HomeMy WebLinkAboutTRUSSSCANNiD
By
MiTek
Lumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs . rely on lumber values established by others.
RE: M1 1420 - MANOR MiTek USA, Inc.
6904 Parke East Blvd.
Site Information: Tampa, FL 33610-4115
Customer Info: WYNNE DEVELOPKAENT Project Name: M11420 Model:
Lot/Block: Subdivision:
Address: UNKNOWN
City: ST LUCIE COUNTY State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City: State:
General Truss Engineering Criteria Design Loads (individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 15 individual, dai.ed Truss Design Drawings and 0 Additional Drawings.
With my seal aff ixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G 15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal# I
Truss Name I
Date
1
T1 3944718
1 A
15/3/18
12
1 T1 3944719
1 Al ____[
5/3/18
13
1 T1 3944720
1 A2
15/3/18
4
T13944721
A3
1513/18 1
5
T1 3944722
A4
5/3/18
6
T1 3944723
A5
15/3/18
7
T1 3944724
1 A6
15/3/18 -J
18
1 T1 3944725
1 A7
15/3/18 _J
19
1 T1 3944726
1 BHA
15/3/18 1
110
1 T1 3944727
1 GR B
15/3/18 1
Ill
IT13944728IJ1
15/3/18 1
112
IT13944729IJ3
15/3/18
113
IT13944730IJ5
15/3/18
114
IT13944731IJ7
5/3/18
115
1 T1 3944732
1 KJ7
5/3/18
The truss drawing(s) referenced above have been prepared by MiTek
USA, Inc. under my direct supervision based on the parameters
provided by Chambers Truss.
Truss Design Engineer's Name: Albani, Thomas
My license renewal date for the state of Florida is February 28, 2019.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSl/TPl 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek's customers
file reference purpose only, and was not taken into account in the preparation of
these designs. MIT& has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per AN81/TPI 1, Chapter 2.
FILE COD
%% 4 4
0 o 39380
STATE OF Z
.00'.
,00
0 R N
0 N A %
1111011111111%
Thomas A. Marl PE No.39380
Mrrek USA, Inc. Fl. Cert 6634
6904 Parke East Blvd. Tampa FIL 33610
Date:
May 3,2018
Albani, Thomas I Of I -
Job
Tr ss
Truss Type
aty
Ply
MANOR
T13944718
r;l 1420
A
Common
1
1
Job Reference (optional)
Chambers Tiuss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu May 3 09:38:38 2D18
ID:-kfiGCA6bx7j2Syl HDXFw7ye3KX-Sx]BYjq3v8l 6gPdfQnLiOsyTf6dyFfaE3090Y
11-0-Q 6-4-8 7-4-Q 11-11-4 13-O-Q 17-6-0 23-0-12 1 28-7-8 35-0-0
6
4.00 [1-2
6X8 =
4-6-0
4X4 =
Scale = 1:59.3
6
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
In (too)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.33
Verl(LL)
-0.0712-23
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.35
Vert(CT)
-0.1712-23
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.39
Horz(CT)
0.02 10
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL)
0.10 12-23
>999
240
Weight: 167 Ito FT = 20%
LUMBER- BRACING-
TOPCHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 5-8-12 oc puffins.
BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at micipt 6-15
REACTIONS. Ail bearings 0-8-0.
(lb) - Max Horz 2=-1 79(LC 10)
MaxUplift All uplift 100 lb or less atjoint(s) 17 k , cept2=-186(LC12),15=-908(LC12),10=-469(LC12)
MaxGrav All reactions 250 lb or less atjolnt(s) except 2=265(LC 21), 17=351(LC 21),15=1555(LC 1),
10=733(LC 1) 1
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 3-5=-370[724, 5-6=-264/718, 6-7=-438/407, 7-9=-1286/872,9-10=-1478/967
BOTCHORD 12-14=-377/728, 10-12-817/1378
WEBS 5-15=-271/329, 6-15=-1213/791, 6-14=-417/720, 7-14=-612/535, 7-12=-358/626,
9-12=-340/347, 3-15=-530/448
NOTES-
1) Unbalanced roof live loads have been considered for this design
2) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vascl=1128mph;� TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=35ft; eave=5ft; Cat.
