Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GENERATOR
16/20/22 kW 1 ST.LUCIE COUNTY GENERAC PLAN REVIEW BLDG: GCAN LPATE: GUARDIAN® SERIES By �E Residential Standby Generators PLUMB: Air -Cooled Gas Engine INCLUDES: • True PowerT' Electrical Technology • Two Line LCD Multilingual Digital EvolutionTm Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available:, 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor DATE: DATE: Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz odeis G007043-0, G007042-0�(Aluminum_- Bisque).=22_IcW 60 Nz • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5%Total Harmonic Distortion for dilly quality power. This allows confident operation of sensitive electronic equipment and micre-chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: e PROTOTYPE TESTED . NEMA MG11-22 EVALUATION SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY c@us QUIET -EST. LISTED Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless other- wise directed by local codes. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state- of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component O GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. d f� w GENERAC JI1,76@,�j��-� �► m ©MObll,PROMISE Lin'4BRA�` 14 n +Bing In the USA using domes"o and famign parts. GENERAC® 16/20/22 kW features and benefits Engine • Generac (OHVI) design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • Quiet -Test- Greatly reduces sound output and fuel consumption during bi-weekly exercise. • "Spiny-lok" cast iron cylinder walls Rigid construction and added,durability provide long engine life. -Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. -Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator -Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. -Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. -Automatic voltage regulation Regulates the output voltage to -*1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch • Fully automatic Transfers your vital electrical loads to the energized source of power. -Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. •NEMA 3R Can be installed inside or outside for maximum flexibility. Evolution— Controls -Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. -Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. -Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. -Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. -Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. -Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger • Electronic governor Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Maintains constant 60 Hz frequency. Unit -SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. -Small, compact, attractive Makes for an easy, eye appealing installation, as close as 181 away from a building. Installation System • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. -Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. •Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 16/20/22 kW GENERAC® specifications Generator G007035-0,G007036-0, G007038.0,G007039-0 G007042-0,G007043-0 Model G007037 0 (16 kW) (20 kW) (22 kW) Maximum Continuous Power Capacity (NG) 16,000 Watts 18,000 Watts 19,500 Watts _Rated Rated Maximum Continuous Load Current 240 Volts (LP/NG) 66 6/66 6 83 3/75 91 6/81.3 T0���, ��0 fC'rt�tStt �'� ...{,;:�+, � ,.rs . E i� .:�'. r ��,r r� �. ' q �'�;` ". ,r, Via. , � _'�,r•'i;��,E�,.r�.� E f�aR.S.� .� Amp Main Line Circuit Breaker 70 A 100 1 p Amp 00 Am �f' �+-meI z'�w p, "�.� .tttzE u.. er'xy. H" "° µ .,: W°mh*,'�' { Ems'-...u, "'^` �y ah wui.` 1 ,.7' -3 wk'. e.��w�� '5i.,..,£ 4<¢Pt3d','tF.2`,<k.`�15.M'.i�,,��r�iA Number of Rotor Poles 2 2 2 4i`at��'"�.AkS fdatedfAFg1en E.L..u_r60� ,. zy Power Factor 1.0 1.0 1.0 E ; �,Ert�i4 .:: Unit Weight (Ib/kg) 448/203 466/211 d4409/186 �t7imlttrsrtrt�L=x�NGx1 #ifi/mttc_k`u.,,,Q.<i elf ?5C +. `ica.. a n.., �..._ _.� .e`3r._. ... -' •xtZ�""' �` �SE"iluSS' �.i-` Sound outout in dB(A) at 23 it (7 m) with generator operating at normal load" 66 66 67 Exercise duration 5 min 5 min 5 min Engine _. Hof Err e� �: u . n= _ ..s { ?f� ....., _tE ., emutsf€BAfr'.QHtVIUttL -u ; (N.iAQCitiNr CvENEBAC Q(�lfUA1fN Number of Cylinders 2 2 2 ptspla' Cviinder Block Aluminum w/ Cast Iron Sleeve Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Ratio 9.5:1 9.5:1 9.5:1 Oil Capacity Including Filter Approx 1.9 gl/1.8 L Approx 1.9 gl/1.8 L Approx 1.9 gl/1.8 L Fuel Consumption Natural Gas fta/ir (ma/hr) 1/2 Load 193 (5.47) 205 (5.8) 184 (5.21) Full Load 312 (8.83) 308 (8.72) 281 (7.96) Liquid Propane 0/hr (gal/hr) [I/hr] 1/2 Load 69 (1.9) (7.2] 81 (2.23) [8.45] 78 (2.16) [8.16] Full Load 116 (3.19) 1`12.071 140 (3.85) 1`14.571 134 (3.68) [13.9' Controls Made Buttons: Auto Automatic Start on Utility failure. 7 day exerciser. Off Stops unit. Power is removed. Control and charger still operate. ,amtrlVfese .�� .. Engine Run Hours Indication Standard ! Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) From 140-171 V/190-216 V �Es�Y�dale�;,ei:�2pabteSE7rerClSarExandSe:slet?E1rUli�anll 3 �,=�J,; z, �;� . EEs:,k', z.5.ei:�s r°, ..c;i 2,-.t� E;� �f•IF SE: z=:�-,, r.,`�`wx.{.rox=:-'.-'. Run/AlarnVMaintenance Logs 50 Events Each 4irr5tar65eyuer[ce=All _,'?. E, . c7 rex `. b'.. i ..,Iry...x..yci(acraNapOil set, . 