Loading...
HomeMy WebLinkAbout22020536- ENERGY EFFICIENCY CODEWhole"Building Performance Method for Commercial Buildings_ Form 400A-97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-97 Version 2.2 NtL� (BYUCip PROJECT NAME ISLE CONDOS PERMITTING OFF t'rnmf -GRAND ADDRESS: 434 WEST LONGWOOD, FL 3275 Pierce _Fort CLIMATE ZONE: 6 OWNER: GROUP PERMIT NO: _JAYMOR /AGENT: JURISDICTION NO: 661100 B DING TYPE: _Hotel / Motel CO: TRUCTION CONDITION: New construction DE IGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: _113000 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 20 COMPLIANCE CALCULATION: METHOD A ----------------- A. WHOLE BUILDING PRESCRIPTIVE REQUIREMENTS: LIGHTING LIGHTING CONTROL REQUIREMENTS HVAC EQUIPMENT COOLING EQUIPMENT 1. EER IPLV 2. EER IPLV 3. EER IPLV 4. EER IPLV 5. EER IPLV I G. EER IPLV 7. EER IPLV 8. EER IPLV 9. EER IPLV f10. EER IPLV 11. EER _ IPLV 12.. EER IPLV 13 EER IPLV NUMBER OF ZONES: 13 DESIGN CRITERIA RESULT -------------- ------ 76.10 100.00 PASSES PASSES 11.60 9.30 PASSES 9.00 0.00 N/A 11.60 9.60 PASSES 9.00 9.00 PASSES 11.60 9.60 PASSES 9.00 9.00 PASSES 11.60 9.60 PASSES 9.00 9.00 PASSES 11.60 9.60 PASSES 9.00 9.OQ PASSES 11.60 9.60 PASSES 9.00, 9 . 0.0 PASSES 11.60 9.60 PASSES 9.00 9.0.Q PASSES 11.60 9.60 PASSES 9.00 9.00 PASSES 11.60 9.60 PASSES 9.00 9.00 PASSES 11.60 9.60 PASSES 9.00 9.00 PASSES 11.60 9.60 PASSES 9.00 9.00 PASSES 11.60 9.60 PASSES 9.00 9.00 PASSES 11.60 9.60 PASSES 9.00 9.00 PASSES HEATING EQUIPMENT 1. COP 2. COP 3. COP 4. COP 5. COP 6. COP 7. COP 8. COP 9. COP 10. COP 11. COP 12. COP 13 . COP IR DISTRIBUTION SYSTEM INSULATION ,,-1. Unconditioned Space 2. Conditioned Space 3. Conditioned Space 4. Conditioned Space 5. Conditioned Space 6. Conditioned Space 7. Conditioned Space 8. Conditioned Space 9. Conditioned Space 10. Conditioned Space 11. Conditioned Space 12. Conditioned Space 13. Conditioned Space REHEAT SYSTEM TYPES USED ELECTRICAL SYSTEM WATER HEATING EQUIPMENT PIPING INSULATION REQUIREMENTS COMPLIANCE CERTIFI I hereby certify specifications 'c, lation arp., in co, Florida E e PREP_�R DATE: ,/(/' h# the plans and ed by this calcu- iance with the iciency Code. 4.20 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 REQUIREMENTS 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 3.80 4.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 PASSES N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PASSES N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Review of the plans and specifica- tions covered by this calculation indicates compliance with the Florida Energy Efficiency Code. Before construction is completed, this building will be inspected for compliance in accordance with I hereby certify that this building is Section 553.908, Florida Statutes. in compliance with the a nergy BUILDING OFFICIAL: Efficiency Code. DATE: OWNER/AGENT: DATE: I by certify(*) that the system design is in compliance with the Florida En y Efficiency Code. SYSTEM DESIGNER REGISTRATION/STATE ARC ITECT �i E CHAN I CAL : n) iL ZE c7 IN 1.� � 9 ?LUMB ING • . * ,LECTRICAL : efV�-5 T _ ��a� _ 3z/ SIGHTING -a Signature is required where Florida law requires design to be performed t registered design professionals. Typed names and registration numbers may i be used where all relevant information is contained on signed/sealed plans. 0 W E-1 W P4 O a W W C7 z H A a H PQ I O O O 41 1 dl 1�44 00 44 1 1 cr2 I 1 rd 1 Ill 1 }4 1 g I II H I Ill r,' 1 0 N bpi i z z E•1 1 0 O i°4 > I I I U] m rd U i H H -I I I r-I �D I CO 00 O 1 r E-I I IOo W 1 I r-I ri 0 1 rd rd N I •rq rl 1 1 4-) 4-1 Z i ro rd H U) 1 •r•i -ri I I p I I -ri I 1 fd I •si r� 0 r-I 1 O O �vW I zU2 — 1 0 m m m m 4J 1 0(nN('M0) 1 rd I � 1 � t 1 II N 1 (ll 0 1 O N rd I O N N U2 OOOOHH co 1 z z z z H I o 00 0� I � U I ri r-I H H H Ul I I 0 i r-I rd EO4 I0000 W I I r-I r-i O 1 rd rd rd rd N I •ri •ri -H rl I 1 4-) 4, 4J 4J HI ZS 'd 'd rd N N I U2 U2 U2 U2 I Ei 1 Q) ill Q) Iv I4 Ix P ; P4 U I I � i I p 1 1 •rl I I 4-J I 1 rd I rcl r', ri N I �4 �w I ZPQM3 Y — I O In M M M I— I O M M M M 4J 1 0MNM(3) 1 4J 1 0MNM0) 44 1 i-•I r-i H H d+ 1 44 1 r-I r-i r-4 ri d+ b, I I V I rd I I rd I II r'M 1 Ill I I O I I~ I O rl t N I -rl I N rig I I rd I Q2 M 1 0 0 0 0.0 1 rd I I� m 1 zzZz I coAI zzzz (d I rd N I O a10000�iai0000p 54 1 I > I U2 I U? (<$ I cd U I r-I r-I H ri r-i I U I H H H H r-♦ in I I 0 I c I I 0 I rI I I I H rd 1 rd 41 1 .4J I0000 I I0000 I � I W I N 1 -r-i "I •ri -ri 1 1 4,4J4-)4-) N I U2 U2 U2 U2 Ea 1 Pi' Pa' R; io4 I I � I I p I I •rl 1 I 4-1 I I rd I •i� ,� • ,'> I 41 41 4.1 4-1 �W 1 zWUp13 W 1 N I •r1 -rl -H -H z 1brorob H N I -ri -ri -rl rl P aaaa 1 I � I I p I 1 -ri 1 I 4-1 t 1• > I 4�-1 4-) 4ro-1 41 pPIM� - w z 1 O m m m m 4J 1 0 M N M M 44 1 r-I r-I H H � 1 � 1 � 1 rd I � I �4 1 IC4 1 I � o ri I N rd OOOO�Hi �Izzzz� E� 1 0000�4 I 1 I U1 m I 1 H rd 1 O 00 00 00 o 1 t�rrrEa 1 0 0 0 0 W I 0 I I 4.J 4-) 4-) 4-) H 'd ro rd 'd (1)I 1 oLf1Ln�Lf1 LJ I OMNMOI bi i rl r♦ H ri dl n1 rd I CL) 1 �4 1 C4 1 I � bl I H I N ZZZZ'� I o 0 0 o 1 F4 > I I � I ri ri ri r-I r�-i n I I O 1 H m I aoOOO O I rr- r- r- E-+ 1 0 m w m m 4, 1 0 M N M M 41 rirlrlrlc2+ >n I �• I (d 1 � I I I I ill s~ I O ,I I N 0000-H �Izzzz(d Ei i 0000 N I U2 ul U I -I ri r-I ri r-i rrd � I I I � rd 4, 100000w p rt`rt`E-1 I0000 W I W o I rdrdrdrd 0 1 MM� a N I -r-I -ri -ri -ri N I -rI -H -ri -r-I I I 4J 4-) 4-) 4J 1 1 4-) 4-) 4-) 4Jvvvv �vvvv z 1rdrdrdrd z 1rordrdro H Q2 I -ri -ri -r-i -r-i H N I -ri -ri -ri -rI N I U2 Ul U2 U2 N I U2 U2 U2 U2 �E4 I IX104W'R4 �EH I Pi'R$P IX0 I � ' p i I O I I •ri I I •rI I I 4-1 I I � I -i 0 rd %(Quopol:I ri _1 0 0 rd 0 a) o ri t o rd o o rd o a) q+W I zWa13 .1+W zWU13 No (D N •I rr i N-' I 0 I 1 1 H W I I N z tij a H Ul F-� iJ �W Mt4 I w A :EMMz 1 wat.. :4MWZ I wIA (D w 0 0 0 0 W 0 1 po (D 0 Al 0 1 Imo Ul Ul F Fi Ul 0 Ul K 1 (D N N r- M Fj I N I- rr rr � � I rt � rr i � •I rr rr rt rr C I pl � i I rt' I I Ct I 1 rt I 1 I.a. I I F-�• I I Fes- I 1 I I (7] w 00 00 0u I y = 1 W W W W I IA IA IA IA I H H H H I 0000l I I I N N N N I H IA IA IA IA I rt 0 0 0 0 1 p 0 0 O 0 1 F-'\\\\ I ill Ul Ul Ul 1 $U o OD 00 0 I (D Al O000 I H-t, I' N I N I lj U, ul U, U1 I N P P H 1 cl N 0 1 I U] I I 11 IA IA A IP I �d I I hj I 0 I Ul I � I � I ��1 OJNNNN I Ft1 WIAfAO0 1 rt 00000 1 — ti N N (D (D I t1 Ul Ul Ul Ul I N (D (D (D (D U] Ul Ul Ul U� F-'- N• P- H- I (D H P- H- P- FJ- I I (D N H 1 aaaa1 z aaaai MOMMI G) 8 o rr rt rr rt I 1 rr rr rr trt I I z W H- P- F'- I N P- li- P- F'- I N p w p w 1 Z tit N I I 1 1 1 I w 1 I N I 1 I I 0 0 0 0 1 I 1 0 0 0 0 1 I I 1 H �l �7 �1 �l I I I l y �7 �] �7 J 1 I I I O 00 00 0 o I I 0 OD OD 00 0o I[ I 1 rt I rY 1 I I � I I 1 I I � I I I 1 I I 1 NNNFsH F-'F-INNP I (] I 1 to I m I I (n I I Ul I I I I I r i y 1 I r I l O Fi 0000 F1 0000 1 y I 1 Al (D I (D I pi 1~ z z z z I i z z z z 1 P. N 1 Ul 0 I r� 10 I I (D (D I I I I 1 I (D I Su w 1 I II II I 1 I I I I N II I I I I 1 I I I fi I (D I P) I I � dl I FQ N� W N W O I rt O Ul Ul Ul Ul O I I I h' 1 (D 1 ¢1 I 1 � 1 %D W N W 0 1 rt W W W W O I 0 0 P) 0 1 N o Ul C: Ul Fi I (D h-I rt rt rt rr I <4 I I 1 rat I I 0 I I � 1 1 N � H (�dD (�dD (�dD Ul Ul Ul U] I � N P- F1- P- P- I (D H m G) (aD caD caD rt i � cat cat rat W F•'- F'- Fes- I N �I SL �U Al l o N N N N I I LIJ - • • W H v v J v 0 00 o 00 0o I c" rt Al F� I �FJNNN I � n V2 m I I � 0o00iy �' zzzz 1 rn m cD rn cD I a 0 I (D I F-' I F� II I I mr�z IA I �, ,:V4wMz I WIA (D 0 P 0 1 FWI0 P 0 1 H0 Ul U] F 1 � 0 Ul fi I. (D P rr rtrt rt rr rt rt 1 C I cr. I I F'- I I H• I I 0 1 I 0 1 1 1 (D 1 U] Ul Ul Ul 1 N Ul Ul Ul m I N H- I (D H P- P- P- F'- I (D H aaaal z aaaal z G� 0 t3 ,J 0 I rr rr rr rt I I rr rr rr rt I I F' F' H. P. I N H- P- Fj- P- I N a1�UP)w 1 F✓NFJN I Z wPPw� Z I � I • • • H J J J J I 0 ow00o 1 C� rr Al FJ I � I pNNN�� N I I 1 (D0000 P' zzzz 1 m �a (D (D (D (D 1 a P. O 1 tj 0 1 W (D I H I O 1 0 0 0 0 1 H J v v J I 0 00 00 0o ao I C,- ct FJ 1 I I � () m U) I I 1 F1 0 0 0 0 1-3 P' t4 t4 1 0 I (D I 0 I I Fj 1 (D 1 ¢1 1 I U] I lDwww0 1 rr Ul Ul Ul Ul 0 1 m 0 0 0 rr rt. rt rt I I rr I F'- 1 0 I F3<<J< I 0 Wo000W 1 G rt Pi . I m Ul I I I r n 0000 1 y (D Fj- 0 0 0 O m N N N i� O 1 I Lq (D I --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 4 ----------- 1320 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1320 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 Total Wall Area in Zone 2 = 4656 402.-- ---- WALLS --ZONE 3 ------------------------------------------------ Elevation Type U Insul R Gross (Sgft) --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 4 ----------- 1320 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1320 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 Total Wall Area in Zone 3 = 4656 4 ------WALLS--ZONE 4------------------------------------------------ E ation Type U Insul R Gross(Sgft) --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 4 ----------- 1320 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1320 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 Total Wall Area in Zone 4 = 4656 402.------WALLS--ZONE 5 ------------------------------------------------ Elevation Type U Insul R Gross(Sgft) --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 4 ----------- 1320 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1320 East 8,"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 Total Wall Area in Zone 5 = 4656 402.------WALLS--ZONE 6 ------------------------------------------------ Elevation Type U Insul R Gross(Sgft) --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 4 ----------- 1320 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1320 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1.008 Total Wall Area in Zone 6 = 4656 402.------WALLS--ZONE 7 ------------------------------------------------ Elevation Type U Insul R Gross(Sgft) --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 4 ----------- 1320 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1320 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 Total Wall Area in Zone 7 = 4656 402.------WALLS--ZONE 8------------------------------------------------ ion Efh Type U Insul R Gross(Sgft) --------------------------------- N 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ------------ 0.151 4 ----------- 1320 S 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1320 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1008 West 8"CMU/3/4"ISO Btwn 24"oc,/5/8"Gyp 0.151 4 1008 Total Wall Area in Zone 8 = 4656' 402.