11; Exp, C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Intedor(l) 2-6-0 to 17-6-0, Extedor(2) 17-6-0 to
21-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17 except ot=lb)
2=186,15=908�10=469.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Clift 6634
0904 Parke East Blvd. Tampa FL 33610
Date:
May 3,2018
WARNING - Verify design parameters and READ MOTESON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/0312015 BEFOREUSE,
Design valid for use only with M17ekV conneclors. This design Is based only up.Dn parameters shoxvn. and Is for an Individual building componenL not
OF
a truss system. Before use. the building designer must veilfy the applicability 61 design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or ctK)rd members only. Addillonal lemporary and permanent bracing
Is
WON(
always required for stability and to prevent collapse Win possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery. erection and bracing of Misses and 'IRISS Systems. se(-ANSVTPI I Quality Criteria. DSB89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street. Sulle 312. Alexandria. VA 22,314.
Tampa, Fl. 33610
Job
Truss —
Truss Type
ally
MA OR
TI 3944719
M 11420
At
Common
12
�Ply
1
�
Job Reference (optio nal�
Chambers Truss, Inc., Fort Pierce, FL 0. 1 au b Ividl ; j ecu! o Ivil I vN wluij�Lrlws' H1r. U ay ; ; "k,
ID:-kfiGCA6bx7j2SyIHDXFw7ye3KX-w7sZl3rhgSgzlZCr_UPfP90knlB4OzuDFpm5bOzKFIE
8-4-0 �4 1 lj�0 760 2 1�1 - L6�8 0 35-0-0 10
4T 1 3. 8-4-0 _0 - 3?
8-4-0 0�1_ 0_�O_j
�11__0040 T7 4
d
6
3X6 =
4.00 F1 _2
4xS =
17 15 14 12
2x3 11 4X6
3X8
8-4-0 9-1-14 12-11-0 17-6-0 1 22-1-0
46 2x3 11
3XB =
Scale = 1:59.5
ich
6
3X6 =
LOADING (psi) SPACING- 2-0-0 CSI. DEFL. In (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.72 Vert(LL) -0.31 14-15 >999 360 MT20 2441190
TCDL 7.0 Lumber DOL 1-25 BC 0.76 Vert(CT) -0.65 14-15 >645 240
BC;LL 0.0 Rep Stress Incr NO WB 0.68 Horz(CT) 0.13 10 rVa n/a
BCDL 10.0 Code FBC2017frP[2014 Matdx-MS Wind(LL) 0.35 14-15 >999 240 Weight: 166 lb FT = 20%
LUMBER- BRACING-
TOPCHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-1-5 oc puffins.
BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 4-9-5 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1424/0-8-0, 10=1424/0-8-0
Max Horz 2=1 79(LC 11)
Max Uplift 2=-868(LC 12), 1 0=-868(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or leiss except when shown.
TOPCHORD 2-3=-Ml/2332,3-5=-2887/2019,5-6=-2886/2123, 6-7=-2886/2123, 7-9=-2887/2019,
9-1 0=-3481/2332
BOTCHORD 2-17=-2074/3261,15-17=-2074/3201, ll+-It)=-Ieoujz[18,12-14=-2089/3261,
10-12-2089/3261
WEBS 7-14=-253/310. 5-15=-253/310, 6-15=-6441985, 6-14=-644/985, 3-15=-677/504,
9-14=-677/504
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=35ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Ext6rior(2) -1-0-0 to 2-6-0, Interior(l) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL-_11.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=868,10=868.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 75 lb down and 70 lb up at
15-0-0, and 75 lb down and 70 lb up at 20-0-0 on top chord. The designiselection of such connection device(s) is the responsibility
of others.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plt)
Vert: 1-6=-54, 6-11 =-54, 18-21 =-20
Concentrated Loads (lb)
Vert: 26=-75(F) 27=-75(F)
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
May 3,2018
WARNING - Verily designparameters andREAV NOTES ON THIS ANO INMUDED MITEKREPERANCE PAGE U11-7473 rev. 1010312016 BEFORE USE.
Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown. and Is for an Individual building component. not
a Iniss system. Before use, the building designer mwit verity the applicability of design parameters and properly Incorporate IN, design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
-MiTek'
Isalways required for stability and to prevent collopre with possible personal Injury and properly damage. For general guidance regarding the
fabricallon, storage. delivery, erection and bracing of fnisses and truss systems. seeANSI/TPI I Quality Criteria, DSB89 and 8CSI Building Component
6904 Parke East Blvd.
Safety Information available frorn Truss Plate Institute. 218 N. Lee Street Suite 312, AJexandla, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
ly
MANOR
:
T13944720
M11420
A2
Roof Special
Job Reference (optional)
.; I TK,, hA—, '2 nQ-QA-An gni A pnnn i
(5h—ambers Truss, Inc., Fort Pierce, IL 8. , ou s Iviar 1 1 — 1 D 1- 1 ek Indus r es,
ID:-kfiGCA6bx7j2Syl HDXFw7ye3KX-OJoxzPsJQIHqvin2YCXL
11-0-4 11-11-15 17-6-0 - L7- ��6
A- r ri�11-111 5-6-1 14 6 -
�1 --n ! - 2 - I I I 1 32 018 1 -4
Scale = 1:60.4
4. 0 0 F1-2 45 =
oxQ
24 257
46 46 3x6 Z-
4 a 3x4 zz�
3x4 9
3
26
10 11
1 16 7x8 MT SHS
14
6 2x3 11 48 :z o
5X8 2x3 11 3x6
3X12 2. 0 0 FI-2
LOADING (pst) SPACING- 2-0-0 CS11. DEFL. in (loc) Well Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 11:�2 TC 0.55 Vert(LL) -0.57 15 >743 360 MT20 2441190
TCDL 7.0 Lumber DOL , ?: BC 0.95 Vert(CT) -1.05 15-16 >401 240 MT18HS 244/190
BCLL 0.0 Rep Stress Incr YES WB 0.87 Horz(CT) 0.41 10 n1a n/a
BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.78 15 >536 240 Weight: 166 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-8-10 oc puffins.
BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at micipt 5-14
REACTIONS. (lb/sIze) 2=1349/0-8-0, 10=1349/0-8-0
Max Horz 2=1 79(LC 11)
Max Uplift 2=-826(LC 12), 1 0=-825(l-C 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3=-576513660, 3-5=-5280/3401, 5-6=-2375/1'651, 6-7=-2355/1670, 7-9=-2572/1756,
9-10=-335612175 1
BOTCHORD 2-16=-3383/5481,15-16=-3391/54uL,, i4-ib=-zuuu/4930,13-14=-145412426,
12-13=-1952/3150,10-12=-1952/3150
WEBS 3-15=-517/342, 5-15=-1 066/1889, 5-14=-2958/1935. 6-14=-749/1199, 7-14=-370/282,
9-13=-825/574, 9-12=01299
NOTES -
I ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128moh; TCDL--4.2psf, BCDL=3.Opst; h=15ft; B--45ft; L--351t; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterlor(2) -1-0-0 to 2-6-0, Interlor(l) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21 -0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise Indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSIrFPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except flt=lb)
2=825,10=825.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cort 6634
6904 Parke East Blvd. Tampa Fl. 33610
Date:
May 3,2018
WARNING - Verify design parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010312016 BEFORE USE.
mt, no,
, only %,Ath MllekG connociors. this design Is based only upon parameters shown, and Is for an Individual building compone
Design valid for use
0 truss system. Before use, the building designer must verify the applicability of design parameters and properly fincoiPM40- IM design Into the o% 11-1.11
bullding design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
-MITek'
Is always required for stability and fo prevent collapse vAth possible persbnal Injury and properly damage. for General guidance regarding the
fabricallon, slorage, delivery. erection and bracing of trusses and truss systerns, seeAr4SI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information avallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Jop
Truss
Truss Type
aty
Ply
MANOR
T13944721
MI 1420
A3
Hip
Job Reference (optional)
4 n4a&A;7 u 1 '1 tvi_ jn� Thu, hA.,, A no-W-Al gni A PACIP i
Chambers Truss, [tic., Fort Pierce, FL D. s a. I . . . . .—I - — - � --
ID:-kfiGCA6bx7j2Syl HDXFw7ye3KX-sW-JAItKB3PhXsLE6vS7Ua571qqOsrJVi6FCfL)zKFIC
-0-0 21-4-8 2Z 9 35-0-0 6-0
1-0 �4 L11-7-�5 17-0-0 IS �6 2-10 11 -0-
-0 -1 L
HO-- 6XI-.144 4--8-- 0_7-11 5-4-1 4-0-0 3-4-8 4 7-
3x12 -.= 2.00 F1 —2
6-0-0
3x4 zz 5X8 2x3 11 3x6
35-0-0
Scale = 1:62.6
17
2
I?
