Product Approval Menu > Product or Application Search > Application
FL #
Lis > Application Detail Lt
FL16048-R6
Application Type
Revision 90
Code Version
2017 ST. LUCIE COUNTY BUILDING
Application Status
Div SION
Approved REVIEWED FOR COMPLIANC
REVIEWED Y.
DATE
Comments
PLANS AN ERMTT M1 IST
MUS BE KEPT
Archived
N JOB
SITE OR NO INSPECTION(S) WILL BE
MADE
Product Manufacturer
Tri-Built Materials Group, LLC
Address/Phone/Email
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
david.ruiz@tribuiltmg.com
Authorized Signature
David Ruiz
david.ruiz@tribuiltmg.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, NJ 07073
(201) 842-2449
david.ruiz@tr*ibuiltmater'iaisgroup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Pr ofessional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Njeminen
Evaluation Report
Florida License
PE-59166 THESE PLANS AND ALL PROPOSED WORK
Quality Assurance Entity
UL LLC ARE SUBJECT TO ANY CORRECTIONS
Quality Assurance Contract Expiration Date
07/18/2020 REQUIRED BY FIELD INSPECTORS THAT
Validated By
John W. Knezevich, PE MAY BE NECESSARY IN ORDER TO
validation ChecklistCQMPdPYM&T%WdALL APPUCABLE CODES.
Certificate of Independence
Referenced Standard and Year (of Standard)
FL16048 R6 COI 2017 01 COI Nleminen.pdf
Standard
ASTM D1970
ASTM G155
FM 4474
FRSA/TRI April 2012 (04-12)
UL1897
Equivalence of Product Stand"NCEALED FASTENERiS OR AT—,ACHArFN—i S
Certified By ARE THE RESPONSIBILrrY OF THE
CONTRACTOR OR RECORD
Year
2015
2005
2011
2012
2012
FILE COPY
https://www.floridabuilding.org/prlpr�_app_dtl.aspx?param--wGEVXQwtDqtFPmdYiNDWrwipmtAnR8jv9FiYHTk4FLCxcqVtRhfvMw�/�3d�/�3d 1/2
2/23/2018
Florida Building Code Online
Sections from the Code
Product Approval Method Method I Option D
Date Submitted 09/25/2017
Date Validated 10/01/2017
Date Pending FBC Approval 10/03/2017
Date Approved 12/12/2017
....... . ..
�Mod 1, Number or Name w
e
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16048 R6 11 2017 09 FINAL ER TRI-
Approved for use outside HVHZ: Yes
BUILT UNDERLAYMENTS FL16048-R6.r)d
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use of
Evaluation Reports
foam -on tile systems overtop the self -adhering underlayment
FL16048 R6 AE 2017 09 FINAL ER TRI-
for one particular application. See ER Section 5.6.4 for details.
BUILT UNDERLAYMENTS FL16048-R6.pd
2.) Refer to ER Section 5 for other Limits of Use.
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FIL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(l),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 4SS, F.S., please click here .
Product Approval Accepts:
FW911 a] FORM K9 M
Credit Card
Safe
hftps://www.floridabuilding.org/prlpr�_app_dtl.aspx?param--wGEVXQwtDqtFPmdYiNDWrwipmtAnR8jv9F!YHTk4FLCxcqVtRhfvMw�/�3d�/�3d 2/2
ERD
TRINITY
EVALUATION REPORT
TRI-BUILT Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report A42960.10.12-116
FL16048-R6
Date of Issuance: 10/25/2012
Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6 th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4 ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/25/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity] ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITYIERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6 th Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
Conditions of Use set forth herein.
2. STANDARDS:
Section
1504.3.1
1504.3.1
1504.6
1507.2.4 / 1507.1.1, 1507.2.9.2
1507.3.3
3. REFERENCES:
Kntfty
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
UL, LLC. (QUA9625)
UL, LLC. (QUA9625)
4. PRODUCT DESCRIPTION:
Property
Wind Resistance
Wind Uplift
Accelerated Weathering
Physical Properties
Physical Properties
Examination
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Accelerated Weathering
Wind Resistance
Quality Control
Quality Control
Standard
FM 4474
UL 1897
ASTIVI G155
ASTM D1970
FRSA/TRI April 2012 (04-12)
Reference
S40540.02.13-1
S40540.11.13
S40540.03.14
S44870.04.14-2
S44870.04.14-3
S44870.04.14-1
S44870.04.14-4
S43530.02.14-1-RI
S43530.05.14
S40540.10.14
SC764S.02.IS
SC8520.04.15
SC14045.05.17-RI
Multiple -Listing R16814
Service Confirmation
Year
2011
2012
2005
2015
2012
Date
02/19/2013
11/19/2013
03/26/2014
04/02/2014
04/02/2014
04/10/2014
04/10/2014
05/14/2014
05/28/2014
10/31/2014
02/13/2015
05/27/2015
06/07/2017
12/10/2015
Exp.07/18/2020
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970 and FRSA/TRl April 2012.
4.3 Tri-Built. Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nierninen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6
Certificate ofAuthorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION F1.16048-116
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6:09/25/2017
Page 2 of 6
T -ry'
RIN i ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
'.TABLE1:,,RooF_C vE'
0 R OPTIONS
Underlayment
Asphalt
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
Slate
Shingles
& Shingles
Tri-Built Sand-R SA Shingle
Yes
No
No
No
Yes
Yes
Underlayment
Tri-Built S/A HT TU
Yes
Yes
Yes
Yes
Yes
Yes
Underlayment
See 5.5.1
Tri-Built Smooth HT S/A
Yes
No
No
Yes
Yes
Yes
Underlayment
I
I
I
I
I
I I
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
LE DH DERLAYM KBINATI NSv"
AfiLE1A.ALL6WA'BLE",T-i "A " Esm./'UN Ehi(tlb 0
Adhesive
Florida Product Approval
Underlayments
ICP Adhesives PolysetO AH-160
FL6332
Tri-Built S/A HT TU Underlayment
Dow TileBond—
FL22525
Tri-Built S/A HT TIJ Underlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-ft SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Bullt Smooth HT S/A
Underlayment applied to:
> Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
> Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
I Refer to Tile Manufacturer's or Adhesive Manufocturer's Florida Product Approvalfor Overturning Moment Resistance Performance.
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6:09/25/2017
Page 3 of 6
TRINITYIERD
5.6.3 Bond to Mechanically Attached Base LaVer:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
> ASTM D226, Type I or 11 felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure = -45.0 Ps :
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure = -67.5 ps :
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure = -150.0 osf:
Deck: Min, 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be remov'ed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Design Pressure = -60.0 Dsf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6
Certificate ofAuthorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION FL26048-116
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6:09/25/2017
Page 4 of 6
TRINITY I ERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone I
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPIRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TLI Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
-TABUE,2:',TIi'1E SILIPPAGEtIMITATIONS FORDIREcr-DECK TILE INSTALLATIONS
Maximum
Underlayment
Tile Profile
Staging Method
Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high
6:12
on slope, as shown below)
Tri-Built S/A HTTU
Underlayment
Lugged
C
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certiflcate ofAutharization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6:09/25/2017
Page 5 of 6
TRINI I y 1 ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment. Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Tri-Built S/A HT TU UnderlaVment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table I herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANuFAcrURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
LIL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-116
Certificate ofAuthorization #9503 EDITION (2017) F13C NON-HVHZ EVALUATION F1.16048-116
TRI-BUILT Roof UnderlaVinents, (800) 516-1485 Revision 6:09/25/2017
Page 6 of 6
7-1
a
User Registration HotTopics
BCIS Home Log In Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
dbprFlorida
Product Approval
USER: Public User
0-12 0-IN,
Product Approval Meng > Product or Application Search > Application Lis > Application Detail
FL # FL20484-RI
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 483-0479 Ext 256
jstieby@unioncorrugating.com
Authorized Signature John Stieby
jstieby@unioncorrugating.com
Technical Representative
Address/ Phone/Em ai I
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
t�; Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi, RE.