--- --- WALLS --ZONE 9 ------------------------------------------------ Elevation Type U Insul R Gross(Sgft) North 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1320 M I M IA 0 1 FJ O r I m W rt 1 I ¢1 •I I rt 1 1 0 I 1 � I I I-' I H O 1 1 � wl \ 1 (D U] IA I I I I O I O 01 d I 0 I IA 0 I 1 Fi I I I I I xl 1 0 1 I N 1 I {✓ I I H O 1 1 0 :4 i I rt 1 I H O 1 I K I I d (D I I 0 1 1 O F•h I I I I (D I I Q) I I I I W I I I I I I N I I 0 I I I 1 (D 1 Tn I w iP M I w IIA 0 0 i N 0W rr I rt I 1 P1 i � �' I p1 •I I rt I I rt I I 0 I I 0 I � O 1 F' I H H I H O w i ►� � w I� ,d I (D W \ I (D Co O O I z 0 1 Rl I txj Ql I tZ I tj I tj I I O I w 0 1 N O I I O i I I-j I I I I Fj I I I I I 1 O I I 0 I I N 1 1 F-I I I H I I N I I 0 1 I H 0 I I I I O I I jt I I (] I 1 ¢1 (] I I O I I F- O I I Fj I I Fj I I (D I 1 0 (D I I 1 I 0 I I Fh I I O Fh I I I I KF-i I m I I I m I � I I of I i I I (D I I I I I I I F-�• I I I I I I I I N I I I I I 0 I I I (D I W O Mz I OW 0 F1 I rr rt 1 . I I 1 cat I 1 F�• I 1 O 1 I � I NFL I HO I I I 0 WWIPd \ \ I (D (D O O I I :2� :24 I 1 1 N aaI � d tj 0 0 K K I I 00 �N H Rl P � rr n PO 0 (D (D 0 I-h Ft K G I✓ n �. (D AI N 0 0 I Fj00 I I II c,.l W I zwwtz I wht�, (D P O O I I-j o m m >r K 1 (D N I rt I I N• I I 0 I I � I I Oo 00 00 0o I F3 0nl)C) r I (D M W W W W I N �\\\I 0 txj H H H H I Tn in Co M 1 00001 WWbdtd I rr ct rt (t 1 N N N N I H IA IA IA 1 0 = = _ = I rr0000 1 w Cl (] 0 0 I F3 Lil(nLnUt I 0 $ \\\\ I rtSv oo�ouao I 0 (D m A� o00o I N N H N F-' N I—' 0 (D I K I m (D I II II IA IA IA IA I �d Lrl OD <CY)00 W W UIUIOONN N6lOODOO :V4tr1wz I wIr' m m G 0 1 (p N rt rt rt rr 1 •1 I ��11 I rt I I N• 1 l0 I � I I 00 00 00 O I H = I C� C1 C1 C1 ; (D m W W W W I N \\\\I 0 H H H H I En M W M I 00001 W W W W I 1 N N N N I H IA IA IA IA 1 0 0 0 0 1 (] Cl (1 (1 I Ul Ul Ul Ul I pi co 0o 0o 00 1 (D O O o o I Ul Ul In Ul I F' Fs F- P I cI N O (D 1 I m I II IA IA �P IP I � Co Ou 00 0o I y = 1 nn�,7 1 N I (D W 1 I W W W W I N \ \ \ \ I 0 H H H H I M (a M C I 00001 W bd bd bd 1 rtctrttt I N N N N I H Its IA IA IA I r 0 0 0 0 1 Ul Ul Ul Ul 1 Pi co 00 co OD I H 0 Q 5G) t�GG) K 'V 1 (D A) O000 I P. F1 F-+ F-' I--' I Ul Ul Ln Ul I F-' I C, N O (D 1 1 m N I I II IA IA IA IA 1 '� mPi00 iNo rrrrr'rt i •I 1 rr 1 I F-� • i 101 1 � I ;_5 000DOO I H 1 CIf)n(] N W W W W I N \\\\1 0 I z = I lzj H H H H I U) co M C I 00001 W W W W 1 I N N N N I ft 0 0 0 0 I Ul Ul Ul Ul I AI 0o 0o w 0o I (D A� 0000 I N 0 (D I I (f] FJ 1 O I N i II IA IP IA 4, I �d mPJ0 mml; rt rt rt 00 0o 0o W W W H H H 000 w w w N N N H IA CIA IA rot 0 0 0 Ai a 0 C1 trLTIN Ai OD co 0u F-' Q G a) (D p) Ooo N-N N N u, U, U, N O 0 0 II IA IA IA a I 1 0 1 1 0 1 1 Q 1 Fi I I F; I i Fi I I Fi 1 0 1 l o l l 0 1 1 0 1 in I I m I I m I I m 1 m I I I m I I in I 1 m I � I r. l 1 i I .-� I 1 1 .•� 1 1 Cn I n I+i H yAF'F'F',� IAF PF'P i FQ I IA I-' F-' F- FJ 14 I IA F-' N F-' I-h 1 Ol O O W W I Ffi 1 O> O O W W I F•h I Ol O O W W I F-h I M O O W rr I UIOONN I rt I UIOONN I rr I UIOONN I rr I UIO(DN `� 1 0)000000 1 I (A000000 1 I m00w 00 1 I m0000o 403.------DOORS--ZONE 5 ------------------------------------------------ Elevation Type U Area(Sgft) South 1-3/4 Wood Door -Hollow core flush 0.46 140 Total Door Area in Zone 5 = 140 403.-7=---DOORS--ZONE 6 ------------------------------------------------ Elevation Type U Area(Sgft) --------------------------------------------------- ----- ---------- South 1-3/4 Wood Door -Hollow core flush 0.46 140 Total Door Area in Zone 6 = 140 403.------DOORS--ZONE 7 ------------------------------------------------ Elevation Type U Area(Sgft) --------------------------------------------------- --------------- Sokth 1-3/4 Wood Door -Hollow core flush 0.46 140 Total Door Area in Zone 7 = 140 4------DOORS--ZONE 8------------------------------------------------ E1tion Type U Area(Sgft) --------------------------------------------------- ----- ---------- South 1-3/4 Wood Door -Hollow core flush 0.46 140 Total Door Area in Zone 8 = 140 403.------DOORS--ZONE 9 ------------------------------------------------ Elevation Type U Area (Sgft) --------------------------------------------------- ----- ---------- South 1-3/4 Wood Door -Hollow core flush 0.46 140 Total Door Area in Zone 9 = 140 403.------DOORS--ZONE 10 ------------------------------------------------ Elevation Type U Area(Sgft) --------------------------------------------------- ----- ---------- South 1-3/4 Wood Door -Hollow core flush 0.46 140 Total Door Area in Zone 10 = 140 403.------DOORS--ZONE 11 ------------------------------------------------ Elevation Type U Area(Sgft) --------------------------------------------------- ----- ---------- South 1-3/4 Wood Door -Hollow core flush 0.46 140 Total Door Area in Zone 11 = 140 403.------DOORS--ZONE 12 ------------------------------------------------ Elevation Type U Area ( Sqf t ) --------------------------------------------------- ----- ---------- South 1-3/4 Wood Door -Hollow core flush 0.46 140 Total Door Area in Zone 12 = 140 403.------DOORS--ZONE 13 ------------------------------------------------ Elevation Type U Area(Sgft) --------------------------------------------------- ----- ---------- South 1-3/4 Wood Door -Hollow core flush 0.46 140 Total Door Area in Zone 13 = 140 Total Door Area = 1890 404.------ROOFS--ZONE 1 ------------------------------------------------ T Color U Insul R Area(Sgft) ------------------------------- ------ ---------------------- C Tile/1/2"WD Deck/WD Truss/ Light 0.040 19 2000 Total Roof Area in Zone 1 = 2000 404.