Loading...
HomeMy WebLinkAbout1508-0155 ENERGY EFFICIENCY CODEr- FORM`R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Piofessional Regulation - Residential Performance Method Project Name: Markee Residence I Builder Name: De La Hoz Builders Inc. Street: 4904 Seagrape Or Permit Office: St Lucie ��n®�a��n-�� City, State, Zip: Fort Pierce , FL , 34982 I Permit Number: Owner: Markee Residence I Jurisdiction; 611000 Design Location: FL, Fort Pierce 1 1. New construction or existing New (From Plans) 9. ! ypWti44_0 g I sul 'q Area 2. Single family or multiple family Single-family I G- n- to Bioc -int inset, xte-o-_ 1 44,00 W b. NIA ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (1285,0 sgft.) Insulation Area a. Under Attic (Vented) R=38.0 1285.00 ft2 6. Conditioned floor area above grade (ft�) 1285 b. NIA R= W Conditioned floor area below grade (W) 0 c, NIA R= ftz 11. Ducts R ft2 7. Windows(77.4 sgfQ Description Area a. Sup: Attic; Ret: Attic, AH: Main 6 257 a. U-Factor: Dbl, U=0.45 7�.42 ft7 SHGC: SHGC=0.22 b. U-Factor: N/A ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: NIA ft2 SHGC: 13. Heating systems kBtufhr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 16.0 COPA.00 SHGC.- Area Weighted Average Overhang Depth: 13.391 ft. Area Weighted Average SHGC: 0,220 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1285.0 sgft.) Insulation I Area EF: 0.980 a. Slab -On -Grade Ede Insulation R=0.0 1285,00 ft� 9 b. Conservation features b. NIA R= W None c. NIA R= ft 15. Credits CF, Pstat Total Proposed Modified Loads, 38.68, Glass/Floor Area: 0.060 ®AS C PASS Total Baseline Loads: 38.57 I hereby certify that the plans and specifications covered by Review of the plans and S t �ttr. rt 7C this calculation are in compliance with the Flori ner y Code. I specifications covered by this calculation indicates compliance with the Florida Energy Code. O �n ,,,, �. _ ti w '"�QO PREPARED BY: Before construction is completed .. DATE: this building will be inspected for V j compliance with Section 553.908 I hereby certify that this building, as .designed, is in compliance Florida Statutes. with the Florida Energy de. ..,' ) IC- �?� _� Op''1`v.1 .,�- OWNER/AGENT:- ._._ BUILDING OFFICIAL: _. _.,.__, _ _ ..,_ _ _,...._.___ __Y __. DATE: .. _.._ . __ ___......__w.._._. _-..r.......-...,._. DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Irisulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. i ' - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.000 Qn for whole house. 11112/2015 9:36 AM EnergydaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R4b5-2014 PROJECT Title: Markee Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1285 Lot # Owner: Markee Residence Tota� Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: De La Hoz Builders Inc. Rotate Angle: 0 Street: 4904 Seagrape Dr Permit Office: St Lucie Cro?s Ventilation: County: St. lucie Jurisdiction: 611000 Whole House Fan: City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34982 Nevi/Existing: New (From Plans) Comment: i CLIMATE / I IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST_LUCIE_CO_INI L 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1285 10280 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1285 10280 Yes 4 i 3 1 Yes Yes Yes I FLOORS j # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 168 ft 0 i 1285 ft= 0 0 1 j ROOF i Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor, Tested Tested Insul. (deg) 1 Hip Composition shingles 1392 ft' 0 ft' Medium 0.85 No 0.9 No 0 22.6 ATTIC J # Type Ventilation Vent Ratio (1 in) Area RBS IRCC +T�~+ 1 Full attic Vented 300 1285 ft' N � N CEILING i # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 38 1285 ft7 i 0.11 Wood 11 /12/2015 9:36 AM EnergyI Gauge® USA - FlaRes2014 Section R405A.1 Compliant Software Page 2 of 4 r FORM R40.5-2014. �, I WALLS / Adjacent i Cavity Width Height Space _ R-Value.