HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFI �Aff'1166DE FC
Florida Department of Business and Professional Regul
)N
Project Name: MW-98
Builder NameP: y r Yit
Street: 2701 BENT PINE DR
Permit Office:
+
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number: 1666
Owner:
Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
County:: St. Lucie (Florida Climate Zone 2 )
I
1. New construction or existing New (From Plans)
9. Wall Types (2370.4 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 2060.60 ft2
b. Frame - Wood, Adjacent
R=11.0 309.78 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft 2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2254.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2254.00 ft2
6. Conditioned floor area above grade (ft2) 2254
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. A
R= ft2
11. Ducts
R ft2
7. Windows(369.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 .. 766
a. U-Factor: Dbl, U=0.58 369.26 ft2
SHGC: SHGC=0.26
b. U-Factor: N/A ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
46.0 SEER:16.00
c. U-Factor: N/A ft l
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
8. Floor Types (2254.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2254.00 ft2,
b. Conservation features
EF: 0.940
b. N/A R= ft21
None
c. N/A R= ft2
I
15. Credits
Pstat
Total Proposed Modified Loads: 74.06
Glass/Floor Area: 0.164 I
PASS
Total Baseline
Loads: 74.36
I hereby certify that the and specifications by
Review the
ST'4?�
plans covered
of plans and
0114E
this calculation are in compliance with the Florida Energy
specifications covered by this
ti, _- : O
Code. /
calculation indicates compliance
with the Florida Energy Code.
rn,,s;.,' ., •.,;:c�' ,,. y„ O
PREPARED BY:
Before construction is completed
-
DATE: 06/25/18
this building will be inspected for
compliance with Section 553.908
I hereby certify tha�,tYs� ' as a d, is in compliance
Florida Statutes.
with the Florida E ergy od
COD WME �V
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
1
6/26/2018 2:02 PM EnergyGauge® USA - FlaRes2017 Sectio Rom. . om Cpntap�, Page 1 0 g f4
FORM R405-2017
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-98
User
1
Single-family
New (From Plans)
Bedrooms: 3
Conditii ned Area: 2254
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
2701- BENT PINE DR
St. Lucie
FORT PIERCE,
FL, 34951
CLIMATE
/
V Design Location
TMY Site
Design Temp
97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI
39 90
70
75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2254 20b62.2
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
2254 20962.2
Yes 4
3
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter
R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 209.2
ft 0
I
2254 ft2
----
0 0 1
ROOF
/
V #
Type
Roof
Materials Area
Gable Roof
Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Flat tile/slate 2521
ft2 0 ft2 Medium
0.45
N 0.9
No 0 26.6
ATTIC
V #
Type
Ventilation I Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 2254 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Batt
2254 ft2 0.1
Wood
6/25/2018 2:02 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017
WALLS
Adjacent
I
Cavity Width
Height
Sheathing Framing
Solar
Below
t
In
Wall Type
Space
p
R_l/nlue Et In
Et In
Area R-NIn ue-Fraction Absnr Grade!