------ROOFS--ZONE 2 ------------------------------------------------- Type Color U Insul R Area (Sgft) ------------------------------------ ------ --------------------- Conc Tile/1/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 2 = 9240 404.------ROOFS--ZONE 3 --------------------------------------- Type Color U Insul R Area ( Sqf t ) i Total Floor Area in Zone 1 = 2000 405.------FLOORS-ZONE 2 ------------------------------------------------ Type Insul R Area(Sgft) Floor over Conditioned Space/Insulated 10 9240 Total Floor Area in Zone 2 = 9240 405.------FLOORS-ZONE 3 ------------------------------------------------ Type Insul R ------- Area(Sgft) ---------- -----=------------------------------------------ Floor over Conditioned Space/Insulated 10 9240 Total Floor Area in Zone 3 = 9240 405.------FLOORS-ZONE 4 ------------------------------------------------ Type Insul R Area(Sgft) ---------------------------------------------- ------- ---------- F r over Conditioned Space/Insulated 10 9240 Total Floor Area in Zone 4 = 9240 4' .------FLOORS-ZONE 5------------------------------------------------ Type Insul R Area ( Sqf t ) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 5 = 9240 405.------FLOORS-ZONE 6 ------------------------------------------------ Type Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned Space/Insulated ' ------- 10 ---------- 9240 Total Floor Area in Zone 6 = 9240 405.------FLOORS-ZONE 7 ------------------------------------------------ Type Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 7 = 9240 405.------FLOORS-ZONE 8 ------------------------------------------------ Type . Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 8 = 9240 405.------FLOORS-ZONE 9------------------------------------------------I Type Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 9 = 9240 405.------FLOORS-ZONE 10-------------------------- -------- -------------- Type Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 10 = 9240 405.------FLOORS-ZONE 11------------------------------------------------ T Insul R Area ( Sqf t ) --------------------------------------------- r over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 11 = 9240 4 5.------FLOORS-ZONE 12------ ----- ------ ----- - ------ -------------- ---- Type Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 12 = 9240 405.------FLOORS-ZONE 13 ------------------------------------------------ Type Insul R Area(Sgft) ----------------------------------------------------------------- Floor over Conditioned Space/Insulated 10 9240 Total Floor Area in Zone 13 = 9240 Total Floor Area = 112880 406.------INFILTRATION -------------------------------------------------- IInfiltration Criteria in 406.1.ABCD have been met. CHECK MECHANICAL SYSTEMS CHECK HVAC load sizing has been performed. (407.1.ABCD) 1 407 ------- COOLING SYSTEMS----------------------------------------------- Type No Efficiency IPLV Tons ater Cooled / Water Source 1 11.6 9 4.75 2. Water Cooled / Water Source 1 11.6 9 12.67 3. Water Cooled / Water Source 1 11.6 9 12.67 4. Water Cooled / Water Source 1 11.6 9 12.67 S. Water Cooled / Water Source 1 11.6 9 12.67 6. Water Cooled / Water Source 1 11.6 9 12.67 7. Water Cooled / Water Source 1 11.6 9 12.67 8. Water Cooled / Water Source 1 11.6 9 12.67 9. Water Cooled / Water Source 1 11.6 9 12.67 10. Water Cooled / Water Source 1 11.6 9 12.67 11. Water Cooled / Water Source 1 11.6 9 12.67 12. Water Cooled / Water Source 1 11.6 9 12.67 13. Water Cooled / Water Source 1 11.6 9 12-67 408.------HEATING SYSTEMS ----------------------------------------------- Type -------------------------------- No --- Efficiency ------------------------ BTU/hr 1. Water Source 1 4.2 9300 2. Water Source 1 4 240900 3. Water Source 1 4 240900 4. Water Source 1 4 240900 5. Water Source 1 4 240900 6. Water Source 1 4 240900 7. Water Source 1 4 240900 8. Water Source 1 4 240900 9. Water Source 1 4 240900 10. Water Source 1 4 240900 11. Water Source 1 4 240900 12. Water Source 1 4 240900 13. Water Source 1 4 240900 409.------VENTILATION --------------------------------------------------- I ---------------------------------------- ------------------------ suoTT-eD aq-eggndui ssoaAcpupgS AouatoTjja adz,j, ----------------------------------T HNOZ-SInaMy S JNIJVHH 'dHIVM------ ZT:� --------------------------- ------------------------ .ssau3{ozuy as-4auzeTQ uT/anTPA-g adity ---------------------------------------ZT aNOZ-JNIdId GNX ScIPMcl-----'TTV --------------------------- ------------------------ ssauxoiuy as-4am-etQ uT/anTPA-g adAy ---------------------------------------ZT SNOZ-JNIdId GKV Shcnind ----- --------- ' ssauNozuy as-4aui-ezQ u-t/anTUA-U ad�i ---------------------------------------TT HNOZ-ONIdId GRV SclMd------ TT:P ssau%{ozuy aagauretQ uz/an-[UA-g adAy ---------------------------------------OT HNOZ-ONIdId QNV Sclwfld----- •TTb ssauxozuy aa�aui-eza u-r/anTPA-g adRy ---------------------------------------6 HNOZ-JNIdIa GKV SdWna----- 'TT:i --------------------------- ------------------------ ssauxoTuy aagGw-eTQ u-r/anTPn-U adAy ---------------------------------------8 HNOZ-JNIdId GNV ScTK[ld------ TT�, --------------------------- ------------------------ ssauXDTuy aa-;aurezQ uT/anTPn-g ad,�y ---------------------------------------L HNOZ-:JNIdId QNV SdWfld------ TT:f, --------------------------- ------------------------ ssauxozuy aagaWPTCj uT/anT'en--d eddy ------ --------------------------------- 9 HNOZ-E)NIaId aNV Sawna-----•TT� --------------------------- ------------------------ ssau3(ozuy aagaux-ezQ ut/anT-eA-U ad'�y ---------------------------------------s HNOZ-E)NIaIa aNV Sdwna-----•TT� --------------------------- ------------------------ ssau--�{ozuy as-4aui-ezQ uz/anT,en--d ad,�y ---------------------------------------V HNOZ-E)NIaIa GKV Sdvsnd------TTi� --------------------------- ------------------------ ssauNozuy as-4aui-ezQ uT/anTPn-U adt�y ---------------------------------------C HNOZ-ONIdId aNV sdWnd-----•TTfi, --------------------------- ------------------------ ssauxozuy aaqaum-I u. /anTPn-U ad�y ---------------------------------------Z HNOZ-f)NIaId aNV SdHnd-----•TTV --------------------------- ------------------------ ssauxozuy aagauU-etQ ui/anTPA-H aCMy ---------------------------------------T HNOZ-JNIdId QNFZ' SdWficT-----TT ,�� sl4H,LSAs E)NIHWnrid -qaw uaaq anPu QOaV•T•TT-v uz squauiaaznbaa GATgdtaosaad ozspa ----------------------------------------- HNOZ-ONIdId QNv ShcnInd----- 'TTi� _ (QO�' T ' OT:V ) • pawaojaad aq TTTM buTOUPTL-q pu-e 5uz-4say ----- ------------------------------------------------------- xaHHD :iT oopd5 pauozgTpuoa :�T aoud5 pauoTgTpuoO TvT aopds pauozgzpuoO VT aopdS pauoTgTpuoO :�T aopdS pauozgTpuoO VT aopdS pauoTgTpuoO TVT aopdS pauozgzpuoO VT aopdS pauoTgTpuoa dwnd gPGH 00ano5 aaquM -ET dwnd gPGH aoanoS aGgPM 'ZT dwnd TeaH aoano5 as-4-eM 'TT dwnd quaH aoanoS aGgPM •OT dwnd gPaH aoano5 aagpM '6 dwnd gPGH aoanog_ aaq-eM • 8 dwnd qP@H aoanoS aaq-eM •L dwnd gPGH aaanoS aaq-eM •9 . 412.-----WATER HEATING SYSTEMS -ZONE 2 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons -----=---------------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 3 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ----------------------------------------------------------------- 412------ WATER HEATING SYSTEMS -ZONE 4 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons -=-------------------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 5 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ---------------------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 6---------------------------------- e Efficiency StandbyLoss InputRate Gallons T7 4 =----WATER HEATING SYSTEMS -ZONE 7---------------------------------- Type Efficiency StandbyLoss,InputRate Gallons ---------------------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 8 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ---------------------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 9 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ---------------------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 10 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ---------------------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 11 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ------------------------ ---------- --- -------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 12 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ---------------------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 13 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ELECTRICAL SYSTEMS CHECK 413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- ----- Metering criteria in 413.1.ABCD have been met. 414.-----MOTORS --------------------------------------------------- ----- Motor efficiencies in 414.1.ABCD have been met. 415.-----LIGHTING SYSTEMS -ZONE 1 --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ------ ---------- First Thre 1 On/Off 10 2000 2000 Total Watts for Zone 1 = 2000 Total Area for Zone 1 = 2000 .-----LIGHTING SYSTEMS -ZONE 2--------------------------------------- S .ce Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ------ ---------- Each Addit 1 On/Off 20 1500 9240 Total Watts for Zone 2 = 1500 Total Area for Zone 2 = 9240 415.-----LIGHTING SYSTEMS -ZONE 3--------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ------ ---------- Each Addit 1 On/Off 20 1500 9240 Total Watts for Zone 13 = 1500 Total Area for Zone 13 = 9240 Total Watts = 20000 Total Area = 112880 CHECK Lighting criteria in 415.1.ABCD have been met. 16. Operation/maintenance manual will be provided to owner.(102.1) ---------------------------------------------------------------------------- ►J `------------------------------------ ------ ---------------------- Conc Tile/1/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 3 = 9240 404.------ROOFS--ZONE 4--------------------- --------------------------- Type Color U Insul R Area(Sgft) ------------------------------------ ------ ---------------------- Conc Tile/l/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 4 = 9240 404.------ROOFS--ZONE 5 ------------------------------------------------ Type I Color U Insul R Area ( Sqf t ) ------------------------------------ ------ ---------------------- Conc Tile/1/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 5 = 9240 4 .------ROOFS--ZONE 6 ------------------------------------------------ T Color U Insul R Area (Sgft) Co'c Tile/1/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 6 = 9240 404.------ROOFS--ZONE 7 ------------------------------------------------ Type Color U Insul R Area(Sgft) ------------------------------------ ------ ---------------------- Conc Tile/1/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 7 = 9240 404.