!Z Validation Checklist - Hardcopy Received
Certificate of Independence FL20484 RI COI Certificatelndependence.nd
Referenced Standard and Year (of Standard) Standard Year
FM 4470 2012
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
4.
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
08/23/2017
08/28/2017
09/01/2017
12/12/2017
FL *
I Model, Number or Nam e
Description
20484.1
5V
Min 26 ga., 24" wide through fastened panel over 15/32" thick
plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 RI II Eva I uation ReportC2175 I.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, RE. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-169
Evaluation Reports
Other: Uplift load of 71.0 psf @ fastener spacing of 24" o.c. &
FL20484 RI AE EvaluationReportC2175 1.Dd
169.0 psf @ fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.2
)e-Lok II
Min 26 ga., 16" wide concealed fastened panel over 7/16" thick
OSB & 15/32" & thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReportC2175 2.pd
Approved for� use outside HVHZ: Yes
Verified By: Bala Sockalingam RE. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-116
Evaluation Reports
Other: Maximum uplift load of 116.0 psf @ seam fastener
FL20484 R1 AE Eva I uation ReoortC2175 2.pd
spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA
Created by Independent Third Party: Yes
rated plywood with retainer strap.
20484.3
Aluminum Advantage-Lok II
Max 16.375" wide, nom 0.032" thick (min.) aluminum
concealed fastener roof panel over min 15/32" thick plywood
deck or 7/16" thick OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II Eva lu ationReoortC2 175 3.i)df
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam RE. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 22.5 psf at fastener spacing of 18.5" o.c.
FL20484 R1 AE EvaluationReportC2175 3.Ddf
and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32"
Created by Independent Third Party: Yes
plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener
spacing of 4.63" o.c. with structural sealant in 15/32" plywood.
20484.4
Aluminu SL150
Max 16" wide, nom 0.032" thick (min.) aluminum snap -lock
standing seam metal panel over min 15/32" thick plywood
deck or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 III II EvaluationReportC2175 4.pd
Approved for use outside HVIHIZ: Yes
Verified By: Bala Sockalingam RE. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-86
Evaluation Reports
Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and
FL20484 RI AE EvaluationReportC2175 4.Dd
78.5 psf at clip spacing of 6" o.c. In 15/32" plywood or 7/16"
Created by Independent Third Party: Yes
OSB. Uplift load of 86.0 psf at clip spacing of 6" o.c. with
structural sealant in 15/32" plywood.
I20484.5 MasterRIb Min 29 ga., 36" wide through fastened panel over 15/32" thick
I I plywood or 7/16" thick OSB I
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II Eva I uation ReportC2175 5.odf
Approved for use outside HVIHIZ: Yes
Verified By: Bala Sockalingam, RE. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c. &
FL20484 RI AE EvaluationRer)ortC2175 5.pd
124.0 psf @ fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.6
MasterRib
I
Min 29 ga., 36" wide through fastened panel over 15/32" thick
I
plywood
Limits of Use Installation Instructio
Approved for use in HVIHIZ: No FL204 OA RI II Eva luatZsn ReportC2 175 6.1)d
Approved for use outside HVIHIZ: Yes Verified By: Bala Sockalingam, RE. 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-88.5 1 Evaluation Reports
Other: Uplift'load of 56 psf for Fastening System 1. Uplift load FL20484 R1 AE Evaluation ReportC217 5 6.pd
of 88.5 psf for Fastening System 2. Created by Independent Third Party: Yes
1
20484.7
ML150
Max 16.5" wide, min 24 ga. steel standing seam panel over
15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 RI II EvaluationReportC2175 7.Dd
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, RE. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Maximum uplift load of 124 psf @ clip spacing of 6"
FL20484 RI AE EvaluationRer)ortC2175 7,Od
D.C. with 180 seam, self -adhering membrane and fixed clip.
Created by Independent Third Party: Yes
1
20484.8
PER or R Panel
Min 26 ga., 36" wide through fastened panel over 15/32" thick
I
plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II Evaluation ReDortC2 175 8.Dd
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam RE. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161.5
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 48" D.C.
FL20484 R1 AE Eva I uation ReDortC2175 8.pdF
and 161.5 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.9
SL175
Max 18" wide, min 24 ga., snap -lock standing seam metal
panel over 15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 11 Evaluation ReportC2175 9.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, RE. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 39.8 psf @ clip spacing of 36" D.C. and
FL20484 RI AE EvaluationRer)ortC2175 9.pd
78.6 psf @ clip spacing of 8" o.c with felt. Uplift load of 93.5
Created by Independent Third Party: Yes
psf @ clip spacing of 12" o.c. with self -adhering membrane.
E9 F_,_�
Contact Us :: 2601 Blair Stone Road. Tallahassee FIL 32399 Phone: 850-487-1824
The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statement :: Refund Statemen
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
EM M 11--ii2l R9 bMw
Credit 'Card
Safe
securftymEr,77
I S.
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
'26 GA. 5V PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 20484.1-RI
ROOFING
METAL ROOFING
Prepared For:
Union Corrugating Company
701 S. King St.
Fayetteville, NC 28301
Telephone: (910) 483-0479
Fax: (910) 483-1091
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing, Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Instaflation Details (1 Page)
Load Span Table (1 Page)
Report -No. C2175-1
Date: 8.23.2017
.." 'I 14 3 9 a 11 11 '704,? 10�
�jLl N G144f
S E,
O�-
0 - 0
FL20484.1-RI
C2175-1
8.23.2017
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Deck Description: Min. 15/32" thick APA rated plywood or min. 3/4" thick wood plank
(min SG of 0.42) for new and existing constructions. Designed by
others and installed as per FBC 2017.
New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Required for new construction.
Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: .71.0 psf @fastener spacing of 24" o.c.
(Factor of Safety = 2) 169.0 psf @ fastener spacing of 6" o.c.
Panel Attachment: #10- 15 x 2" long wood screw with washer
At interior @ max 12" o.c. across panel width through panel rib
At panel ends @ max 6" o.c. across panel width through panel flat and rib
Test Standards: Roof assembly tested in accordance with UL580-06 'Uplift Resistance
of Roof Assemblies' & LTL1897-04 'Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Union load span table. This evaluation report is
FL20484.1-Rl
C2175-1
8.23.2017
Page 3 of 3
not applicable in High Velocity Hurricane Zone. Refer to current NOA
for use of this product in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
directory or ASTM E108/UL790 report from an accredited laboratory
for fire ratings of this product.
Supporting Documents: UL580 & UL1897 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T197-16, Reporting Date 5/12/16
PANEL OVER
NEW UNDERLAYMENT
ROOF PANEL DETAIL 2
PANEL FASTENER
SEE DETAIL 1 SPACING PER ALLOWABLE
'4� UPLIFT LOAD TABLE
v
\\-DECK
i i
EXISTING UNDERLAYMENT EXISTING SHINGLES
ATTACHMENT AND PLYWOOD
15/32' THICK (MIN.)
v
(OPTIONAL) (OPTIONAL)
SUPPORTS MUST BE
DESIGNED AND INSTALLED
BY OTHERS
-MIN. /A- WUUU I%ArttN/JUIW/
TRUSS AT MAX. 24" O.C.
#10-15 X 2- LONG WOOD
SCREW WITH WASHER
NEW UNDERLAYMENT
EXISTING UNDERLAYMENT
(OPTIONAL)
DETAIL 1
#10-15 X 2- LONG WOOD
SCREW WITH WASHER
NEW UNDERLAYMENT
EXISTING UNDERLAYMENT v
(OPTIONAL) DETAIL 2
TYPICAL PANEL INSTALLATION X-SECTION
MIN 26 GA. PANEL
EXISTING SHINGLES
(OPTIONAL)
PLYWOOD
15/32- THICK (MIN.)
MIN 26 GA. PANEL
EXISTING SHINGLES
(OPTIONAL)
PLYWOOD
15/32" THICK (MIN.)