0
LOADING (psi) SPACING- 2-0-0 CS1. DEFL. in (foe) I/defl Ud PLATES GRIP
TCUL 20.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) -0.56 17 >745 360 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -1.06 16-17 >396 240 MT18HS 244/190
BC;LL 0.0 Rep Stress Incr YES W13 0.81 Horz(CT) 0.41 11 rVa n1a
BCDL 10.0 Code FBC2017/TP12014 Matdx-MS Wind(LL) 0.78 17 >538 240 Weight: 173 lb FT = 20%
LUMBER- BRACING-
TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-8-11 oc purlins.
BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Row at midpt 5-16
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 11=1349/0-8-0
Max Horz 2=-1 75(LC 10)
Max Uplift 2=-825(LG 12), 11 =-825(LC 12)
FORCES. (lb) - Max, Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3=-5767/3603, 3-5=-5289/3602, 5-6=-2421/1761, 6-7=-226211731, 7-8=-2401/1785,
8-1 0=-2569/1849, 10-11 =-3358/2259
BOTCHORD 2-18=-3538/5482,17-1 8=-3549/5498,16-17=-.3194/4939,15-16=-I 324/2238,
14-15=-1546/2427,13-14=-2045/3152,11-13--'-2045/3152
WEBS 3-17=-5081336, 5-17=-1 141/1908, 5-16=-2938/2044, 6-16=-365/618, 7-15=-499/604,
8-15=-335/287, 10-14�827/576, 10-1 3=0/300
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B--45ft; L=35ft; eave=5ft; Cat.
11; Expi C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exierior(2) -1-0-0 to 2-6-0, Interior(l) 2-6-0 to 17-0-0, Exterior(2) 17-0-0 to
18-0-0, Interfor(l) 22-11-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise Indicated.
5) This truss has been designed for a 10.0 psi bottom chord live'load nonconcurrent With any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI I angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=825, 11 =825.
Thomas A. Alban! PE No.39380
MITok USA, Ine. FL Cott 6634
8904 Parke East Blvd. Tampa f L $3610
Date:
May 3,2018
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEKREFERANCE PAGE M11-7473 rev. 1010312016 BEFORE USE.
Design valid for use only with MilekO conneclors. This design Is based only upon parameters shown, and Is for an Individual building cornponeni, not
a truss system. Before use. the bullcring designer i nust verify the applicability of design parrainoleFs and properly Incorporate this, design Into the overall
building design, Brachg Indicated Is to prevent buckling of Individual trussweb and/or chord members only. Additional temporary and permanent bracing
'MiTek'
Is always requited for stability and to prevent collapse Wth possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systerns. seeANSIIIPI I Quality Criteria, DSB-89 and SCSI 8ulicang Component
6904 Parke East Blvd.
Tampa, FIL 33610
Safety Information available from Truss Plate Institute. 218 N. Lee Stireet-quile 312. Alexandria. VA22314.
Job
ss
Type
Oty
Ply
MANOR
T13944722
M 11420
A4
Hip
1
o e erence a ional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MITek Industries, Inc. Thu May 3 09:38:42 2018 Page 1
ID:--kfiGGA6bx7j2Syl HDXFw7ye3KX-KiYiN5tZyNXYgOwQfdzMOoeGIEBebJifxm-nIBKzKFIB
7-11-14 ItO g4 0 00-0 ILI.�4 A4 35-0-0 �6-0-Q
1-1 7-11-14 3_ L5-;--0 1 _jI 2 M
1--A00 Al 10� 2 IN- 7-2-10
6
4.00 f-12
4x5 4X8 = 2x3 11
7 8
2x3 It 13 12 3X6
3x12';::: 2.00FI-2 5X8 2X3 11
1
7-11-14 , 11-0-4 1 , 1"-0
LOADING (ps'
SPACING-
2-0-0
CS1.
