HomeMy WebLinkAboutFIELD DENSITY TEST REPORTw
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
GCBY Phone: 772-807-9191 Fax: 772-807-9192
1� www.aaceinc.com
StLijejof E�D DENSITY TEST REPORT
PROJECT: 11820 West Midway Road
FILE NO: 17-131
St. Lucie County
REPORT NO: 1
REPORTED TO: Mr. Paul Tyson
CC:
DATE OF TEST(S): 05/02/2018
PAGE NO.:
1 OF 1
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
House Pad Fill
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
SEC of Pad
2613
10.0
111.0
95
+2' to +1' FS
2
SEC of Pad
2613
8.9
112.1
96
+1' to 0 FS
3
Center of Pad
2613
9.3
111.6
95
+2' to +1' FS
4
Center of Pad
2613
10.1
111.9
95
+1' to 0 FS
5
NWC of Pad
2613
9.2
111.3
95
+2' to +1' FS
6
NWC of Pad
2613
8.6
112.1
96
+1'to 0 FS
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: j— ASTM D-2937 ASTM D-2922 r ASTM D-2167
(— ASTM D-1556
TECHNICIAN: RL
REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING FS = FLOOR SLAB SUBGRADE
OPTIMUM
GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE
PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT
RS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
2613 D1557 117.2 PCF 8.8 %
SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
Peter G. Andersen, P.E.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
J
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone:772-807-9191 Fax:772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: 11820 West Midway Road
FILE NO: 17-131
St. Lucie County
REPORT NO: 2
REPORTED TO: Mr. Paul Tyson
CC:
DATE OF TEST(S): 07/27/2018
PAGE NO.:
1 OF 1
TEST NO.
House Pad Fill
MDR
NO.
MOISTURE
CONTENT %
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
15'N & 18'W of SEC of Pad
2567
12.0
110.0
95
+3' to +2' FS
2
36'N & 28'E of SWC of Pad
2567
10.0
111.1
96
+3' to +2' FS
3
22'S & 30'E of NWC of Pad
2567
9.0
109.5
95
+3' to +2' FS
4
10'S & TW of NEC of Pad
2567
10.5
111.6
97
+3' to +2' FS
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: r ASTM D-2937 F7 ASTM
D-2922 r ASTM D-2167
(— ASTM D-1556
TECHNICIAN: RL
REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING FS = FLOOR SLAB SUBGRADE
OPTIMUM
MDR NO. ASTM MAX. MOISTURE
TEST METHOD DENSITY CONTENT
GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
RS = ROADWAY NSSG = NON STABILIZED SUBGRADE
2567 D1557 115.5 PCF 11.2 %
SBP= SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
Peter G. Andersen, P.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDE� �SEN ANDRE CONSULT.�_ 1`3 ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone:772-807-9191 Fax:772-807-9192
www.aaceinc.com
MOISTURE -DENSITY RELATIONSHIPS
PROJECT: 11820 West Midway Road FILE NO: 17-131
St. Lucie County REPORT NO: 2
PERMIT NO:
REPORTED TO: Mr. Paul Tyson
SUMMARY OF TEST RESULTS
TEST METHOD:
• - - =
(STANDARD) (MODIFIED)
■■■■■■■■■■■■■■■��■■■■■■M
•
,.
MAXIMUM DRY DENSITY
■■■■■■■ram■■■■■■■■■�
��■■■�
■■■■■■■■■■■■■■■■■■
■►�■�
■■■■■■■■■■■■■■■■■■■■■■■E■M■■■■■■■_
■■■■■■■■■■■■■■■■■■■■■■■■■■■�■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■
■■■■■■\M\■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\■■■■■
.1■■■■■■■■■■■■■■■■■■■■■■■■■■■■■E\\\■■
SAMPLE NO: 2567 SAMPLE LOCATION:' Composite sample, import pad'fill
DESCRIPTION: Dark brown fine sand, traces of clay
DATE SAMPLED: 01/24/2018 BY: RL
DATE TESTED: 01/31/2018 BY: SM
Peter G. Andersen, P-E.
Fla. Reg.. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDS- 'SEN ANDRE CONSULT ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone:772-807-9191 Fax:772-807-9192
www.aaceinc.com
MOISTURE -DENSITY RELATIONSHIPS
PROJECT: 11820 West Midway Road FILE NO: 17-131
St. Lucie County REPORT NO: 3
PERMIT NO:
REPORTED TO: Mr. Paul Tyson
■■■■■■■■■■■■■■■V1■■■■■■E
SUMMARY
■■■■■■■■I
• •
.
MAXIMUM DRY DENSITY
'OPTIMUM WATER
■■■■■■■■■■■■■■■■■■■■■■�
■■■■■■■■■■■■■■■■■■■■����`-
42 .-
SAMPLE NO: 2613
SAMPLE LOCATION: Composite sample, import pad fill
DESCRIPTION: Dark brown to brown fine sands, traces of clay
DATE SAMPLED: 05/02/2018 BY: RL
DATE TESTED: 05/09/2018
BY: SM
Peter G. Andersen, P.E.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.