Lj
0
s
Ed
a.
a..
z
§
GENERAL NOTES
z
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUI LDING CODE (FBC).
2. ROOF PANELS SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH OF
wol
cn
PANEL = 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/`TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
.2;
T1
OF
UNION CORRUGATING COMPANY
5V Panel Uplift Loads
(Min 26 ga.)
Description
Fastener Spacing
along Panel Length
(in)
Allowable Uplift
Load
(psf)
Coverage width: 24"
6
. . ........... .....
. . ....
158.1
Panel Fasteners
10
147.2
# 10- 15 hex head screws with
12
136.3
sealed washer
14
121.7
16
1,06.5
Panel fasteners spaced at 12"
18
94.7
o.c. across panel width
20
85.2
through ribs.
77 - .5
... . ......
22 ....... . . .. .
24
71.0
Notes:
1. The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 20484.1 and Union current installation procedure.
121.6 N Lansing Ave., Suite C
Tulsa, Ok 74106
9184925992
%0tM111111 I J"#j'
XLINGj o�
Vj 14 S S
00
0
LU
LLJ
O�-
PLO
0
S1 ELI
'Z, 3 - -2-
Bala Sockalingam, Ph.D., P.E.
FL 62240
Florida Building Code Online
Page I of 2
"W1
BCIS Home Log In User Registration Hot Topics
Submit Surcharge Stats Facts
Publications FBC Staff I BCIS Site Map Links Search i
d
FM.dzi
Product Approval
bL
USER: Pubilc User
r
"
Product Approval Menu > Application Detail
FL #
FL5293-1128
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived 13
Product Manufacturer
GAF
Address/Phone/Email
1 Campus Drive
Parisppany, NJ 07054
(800) 766-3411
mstieh@gaf.com
Authorized Signature
Robert Nienninen
lindar@nemoetc.com
Technical Representative
William Broussard
Address/Phone/Email
1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
Technica]QuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Single Ply Roof Systems
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
11 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Nleminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
10/18/2018
Validated By
John W. Knezevich, PE
10 Validation Checklist - Hardcopy Received
Certificate of Independence FL5293 R28 COI 2018 01 COI NIEMINEN.Dd
Referenced Standard and Year (of Standard) Standard
YSPE
ASTM D6878
2011
FM 4470
2012
FM 4474
2011
TAS 114
2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/p�_app_dtl.aspx?param=wGEVXQwtDquwVcULes7wT... 4/10/2018
Florida Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
r- I
Method 1 Option D
02/09/2018
02/10/2018
02/14/2018
04/10/2018
FIL *
Model, Number or Name
Description
5293.1
EverGuard TPO Single -Ply Roof
Single -ply, thermoplastic polyolefin roofing systems
Membrane Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5293 R28 11 2018 01 FINAL Al ER GAF EG
TPO FL5293-R28.od
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-502.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted In this application
Evaluation Reports
relates to one specific assembly in the ER Appendix. Refer to
FL5293 R28 AE 2018 01 FINAL ER GAF EG
the ER Appendix for all systems and associated max. design
TPO FL5293-R28 Pdf
pressures. 2.) Refer to ER Section 5 for Limits of Use
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FIL 32399 Phone, OSO-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida, :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.27S(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personall address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click h_qM.
Product Approval Accepts:
M t we� N F_ H � M
Credit Card
I Safe
http://www.floridabuilding.org/pr/pr_app_Atl.aspx?param=wGEVXQwtDquwVcULes7wT... 4/10/2018
NEMO I etc.
Certificate of/luthorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
GAF Evaluation Report 01506.09.05-1129
1 Campus Drive FL5293-R28
Parsippany, NJ 07054 Date of Issuance: 11/09/2005
(800) 766-3411 Revision 29: 01/30/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6 1h Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: EverGuardO TPO Single -Ply Roof Membrane Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the -referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s), the Quality Assurance or the production facility location(s). NEIVIO I etc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6, plus a 97-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4 ANE1983
The facsimile sea] appearing was authorized by Robert
Nieminen, P.E. on 01/30/2018. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOJetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEM-0 I etc.
ROOFING SYSTEms EVALUATION:
1. SC6PE:
Product Category:
Roofing
Sub -Category:
Single Ply Roof Systems
Compliance Statement:
EverGuard0l TPO
Single -Ply
Roof Membrane
Systems,
as produced
by GAF, have
demonstrated compliance
with the following sections of
the 6th Edition (2017) Florida
Building Code
through testing
in accordance with
the following
Standards. Compliance
is subject to the Installation Requirements and
Limitations
Conditions of Use set forth
herein.
1. STANDARDS:
Section
Prope
Standard
Year
1504.3.1
Wind
FIVI 4474
2011
1504.7
Impact
FIVI 4470
2012
1507.13.2
Physical Properties
ASTIVI D6878
2011
1523.6.2
Wind
TAS114
2011
3. REFERENCES:
Kafint
Exam
Reference
Date
Exam
Reference
Date -
ACRC (TST4671)
TAS114
06-035
10/18/2006
FM App (TST1867)
FM 4474
797-08873-267
11/26/2013
ACRC (TST4671)
TAS114
07-005
01/17/2007
FM App (TST1867)
FM 4474
3G48066
12/13/2013
ACRC (TST4671)
