road, Ft Pierce - Foundation Pad, NW corner of pad 0-1 Troxler / 3430 / 24566 / Presson,.Thomas 5 Below Slab Grade: 1013 Copenhaver Road, Ft Pierce - Foundation Pad, SE comer of pad 0-1 Troxler 13430 / 24566 / Presson, Thomas 6 1 Below Slab Grade: 1013 Copenhaver Road, Ft Pierce - Foundation Pad, Center area 0-1 Troxler / 3430 / 24566 / Presson, Thomas Remarks I Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. IX o- OUP RECEIVED OCT 2 6 2018 ST. Lucie county, Permittin Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. CO �/ � W PS�OMINIC�j •,� � * : NN \146�,� � io I t ire # State%'�7' da • .�NAL Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Soil Nuclear Gauge Client: Project: Report Date: 10/25/2018 Paul Jacquin & Sons, Inc. 18-5750.00 '"�RNATONPv Test Method: ASTM D 6938 7348 Commercial Circle Paul Jacquin & Sons, Inc 2018-2019 Master { Port St. Lucle Fort Pierce, FL 34951 Agreement FBPECA#4930 Various Locations 607 NW Commodity Cove FL 34948 Port St. Lucie, FL 34986 Phone: 772-924-35751 Fax: 772-924-3580 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 1 10/4118 P-1 N/A 11.0 107.5 10.0 104.2 12 97 95 / 105 Pass 2 10/4/18 P-1 N/A 11.0 107.5 10.1 104.2 12 97 95 / 105 Pass 3 10/4/18 P-1 N/A 11.0 1 107.5 1 10.0 1 104.1 1 12 1 97 1 951105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1 Pad: 1013 Copenhaver Road, Ft Pierce - Prelim Foundation Pad, NW corner of pad 0-1 Troxler / 3430 124566 / Presson, Thomas 2 Pad: 1013 Copenhaver Road, Ft Pierce - Prelim Foundation Pad, SE comer of pad 0-1 Troxler / 3430 / 24566 / Presson, Thomas 3 Pad: 1013 Copenhaver Road, Ft Pierce - Prelim Foundation Pad, Center area 0-1 Troxler 13430 124566 / Presson, Thomas Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 1, 2, 3: 1-2, 2-3 HCP=40+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil. U RE ZEIVED OCT 2 5 2018 ST. Lucie Country, Permitting Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. DC)MIN/CM 2 O 8 � 60�— as Dominic Montalio _Z. �y�#�s'sion fiTtWgRfeer•# 46 ZONAL E Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1