HomeMy WebLinkAboutREVISION 8-9-18i
OFFICE USE ONLY: o t - 01
DATE FILED. PERMIT # 1612-0433
REVISION FEE: RECEIPT # 1 y 1
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462.1553
APPLICATION FOR BUILDING PE A-SION
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
1702 BEHRENS RD, Fort Pierce FL
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Changing from modified bitumen system to 5v metal with 301b felt underlayment
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1327208
BUSINESS NAME: Sunrise City CHDO Inc.
QUALIFIERS NAME: Roderick Waller
ADDRESS: 130 S Indian River Drive
CITY: Fort Pierce STATE: FL
PHONE (DAYTIME): 772-201-2850
OWNER/BUILDER INFORMATION:
NAME: Livingston Clark
ADDRESS: 1702 Behrens Rd
CITY: Fort Pierce
PHONE (DAYTIME:
STATE: FL
ARCHITECT/ENGINEER INFORMATION:
ST. LUCIE CO CERT. #:
ZIP: 34950
FAX: 772-907-0420
17:V:1i
ZIP:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX: RECEIVED
SLCCC: 9123109
Revised 06130117
AUG 09 2018
Permitting Department
St. Lucie County, FL
6/3/2018 Florida Building Code Online
-
��-
,a� a a sx c +✓ .n,..
lit _
BCIS Home ;'Log In User Registration i Hot Topics Submit Surcharge Stats &Facts ; Publications ' FBC St ifiai� CIS Sitg..Map �.,1_Inks„ Search j
Florida
# a afl, Product Approval
"3 USER: Public User
LxriTt�i>x:< S7
Product Approval Menu > Product or Application Search > Application List > Application Detail
' 77
(�s 5Ys ✓� a FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Testing Lab
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL2346-R7
Revision
2017
Approved
Approved
E IZ"i'l
Ei
Warrior Roofing Manufacturing
3050 Warrior Road
Tuscaloosa, AL 35404
(205)553-1734 Ext115
Steven@WarriorRoofing.net
Steven Crew
Steven@WarriorRoofing.net
Steven Crew
3050 Warrior Road
Tuscaloosa, AL 35404
(205)553-1734 Ext1024
Steven@WarriorRooflng.net
Steven Crew
3050 Warrior Road
Tuscaloosa, AL 35404
(205) 553-1734 Ext 1024
Steven@WarriorRoofing.net
Roofing
Underlayments
Test Report
at
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COIL CE
REVIEWED BY
DATE
PLANS AND PER I
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
PRI Construction Materials Technologies, LLC
Keystone Certifications, Inc.
10/05/2021
Jesus Gonzalez, P.E.
23' Validation Checklist - Hardcopy Received
FL2346 R7 COI PRI CMT Cert of Independence.rLdf
Standard Year
ASTM D226 2009
ASTM D4869 2016
Approved Testing Lab
FL2346 R7 Equiv FBC 2017 Standards Eguiva ency_pdf
hftps://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgtOc8bnSknRps9x%2fSloLpOST46ODBB%2baF4%3d 1/2
6/3/2018
Product Approval Method
Florida Building Code Online -,
Method 1 Option B
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Prnrluetc
01/17/2018
01/17/2018
01/17/2018
04/10/2018
.. a; I: I a
FL #' I'
f46del,`Number or Name
Description
2346.1
#15 and #30 roofing felt
ASTM D 226 Tested
Limits of Use
Installation Instructions
Approved for.,use in HVHZ: Yes
Approved for use HVHZ: Yes
FL2346 R7 II Installation Instructions.pdf
Verified By:
outside
ImpactrReststant N/A',
PRI Construction Materials Technologies, LLC
Test Reports
' Destgn:Pressur.'e::N}A r .I
FL2346 R7 TR 15A Test Repor ,pdf
Other: Primary roof covering should be installed immediately
FL2346 R7 TR 30A Test Report.pdf
after felt. Roofing felt is not intended to be an unprotected
weathering surface.
2346.2
15w and 30w roofing felt
ASTM D 4869 Tested
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2346 R7 II InstallationInstructions.pdf
Approved for use outside HVHZ: Yes
Verified By: PRI Construction Materials Technologies, LLC
Impact Resistant: N/A
Test Reports
Design Pressure: N/A
FL2346 R7 TR 15w Test Report.pdf
Other: Primary roof covering should be installed immediately
FL2346 R7 TR 30w Test Repor ..pdf
after felt. Roofing felt is not intended to be an unprotected
weathering surface.