------ROOFS--ZONE 8 ------------------------------------------------ Type Color U Insul R Area(Sgft) ------------------------------------ ------ ---------------------- Conc Tile/l/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 8 = 9240 404.------ROOFS--ZONE 9 ------------------------------------------------ Type Color U Insul R Area ( Sqf t ) ------------------------------------ ------ ---------------------- Conc Tile/l/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 9 = 9240 404------- ROOFS --ZONE 10 ------------------------------------------------ Type Color U Insul R Area(Sgft) ------------------------------------ ------ ---------------------- Conc Tile/1/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 10 = 9240 404.------ROOFS--ZONE 11 ------------------------------------------------ Type Color U Insul R Area ( Sqf t ) ------------------------------------ ------ ---------------------- Conc Tile/1/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 11 = 9240 404.------ROOFS--ZONE 12 ------------------------------------------------ Type Color U Insul R Area(Sgft) ------------------------------------ ------ ---------------------- Conc_Tile/l/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 12 = 9240 4 ------ROOFS--ZONE 13------------------------------------------------I T Color U Insul R Area(Sgft) Conc Tile/l/2"WD Deck/WD Truss/ Light 0.040 19 9240 Total Roof Area in Zone 13 = 9240 Total Roof Area = 112880 405.------FLOORS-ZONE 1-------------------------------------- ---------- Type Insul R Area(Sgft) Floor over Unconditioned Space/Insulated 10 2000 Total Floor Area in'Zone 1 = 2000 405.------FLOORS-ZONE 2 ------------------------------------------------ Type Insul R ------- Area ( Sqf t ) ---------- ------------------------------------------------ Floor over Conditioned Space/Insulated 10 9240 Total Floor Area in Zone 2 = 9240 405.------FLOORS-ZONE 3 ------------------------------------------------ Type Insul R ------- Area ( Sqf t ) ---------- ------------------------------------------------ Floor over Conditioned Space/Insulated 10 9240 Total Floor Area in Zone 3 = 9240 405.------FLOORS-ZONE 4 ------------------------------------------------ Type Insul R ------- Area ( Sqf t ) ---------- ------------------------------------------------ Floor over Conditioned Space/Insulated 10 9240 Total Floor Area in Zone 4 = 9240 405.------FLOORS-ZONE 5 ------------------------------------------------ Type ------------------------------------------------ Insul R ------- Area(Sgft) ---------- Floor over Conditioned Space/Insulated 10 9240 Total Floor Area in Zone 5 = 9240 405.------FLOORS-ZONE 6 ------------------------------------------------- Type Insul R Area ( Sqf t ) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 6 = 9240 405------- FLOORS -ZONE 7 ------------------------------------------------ Type Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned.Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 7 = 9240 405.------FLOORS-ZONE 8------------------------------------------------ Type Insul R Area ( Sqf t ) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 8 = 9240 405.------FLOORS-ZONE 9 ------------------------------------------------ Type Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 9 = 9240 405.------FLOORS-ZONE 10---------------------------------- -------------- Type Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 10 = 9240 405.------FLOORS-ZONE 11 ------------------------------------------------ Type Insul R Area(Sgft) ------------------------------------------------ Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor.Area in Zone 11 = 9240 405.------FLOORS-ZONE 12 ------------------------------------------------- Type ------- Insul R Area(Sgft) ----------------------------------------- Floor over Conditioned Space/Insulated ------- 10 ---------- 9240 Total Floor Area in Zone 12 = 9240 405.------FLOORS-ZONE 13 ------------------------------------------------ Type Insul R Area(Sgft) -------------------------------------- - - - - -- ---- - - - - ------ - - - - - - Floor over Conditioned Space/Insulated 10 9240 Total Floor Area in Zone 13 = 9240 Total Floor Area = 112880 406.---•---INFILTRATION -------------------------------------------------- ICHECK Infiltration Criteria in 406.1.ABCD have been met. MECHANICAL SYSTEMS CHECK HVAC load sizing has been performed. (407.1.ABCD) 1 407.------COOLING SYSTEMS ------------------------------------------------ Type No Efficiency IPLV ------------- ------------------- Tons 1. ---------------------------- Water Cooled / Water Source 1 11.6 9 4.75 2. Water Cooled / Water Source 1 11.6 9 12.67 3. Water Cooled / Water Source 1 11.6 9 12.67 4. Water Cooled / Water Source 1 11.6 9 12.67 S. Water Cooled / Water Source 1 1 11.6 9 12.67 6. Water Cooled / Water Source 1 11.6 9 12.67 7. Water Cooled / Water Source 1 11.6 9 12.67 8. Water Cooled / Water Source 1 11.6 9 12.67 9. Water Cooled / Water Source 1 11.6 9 12.67 10. Water Cooled / Water Source 1 11.6 9 12.67 11. Water Cooled / Water Source 1 11.6 9 12.67 12. Water Cooled / Water Source j 1 11.6 9 12.67 13. Water Cooled / Water Source 1 11.6 9 12-67 408 ------- i HEATING SYSTEMS -------- --------------------------------------- Type ------------------- ---------- No Efficiency --- --------------------------- BTU/hr 1. Water Source 1 4.2 9300 2. Water Source 1 4 240900 3. Water Source 1 4 240900 4. Water Source 1 4 240900 5. Water Source 1 4 240900 6. Water Source 1 4 240900 7. Water Source 1 4 240900 8. Water Source 1 4 240900 9. Water Source 1 4 240900 10. Water Source 1 4 240900 11. Water Source 1 4 240900 12. Water Source 1 4 240900 13. Water Source 1 4 240900 409.