TAS114
07-024
03/01/2007
FM App (TST1867)
FM 4474
3041749
12/30/2013
ACRC (TST4671)
TAS114
07-016
04/19/2007
FM App (TST1867)
FM 4474
797-09116-267
01/24/2014
ACRC (TST4671)
TAS114
07-017
04/19/2007
FM App (TST1867)
FM 4474
797-09234-267
03/11/2014
ACRC (TST4671)
TA5114
07-025
05/02/2007
FM App (TST1867)
FM 4474
797-09317-267
04/18/2014
ACRC (TST4671)
TAS114
07-026
05/03/2007
FM App (TST1867)
FM 4474
797-09493-267
05/27/2014
ACRC (TST4671)
TAS114
07-027
05/04/2007
FM App (TST1867)
FM 4474
797-09495-267
05/27/2014
ACRC (TST4671)
TAS114
07-042
08/31/2007
FM App (TST1867)
FM 4474
797-09573-267
06/13/2014
ACRC (TST4671)
TAS 114
07-043
09/05/2007
FM App (TST1867)
FM 4474
797-09497-267
06/23/2014
ACRC (TST4671)
TAS 114
07-045
09/06/2007
FM App (TST1867)
FM 4474
797-09594-267
06/24/2014
ACRC (TST4671)
TAS 114
07-046
09/06/2007
FM App (TST1867)
FM 4474
797-09635-267
07/16/2014
ACRC (TST4671)
TAS 114
07-048
09/07/2007
FM App (TST1867)
FM 4474
797-09892-267
10/30/2014
ACRC (TST4671)
TAS 114
07-049
09/10/2007
FM App (TST1867)
FM 4474
797-10123-283
12/17/2014
ACRC (TST4671)
TAS 114
07-080
01/03/2008
FM App (TST1867)
FM 4474
797-10153-267
12/19/2014
ACRC (TST4671)
TAS 114
08-022
04/17/2008
FM App (TST1867)
FM 4474
797-10210-267
02/05/2015
ACRC (TST4671)
TAS 114
08-030
04/05/2008
FM App (TST1867)
FM 4474
797-10211-267
02/05/2015
ACRC (TST4671)
TAS 114
08-023
04/17/2008
FM App (TST1867)
FM 4474
797-10212-267
02/05/2015
ACRC (TST4671)
TAS 114
08-033
04/19/2008
FM App (TST1867)
FM 4474
797-RR20018
02/23/2015
ACRC (TST4671)
TAS 114
08-032
04/1912008
FM App (TST1867)
FM 4474
RR200320
04/07/2015
ACRC (TST4671)
TAS114
11-004
03/21/2011
FM App (TST1867)
FM 4474
RR200321
04/07/2015
ACRC (TST4671)
TAS114
11-011
03/24/2011
FM App (TST1867)
FM 4474
3055411
04/15/2015
ACRC (TST4671)
TAS114
11-012
04/06/2011
FM App (TST1867)
FM 4474
3047636 - LTR
06/24/2015
ACRC (TST4671)
TAS114
11-013
04/06/2011
FM App (TST1867)
FM 4474
RR202913
11/19/2015
ACRC (TST4671)
TAS114
11-019
04/08/2011
FM App (TST1867)
FM 4474
3053501
01/14/2016
ACRC (TST4671)
TA5114
11-020
04/08/2011
FM App (TST1867)
FM 4474
3055167
02/10/2016
ACRC (TST4671)
TAS114
11-021
04/11/2011
FM App (TST1867)
FM 4474
RR204005
04/13/2016
ACRC (TST4671)
TAS114
11-040
08/05/2011
FM App (TST1867)
FM 4474
RR205159
05/05/2016
ACRC (TST4671)
TAS114
11-041
08/05/2011
FM App (TST1867)
FM 4474
RR205192
05/09/2016
ACRC (TST4671)
TAS114
11-056
09/30/2011
FM App (TST1 * 867)
FM 4474
RR205233
06/15/2016
ACRC (TST4671)
TAS114
12-008
04/10/2012
FM App (TST1867)
FM 4474
RR205946
07/22/2016
ACRC (TST4671)
TAS114
12-012
04/23/2012
FM App (TST1867)
FM 4474
RR205474
08/31/2016
ACRC (TST4671)
TAS114
12-013
04/23/2012
FM App (TST1867)
FM 4474
RR206198
09/01/2016
ACRC (TST4671)
TAS114
12-014
04/2312012
FM App (TST1867)
FM 4474
RR206353
09/07/2016
ACRC (TST4671)
TAS114
12-016
04/24/2012
FM App (TST1867)
FM 4474
RR206620
09/12/2016
ACRC (TST4671)
TAS114
12-019
04/25/2012
FM App (TST1867)
FM 4474
RR206351
10/21/2016
ACRC (TST4671)
TAS114
12-024
05/09/2012
FM App (TST1867)
FM 4474
3055491
12/05/2016
ACRC (TST4671)
TAS114
12-025
05/09/2012
FM App (TST1867)
FM 4474
3058483
12/09/2016
ACRC (TST4671)
TAS114
12-029
05/23/2012
FM App (TST1867)
FM 4474
30S6728 LTR
12/23/2016
ACRC (TST4671)
TAS114
12-030
05/2312012
FM App (TST1867)
FM 4470
3056822 LTR
01/04/2017
ACRC (TST4671)
TAS114
11-042-RI
01/27/2012
FM App (TST1867)
FM 4474
RR208456
02/13/2017
ACRC (TST4671)
TAS114
12-033
08/10/2012
FM App (TST1867)
FM 4474
3061218
05/10/2017
ACRC (TST4671)
TAS114
12-036
08/13/2012
FM App (TST1867)
FM 4474
3061218 LTR
05/16/2017
ACRC (TST4671)
TAS114
12-018-RI
01/30/2013
FM App (TST1867)
FM 4474
RR209927
06/23/2017
ACRC (TST4671)
TAS114
08-022-Rl
01/15/2015
FM App (TST1867)
FM 4474
RR210305
07/13/2017
NEMO ETC, LILC
Evaluation Report 01506.09.05-1129
Certificate ofAuthorization #32455
6' EDITION
(2017) FBC NON-HVHZ EVALUATION
FIL5293-1128
GAF EverGuardO
TPO Single -Ply Roof Membrane Systems
Revision 29: 01/30/2018
Page 2 of 6
ONEMO I etc.
Exam Reference Date kafty Exam Reference Date
ACRC (TST4671) TAS 114 11-056-R2 01/23/2015 IRT(TST7408) TAS 114 02-008 01/18/2002
ACRC (TST4671) TAS 114 16-002 03/04/2016 IRT(TST7408) TAS 114 03-0728 02/17/2004
ATI (TST1558) TAS 114 H-3320.01-109-44 08/10/2017 IRT(TST7408) TAS 114 04-012 02/18/2004
AT] (TST1558) TAS 114 H-3314.01-109-44 08/14/2017 IRT(TST7408) TAS 114 04-019 04/26/2004
ATI (TST1558) TAS 114 H-3315.01-109-44 08/14/2017 PRI (TSTS878) Physicals GAF-373-02-01 10/15/2012
AT[ (TST1558) TAS 114 H-3317.01-109-44 08/14/2017 PRI (TSTS878) FM 4474 GAF-043-02-03 09/16/2013
ATI (TST1558) TAS 114 H-3318.01-109-44 08/14/2017 PRI (TST5878) FM 4474 GAF-043-02-04 09/16/2013
ATI (TST1558) TAS 114 H-0730.01-109-44 08/16/2017 PRI (TSTS878) Physicals GAF-421-02-01 10/22/2013
ERD (TST6049) TAS 114 SC8580.11.15-4 11/09/2015 PRI (TST5878) Physicals GAF-422-02-01 10/22/2013
ERD (TST6049) FM 4474 SC8580.11.15-2 11/18/2015 PRI (TST5878) Physicals GAF-424-02-01 11/11/2013
ERD (TST6049) Criticality SC16505.17 09/22/2017 PRI (TST5878) Physicals GAF-425-02-01 11/11/2013
ERD (TST6049) FM 4474 SC16825.12.17-1 12/31/2017 PRI (TST5878) Physicals GAF-462-02-02 11/18/2013
F-TEC (TST7393) TAS 114 08-050183 06/26/2008 PRI (TST5878) FM 4474 GAF-457-02-02 01/20/2014
F-TEC (TST7393) TAS 114 08-050184 06/26/2008 PRI (TST5878) FM 4474 GAF-457-02-04 01/24/2014