DEFL.
in
(IoG)
Well
Ud
TCUL 20.0
Plate Grip DOL
1.25
TC 0.67
Vert(LL)
-0.51
16
>818
360
TGDL 7.0
Lumber DOL
1.25
BC 0.89
Vert(CT)
-0.95
16
>442
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.74
Horz(CT)
0.37
10
rda
n1a
BCDL 10.0
Code FBC2017[rPI2014
Matrix -MS
Wind(LL)
0.70
16
>597
240
LIUMBER-
TOP CHORD 2X4 SP M 30
BOT CHORD 2X4 SP M 30
WEBS 2x4 SP No 3
BRACING-
TOPCHORD
BOTCHORD
WEBS
REACTIONS. Qb/size) 2=1349/0-8-0, 10=1349/0-8-0
Max Horz 2=-1 55(LC 10)
Max Uplift 2=-825(LC 12), 1 0=-826(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) oi� less except when shown.
TOPCHORD 2-4=-5727/4026,4-5=-5210/3802, 5-6=-2939./2239, 6-7�2792/2190,7-8=-2470/1993,
8-9�2542/1930, 9-10=-3354/2403
BOTCHORD 2-17=-3740/5444,16-17=-3747/5447,15-161-3340/4846,14-15=-1 599/2391,
7
13-14=-1624/2401, 12-13=-2182/3130,10-12.=-2182/3147
WEBS 4-16=-539/357, 6-15=-424/680, 7-15�422/697, 9-13=-861/647, 9-12=0/306,
5-16=-1279/1924, 5-15=-2430/1787
Scale = 1:62.6
PLATES
GRIP
MT20
244/190
MT1 8HS
244/190
Weight: 166 lb
FT = 20%
Structural wood sheathing directly applied or 2-5-7 OC PLIdins.
Rigid ceiling directly applied or 3-8-4 oc bracing.
1 Row at midpt 5-15
NOTES- I
1) Unbalanced roof live loads have been considered for this de ' sign.
2) Wind: ASCE 7-10; Vult=l 65mph (3-second gust) Vasd=1 28mph; TCDL--4.2psf; BCDL=3.Opsf; h=1 511; B=45ft; L--35ft; eave=5ft; Cat.
11; Exp Q Encl., GCpi=O. 18; MW FRS (directional) and C-C Extedor(2) -1 -0-0 to 2-6-0, Interior(l) 2-6-0 to 15-0-0, Exteflor(2) 15-0-0 to
20-0-0, Interior(l) 24-11-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water poncing.
4) All plates are MT20 plates unless otherwise Indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members.
7) Bearing at Joint(s) 2 considers parallel to grain value using ANSIITPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=825,10=825.
Thomas A. Alban! PE No.39380
MITek USA, Inc. FL Cott 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
May 3,2018
,& WARNING. Verily de.Ign pamm.t..nd REAID NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015SEFOREUSE
Design valid for use only with Mflek0conneclors. TUs design Is based only upon pxiramelers shown. and Is for an Individual buildingcomponenfnol
atrusssystem. Beforeuse, the bullding designer must verify the applicability of design parameters and property incorporate 1111sclesignInto fheoverall
bullding design. Bracing Indicated Is to prevent bucklIng of IndIvidual.ituss web and/or chord members only. Addiflonal temporary and permanent bracing
Mffek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricarflon. storage, delivery, erection and biacing of trusses and truss systems, seeANSVTPI I Quality Criteria. DSS-89 end SCSI Building Component
6904 Parke Easl Blvd.
Safety Information avollable from Truss Plate Institute. 218 K Lee Sireel, Suite 3*12. Alexandria. VA 22314.