------VENTILATION --------------------------------------------------- CHECK Criteria in 409.1.ABCD have been met. IVentilation 410.-----AIR DISTRIBUTION SYSTEM --------------------------- ------------- CHECK --------------------------- Duct sizing and design have --------=--------------------- been performed. (410.1.ABCD) ---- AHU Type Duct Location R-value 1. ----------------------------------- Water Source Heat Pump ---------------------- Unconditioned Space ------- 14 2. Water Source Heat Pump Conditioned Space 14 3. Water Source Heat Pump Conditioned Space 14 4. Water Source Heat Pump Conditioned Space 14 5. Water Source Heat Pump Conditioned Space 14 "6. Water Source Heat Pump 7. Water Source Heat Pump 8. Water Source Heat Pump 9. Water Source Heat Pump 10. Water Source Heat Pump 11. Water Source Heat Pump 12. Water Source Heat Pump 13. Water Source Heat Pump Conditioned Space 14 Conditioned Space 14 Conditioned Space 14 Conditioned Space 14 Conditioned Space 14 Conditioned Space 14 Conditioned Space 14 Conditioned Space 14 CHECK --------------------------------------------------------- ---- Testing and balancing will be performed. (410.1.ABCD) 411.-----PUMPS AND PIPING -ZONE ----------------------------------------- Basic prescriptive requirements in 411.1.ABCD have been met. PLUMBING SYSTEMS 411.-----PUMPS AND PIPING -ZONE 1 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411.-----PUMPS AND PIPING -ZONE 2 --------------------------------------- Type R-value/in Diameter Thickness 411.-----PUMPS AND PIPING -ZONE 3 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411.-----PUMPS AND PIPING -ZONE 4 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411.-----PUMPS AND PIPING -ZONE 5 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411.-----PUMPS AND PIPING -ZONE 6 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411.-----PUMPS AND PIPING -ZONE 7 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411.-----PUMPS AND PIPING -ZONE 8-----------------'---------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411------ PUMPS AND PIPING -ZONE 9 --------------------------------------- Type R-value/in Diameter Thickness ------------------------ ---------- -------- ---------I 411.-----PUMPS AND PIPING -ZONE 10 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411------ PUMPS AND PIPING -ZONE 11 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411.-----PUMPS AND PIPING -ZONE 12 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 411.-----PUMPS AND PIPING -ZONE 13--------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 1 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ---------- ------ ----------------- ----------------- ------------ (-4gbS) -ee-IV s-4-TeM ON Z adAy TOaquoa ON T adAy Toaquoa ON adeiy aopdS ------------------------------------------£ RNOZ-SWayS.T-S JDIIyHOIrI------ SU OVZ6 = Z auoZ .zoo L-a.zV T-e-oy OOST = Z auoZ zog sggpm Tpgoy O:VZ6 OOST OZ JJO/u0 T gTpPV ua'eS ---------- ------ ----------------- ----------------- ------------- ( -4;bS) -ea-iv sqq-eM ON Z adAy TOJgUoa ON T adAy TOaquoa ON adAy aopdS ---- --------------------------------- - - - - -Z alloz-SWa.LS7,.S E)NI,I,HOI'I----- 'STV OOOZ = T 'auoZ JOJ P9.1V Ta:.oy OOOZ = T auoZ .z09 sqq"eM Tegoy OOOZ OOOZ OT 990/uO T a.zr4y gSzT3 ---------- ------ ----------------- ----------------- ------------- (:4-;bS) -e@-TV s-4q-eM ON Z adAy To.z:4uoa ON T adAy To.zWoa ON adAy aoledS ------------------------------------------T HNOZ-SHaM5 S ONI,I,H`)IrI----- 'STI, - gaui uaaq an'eu CIDSV- T' -VT-V UT saT3u9-r0t9J9 zo-4oN --- --------------------- :----------------------------------- SHOWN ------ IiT:P, ----------------I------------ uaaq GAPq GD9V-T' £TT' UT PTaGgTzo buTaGg9W -------------NOIyIIgIujsicl 2iaMOd 'IKaI-diza'IH ----- ' £TTV XDaHa SWayS2�S 'Ival2uyaa'ia -------------------- '-------------------- ------------------------ suoTTL-O a-4-eHgndul ssorjAgpua-4S AouaToTija adAy -------------------------------------£T aNOZ-SHaIS2�S DNIJ.VaH 2IayKM------ ZTV ---------------------------------------- ------------------------ suoTT-eO a-4L-ggndul ssogAgpupgS AouaToTjga adAy ---------------------=---------------ZT aNOZ-SH=MS S JNIlVaH 'daJ.VM----- 'ZTV suoTT-eO a-4-eH-4ndu2 ssoZAgpu-eq5 --- AouatoT��� adAy ----------------------I-----------TT HNOZ-SWaLS2�S `)NIlVaH IdalVM-----' ZT:i ---------------------------------------- ------------------------ suoTTL-O a-4-eg-4ndul ssoZAgpupgS AouaToTjga adAy ------------------------- '------------OT aNOZ-SWELS2�S JNIlVaH- dajVM-----'ZT% ---------------------------------------- ------------------------ suoTT•sO a-q-eH-4ndul ssoZAgpupgS AouatoTj;a adAy ------------------ ------------------- 6 HNOZ-SHaISAS JNIyKEIH 'dHJVM------ ZT% ---------------------------------------- ------------------------ suoTTPO a-4-eH-4ndul ssogAgpupqS AouatoTjja adAy -------------------------------------8 SNOZ-SWEEySAS JNIJ.VaH EaJ.VM----- 'ZT:V ---------------------------------------- ------------------------ suoTT-eO a-4-eH-qndul ssoZAgpuPg5 AouaToTJJH adAy -------------------------------------L HNOZ-SWHJSAS )NIIVE(H 2aJVM----- 'ZTIi ---------------------------------------- ------------------------ suoTT-eD a-4pg-qndu2 ssoZAgpuPgS AouaToTJgH adAI -------------------------------------9 aNOZ-SWaISAS SNI,LVE[H 2aIVM----- 'ZTV ---------------------------------------- ------------------------ suoTTL-O agaH-4ndu2 ssogAgpupgS AouaToTjja adAy -------------------------------------5 HNOZ-SWaySAS JNIIVHH 'daLVM-----'ZTi� ------------------------------ -- ------ ------------------------ suoTT-eO a:1-eHgndul ssoZAgpupg5 AouaToTgja adAy -------------------------------------b HNOZ-SWaySAS ONIJ.Va llaJVM-----'ZT% ---------------------------------------- ------------------------ suoTT-eO a-4-eH-4ndul ssoZAgpupgS AouaToTjga adAy -------------------------------------£ HNOZ-SWHIS2�S JNIJVaH 'daJ.VM------ZTip ---------------------------------------- ------------------------ suoTT-eO a-4-eggndul ssogAgpuagS AouaToTjga adAy ------------------------------ -----Z aNOZ-SWaySAS JNIJVaH Ha.IVM------ ZTiv. A N I w FP Ut n 1 I (D I y I r rt 1 (D H {-{ �+a I H H I 0 H o� 0m w O- n 1 F01-3 ' LIJ 1-3 Uri I I I N I N 0 (D O � I N LIJ N I N W N I O N 1 O I 1 y I IiA I O rt I (� I (t p) I O I I Q1 I--' I t I � ¢) i 0 1 (KD (rt't I ~ y I 1 I I I tt1 htl 1 1 1 O O I (D I I K K 1 I I I N I 1 N N I 1 0 0 I I I (D (D I 0 I I I 1 N N I I 1 11 II Ul I rt I I o 1 rt I 1 o I U) I I I I 1 K I I I (D I I N Ul N I t-h I 1 lip O FP 1 (t I I 000 1 1 L=J FJ Ul r O I wIA I ro F� . w I wIA f ro f--I m w 1 WIN f ro F1 trJ 1 wFP f ro H w p I wIA I ro N (] I W Ul n- n F3, I A) U7 1 n 0 O., I A) Ul n ILn - - I (D 1 1 (D I I (D I I (D I I (D' I N- I I p, I-+- I I 1 I a N• I I '"(} a � 1-(j rt l cD r rr 1 r rt I I (D rl W rt I I I (D r+ rt I I 1 r I GH2 1 H 1 H i O H H i O H H H 10 H p f-' i O H F' i O H ��. 0 1 n 0 0 1 n GZ2 O I n� O 1 n a) 0 1 n O 0rn 1 rtk �� O 0cn 1 rr F'i �� 0 0V) 1 rt k �� 0 0 1 rrrK o 1 0 rr�. t-h t h I 1-1 w I O y t-h t-h I K w 1 0 y t-h 1-h I K w 10 y I-'h t-h I ti In I O y tt1 ttl 1 K (n 1 0 y H M 1 I F- M 1 F' Lz1 I F-' L1j. 1 F-trJ 1 (D O I (DO 1 (D O I (D O 1 (D O 1 N I N I N L71 I N tij I F-' tZij N I Z O 01 y 0 1 1 O y I O o 0 1 I1-3 0 1 0 10 O y 1 0 1-3 0 1 y 0 1 1-3 0 1 y 0 P) 1 pe 1 P) 1 O 1 rt r rot W 1 0 1 rOt p 1 O 1 rt P) 1 0 ~ a I ~ i I ~ i I ~ PJ ~ FF-J :E; I rt 1 K 1 0 IP-' �' � (fit 1 0 1 FP-' � rat I 111 F-' �; rat I I ti I F-' i ft 1 K 11 rat' I l-� I ti (t I F-+ I F1 rat I F0-' I tFi cat I O I F A) I 0 ~ (D rt I I (D rr I I (D (t I I (D rt I 1 (D (fit I Q) In I y I p) W I y I ¢) U] I y 1 w Tn I y I P) m 1 y I-h t-h i i I-h I-h i i F-h ti1 i 1� i t-h I-h i i t-h t-h 0 0 I (D 1 O 0 I (D 1 0 0 I (D 1 0 0 1 (D 1 0 0 I (D K K 1 1 K K 1 I K K 1 I K K I I 1-1 K , I N I I N I I N I I N I I N N N I N N I N N I N N I N N 0 0 I 10 0 I 1 0 0 I 10 0 , , 0 0 , (D(D 0 I (D(D I 0 1 I I I I 0 1 (D(D I 0 I (D(D((DD I OZ FI H I I N N I 1 I I I I I I I F-' F-' O O �D t'O I :E' 1 00 OD I $y I J J I H I jU I 1- I W I I-1 I W I F I I ¢) I F-+ I W II II Ul I (t I II II Ul• 1 rr 1 II II Ln I rr 1 11 11 Ul I rt 1 II II Ul I (t O I (t 1 0 1 rt 1 O 1 (t 1 O 1 rt 1 O 1 rt I I I I I I 1 K I 1 K I I tl I I I (D 1 1 (D I I (D I I (D I I (D 1 ¢1 I I Q) I I P I I ¢1 I jn 1 I jJ] I 1 I;n I 1 f;J] I I jJ] �D P %D I I tD {J 1,0 I I lD N lD I I W F- t D I 1 W H�D I N Ul N I t-h I N Ul N I t-h I N Ul N I tit I N Ul N I t-h I N Ul N I ttl IP O FP I (-t I FP O FP I (t -1 IA o IA I (t I IP O IA I rt I IA 0 FP I (t O O O 1 1 0 0 0 1 1 0 0 0 1 1 0 0 0 1 1 0 0 0 1 rrJ I (/] FP lzj 1 m IA trJ I m FP Iron Iron IroFJ 1 �cn w L" Sul I (D I I (D I I I (D I I I a l y y y I a rt 1 (D r rt 1 (D r rr I m r H H H I I-' I 0 H F� i 0 F3 P 1 O H o o o O: o O o o I :j to \ 1 0 Tn \ 1 0 Tn 0 1 rr k 0 1 rt F-4 0 1 rt I-.4 f-h 1 K U) M I K. (n t-h I ti to �• O I F I O' LyTJ i yAw yin I y(D 1 N I -(D O' I (D O I(D O 1 z I I N I I d1 o I 1 0 `1' I z o r O o 1 0 1A 1 y 1 y 1.30 I 30, I HO 0 rt I n 1 0 rt I 1 0 rr I (� rt j) 1 0 1 rt, A) 1 .0 1 rt A) I O 1 0 1 p 0 1 P) N I �j: F' I rt I F' I rt 1 I- 4 I (t G 1 K 1 i ::4 1 K 1 F- --: I K. O h�01i rPir t�Dli rt I I tt rr I (D rt I I (D rr 1 I I (D (t I ¢) U) 1 y 1 ¢) to I y I ¢) rn 1 y t-h t-h I I I I t-h t-h I I I I t-h rh I 0 0 1 (D 1 0 0 1 (D 10 0 I 1 (D. K K 1 I K K I I K ti I I N I I N I I N N N I N N I N N 0 0 1 1 0 0 1 l 0 0 1 00 Iz1rj0 Iz10t Iz (D (D 1 0 1 I (D (D 1 0 1 I (D (D 1 0 0) 61 I I I :E, I Ul Ul I I I :E! I FP IP I I ::E,' II II Ul I (t 1 II II Ul I rt 1 II 11 Ul I rt 0 1 rt 1 O 1 rt I O I rr O I U) 1 0 1 m 1 0 1 Ul I I 1 K I I K 1 I F�j 1 (D I I (D I I (D I [J] I I (J] I 1 IDF-ID I,Q 1 IDN\�D 1 I wp - D N Ul N I til I N Ul N I t fl I N Ul N I t-h FP O Itb I rt I IP O IA 1 rt I FP O Ft� I rr O O O 1 1 0 0 0 1 1 0 0 0 1 t= P) F'- H N 0 O Ot rr �u p 1--i F-' (D rt p)tn� 0 0 K K 0 0 (D W W N 0 0 A •Space Type No Control Type 1 INo Control Type 3 No Watts Area(Sgft) ---------- --------------------------------- --- ------ ---------- Each Addit 1 On/Off 20 1500 9240 Total Watts for Zone 13 = 1500 Total Area for Zone 13 = 9240 Total Watts = 20000 Total Area = 112880 CHECK Lighting criteria in 415.1.ABCD have been met. 16. Operation/maintenance manual will be provided to owner.(102.1) ----------------------------------------------------------------------------