Loading...
HomeMy WebLinkAbout1508-0155 SEWAGE CONSTRUCTIONIi i APPLICATION #:,AP 1198'966 STATE OF FLORIDA �� v PERMIT #:56-SF-1620893 DEPARTMENT OF HEALTH DOCUMENT #:FI1025042 ONSITE SEWAGE TREATMENT AN10*2" N119p�,,��AT,SSYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:,08/03/2015 FEE PAID:515.00 RECEIPT #:56-PID-2728467 /5-�g APPLICANT; Jose De La Hoz (De La Hoz Builders, Inc) � 6 16Y AGENT: De La Hoz Builders PROPERTY ADDRESS: 4904 Seagrape Or Fort Pierce, FL 34082 LOT: 10 SUBDIVISION: BLOCK: 42 Indian River Estates ID#: .3402-608.0126.000-8 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE�WITH STATUTE OR RULE AND MUST BE CORRECTED, TANK INSTALLATION I SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [21 [ ] [271 SURFACE WATER FT [ ] [02] TANK MATERIAL Polyethylene [ ) [281 DITCHES 7 FT [ ] [03] OUTLET DEVICE [ ] [291 PRIVATE WELLS FT [ ] [04] MULTI —CHAMBERED [ Y N ] I [ ] [301 PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-68 I [ ] [31] IRRIGATION WELLS FT [ ] [06] LEGEND 1. 70-143-11DC3 2. [ ] [321 POTABLE WATER 13 FT [ ] [071 WATERTIGHT I [ II ] (331 BUILDING FOUNDATIONS 5 FT [ ] (081 LEVEL [ ] [34] PROPERTY LINES 14 FT [ ] [09] DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION I FILLED / MOUND SYSTEM [ ] [101 AREA [1] 504 [21 SQFT II [ ] [36'] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER. OF DRAINLINES 4. 6.00 2. i [ ] [381 SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 12/21/2615 [ ] [141 DRAiNLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 6.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION I [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PIIMPS [ ] 142] ALARMS [ ] [19] AGGREGATE SIZE I [ ] [431 MAINTENANCE AGREEMENT [ ] (201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] 1211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [471 CONTRACTOR Mike Spears (All County Sep [ ] [22] FILL AMOUNT I [ ] [481 OTHER INFILTRATOR Quick4 E036 (single [ ] [231 FILL TEXTURE [ ) [241 EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED 6 FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / DISAPPROVED ]: FINAL SYSTEM [ APpROVED / DISAPPROVED ]; (Explanation of Violations on following page) St. Lucie CHD DATE: 11/12/2015 St. Lucie CHD DATE: 12/21/2015 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1198966 EID1620893 RECEIVED DEO-2 lffi Page 2 of 3 Violation Number STATE OF FLORIDA DEPARTMENT OF .HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION•AND FINAL APPROVAL Comment APPLICATION . # : AP1198966 PERMIT #:56-SF-1620893 DOCUMENT #:F11025042 DATE PAID:08/03/2015 FEE PAID::515.00 RECEIPT #:56-PID-2728467 Comments The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), fora total estimated flow of 300 gpd. No violations, system ok,to cover. Contractor notified by phone. Needs final inspection for stabilization and gutters. Final ok emailed contractor and SLC building dept i DE 4016, 08/09 (Obsoletes all previous editions which may not: be used) Incorporated: 64E-6.003., FAC I Page 2 of 3 EH Database v 1.0.1 AP1198966 EIb1620893