Hack Next
ri I t• " • Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. C=i yljght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall fo this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section
i; i <; "•, T C,455.275I1),'Fiorida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
I%.. � one., The emails•provided maybe used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
_.•J i .:i address, please provide the Department with an email address which can be made available to the public. To determine if you area licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
in E- 20
'dCard'
securitym ETRIC:S
https://www.floridabuilding.orglpr/pr app_dtl.aspx?param=wGEVXQwtDgtOcBbnSknRps9x%2fSIoLpOST460DBB%2baF4%3d 2/2
Y y
1L
WARRIOR® ROOFING MANUFACTURING
P.O. BOX 40*5 • TUSCALOOSA, AL 35404 • PHONE (205) 5534734 • FAX (205) 5534755
I
193 LEROY ANDERSON ROAD • MONROE, GA 30M • PHONE (770) 207-0695 • FAX (770) 207-0775
,t
323 DEVELOPMENT AVENUE • CHAMBERSBURG, PA 17201 • PH 4) 3 1gx% C& a
u N
Roofing Felt Installation Recommendations
Be aware that roofing felt should not be walked upon prior to fastening into position.
Proper safety equipment is recommended for all installations. Also, the roof decking
should be clear of debris and moisture prior to installation of the roofing felt.
Roofing felt should be installed from the bottom of the roof in horizontal layers to
increase the water shedding ability of the felt. The initial layer of felt should be installed
to cover the bottom edge of the decking, from edge to edge. Overhang is not required.
Anchor the top corner of the felt after it has been properly positioned and roll the felt out
across the roof. Pay careful attention to roll.the felt out smoothly, avoiding wrinkles as
you move across the roof. The top edge of the felt should be fastened no less than every
eight inches. The middle and bottom edge should also be fastened no less than every
eight inches. Fasteners should be applied no less than every eight inches along the eaves.
The next.course of felt should also be aligned with the roof edge and should overlap the
previous course two inches (sometimes referred to as head lap). In the event you get to
the end of a roll prior to getting to the opposite edge of the roof, begin a new roll with a
four inch overlap over the end of the prior roll (sometimes referred to as end lap). The
same fastening pattern used on the middle and bottom of the initial course should be used
for each subsequent course. For the top of each subsequent course, fasten intermittently
to hold the top edge in place until the next course is applied. The fasteners in the bottom
of the next course will hold the top of the previous course securely.
Continue up the roof in this manner. Be sure to firmly fasten. the top of the final course if
it terminates at the top edge of the roof. Otherwise, overlap the felt over the ridge and
secure then begin at the bottom of the other side of the ridge and repeat the process.
In valleys, lay a vertical section of roofing felt the length of the valley prior to the
installation of the horizontal runs of roofing felt. If you use more than one section of
roofing felt in'a valley, be certain to start at. the bottom and overlap; each.. subsequent .
length a minimum of two inches as you move up the valley to stre�pttratea; .
shedding.
4..
.ti .wYi'y«P, .i:,t•' ��'i — niaii7..o.t. �?����r- fin.. ..
•,,...� - ::; a ..�.n-..a �.
In the event some wrinkles are created while fastening down a course of felt, slice the
wrinkles and fasten them flat to the deck. Then seal the cuts with waterproofing cement.
Installation of the primary roof covering (ex. Shingles) is recommended immediately
after :felt, installation:
".NOTE: LOCAL BUILDINO CODES'MAY REQUIRE A DIFFERENT FASTENING
PATTERN AND/OR SPECIFIC FASTENER TYPES THAN RECOMMENDED BY
THESE INSTRUCTIONS. PLEASE CONTACT YOUR LOCAL BUILDING CODE
ADMINISTRATOR FOR THE EXISTENCE OF REGIONALLY SPECIFIC
FASTENING REQUIREMENTS.
5' I
�tF+�r�' F112i
BCIS Home Log In ! User Registration Hot Topic Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
Flo(i �a
14Product Approval
.USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL20484-R1
Application Type Revision
Code Version 2017
Application Status Approved
IV
if
Comments
Archived ti 3
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910)483-0479 Ext 256
jstieby@unioncorrugating.com
Authorized Signature John Stieby
jstieby@unioncorrugating.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
13 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi, P.E.