Tampa, Fl. 33610
Job
Truss
Truss Type
Qty
Ply
MANOR
T13944723
M1 1420
A5
Hip
Job Reference o tional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu May 3 09:38:43 2018 Page I
ID:-kfiGCA6bx7j2Syl HDXFw7ye3KX-ou64bRuBjgfPnAVdDKUbZ?ASJeWbKtieoAQkJknzKFiA
�4 0-0 760 200 27-9�6 35-0-0 -0-
0
4 V00 6� li-11 4-- i'21-1-12 Y 5-9- 7-2-10 WOO?
6
4.00 F1_2
46 —_ 4x5 = 3x4 = 4xG
4 5 24 625 26 27 7
3xl 2 2.00 f 1-2 5x12
6-0-0
2x3 11
Scale = 1:61.6
t2
0
LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/dell Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) -0.52 14-15 >813 360 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.91 Vert(CT) -0.96 14-15 >438 240 MT18HS 244/190
BCLL 0.0 Rep Stress Incr YES WB 0.70 Horz(CT) 0.37 9 n/a n/a
BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.71 14-15 >588 240 Weight: 163 lb FT = 20%
LIUMBER-
BRACING-
TOPCHORD 2x4 SIP M 30 TOPCHORD Structural wood sheathing directly applied or 2-8-5 oc purlins.
BOTCHORD 2x4 SID M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SIP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-6-0
Max Horz 2=-1 36(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3=-5766/4136, 3-4=-5219/3848, 4-5=-3738/2794, 5-6�3580/2701, 6-7=-2472/1983,
7-8=-2580/1976, 8-9=-335012455 1
BOTCHORD 2-15=-3854/5481,14-15=-386415491, 13-14=-3392/4858,12-13=-2113/3091,
11 -12=-223313144, 9-1 1=-2233/3144
WEBS 5-13=-727/1023, 6-13=-373f694, 6-12=-889[704, 7-12=-345/556, 8-12=-810/649,
8-11 =0/284, 4-14=-1 284/1813, 4-113-19811/1559, 3-14=-538/374
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4.2psf; BCDL=3.Opsf; h=15ft; 8--45ft; L=351t; eave=5ft; Cat.
11; Exp C; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterfor(2) -1-0-0 to 2-6-0, Interior(l) 2-6-0 to 13-0-0, Extedor(2) 13-110 to
26-11-6, Intedor(l) 26-11-6 to 36-0-0 zone;C-C for members and forces & MWIFRS for reactions shown; Lumber DOL=11.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 Wide
will fit between the bottom chord and any other members. ,
7) Bearing at joint(s) 2 considers parallel to grain value using ANSIfTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ut=lb)
2=825,9=825.
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cort 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
May 3,2018
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10=2015 BEFORE USE.
Design vaild for use only with IAfTeM connectors. This design is based only upon parameters shown, and IS for on Individual building component, not
a truss system. Before use, the buIlding designer must verity the applicability of design pararneleis and properly Incorporate this design Into the overall
building design. Bracing [ridiculed Is to prevent Nick1frig of Individual truss web and/or chord members only. Additional temporary and permanent bracing
NOW
is always teclulred for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding The
fabilcallion. storage. delivery. erection and bracing of trusses and truss systems. soeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2 18 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
M 11420 JA6 I Hip
MANOR
T13944724
C'.
6
Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu May 3 09:38:44 2018
ID:-kf!GCA6bx7j2SyIHDXFw7ye3KX-G4fSonvqU-nGOK4pn2?q6Djd72rp3DWyP4TsC
-0-0 ��6-0--(
11-0-0 16-2-4 21-4-8 24-0-0 29-1-2 35
5xB MT1, BHS �
2x3 11 3X5 5x6
zX3 I 1 08 z� ij le
Sx8 MT1 8HS 2x3 11 3x6
4x10 2.00FI-2
5-1
Scale = 11:61.5
cr)
0
3c?
o
LOADING (pst) SPACING- 2-0-0 CS1. DEFL in (loc) I/dell Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(I-L) -0.62 15 >682 360 MT20 244/190
TC;DL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -1.1414-15 >368 240 MT18HS 2441190
BCLL 0.0 Rep Stress Incr YES WB 0.72 Horz(CT) 0.40 9 n/a rLta
BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.86 15 >491 240 Weight: 162 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-7-2 oc pudins.