-F..i�ln.m-_FC_._.In�._�__.Area...._ 1 N Exterior Concrete Block - Int Insul Main 5.1 40 8 Sheathing Framing Solar Below _13-Value_Eraction _Absor_Grade°/a._ 320.0 ft' 0 0.75 0 2 E Exterior Concrete Block - Int Insul Main 5.1 44 8 352.0 ft' 0 0.75 0 3 S 4 W Exterior Concrete Block > Int Insul main 1 Exterior Concrete Block : Int Insul Main 5.1 40 8 5.1 30 8 320.0 ft' 240.0 ft' 0 0.75 0 0.75 0 0 5 W Exterior Concrete Block - Int Insul Main 5,1 14 8 112.0 ft' 0 0.75 0 I DOORS # Ornt Door Type Spacer Storms U-Value Width Ft In Height Ft In Area 1 W Insulated Main None .4 3 6 8 20 ft' _._ 2 E Insulated Main I None A 3 6 8 20 ft' WINDOWS Orientation shown is the entered, Proposed orientation. j Wall O_mt ID Frame_ Panes N_ FRC U-Factor SHGC Area Overhang Depth_ Separation Int Shade_ Screening 1 2 3 _ E 2 Vinyl Low-E Double H Yes W 4 Vinyl Low-E Double Yes W 5 Vinyl Low-E Double Yei 0.45 0.22 17.2 ft' 0.45 0.22 34.3 ft' 0.45 0.22 13.5 ft' 2 ft 0 in V 1 ft0 in 2 ft 0 in 1 fi 0 in 10 ft 0 in 1 ft 0 in Drapesiblinds Drapes/blinds Drapesiblinds ~None None None 4 E 2 Vinyl Low-E Double Yes 0.45 0.22 12.5 ft' 2 ft 0 in 1 ft 0 in Drapesiblinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 + 1 Wholehouse - Proposed.ACH(50) ^.000254 856.7 47.03 88.45 .1855 5 HEATING SYSTEM _�.._ .-...--�. -_..• #� System Type Subtype _ Efficiency _ � Capacity Block Ducts _. 1 Electric Strip Meat! None COP-1 16 kBtu/hr ; sys#1 COOLING SYSTEM t f # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None I SEER: 16 24 kBtu/hr 720 efm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Main i 0.98 40 gal 60 gal 120 deg None 11/12/2015 9:36 AM I EnergyGauge(@iUSA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name iSystem Model # Collector Model # Area Volume FEF None None I ft2 DUCTS I Supply •— --- Retdrn --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location I Area Leakage Type TOT OUT QN RLF MHeat Cool 1 Attic 6 25707 Attic . 1 64.25 ft Proposed On RHandler Main -- cfm 0.0 cfm 0.00 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin Jan Feb jj Mar A r Ma X Jun X Jul X Au X Se Oct Nov Dec Heating Jan Feb IXI ] Mar IX �X� Apr May Jun Jul � LX� Jan Feb Xjj Mar Aug SepX� Oct�X NovX� DecVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78I 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78I 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68I 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 661 66 66 68 68 68 68 68 68 68 68 6868 68 68 68 68 68 68 66 66 11/12/2015 9:36 AM - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM, R405-2014 i r ENERGY PERFORMANCE •LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyP�rformance Index, the more efficient the home. 4004 Seagl 'rape Dr, Fort Pierce, FL', 34982 1. New construction or existing New (From Plas) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.1 1344.00 ft' b, NIA R= ft' 3. Number of units, if multiple family 1 I c., NIA R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? 10. Ceiling Types Insulation No a. Under Attic (Vented) R=38.0 Area 1285.00 ft' 6. Conditioned floor area ((12) 1285 b. NIA R= ft' 7. Windows" Description Areal c. NfA R a. U-Factor: Dbl, U=0.45 11 Ducts 77.42 ft' a. Sup: Attic, Ret: Attic, AH: Main R ft' 6 257 SHGC: SHGC=0.22 b. U-Factor: NIA ft' SHGC: 12, Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a. Central Unit 24.0 SEER:16.00 SHGC: d. U-Factor: NIA fF 13. Heating systems kBtu1hr Efficiency SHGC: a. Electric Strip Heat 16.0 COPA.00 Area Weighted Average Overhang Depth: 3.3 1 ft. Area Weighted Average SHGC: 0.220 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1285.00 ft' a. Electric EF: 0.98 b. NIA R= I ft' c. N/A R= b. Conservation features ft' None 15. Credits CF, Pstat I certify that this home has complied with the Flori Construction through the above energy saving fes in this home before final inspection. Otherwise, a based on installed Code compliant features. Builder Signature: Address of New Hom �vY fc-a cc a �r D Energy Efficiency Code for Building es which will be installed (or exceeded) w EPL Display Card will be completed Date: City/FL Zip:. 1::q py&eC . , C�3 Ot LQ WE 'Note: This is not a Building Energy Rating] If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site iat energygauge.com for information and a list of certified Raters. For information about the Florida Building Code ,l Energy Conservation, contact the Florida Building Commission's support staff. `Label required by Section R303.1.3 of the IFlorida Building Code, Energy Conservation, if not DEFAULT. 11/12/2015 9:38 AM EnergyGaugeO USA - RaRei2014 - Section R405.4.1 Compliant Software Page 1 of 1