!i Validation Checklist - Hardcopy Received
Certificate of Independence FL20484 R1 COI CertificateIndependence. odf
Referenced Standard and Year (of Standard) Standard
FM 4470
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2012
2003
2012
2006
4 r �
Product Approval Method Method 1 Option D
Date Submitted 08/23/2017
Date Validated 08/28/2017
Date Pending FBC Approval 09/01/2017
Date Approved 12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
20484.1
5V
Min 26 ga., 24" wide through fastened panel over 15/32" thick
plywood
Limits of Use :_
Approved for,usd in HVHZ- No
'Approvedt'for'use,outside;HVHZ: Yes
Installation Instructions
FL20484 R1 II EvaluationReportC2175 1.Ddf
Verified By: Bala Sockalingam, P.E. 62240
Impact 12esistant:'N%A'
Created by Independent Third Party: Yes
`Design Pressure: +N/A/-169
Evaluation Reports
Other: Uplift load of 71.0 psf @ fastener spacing of 24" o.c. &
FL20484 R1 AE EvaluationRegortC2175 S.pdf
169.0 psf @ fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.2
Advantage-Lok II
Min 26 ga., 16" wide concealed fastened panel over 7/16" thick
OSB & 15/32" & thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 RI II EvaluationReportC2175 2.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A I
Created by Independent Third Party: Yes
Design Pressure: +N/A/-116
Other: Maximum uplift load of 116.0 psf @ seam fastener
Evaluation Reports
FL20484 R1 AE EvaluationReportC2175 2.Ddf
spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA
rated plywood with retainer strap.
Created by Independent Third Party: Yes
20484.3
Aluminum Advantage-Lok II
Max 16.375" wide, nom 0.032" thick (min.) aluminum
concealed fastener roof panel over min 15/32" thick plywood
deck or 7/16" thick OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R3 II EvaluationReportC2175 3.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A '
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 22.5 psf at fastener spacing of 18.5" o.c.
FL20484 R3 AE EvaluationReportC2175 3.pdf
and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32"
Created by Independent Third Party: Yes
plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener
spacing of 4.63" o.c. with structural sealant in 15/32" plywood.
20484.4
Aluminum SL150
Max 16" wide, nom 0.032" thick (min.) aluminum snap -lock
standing seam metal panel over min 15/32" thick plywood
deck or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 Rl II EvaluationReportC2175 4.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-86
Evaluation Reports
Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and
FL20484 R1 AE EvaluationReportC2175 4.pdf
78.5 psf at clip spacing of 6" o.c. in 15/32" plywood or 7/16"
Created by Independent Third Party: Yes
OSB. Uplift load of 86.0 psf'at clip spacing of 6" o.c. with
structural sealant in 15/32" plywood.
20484.5
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32" thick
plywood or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 RI II EvaluationReportC2175 5.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c. &
FL20484 RI AE EvaluationReoortC2175 5.odf
124.0 psf @ fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.6
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32" thick
plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 RI II EvaluationReoortC2175 6.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A;.° Evaluation Repo�r
Other: Uplift load of 56 psf for Fastening System 1. Uplift load I FL20484 RS AE EvaluationReoortC2175 6.Ddf
of 88.5 psf for Fastening System 2. Created by Independent Third Party: Yes
20484.7
M1_350
Max 16.5" wide, min 24 ga. steel standing seam panel over
15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReDOrtC2175 7.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Maximum uplift load of 124 psf @ clip spacing of 6"
FL20484 R1 AE EvaluationReDOrtC2175 7.Ddf
D.C. with 180 seam, self -adhering membrane and fixed clip.
Created by Independent Third Party: Yes
20484.8
PBR or R Panel
Min 26 ga., 36" wide through fastened panel over 15/32" thick
plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReDOrtC2175 8.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161.5
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 48" D.C.
FL20484 RI AE EvaluationReoortC2175 8.Ddf
and 161.5 psf at fastener spacing of 6" D.C.
Created by Independent Third Party: Yes
20484.9
SL175
Max 18" wide, min 24 ga., snap -lock standing seam metal
panel over 15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReDOrtC2175 9.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c. and
FL20484 R1 AE EvaluationReoortC2175 9.pdf
78.6 psf @ clip spacing of 8" o.c with felt. Uplift load of 93.5
Created by Independent Third Party: Yes
psf @ clip spacing of 12" o.c. with self -adhering membrane.
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
Credit0
Safe
S2CUI'1C}'hiETRICS'
Kh1v
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
'26 GA. 5V PANEL'
FLORIDA BUILDING CODE 6TI3 EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 20484.1-R1
ROOFING
METAL ROOFING
Prepared For:
Union .Corrugating Company
701 S. King St.
Fayetteville, NC 29301
Telephone: (910) 483-0479
Fax: (910) 483-1091
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer ##62240
12:16 N Lansing Ave.,,S'uite`C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation• Details (1 Page)
Load Span Table (I Page)
Report No; C21754
-Date: 8.23.2017
m��taecaeea.a.�o�
ed��,eG �p,U N Gq
o cos
....,
�() " S E
y �•v 622� .,•¢
tl!
