Loading...
HomeMy WebLinkAboutPROJECT SUMMARY 10-8-14Florida Energy Efficiency Code For Building Construction EnergyGau,ge Summit@, Fla/Com=2010, Effective Date: March 15, 2012 -- Form 50672010 Total Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc: Savanna Club Description: RT#1136 Savanna Club Owner: RaceTrac Addressl: 8639 US Highway I City: Port St. Lucie Address2: State: FL Zip: 34952 Type: Retail Class: New Finished building Jurisdiction: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) Conditioned Area: 4789 SF Conditioned & UnConditioned Area: 5928 SF No of Stories: I Area entered from Plans 5928 SF Permit No: 0 Max Tonnage 8.6 If Jiff nt, write in: I EnergyGauge Summit® Fla/Com-201 0. Section 506.4 Compliant Software. Effective Date: March 15, 2012 10/l/2014 r Page I of 8 Component \ Design Criteria Result Gross Energy Cost (in $) 3,518.0 5,147.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS PASSES PIPING SYSTEMS None Entered Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report ction 506.4 Compliant Software. Effective Date; Marc \15, 2012 Page EnergyGauge Summit®F4aICom 2010. Se2 of 8 I CERTIFICATIONS �I I I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: GTP Consulting Engineers Building Official: Date: 10 / 01 / 14 �i Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code i Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the'system design is in compliance with the Florida Energy Efficiency Code I Architect: Jeff Hill \ Reg No: 0017608 Electrical Designer; William Gaddy Reg No: 59723 Lighting Designer: William Gaddy Reg No: 59723 Mechanical Designer: Justin Tracy Reg No: 63377 Plumbing Designer: Justin Tracy Reg No: 63377 (") Signature is required where Florida Law requires design to be performed by registered design professionals. 10/1/2014 II I EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 i I I Page 3 of 8 Project: Savanna Club Title: RT #1136 Savanna Club Type: Retail l (WEA File: FL_ST_LUCIE_CO_INTL.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) LED 5 Entry Canopies I Yes 1.25 924.0 1,155 144 LED 13 Building facades (by li i ear foot) No 5.00 328.0 1,640 476 Tradable Surfaces: 144 (W) Allowance for Tradable: 1119.6 (W) PASSES All External Lighting: 620 (W) Complicance check includes a excess/Base allowance of 750.00(W) Project: Savanna Club I Title: RT #1136 Savanna Club Type: Retail (WEA File: FL ST LUCIE CO INTL.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ED (sq.ft) CP CP ance Sales Area 25,001 Sales Area 1,410 3 1 PASSES Yogurt 3 Storage & Warehouse - Bulky 200 2 1 PASSES Active Storage Womens 6 Toilet and Washroom II 252 1 1 PASSES Men's Restroom 6 Toilet and Washroom 297 1 1 PASSES Receiving 3 Storage & Warehouse - Bulky 740 2 1 PASSES Active Storage Sales Area 25,001 Sales Area �I 1,890 2 1 PASSES Freezer/Cooler 3 Storage & Warehouse - Bulky 171 1 1 PASSES Active Storage' Cooler 42 3 Storage & Warehouse - Bully 410 1 1 PASSES Active Storage Beer Vault 25,001 Sales Area 558 1 1 PASSES PASSES i EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 10/1/2014 Page 5 of 8 i t r Project: Savanna Club Title: RT #1136 Savanna Club Type: Retail (WEAFile: FL_ST_LUCIE_CO_INTL.tm3) System Report Compliance RTU-1 RTU-1 Constant Volume Packaged No. of Units �I System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 13.00 11.20 11.40 11.40 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.80 0.82 PASSES System -Supply Constant Volume I Air Distribution ADS System (Sup) 5.00 PASSES System (Sup) I RTU-2 RTU-2 I Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV - Criteria liance Cooling System Air