F-TEC (TST7393) TAS 114 08-070133 08/04/2008 PRI (TST5878) FM 4474 GAF-457-02-06 01/24/2014
F-TEC (TST7393) TAS 114 08-050185 10/14/2008 PRI (TST5878) FM 4474 GAF-457-02-07 01/24/2014
F-TEC (TST7393) TAS 114 08-072805 02/16/2009 PRI (TST5878) FM 4474 GAF-457-02-08 01/24/2014
FM App (TST1867) FM 4470 3003617 12/20/1999 PRI (TSTS878) Physicals GAF-423-02-01 01/27/2014
FM App (TST1867) FM 4470 3009026 06/18/2002 PRI (TSTS878) Physicals GAF-426-02-01 01/27/2014
FM App (TST1867) FM 4470 3013861 03/28/2003 PRI (TST5878) Rupture GAF-435-02-01 01/29/2014
FM App (TST1867) FM 4470 3014692 08/05/2003 PRI (TSTS878) FM 4474 GAF-435-02-07 01/29/2014
FM App (TST1867) FM 4470 3014955 01/22/2004 PRI (TST5878) FM 4474 GAF-435-02-08 01/29/2014
FM App (TST1967) FM 4470 3012721 02/11/2004 PRI (TST5878) FM 4474 GAF-435-02-09 01/29/2014
FM App (TST1867) FM 4470 3015029 02/19/2004 PRI (TST5878) FM 4474 GAF-435-02-10 01/29/2014
FM App (TST1867) FM 4470 3015578 03/12/2004 PRI (TST5878) FM 4474 GAF-435-02-11 02/29/2014
FM App (TST1867) FM 4470 3020588 03/24/2004 PRI (TST5878) FM 4474 GAF-506-02-06 03/06/2014
FM App (TST1867) FM 4470 3019881 03/20/2004 PRI (TST5878) FM 4474 GAF-506-02-08 03/06/2014
FM App (TST1867) FM 4470 3016068 04/02/2004 PRI (TST5878) FM 4474 GAF-506-02-20 03/06/2014
FM App (TST1867) FM 4470 3013861 05/21/2004 PRI (TST5878) FIVI 4474 GAF-510-02-02 04/08/2014
FM App (TST1867) FM 4470 3105578 05/12/2004 PRI (TST5878) FM 4474 GAF-51D-02-04 04/08/2014
FM App (TST1867) FM 4470 3014955 01/28/2005 PRI (TST5878) FM 4474 GAF-510-02-05 04/08/2014
FM App (TST1867) FM 4470 3022136 03/17/2005 PRI (TST5878) FM 4474 GAF-511-02-02 04/08/2014
FM App (TST1867) FM 4470 3020681 09/01/2005 PRI (TST5878) FM 4474 GAF-506-02-11 04/14/2014
FM App (TST1867) FM 4470 3024051 03/28/2006 PRI (TST5878) FM 4474 GAF-506-02-12 04/14/2014
FM App (TST1867) FM 4470 797-02093-267 04/26/2006 PRI (TST5878) FM 4474 GAF-506-02-13 04/14/2014
FM App (TST1867) FM 4470 3023458 07/18/2006 PRI (TST5878) FM 4474 GAF-506-02-14 04/14/2014
FM App (TST1867) FM 4470 3028039 09/11/2006 PRI (TST5878) FM 4474 GAF-506-02-01 04/22/2014
FM App (TST1867) FM 4470 3027159 10/03/2006 PRI (TSTS878) FM 4474 GAF-514-02-01 05/12/2014
FM App (TST1867) FM 4470 3026149 02/05/2CO7 PRI (TST5878) FM 4474 GAF-514-02-03 05/12/2014
FM App (TST1867) FM 4470 3026964 07/25/2007 PRI (TST5878) FM 4474 GAF-514-02-04 05/12/2014
FIVI App (TST1867) FM 4470 3028857 11/02/2007 PRI (TSTS878) FM 4474 GAF-514-02-05 05/12/2014
FM App (TST1867) FM 4470 3030199 11/05/2007 PRI (TST5878) FM 4474 GAF-514-02-07 05/12/2014
FM App (TST1867) FM 4470 3030813 11/05/2007 PRI (TST5878) FM 4474 GAF-514-02-08 05/12/2014
FM App (TST1867) FM 4470 3031262 11/30/2007 PRI (TSTS878) FM 4474 GAF-516-02-01 05/13/2014
FM App (TST1867) FM 4470 3030292 02/25/2008 PRI (TST5878) FM 4474 GAF-516-02-03 05/13/2014
FM App (TST1867) FM 4470 797-03825-267 07/21/2008 PRI (TST5878) FM 4474 GAF-516-02-02 06/06/2014
FM App (TST1867) FM 4470 3033314 08/26/2008 PRI (TST5878) FM 4474 GAF-525-02-02 06/23/2014
FM App (TST1867) FM 4470 3034749 10/16/2008 PRI (TST5878) FIVI 4474 GAF-525-02-03 06/23/2014
FM App (TST1867) FM 4470 3032856 11/24/2008 PRI (TSTS878) FM 4474 GAF-462-02-09 07/01/2014
FM App (TST1867) FM 4470 3033135 11/24/2008 PRI (TST5878) FM 4474 GAF-462-02-10 07/01/2014
FM App (TST1867) FM 4470 3033862 12/24/2008 PRI (TST5878) FIVI 4474 GAF-462-02-11 07/01/2014
FM App (TST1867) FM 4470 3034394 02/27/2009 PRI (TST5878) FM 4474 GAF-524-02-02 07/01/2014
FM App (TST1867) FM 4470 3033121 04/13/2009 PRI (TST5878) FM 4474 GAF-524-02-03 07/01/2014
FM App (TST1867) FM 4470 3035300 05/06/2009 PRI (TST5878) FM 4474 GAF-524-02-05 07/01/2014
FM App (TST1867) FM 4470 3036614 06/09/2009 PRI (TST5878) FM 4474 GAF-540-02-02 08/06/2014
FM App (TST1867) FM 4470 3034310 06/15/2009 PRI (TST5878) FM 4474 GAF-540-02-03 08/06/2014
FM App (TST1867) FM 4470 3036141 08/10/2009 PRI (TST5878) FM 4474 GAF-540-02-04 08/06/2014
FM App (TST1867) FM 4470 3037820 04/30/2010 PRI (TST5878) FM 4474 GAF-538-02-02 08/13/2014
FM App (TST1867) FM 4470 797-059797-267 08/18/2010 PRI (TST5878) FM 4474 GAF-538-02-03 08/13/2014
FM App (TST1867) FM 4470 3038215 09/02/2010 PRI (TST5878) FIVI 4474 GAF-532-02-01 08/22/2014
FM App (TST1867) FM 4470 797-06003-267 11/11/2010 PRI (TST5878) FM 4474 GAF-524-02-05 08/27/2014
FM App (TST1867) FM 4470 3038318 12/10/2010 PRI (TST5878) FM 4474 GAF-549-02-01 08/08/2014
FM App (TST1867) FM 4470 797-06178-267 02/07/2011 PRI (TST5878) FM 4474 GAF-538-02-04 09/02/2014
FM App (TST1867) FM 4470 3040234 02/23/2011 PRI (TST5878) FM 4474 GAF-559-02-11 10/16/2014
FM App (TST1867) FM 4470 3040377 03/08/2011 PRI (TSTS878) FM 4474 GAF-559-02-12 10/16/2014
FM App (TST1867) FM 4470 3041685 03/24/2011 PRI (TST5878) FM 4474 GAF-559-02-13 10/16/2014
FM App (TST1867) FM 4470 797-06254-267 03/24/2011 PRI (TST5878) FM 4474 GAF-559-02-14 10/16/2014
FM App (TST1867) I'M 4470 3041535 06/08/2011 PRI (TST5878) FM 4474 GAF-559-02-15 10/16/2014
FM App (TST1867) FM 4470 797-06537-267 06/13/2011 PRI (TST5878) FM 4474 GAF-559-02-16 10/16/2014
FM App (TST1867) FM 4470 797-06538-267 06/13/2011 PRI (TST5878) FM 4474 GAF-559-02-18 10/16/2014
NEMO ETC, LLC Evaluation Report 01506.09.05-R29
Certificate ofAuthorization #32455 EDITION (2017) FBC NON-HVHZ EVAWATION FL5293-R28
GAF EverGuard" TPO Single -Ply Roof Membrane Systems Revision 29- 01/30/2018
Page 3 of 6
NNEMO I etc.