PLO
y
FL 20484.1-R1
- C2175-1
8.23.2017
Page 2 of 3
Manufacturer: Union Corrugating Company Wn
RIE Vi
Product Name: SV Panel
l
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Deck Description: Min. 15/32" thick APA rated plywood or min. 1/4" thick wood plank
(min SG of 0.42) for new and existing constructions. Designed by
others and installed as per FBC 2017.
New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Required for new construction.
Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 71.0 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) 169.0 psf @ fastener spacing of 6" o.c.
Panel Attachment: #10-15 x 2" long wood screw with washer
At interior @ max 12" o.c. across panel width through panel rib
At panel ends @ max 6" o.c. across panel width through panel flat and rib
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Union load span table. This evaluation report is
FL 20494.1-RI
C2175-1
8.23.2017
Page 3 of 3
-n('A applicable in High Velocity Hurricane Zone. Refer to current NOA
-"for-) use of this product in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
directory or ASTM E108/UL790 report from an accredited laboratory
for -fire ratings of this product.
Supporting Documents: UL580 & UL1897 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. TI 97-16, Reporting Date 5/12/16
PANEL OVERLAP
NEW UNDERLAYMENT PANEL FASTENER
ROOF PANEL SEE DETAIL 2 SEE DETAIL 1 SPACING PER ALLOWABLE
B
E
UPLIFT LOAD TABLE
n n ii
¢Fpp�
EXISTING UNDERIAYMEM SHINGLES PLYWOOD
EXISTING SDECK ATTACHMENT AND
15/32" THICK (MIN.)
(OPTIONAL) (OPTIONAL) SUPPORTS MUST BE
DESIGNED AND INSTALLED
BY OTHERS
MIN. 2X- WOOD RAFTER/JOIST/
TRUSS AT MAX. 24" O.C.
TYPICAL PANEL INSTALLATION X-SECTION
U
�n
m
Z �N�
#10-15 X 2" LONG WOOD
F NZN
SCREW WITH WASHER
cgi I
z
MIN 26 GA. PANEL
u vi�o
NEW UNDERLAYMENT
i nrn
EXISTING SHINGLES
Y
(OPTIONAL)
W
d
EXISTING UNDERLAYMENT PLYWOOD
(OPTIONAL) 15/32" THICK (MIN.)
c R
n �8$
d
DETAIL 1
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
qN
33
#10-15 X 2" LONG WOOD FLORIDA BUILDING CODE (FBC).
m e
SCREW WITH WASHER 2. ROOF PANELS SHALL BE MINIMUM 26 GA EFFECTIVE COVERING WIDTH OF
-
PANEL = 24".
g
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
82
MIN 26 GA. PANEL SPECIFIED ON THIS DRAWING.
NEW UNDERLAYMENT 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
_ _ _
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
EXISTING SHINGLES REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL
(OPTIONAL) 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
EXISTING UNDERIAYMEM PLYWOOD
(OPTIONAL) DETAIL 2 15/32" THICK (MIN.)
C2175-1
1 � 1
-.UNION CORRUGATING COMPAIN,
5V Panel Uplift Loads
(Min 26 ga.)
Description
Fastener Spacing
Allowable Uplift
"I along Panel Length
Load
(in)
(Psf)
ovbrig&width: 24"
6
169.0
... ..... .. .. ........ . .. . . ..... ..... . .. .... . ......
8
158.1
Panel Fasteners
10
147.2
#10- 15 hex head screws with
12
136.3
sealed washer
.. . ........
14
121.7
. . ... . .................... . .
16
106.5
Panel fasteners spaced at 12"
. . . . . ..... ... . . ... . .
18
. . ..... ....
94.7
o.c. across panel width
...... .. .. .... . .. . ..... .......... - .... . . . ........... . . ............ . . . . . ...... . ...... .
20 .
. .. . ..... .. ....... . .... ... . ........ ... . .
85.2
through ribs.
77.5
..... ..... .
22
24
71.0
1
Notes:
1. The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels inustb6 installed as per Evaluation Report Fl, 20484.1 and Union current installation procedure.
yPL1NQqj""r#
ro CC
M: 40
gc LLJ
0
L 0
4N
1216 N,Lansj4g Ave, Suite C
Tuisa,.Ok.74,106
918 492 5,992
Bala Sockalingarn, Ph.D:, R.E.
I FL 62240