Conditioners Air Cooled 13.00 11.20 11.40 11.40 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.80 0.82 PASSES System -Supply Constant Volume Air Distribution ADS System (Sup) 5.00 PASSES System (Sup) RTU-3 RTU-3 �I Constant Volume Packaged No. of Units System 1 Component Category I Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 15.00 12.23 8.00 PASSES < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - I 0.60 0.82 PASSES System -Supply Constant Volume Air Distribution ADS System (Sup) 5.00 PASSES System (Sup) I I EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 10/1/2014 1 - Page 6 of 8 • 3 f I PASSES I I Plant Compliance Description Installed No Size Design Min Design Min Category Eff Eff IPLV IPLV Comp liance None Project: Savanna Club Title: RT #1136 Savanna Club Type: Retail (WEA File: FL_ST_LUCIE CO INTL.tm3) Water Heater Compliance Description Type Design Min) Design Max Comp Category Eff Eff Loss Loss liance I Water Heater 1 Electric water heater <= 12 [kW] 1.00 0.90 I PASSES I � PASSES j Piping System Compliance Category Pipe I)ia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] I I f I I I None 10/1/2014 I f I I I EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 I. I Page 7of8 r 4 Project: Savanna Club Title: RT #1136 Savanna Club Type: Retail li (WEA File: FL_ST_LUCIE_C0_1NTL.tm3) Other Required Compliance I Category Section Requirement (write N/A in box if not applicable) Report 506.4.2 Input Report Print -Out from EnergyGauge F1aCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows & Doors 502.3.2 Joints/Cracks 502.3.3 Dropped Ceiling Cavity 502.3 HVAC Efficiency 503.2.3 HVAC Controls 503.2.4 Ventilation 503.2.5 ADS 503.2.7.5 HVAC Ducts 503.2.7 Balancing 503.2.9.1 Piping Insulation 503.2.8 Water Heaters 504 Swimming Pools 504.7 Motors 505.7.5 Lighting Controls 505.2, 502.3 Glazed swinging entrance & revolving doors: max. 1.0 cfm/ft2; all other products: 0.3 cfm/ft' Tol be caulked, gasketed, weather-stripped or otherwise sealed Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls Mm* imum efficiencies: Tables 503.2.3(1)-(8) Zone controls prevent reheat (exceptions); separate thermostatic control per zone; I Outdoor air supply & exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exlii aust air energy recovery required for cooling systems (Exceptions). Duct sizing and Design have, been performed Air ducts, fittings, mechanical equipment & plenum chambers shall be mechanically attached, sealed, insulated & installed per Table 503.2.7.2. Fan power limitations. HVAC distribution systems) tested & balanced. Report in construction documents. i HAO and service hot water. In accordance with Table 503.2.8. Perfolrmance requirements in accordance with Table 504.2. Heat trap required. Vapor -retardant or liquid cover or other means proven to reduce heat loss on heated pools; Time switch (exceptions); readily accessible on/off switch. Motor efficiency criteria have been met Automatic control required for interior lighting in buildings >5,000 s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluorescent lamps>30W I EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 10/1/2014 II Check Im Page 8 of 8 � a s i }�• 4 s r / � , EnergyGauge Summit® v4.10 INPUT DATA REPORT Proiect Information Project Name: Savanna Club Orientation: North Project Title: RT #1136 Savanna Club Building Type: Retail Address: 8639 US Highway 1, Building Classification: New Finished building— - - -- ---- - State: FL No.of Stories: 1 Zip: 34952 GrossArea: 5928 SF Owner: RaceTrac Zones No Acronym Description Type Area Multiplier Total Area rsf1 1Sn 1 PrOZol Zone 