Ex6rn Referenc'er , Date Exam Reference Date
I'M App (TST1867) I'M 4470 3041746 08/27/2011 PRI (TSTS878) I'M 4474 GAF-538-02-05 12/03/2014
Fly! App (TST1867) I'M 4470 797-06894-267 11/02/2011 PRI (TST5878) Physicals GAF-584-02-01 12/07/2015
FM App (TST1867) I'M 4470 3038278 11/18/2011 PRI (TST5878) Physicals GAF-585-02-01 12/07/2015
FM App (TST1867) FM 4470 3042905 01/10/2012 PRI (TSTS878) Physicals GAF-586-02-01 12/07/2015
FM App (TST1867) Fly! 4470 797-07041-267 02/27/2012 PRI (TSTS878) FIVI 4474 GAF-453-02-05 05/06/2016
FM App (TST1867) FIVI 4470 797-07183-267 03/01/2012 PRI (TST5878) FM 4474 GAF-453-02-09 05/06/2016
FIVI App (TST1867) Fly! 4470 3044SO6 03/28/2012 PRI (TST5878) Physicals GAF-653-02-01 10/20/2016
I'M App (TST1867) FM 4470 797-07331-267 04/13/2012 PRI (TST5878) FM 4474 GAF-653-02-04 10/20/2016
FM App (TST1867) FM 4470 3044862 05/11/2012 PRI (TST5878) FM 4474 GAF-746-02-01 12/14/2016
I'M App (TST1867) FM 4470 797-07455-267 05/31/2012 PRI (TSTS878) FM 4474 GAF-746-02-02 12/14/2016
Fly! App (TST1867) Fly! 4470 797-07474-267 06/11/2012 PRI (TST5878) FM 4474 GAF-746-02-05 12/14/2016
I'M App (TST1867) FIVI 4470 797-07476-267 06/21/2012 PRI (TST5878) FIVI 4474 GAF-746-02-06 12/14/2016
FM App (TST1867) FM 4470 3045789 07/12/2012 PRI (TSTS878) I'M 4470 GAF-755-02-01 02/02/2017
FM App (TST1867) FM 4470 3045863 08/16/2012 PRI (TST5878) I'M 4474 GAF-755-02-02 02/02/2017
FM App (TST1867) FM 4470 3041749 08/23/2012 PRI (TSTS878) FM 4474 GAF-755-02-03 02/02/2017
FM App (TST1867) FIVI 4470 3046328 09/13/2012 PRI (TSTS878) FIVI 4474 GAF-755-02-04 02/02/2017
FIVI App (TST1867) FM 4470 3041769 09/27/2012 PRI (TSTS878) Physicals GAF-700-02-01 03/10/2017
FIVI App (TST1867) FM 4470 797-07744-267 10/17/2012 PRI (TST5878) FM 4474 GAF-782-02-02 08/30/2017
FM App (TST1867) FM 4470 797-07885-267 11/21/2012 PRI (TST5878) FM 4474 GAF-776-02-02 10/04/2017
FM App (TST1867) FM 4470 3046054 12/21/2012 PRI (TST5878) Criticality GAF-793-02-01 12/08/2017
FM App (TST1867) FM 4470 797-08216-267 04/1V2013 PRI (TST5878) I'M 4474 GAF-793-02-02 12/08/2017
I'M App (TST1867) FM 4470 3048122 04/29/2013 PRI (TST5878) FM 4474 GAF-793-02-04 12/08/2017
I'M App (TST1867) FM 4470 797-08217-267 05/01/2013 UL,LLC(QUA9625) QA Inspect, R1306 (TX) 10/20/2016
FM App (TST1867) FM 4470 797-08264-267 05/23/2013 UL,LLC(QUA9625) CA Inspect, R1306 (IN) 10/27/2016
I'M App (TST1867) I'M 4470 3047237 07/15/2013 UL,LLC(QUA9625) CA Inspect, R1306 (MA) 10/18/2016
I'M App (TST1867) I'M 4470 3047636 08/08/2013 ULLLC(QUA9625) CA Inspect, R1306 (UT) 12/01/2016
This Evaluation Report covers EverGuard' TPO Single -Ply Roof Membrane Systems installed in accordance with GAF
published installation instructions and the Limitations / Conditions of Use herein.
4.1 EverGuard TPO membranes are nominal 45-mil (1.1 mm), 60-mil (1.52-mm) or 80-mil (2.0 mm) thick, internally
reinforced thermoplastic polyolefin roof covers supplied. Side and end laps are sealed using hot air welding. The
roof cover is mechanically attached or fully -adhered to Approved substrates.
w.�Ev7er,G�u;Fr,d:—.rxt--rint6i Cmp'biffi-� im�raaesi_aCWo min a I 50-mil (1.27-mm), 60-mil (1.52-mm), 70-mil (1.8) or 80-mil (2.0
mm) thick, internally reinforced thermoplastic polyolefin roof covers supplied. Side and end laps are sealed using hot
air welding. The roof cover is mechanically attached or fully -adhered to Approved substrates.
4.3 EverGuard' TPO FB Ultra membranes are nominal 45-mil (1.1 mm), 60-mil (1.52-mm) or 80-mil (2.0 mm) thick,
internally reinforced thermoplastic (TPO) roof covers with a polyester fleece backing. Side and end laps are sealed
using hot air welding. The roof cover is mechanically attached or fully -adhered to Approved substrates.
4.4 EverGuard Extremeo TPO FB Ultra membranes are nominal 50-mil (1.27-mm), 60-mil (1.52-mm), 70-mil (1.8) or 80-
mil (2.0 mm) thick, internally reinforced thermoplastic (TPO) roof covers with a polyester fleece backing. Side and
end laps are sealed using hot air welding. The roof cover is mechanically attached or fully -adhered to Approved
substrates.
4.5 EverGuard Freed OMTm TPO HW and EverGuardO Freedomy" TPO with RapidSeamy'4 Technology membranes are
nominal 45-mil (1.1 mm) or 60-mil (1.52-mm) thick, internally reinforced thermoplastic (TPO) roof covers with a self -
adhering backing. EverGuard" FreeclorrIT" TPO HW laps are sealed using hot air welding. EverGuarclO Freedo MW TPO
with RapidSea MT' Technology laps are self -adhering. The roof cover is self -adhered to Approved substrates.
NEMO ETC, LLC Evaluation Report 01506.09.05-1129
Certificate ofAuthorization #32455 6TH EDITION (2017) IFEIC NON-HVHZ EVALUATION FL5293-R28
GAF EverGuardO TPO Single -Ply Roof Membrane Systems Revision 29: 01/30/2018
Page 4 of 6
ONEMO I etc.
5.1 This is a building code evaluation. Neither NEW I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in HVHZ jurisdictions.
5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product.
5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with
FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.
5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members
shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load
resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511.
5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the
selected assembly shall meet or exceed the Zone I design pressure determined in accordance with FBC Chapter 16.
Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated
pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing
Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*
carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone
2/3 enhancements.
5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly
shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is
permitted for these systems.
5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing
deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing
Application Standard TAS 105.
5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any
surface conditions exist that bring system performance into question, field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-S2 or Testing Application Standard TAS 124 shall be
conducted on mock-ups of the proposed new roof assembly.
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall
be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having
Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data
Sheet 1-52 or Testing Application Standard TAS 124.
5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC
Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111,
except the basic wind speed shall be determined from FBC Figure 1609.3(l), 1609.3(2) or 1609.3(3).
5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 614320-3.
NEMO ETC, LLC Evaluation Report 01506.09.05-1129
Certificate ofAuthorization #32455 EDITION (2017) FBC NON-HVHZ EVALUATION FL5293-R28
GAF EverGuardO TPb Single -Ply Roof Membrane Systems Revision 29: 01130/2018
Page 5 of 6
ONEMOletc.
6.1 EverGuard" TPO Single -Ply Roof Membrane Systems shall be installed in accordance with GAF published installation
instructions, subject to the Limitations / Conditions of Use noted herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design
Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate
passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC
1609 for determination of design wind loads.
6.3 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running
perpendicular to steel deck flutes.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8.% MANUFACTURING PLANTS:
Contact named QA entity for details on manufacturing facilities covered for QA under F.A.C. Rule 61G20-3
requirements.