1
N
Exterior
Concrete Block - Ext Insul
Main
4 1
8
11 4
18.9 ft2
0
0
0.3
0
2
NE
Exterior
Concrete Block - Ext Insul
Main
4 4
4
8 0
34.7 ft2
0
0
0.3
0
3
NE
Exterior
Concrete Block - Ext Insul
Main
4 55
5
9 4
517.2 ft2
0
0
0.3
0
4
E
Exterior
Concrete Block - Ext Insul
Main
4 2
11
11 4
33.1 ft2
0
0
0.3
0
5
SE
Exterior
Concrete Block - Ext Insul
Main
4 38
10
9 4
362.4 ft2
0
0
0.3
0
6
SW
Exterior
Concrete Block - Ext Insul
Main
4 53
2
9 4
496.2 ft2
0
0
0.3
0
7
NW
Exterior
Concrete Block - Ext Insul
Main
4 5
4
9 4
49.8 ft2
0
0
0.3
0
8
NW
Exterior
Concrete Block - Ext Insul
Main
4 58
9
9 4
548.3 ft2
0
0
0.3
0
_ 9
-
Garage
- Frame - Wood
Main
11 27
4
11 4
309.8 ft2
0
0.25
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
. Height
Area
Ft
In
Ft In
1
SE
Wood Main
None
.39
3
8
24 ft2
WINDOWS
Orientation shown
is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
ne 2
Metal Double (Clear)
Yes
0.58 0.26
N
20.0 ft2
0 ft 0 in
0 ft 0 in
None
None
2
se 5
Metal Double (Clear)
Yes
0.58 0.26
N
48.0 ft2
0 ft 0 in
0 ft 0 in
None
None
3
se 5
Metal Double (Clear)
Yes
0.58 0.26
N
6.0 ft2
0 ft 0 in
0 ft 0 in
None
None
4
se 5
Metal Double (Clear)
Yes
0.58 0.26
N
8.0 ft2
0 ft 0 in
0 ft 0 in
None
None
5
se 5
Metal Double (Clear)
Yes
0.58 0.26
N
9.0 ft2
0 ft 0 in
0 ft 0 in
None
None
6
sw 6
Metal Double (Clear)
Yes
0.58 0.26
N
20.0 ft2
0 ft 0 in
0 ft,0 in
None
None
7
sw 6
Metal Double (Clear)
Yes
0.58 0.26
N
43.3 W
0 ft 0 in
0 ft 0 in
None
None
8
sw 6
Metal Double (Clear)
Yes
0.58 0.26
N
9.0 ft2
0 ft 0 in
0 ft 0 in
None
None
9
nw 7
Metal Double (Clear)
Yes
0.58 0.26
N
7.0 ft2
0 ft 0 in
0 ft 0 in
None
None
10
nw 8
Metal Double (Clear)
Yes
0.58 0.26
N
43.3 ft2
0 ft 0 in
0 ft 0 in
None
None
11
nw 8
Metal Double (Clear)
Yes
0.58 0.26
N
111.6 ft2
0 ft 0 in
0 ft 0 in
None
None
12
NW 8
Metal Double (Clear)
Yes
0.58 0.26
N
44.0 ft2
0 ft 0 in
0 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area
iExposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
687 ft2 687 ft2
j 64 ft
9.3 ft
1
INFILTRATION
# Scope
Method SLA
r
CFM 50 ElA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000295
1746.8 95.9
180.35
.2216
5
6/25/2018 2:02 PM EnergyGauge® USA - Fla4Res2017 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype I
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 16
46 kBtu/hr
1380 cfm
0.7
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.94 50 gal 62.3 gal
120 deg
None
SOLAR
HOT WATER SYSTEM
i
FSEC
Collector
Storage
Cert
# Company Name
System
Model # Collector
Model
# - Area
Volume
FEF
None None
ftz
DUCTS
— Supply ---
-- Return
---
Air
CFM 25 CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1
Attic
6 766 ftZ
Attic
597 ft2 Default Leakage
Main
(Default) (Default)
1 1
(TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating HJan
Jan r Feb
[X] Feb
Mar
Mar
Apr r ay. rl Jun rlJul
E APr [ May Jun Jul
Aug
Aug
ri
Sep (�
f 1 Sepp [ j
Oct
Oct
Nov
Nov
H
Dec
Dec
Ventin
Jan [[[[ ]]]] Feb
X Mar
[X] A r [[I ]]]
Ma Jun Jul
Aug
[ Se [X]
Oct
Nov
Dec
=Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD)
AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
6/25/2018 2:02 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
r
FORM R405-2017
ENERGY PERFORMANCE
LEVEL (EPL)
DISPLAY
CARD
ESTIMATED ENERGY
PERFORMANCE INDEX* = 100
The lower the EnergyPelformance
Index, the more efficient the home.