1 CONDITIONED 2159.0 1 2159.0 2 PrOZo2 Zone 2 CONDITIONED 740.0 1 740.0 3 PrOZo3 Zone 3 CONDITIONED 1890.0 1 1890.0 4 PrOZo4 Zone 4 UNCONDITIONED 1139.0 1 1139.0 10/1/2014 EnergyGauge Summit® v4.10 1 e Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] IN [ft] plier [sf] [cf] In Zone: PrOZol 1 Sales Area Sales Area Sales Area 30.00 47.00 10.00 1 1410.0 14100.0 El 2 Yogurt Yogurt Storage & Warehouse - 20.00 10.00 10.00 1 200.0 2000.0 Bulky Active Storage 3 Womens Womens Toilet and Washroom 18.00 14.00 10.00 1 252.0 2520.0 4 Men's Restroom Men's Restroom Toilet and Washroom 19.80 15.00 10.00 1 297.0 2970.0 In Zone: PrOZo2 1 Receiving Receiving Storage & Warehouse - 20.00 37.00 10.00 1 740.0 7400.0 FJ Bulky Active Storage In Zone: PrOZo3 - -- -- 1 Sales Area Sales Area Sales Area 30.00 63.00 10.00 -1- 1890.0 18900.0 In Zone: PrOZo4 - _. 1 -Freezer/Cooler Freezer/Cooler Storage & Warehouse - 9.00 19.00 10.00 1 171.0 1710.0 El Bulky Active Storage 2. Cooler #2 Cooler #2 Storage & Warehouse - 41.00 10.00 10.00 1 410.0 4100.0 El Bulky Active -Storage 3 Beer Vault Beer Vault Sales Area 15.08 37.00 10.00 1 558.0 5579.6 El Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Sales Area 1 LED General Lighting 9 55 495 Manual On/Off 1 2 LED General Lighting 28 12 336 Manual On/Off 1 3 LED General Lighting 3 44 132 Manual On/Off 1 In Space: Yogurt 10/1/2014 EnergyGauge Summit® 0.10 2 I LED General Lighting 1 44 44 Occupancy sensor without 1 ❑ Daylighting 2 LED General Lighting 2 55 110 Occupancy sensor without 1 ❑ Daylighting In Space: Womens 1 LED General Lighting • 10 11 110 Occupancy sensor without 1 ❑ Daylighting In Space: Men's Restroom 1 LED General Lighting 11 12 132 Occupancy sensor without 1 ❑ Daylighting In Zone: PrOZo2 In Space: Receiving 1 LED General Lighting 4 55 220 'Manual On/Off 1 ❑ 2 LED General Lighting 2 44 88 Manual On/Off 1 ❑ In Zone: PrOZo3 In Space: Sales Area 1 LED General Lighting 14 55 770 Manual On/Off — 0 2 LED General Lighting 41 492 Manual On/Off 1 ❑ 3---L-ED ----- - General Lighting 4 44 176 Manual On/Off 1 ❑ In Zone: PrOZo4 In Space: Freezer/Cooler 1 Compact Fluorescent General Lighting 2 54 108 Manual On/Off 1 ❑ In Space: Cooler #2 1 LED General Lighting 7 17 119 Manual On/Off 1 ❑ In Space: Beer Vault 1 LED General Lighting 20 17 340 Occupancy sensor without 1 ❑ Daylighting Walls No Description Type Width H (Effec) Multi Area Direction Conductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [Ib/cf] [h.sf.F/Btu] [Btu/sf.F[ In Zone: PrOZol 1 Side Entry Main Entry Wall 52.50 20.00 1 1050.0 East 0.0522 0.225 2.36 19.2 ❑ (East Wall) 10/1/2014 EnergyGauge Summit® v4.10 3 • • M l • e e • 2 No Entrances or Main Entry Wall 52.50 20.00 1 1050.0 West 0.0522 0.225 2.36 19.2 ❑ Windows (East Wall) 3 Front Entry Main Entry Wall 115.50 21.50 1 2483.3 South 0.0522 0.225 2.36 19.2 ❑ (East Wall) 4 Rear Wall with Service Main Entry Wall 115.50 20.00 1 2310.0 North 0.0522 0.225 2.36 19.2 ❑ Entry (East Wall) Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [sf] In Zone: PrOZol In Wall: Front Entry Wall 1 Front Entry User Defined Yes 0.2600 0.27 0.64 16.00 7.00 1 112.0 ❑ Storefront 2 Front Storefronts User Defined Yes 0.2600 0.27 0.64 15.30 9.25 1 141.5 ❑ at either side of main entrance- 3 Front Entry User Defined----- Yes - 0.2600 0.27 0.64 16.00 6.50 1 104.0 ❑ _- - - -- - -Storefront In Wall: Side Entry Wall 1 Restroom Transom User Defined Yes 0.2600 0.27 0.64 10.00 2.25 2 45.0 2 Side Entry . User Defined Yes 0.2600 0.27 0.64 8.66 7.00 1 60.6 8 Sidelight 3 Side Entry Over User Defined Yes 0.2600 0.27 0.64 8.66 3.66 1 31.7 ❑ Door Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf• F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: PrOZol In Wall: Service Entry Wall 1 Rear/Service Door Hollow Metal No 3.50 7.00 2 24.5 0.6000 24.90 2.89 1.67 ❑ Insulated Door 10/1/2014 EnergyGauge Summit© v4.10 4 Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value ` [ft] A plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol 1 Roof Roof with rigid 115.50 52.50 1 6063.8 0.00 0.0500 0.57 5.70 20.0 ❑ insulation and 40 mil durolast membrane Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area TotalArea [Btu/hr sf F] IN [ft] [Sf] [Sf] In Zone: - In Roof: ----- — —_� --- --- ---- Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol 1 4" Concrete Slab 4" Concrete Slab 115.50 52.50 1 6063.8 3.0030 9.32 140.00 0.33 ❑ Systems RTU-1 RTU-1 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 92000.00 13.00 11.40 ❑ 69000.00 1.00 ❑ 10/1/2014 EnergyGauge Summit© v4.10 3 Air Handling System -Supply 4 Air Distribution System (Sup) 3000.00 0.80 5.00 ❑ ❑ RTU-2 RTU-2 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 3 Air Handling System -Supply 4 Air Distribution System (Sup) 103000.00 69000.00 3400.00 13.00 1.00 0.80 5.00 11.40 ❑ ❑ RTU-3 RTU-3 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System ---_3_— Air -Handling -System =Supply 4 Air Distribution System (Sup) 49930.00 _—_ _30700.00--- --- 1600.00 15.00 —1-00 v 0.60 5.00 8.00 --�—Q ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV El Water Heaters W-Heater Description Capacity Cap.Unit I/P Rt. Efficiency Loss 1 Electric water heater 50 [Gal] 9 [kW] 1.0000 [Ef] 10/1/2014 EnergyGauge Summit© v4.10 6 Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sVft/No] [W] 1 LED 5 Entry Canopies 12 12 924.00 Photo Sensor control 144.00 ❑ 2 LED 13 Building facades (by linear 7 68 328.00 Photo Sensor control 476.00 ❑ foot) Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sf.F] [in] [in] --- - - - ❑ - --- ----- - -- --- _ _ -- -- - Fenestration Used Name Glass Type No. of Glass SHGC VLT Conductance Panes [Btu/h.sf.F] Restroom User Defined 2 0.2600 0.2700 0.6400 ❑ Transom Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.FBtu] IN [Btu/h.ft.F] [Ib/cf] [Btu/lb.F] 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 Lj 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 1003 ApLbMat1003 R-19 Generic Insulation No 19.0000 0.4147 0.0218 0.30 0.2000 ❑ 10/1/2014 EnergyGauge Summit® v4.10 7 1006 ApLbMat1006 4 in. Heavyweight concrete No 0.3330 0.3330 1.0000 140.00 0.2000 ❑ Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.Fl [Btu/sf.F] [lb/cfl [h.sf.FBtu] 1064 Main Entry Wall (East Wall) No No 0.05 0.22 2.36 19:2 ❑ Layer Material Material Thickness Framing No. IN Factor 1 267 0.75" stucco 0.0625 0.000 ❑ 2 1003 R-19 Generic Insulation 0.4147 0.000 ❑ No Name Simple Massless _ Conductance Heat Capacity Density RValue .-------Construct ---Construct--- —[Btu/h;sf.F] —[Btu/sf.F] -- [lb/cf]— [h—ssf.FBtu]- 1065 Roof with rigid insulation and 40 mil durolast No No 0.05 0.57 5.70 20.0 ❑ membrane Layer Material Material Thickness Framing No. IN Factor 1 23 6 in. Insulation 0.5000 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.Fl [lb/cf] [h.sf.F/]Btul 1066 4" Concrete Slab No No 3.00 9.32 140.00 0.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 1006 4 in. Heavyweight concrete 0.3330 0.000 ` ❑ 10/1/2014 EnergyGauge Summit® v4.10 8 v No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/ci7 [h.sf.FBtu] 1067 Hollow Metal Insulated Door Yes No 0.60 2.89 24.90 1.7 ❑ B • �1- i E i ti•• iv• . .5 3 No. 3 ' • STAT _ ATE O ' w i,��111NA' �� i,///ONAL1`\\��� � v 10/1/2014 EnergyGauge Summit® v4.10 9