UL, LLC — QUA9625; (847) 664-3281; k.chancellor@ul.com
- THE 97-PAGES THA T FOLLOW FORM PART OF THIS EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 01506.09.05-R29
Certificate ofAuthorization #32455 EDITION (2017) FBC NON-HVHZ EVALUATION FL5293-R28
GAF EverGuardO TPO Single -Ply Roof Membrane Systems Revision 29: 01/30/2018
Page 6 of 6
1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 6
1B
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
6-8
1C
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
§-10
1D
Wood
New, Reroof (Tear -Off) or Recover
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
10
1E
Wood
New, Reroof (Tear -Off) or Recover
C-1
Mechanically Attached Insulation, Bonded Roof Cover
11-12
1F
Wood
New, Reroof (Tear -Off) or Recover
C-2
Plate -Bonded Roof Cover
13
113
Wood
New, Reroof (Tear -Off) or Recover
D-1
Insulated, Mechanically Attached Roof Cover
14
1H
Wood
New, Reroof (Tear -Off) or Recover
D-2
Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover
14
2A Steel New or Reroof (Tear -Off) A-1 Bonded Insula6ion, �Bon ed—R—oof-Co—ver 18
2B Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
18-24
2C Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Base and Cap Ply
25
2D Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B-2
Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover
26-27
2E Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C-1
Mechanically Attached Insulation, Bonded Roof Cover
28-39
2F
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C-1
Mechanically Attached Insulation, Bonded Base and Cap Ply
40
2G
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C-1A
Thermal Barrier with Vapor Barrier, Mechanically Attached Insulation, Bonded Roof Cover
41-45
2H
Steel or Structural concrete
New, Reroof (Tear -off) or Recover
C-2
Mechanically Attached Insulation, Plate -Bonded Roof Cover
46-48
21
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D-1
Insulated, Mechanically Attached Roof Cover
49-50
2.1
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D-2
Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover
50
3A
Structural concrete
New or Reroof (Tea r-Off)
A-1
Bonded Insulation, Bonded Roof Cover
51-61
3B
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Base and Cap Ply
61
3B
Structural concrete
New or Reroof (Tea r-Off)
F
Non -Insulated, Bonded Roof Cover
61
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded insulation, Bonded Roof Cover
62-63
4B
LWIC
New or Reroof [Tear -Off)
A-2
Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
64
4C
LWIC
New or Reroof (Tear Off)
E
Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover
65-66
4D
LWIC
New or Reroof (Tear Off)
F
Non -Insulated, Bonded Roof Cover
67-69
SA
CWF
New or Reroof [Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
70
5B
CWF
New, Reroof (Tear -Off) or Recover
C-1
Mechanically Attached Insulation, Bonded Roof Cover
71
5C
CWF
New, Reroof (Tear -off) or Recover
E-2
Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover
71
SA
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
72-73
6B
Gypsum
Reroof (Tear -Off)
A-2
Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
74
6C
Gypsum
Reroof (Tear -Off)
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
74-76
6D
Gypsum
Reroof (Tear -Off)
C-1
Mechanically Attached Insulation, Bonded Roof Cover
77
6E
Gypsum
Reroof (Tear -Off)
E-2
Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover
78
6F
Gypsum
Reroof (Tea r-Off)
F
Non -Insulated, Bonded Roof Cover
78
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
79-93
713
Wood or Steel
Recover
C-2
Plate -Bonded Roof Cover
94-95
X
Steel
Recover
D-1
Insulated, Mechanically Attached Roof Cover
96
7D
Various
Recover
F
Non -Insulated, Bonded Roof Cover
97
NEMO ETC, U.0 Evaluation Report 01506.09.05-1129 for F1.5293-1328
Certificate of Authorization #32455 6 th Edition (2017) FBC NON-HVHZ EVALUATION Revision 29: 01/30/2018
Prepared by: Robert Nieminen, PE-59166 GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 1 of 97
ONEMO I etc.
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted, fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
> Wood Deck: Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) or brill-Tec AccuTrac Flat Plate or
Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP 35. Min. 0.75-inch plywood penetration or minimum 1-inch wood plank embedment.
> Steel Deck: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) or Drill-Tec
AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only). Minimum 0.75-inch steel penetration, engage the top flute of the steel deck.
> Structural Concrete: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat Plate or Drill-Tec
AccuTrac Recessed Plate (insulation only) or Drill-Tec Heavy Duty ASAP 3S. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener
manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocya n u rate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral wool roof board that meets the CIA
requirements of F.A.C. Rule 6IG20-3 and is documented as meeting FBC 1505.1 and, forfoam plastic, FBC Chapter26, when installed with the roof cover.
Refer to GAF published installation instructions for details and requirements regarding the use of polystyrene insulation in EverGuardO roofing systems:
InsiulatIon: High Traffli AODIlcations.-, Recover ApplicatioLls:
> Expanded polystyrene (EPS) meeting or exceeding ASTM C578, Type > Extruded polystyrene (XPS) meeting or exceeding ASTM C578, Type > XPS Fan -Fold Recover Board with plastic facer meeting or exceeding
11, nominal 1.5 Ib/ft2 density and minimum 15 psi compressive IV, minimum 1-inch thick and minimum 25 psi compressive strength. ASTIVI C578, Type IV, 3/8-inch thick and minimum 25 psi compressive
strength. > Expanded polystyrene (EPS) with plastic facer meeting or exceeding strength.
> Expanded polystyrene (EPS) with plastic facer meeting or exceeding ASTM C578, Type IX, minimum 1-inch thick and minimum 25 psi > EPS Recover Board meeting or exceeding ASTM C578, Type IV, 1/2-
ASTM C578, Type 11, nominal 1.5 lb/ft2 density and minimum 15 psi compressive strength. inch thick and minimum 25 psi compressive strength.
compressive strength. > EPS Recover Board with plastic facer meeting or exceeding ASTM
C578, Type 11, 1/2-inch thick and minimum 15 psi compressive
strength.
TOPCOAT' FireOut" Fire Barrier Coating, VersaShieldO Fire -Resistant Roof Deck Protection or VersaShield' Solo- Fire -Resistant Slip Sheet, installed in accordance with GAF published installation instructions and fire
resistance certification listings, may be used as a non-loa d-bea ring, fire -barrier / slip -sheet component within any system outlined herein.
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete (LWIC) may be substituted for or installed below the rigid insulation board for System Type C-1 (mechanically attached Insulation, bonded roof
cover), System Type C-2 (plate -bonded roof cover) or System Type D (mechanically attached membrane), whereby the insulation or membrane fasteners are installed through the LWIC to engage the structural steel
or concrete deck. For Type C-1, the top insulation layer shall be that specified in the applicable Table. For Type C-2 or D if the LWIC is installed below, the rigid insulation board may consist of min. 0.5-inch
EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polylso Insulation, EnergyGuard NH Ultra Polylso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard HD Polyiso
Insulation, EnergyGuard NH HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation, EnergyGuard NH HD Plus Polyiso Insulation, EnergyGuard RH HD Polyiso Insulation orStructodek High Density Fiberboard
Roof Insulation or min. 0.25-inch SECUROCK Gypsum -Fiber Roof Board, SECUROCK Glass -Mat Roof Board or Dens Deck. The structural deck shall be of equal orgreater type, thickness and strength to the steel and
concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented
through proper codified and/or FBC Approval documentation. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-relatated issues, such as deckventing or moisture levels
within the LWIC and the potential effect on overlying components.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturet's published instructions.
> Hot Asphalt (HA): Full mopping, 25-30 lbs/square.
> GAF 2-Part Roofing Adhesive (GAF 2-Part): Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c.
> LRF Adhesive M (LRF-M): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
> OlyBond Adhesive Fastener (Classic): Full coverage, I gal/square.
> OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. using PaceCart, SpotShot or Canister delivery methods. Note: OlyBond Classic or OlyBond 500 Green may be used
in place of OlyBond.500 when used to bond insulation or coverboards.
> Note: When multiple layers(s) of insulation andlor coverboard are installed in ribbon -applied adhesive, boardjoints shall be staggered.
NEMO ETC, LLC Evaluation Report 01506.09.05-1129 for FL5293-RZ8
Certificate of Authorization #32455 6th Edition (2017) FBC NON-HVHZ EVALUATION Revision 29: 01/30/2018
Prepared by; Robert Nieminen, PE-59166 GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 2 of 97
*NEM01etc.
> Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table.
> Hot Asphalt (HA): MOP = -240.0 psf (Min. 0.5-inch thick)
> GAF 2-Part Roofing Adhesive (GAF 2-Part): MOP -117.5 psf (Min. 1.0-Inch thick)
> LRF Adhesive M (LRF-M): MDP = -232.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard NH Polylso Insulation, EnergyGuard Ultra Polyiso Insulation,
EnergyGuard NH Ultra Polyiso Insulation)
> OlyBond 500 (013500): MDP = -315.0 psf (Min. 0.5-inch thick EnergyGuard RH or RN)
> OlyBond 500 (OB500): MDP = -487.5 psf (Min. 0.5-inch thick EnergyGuard RA)
> OlyBond 500 (OB500): MDP = -292.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation,
EnergyGuard NH Ultra Polyiso Insulation)
8. Bonded polylsocya nu rate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone I design pressure determined in accordance with FBC
Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria, Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention
Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For System Type D, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes.