2701 BENT PIt
E DR, FORT PIERCE, FL, 34951
1. New construction or existing New (From Plans)
9. Wall Types
Insulation
Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0
2060.60 ft2
b. Frame - Wood, Adjacent
R=11.0
309.78 ft2
3. Number of units, if multiple family 1
c. N/A
R=
ft2
4. Number of Bedrooms 3
d. N/A
R=
ft2
5. Is this a worst case? No
I 10: Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
2254.00 ft2
6. Conditioned floor area (ft2) 2254
b. N/A
R=
ft2
7. Windows** Description Area
_
R
2
a. U-Factor: Dbl, U=0.58 369.26 ft,a.
11. Ducts
Sup: Attic, Ret: Attic, AH: Main
R ft2
6 766
SHGC: SHGC=0.26
b. U-Factor: N/A ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A ft2
a. Central Unit
46.0 SEER:16.00
SHGC:
d. U-Factor: N/A ft21
SHGC:
13. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth: 0.000 ft!I
a. Electric Strip Heat
34.0
COP:1.00
Area Weighted Average SHGC: 0.260
8. Floor Types Insulation Area
14. Hot water systems
a. Slab -On -Grade Edge Insulation R=0.0 2254.00 ft2EF:
a. Electric
Cap: 50 gallons
b. N/A R= ft2
0.94
c. N/A R= ft2
b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy aving features which will be installed (or exceeded)
in this home before final inspection. Ot erwise, a new EPL Display Card will be completed
based on installed Code compliant feat res.
0 1UE S A?8
Builder Signature: I Date:
Address of New Home: ��(� City/FL Zip: y�
COD.WE,��
3 y ys�
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/25/2018 2:02 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
Planning & Development Services Department
* UNT30rI Building & Regulations Division
Product Review Affidavit
Building Permit # Owners Name V l (,t r Applicant: `/ vj'YI �ll� ,
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
+31.9 / -34.8
+/-55
MI WINDOWS
FL 17499.1
MPACT
3/16" TAPCONS W/ 1-1/4" MIN. EMBED @ 10" O/C
Mullions
37.7
+/-54
MI WINDOWS
FL 15353.3/ FL 15353.4
IMPACT
1/4" TAPCONS W/ - "MIN. EMBED
Fixed Glass
+33.5 / -36.3
+- 55
MI WINDOWS
FL 15349.5
IMPACT
3/16" TAPCONS W/ 1-1/4" MIN. EMB TOUAL SPACING & 3" FROM EDGE
Block Glass
Skylights
Sliding Glass Doors
+24.3 / -26.6
+/-55
MI WINDOWS
12080
FL-22401.3
IMPACT
3/16" TAPCONS W/ 1-1 . EMBED @ 12" O/C
Swing Type Doors
+31.9 / -34.8
+/-50
THERMA TRU
3080 W/SIDELITE
FL-7630.2
IMPACT
1/4" TAPCONS W/ 1- /4" MIN. EMBED 14" O/C
French Doors
Garage Doors
+28.4 / -34.7
+39.2 / -43.7
WAYNE DALTON
9100
FL-9174.10 R12
N/A
(2) 3/8" TITEN.S S EA. BRACKET
Hurricane Protection
Roof Ventilation
Roofing Material
-83.4 PS F
-172 PS F
..LE ROCFINO PROCUCTS
BEL AIR CONC. TILE
NOA NO. 17-0822.13
N/A
(2) 10d R IL N G SHANK NAILS
Revised 07/22/2014
I have reviewed the above components or cladding and I have approved their
wind loads and forces specified by current code provisions.
Name: ll%�L�/� tWkAA,1 e6L/A,,Jf-2 Signature:
Design Prof: A, 'V a le — Cert. No. �?D�
this structure. These products provide adequate
Date: 5;-111VI, e
to the