7resL 4tLsearnaxiitiiuduratian) Starter Lock -cut Starter cannot re-engage until 5 sec after engine has stopped. =e�AEr-pp-r-ms'[:anm+n tBatt�1a(�en. Charger Faull/Missing AC Warning s Standard an.`WRhVGII...ttlUorr:rn.�.;�;._y,%`.. Automatic Voltage Regulation with Over and Under Voltage Protection Standard Etc-C1=Ffa /Qlf�fwilr.7te ..,©S�aiGURentr ratCEt(��.r.. P'.«: r 7 e 212£ u:.: :�sa�. •...1. .... _-... j])_._. ....con .vim E.....c...1 y� h sR2:&.a�i:4t�iL`'fsajxu .uc. &, 2i .o- t S.n� _e _.v��. !w".!_, fF. e._.v .,..._ e.3asy _. Safety Fused/Fuse Problem Protection Standard r a*� Wiz_ �-vs* aT9^ 'rs-+� ._ _ ` d 5 FF u` h.. h#4+ $ - kH tF 1 r putasr [aulaw.Olh..n sur tgir d`� Shutdown s /h. ., .. �.D-1""" 'I=..,: � _ OZA Overcrank/Oversoeed (@ 72 Hz)/rom Sense Loss Shutdown Standard Internal FaulUlnconect Wiring Protection Standard Field Upgradable Firmware Standard "Sound levels are taken ham the front of the generator. Sound levels tan from other sides of the generator may be higher depending on installation parameters. Rating dentitions - Standby. Applicable for supplying emergency power for the duration of the utility power outage. No overload capability Is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). ' Mardmum wattage and current are subject to and limited by such factors as fuel Blu/megaloule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 pementfor each 6 °C (10 `F) above 16 °C (60'F). h GENERAC® 16/20/22 kW switch options Limited Circuit Switch • 16 circuits, • Electrically operated, mechanically -held contacts for fast, positive connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effective install. Model GO07036-0 (16 kW) Current Rating (Amps) 100 oitag Ra O!}IC) C r.......... ... Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 65% Exercise bi-weekly for 12 minutes* Standard Total of Pre -wired Circuits 16 No. 15A120V 5 No. 20A120V 5 No. 20 A 240 V 1 No. 30 A 240 V - No. 40 A 240 V 1 No. 50 A 240 V 1 Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 10,000 *Function of Evolution Controller Exercise can be set to weekly or monthly Dimensions 200 Amps 120/240, ie W, a�a Open Transition Service Rated ' Height Width Depth ? Hi H2 W1 W2 F k In 2Z24 30.0 11.4 13.5 7.09 l mrr 692.0 762.4 289.0 343.0 1 180.0 Wire Ranges E Conductor Lug Neutral Lug Ground Lug 2/0-#14 2/0-#14 210-#14 o� �a Service Rated Smart Switch Features G007037-0 (15 kW)/G007039-0 (20 kW)/ • Includes Digital Power Management Technology standard (DPM). Model 0007043-0 (22 kW) • Intelligently manages up to four air conditioner loads with no z additional hardware. Current Rating (Amps) 200 • Up to four more large (240 VAC) loads can be managed when used in Utility Voltage Monitor (Fixed)* conjunction with Smart Management Modules (SMMs). -Pick-up 80% • Electrically operated, mechanically -held contacts for fast, clean Dropout 65% connections. tu'rrti tltil F5_ t „apt. 2sec„�, • Rated for all classes of load,100% equipment rated, both inductive and Exercise weekly for 12 minutes Standard resistive. It1L° 4dand T :' x :. s �. Stfi,,. f' Enclosure Type NEMA/UL 3R • Up to four more large (120/240 VAC) loads can be managed when used inRat)'s'" " 0„ conjunction with 50 amp Power Management Modules (PMM**). Lug Range 250 MCM - #6 • 2 pole, 250 VAC contactors. *Function of Evolution Controller • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Main contacts are silver plated or silver alloy to resist welding and sticking. Dimensions 200 Amps 120/240,1a Open Transition Service Rated Height H1 H2 Width W1 W2 Depth in 27.24 30.0 11.4 13.5 7.09 mm 692.0 762.4 289.0 343.0 1 180.0 W, r t fF U4 r H, Dean, I- W2 16/20/22 kW GENERAC® available accessories LiN�d�cc EMpt(u y,E . Generac's Mobile Link allows you to check the status of your generator from anywhere that you have G006463-3 Mobile Link- access to an Internet connection from a PC or any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). G007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0 F. G007103-0 Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch Contact The auxiliary transfer switch contact Idt allows the transfer switch to lock out a single large electrical Kit load you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers G007027-0 - Bisque (Standard on 22 kW) a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator. enclosure is scratched or damaged, it is important to touch-up the paint to protect G005703-0 - Bisque Paint Kit from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 -16, 20 & Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete 22 kW routine maintenance on a Generac automatic standby generator. Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to G006873-0 (50 Amps) increase Its power management capabilities. It provides additional power management flexibility not found in any other power management system. dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFr SIDE VIEW r48.erm FRONT VIEW Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 1 696471070385 G007039-0 696471070392 G007040-0 696471070408 G007042-0 696471070422 G007043-0 696471070439 GENERAC' Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI53189 • generac.com ©2016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 10000000194-B 05/18/16