14. For Recover Applications using System Type C-2 or any System Type D, the insulation is optional. Alternatively, a separator board maybe installed prior to roof cover installation when using System Type C-2 or any
System Type D or a separator sheet may be installed prior to roof cover installation when using any System Type D. The existing roof system shall be suitable for a recover application. The separator component shall
be documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications.
> Separator Board Options for Recover System Type C-2 or System Type D: Min. 0.5-inch EnergyGuard Polylso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra
Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation, Structodeck High Density Fiberboard Roof Insulation, EnergyGuard RH HD Polylso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard NH HD
Polyiso Insulation, EnergyGuard HD Plus Polylso Insulation or EnergyGuard NH HD Plus Polyiso Insulation or min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board orSECUROCK Glass -
Mat Roof Board.
> Separator Sheet Options for Recover System Type D: EverGuard Polymat Separation Layer (3 oz/yd 2) or EverGuard Polymat Cushioning Layer (6 oz/yd 2).
15. Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC
Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-
coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
NEMO ETC, LLC
Certificate of Authorization #32455
Prepared by: Robert Nieminen, PE-59166
6th Edition (2017) FBC NON-HVHZ EVALUATION
GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411
Evaluation Report 01506.09.05-1129 for FL5293-R28
Revision 29:01/30/2018
Appendix 1, Page 3 of 97
N.NEMOjetc.
TABLE 11: WOOD DECKS - NE I W CONSTRUCTION , REROOF (TEA'R-OFF) OR RECOVER
SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOT COVER
System Deck Base Sheet Roof Co7er (Note 16) MDP
No.
(Note'l) Base 0a . steners Attach
Base Cap (PSO
SELF -ADHERING ROOF COVER:
Min. 19/32-inch
GAF StormSafe Anchor Sheet (Max.
32 ga-1-5/8-inch diameter.ti h
.§:!Kcli'&:-E-at.-min-4-inch�lap--.-�--�
EverGuard-_
9-ii
-*01 &� -at-,thaX:!----,40:inctf-,w-ide-or-'i-ap-p-e�a-io-p�r'o'
:1�1j�.-__�nnular- 4ha'n-k'naild�'ica?
'ring -(664 or
and 9-IncK -oc. attwo,-equa ly-
-450
2
-�7riiai-x-36-Fn-ct&wiae-�a�—Cc�-ia�s-
pacing)
reroof only; no recover)
spaced, staggered center rows
Min. 15/32-inch
GAF StormSafe Anchor Sheet (Max.
32 ga., 1-5/8-inch diameter tin caps with
6-inch o.c. at min. 4-inch lap
EverGuard
W-60.
plywood; 24"
48-inch wide)
12 ga. x 1.25-Inch annular ring shank
and 6-inch o.c. at two, equally
None
Freedom TPO
-45.0*
spans
nails (new or reroof only; no recover)
spaced, staggered center rows
W-61.
Min. 15/32-inch
plywood; 24"
GAF StormSafe Anchor Sheet (Max.
Drill-Tec #14 Fastener with Drill-Tec 3 in.
18-Inch o.c. at min. 4-inch lap
and 18-inch o.c. at two, equally
None
EverGuard
-45.0*
spans
48-inch wide)
Ribbed Galvalume Plate (Flat)
spaced, staggered center rows
Freedom TPO
W-62.
Min. 19/32-inch
plywood; 24"
GAF StormSafe Anchor Sheet (Max.
Drill-Tec #14 Fastener with Drill-Tec 3 in.
8-inch o.c. at min. 4-inch lap
and 8-inch o.c. at two, equally
None
EverGuard
-67.5* .
spans
48-Inch wide)
Ribbed Galvalume Plate (Flat)
spaced, staggered center rows
Freedom TPO
Min. 19/32-inch
GAF StormSafe Anchor Sheet (Max.
Drill-Tec,#12 or #14 Fastener with Drill-
8-inch o.c. at min. 4-inch lap
EverGuard
W-63.
,,, d
p ywoo at max.
40-inch wide or lapped to produce
Tec 3" Steel Plates or Drill-Tec 3 in.
and 8-Inch o.c. at three, equally
None
Freedom TPO
-105.0*
24"spans
max. 36-inch wide lap -to -lap spacing)
Ribbed Galvalume Plate (Flat)
spaced, staggered center rows
SYSTEM:
GAFGLAS #75 Base Sheet, Tri-Ply #75
(Optional) One or two plies Ruberoid 20
Min. 15/32-inch
Base Sheet, GAFGLAS #80 Ultima
32 ga., 1-5/8-inch dia. tin caps with 12
8-inch o.c. at min. 4-inch laps
Smooth, Ruberoid Mop Smooth, Ruberold Mop
EverGuard TPO FB
W-64.
plywood at max.
Base Sheet, GAFGLAS Stratavent
ga. annular ring shank nails (new or
and 8-inch o.c. in two, equally
Smooth 1.5 or Ruberoid Mop Plus Smooth in
Ultra in hot
-45.0
24-inch span
Nailable Venting Base Sheet,
reroof only; no recover)
spaced, staggered center rows
hot asphalt or Ruberold HW 25 Smooth or
apshalt
Ruberoid 20 Smooth
Ruberold HW Smooth, torch -applied
(Optional) One or two plies Ruberoid 20
Min. 19/32-Inch
GAFGLAS H80 Ultima Base Sheet,
32 ga., 1-5/8-inch dia. tin caps with 12
9-Inch o.c. at min. 4-inch laps
Smooth, Ruberoid Mop Smooth, Ruberold Mop
EverGuard TPO FB
W-65.
plywood at max.
GAFGLAS Stratavent Nallable Venting
ga. annular ring shank nails (new or
and 9-inch o.c. in two, equally
Smooth 1.5 or Ruberoid Mop Plus Smooth in
Ultra in hot
-45.0
24-Inch span
Base Sheet, Ruberoid 20 Smooth
reroof only; no recover)
spaced, staggered center rows
hot asphalt or Ruberoid HW 25 Smooth or
apshalt
I
Ruberoid HW Smooth, torch -applied
GAFGLAS #75 Base Sheet, Tri-Ply #75
(Optional) One or two plies Ruberold 20
Min. 15/32-Inch
Base Sheet, GAFGLAS #80 Ultima
32 ga., 1-5/8-inch dia. tin caps with 12
6-inch o.c. at min. 4-Inch laps
Smooth, Ruberoid Mop Smooth, Ruberoid Mop
EverGuard TPO FB
W-66.
plywood at max.
Base Sheet, GAFGLAS Stratavent
ga. annular ring shank nails (new or
and 6-inch o.c. in two, equally
Smooth 1.5 or Ruberold Mop Plus Smooth in
Ultra in hot
-52.5
24-inch span
Nailable Venting Base Sheet,
reroof only; no recover)
spaced, staggered center rows
hot asphalt or Ruberoid HW 25 Smooth or
apshalt
Ruberoid 20 Smooth
Ruberoid HW Smooth, torch -applied
GAFGLAS #75 Base Sheet, Tri-Ply #75
(Optional) One or two plies Ruberold 20
Min. 15/32-inch
Base Sheet, GAFGLAS #80 Ultima
16-inch o.c. at 4-inch laps and
Smooth, Ruberoid Mop Smooth, Ruberoid Mop
EverGuard TPO FB
W-67.
plywood at max.
Base Sheet, GAFGLAS Stratavent
Note 2 (#14 ONLY)
16-inch o.c. in two, equally
Smooth 1.5 or Ruberold Mop Plus Smooth in
Ultra In hot
-52.5
24-inch span
Nallable Venting Base Sheet,
spaced, staggered center rows
hot asphalt or Ruberold HW 25 Smooth or
apshalt
I Ru6eroid 20 Smooth
I Ruberoid HW Smooth, torch -applied
I
I
NEMO ETC, LLC Evaluation Report 01506.09.05-R29 for FL5293-1128
Certificate of Authorization #32455 6th Edition (2017) FBC NON-HVHZ EVALUATION Revision 29: 01/30/2018
Prepared by: Robert Nleminen,PE-59166 GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 15 of 97