BOTCHORD 2X4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/sIze) 2=1349/0-8-0,9=134910-8-0
Max Horz 2=1 17(LO 11)
Max Uplift 2=-825(LC 12),9-825(LC 12)
FORCES. (lb) - Max- Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3�578314248, 3-4=-524513841, 4-5-4059/3075, 5-6=-4059/3075, 6-7=-2792/2215,
7-8=-2957/2251, 8-9=-3381/2531
BOTCHORD 2-16=-3967/5498,15-16=-398215514,14-15=-3489/5042,13-14=-1954/2821,
12-13=-1 940/2792,11-12=-2319/3179, 9-1 1=-2319/3179
WEBS 3-15=-535/494, 4-14=-1 038/741, 5-14-411/420, 6-14=-1 056/1510, 6-1 3=-637/537,
7-12=-318/512, 8-12=-484/418, 4-15=-1 254/1884
NOTES- i
1) Unbalanced roof live loads have been considered for thisidesign.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4.2psf; BCDL=3.0psf: h=1 5ft; B--45ft; L=35ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exteflor(2) -1 -0-0 to 2-6-0, Interlor(l) 2-6-0 to 11-0-0, Extedor(2) 11-0-0 to
29-1-2, Intetior(l) 29-1-2 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSI1TP( 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=825,9=825.
Thomas A. Albani PE No.39380
MlTek USA, Inc. Fl. Cert $634
6904 Parke East Blvd. Tampa FL 33610
Date;
May 3,2018
WARNING - Vejjj� design pararriters and READ NOTES ON THIS AND INCLUDED MffEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MITekV connectors. This design Is based only upon parameters shown, and Is for an Individual building component. riot
a truss System. Before use, Pre building designer Must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent budding of Individual truss web and/or chord members orily. Addillonal temporary and permanent bracing
NT
ek'
Is always required for stability and to prevent collapse with possible personal Injuty and property damage. For general guidance regarding the
labricallon. storage, delivery, ereeflon and bracing of trusses and truss sysl( wris, se-PANST/TPI 1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
safety Information available from Truss Plate Instliule. 218 N. Lee Street. Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
oty
Ply
T13944725
M11420
A7
Hip
Job Reference
Chambers Truss, Inc., ort Pierce, FL 8.130 s Mar 11 2016 Kill I UK HWUSLries, Inc. 1 ju jyjay o o-ou.— 20 18 age I
ID:-kfiGCA6bx7j2SyIHDXFw7ye3KX-IHDqO6wSFlv7OUf?LIW3eQGmNRAoodP5dkDQofzKF18
L6 1-1 1 ' ' L5 O�O V6 0-?
21-4-8 i g(y
1-0 -1 9-2-0 1-H I -� —0 --2 5-2-2
�1 —0 -_3 44-111-14 1 4-0--� 1 12—.—
c�.
c;.
6
Sxl 2 MT1 BHS =' 6x8 =
4. 0 0 fl-2 Fx3 11 54 WB= 44
4 5 27 6 7 828
4x8 =
2X3 11 7X10 MT18HS 44 :z 14 115
3x12 5- 2.00Fiff 5XB 3A 4x5
11-0-4! . 16-2-6 21-4-8
Scale = 1:61.4
2
LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) -0.77 15-16 >542 360 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.99 Vert(CT) -1.44 15-16 >291 240 MT18HS 244/190
BCLL 0.0 Rep Stress Incr YES WB 0.93 Horz(CT) 0.48 11 n1a n/a
BCDL 10.6 Code FBC2017ITP12014 Matrix -MS Wind(U-) 1.0715-16 >392 240 Weight: 158 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc puffins.
BOT CHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 11=1349/0-8-0
Max Harz 2=-97(LC 10)
Max Uplift 2=-825(LC 12), 11 =-825(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3=-5659/4099, 3-4=-561214174, 4-5-731515343, 5-6=-731515343, 6-8=-5252t38841
8-9=-3582/2744, 9-1 0=-3067/2304, 10-11 �3401/2620
BOTCHORD 2-18=-3820/5373, 17-1 8=-3849/5401, 16-17=-3833/5392, 15-16=-3702/5327,
14-15=-2509/3593, 13-14=-2003/2890, 11-13=-2402/3206
WEBS 6-16=-1 506/2128, 6-15=-853f7O5, 8-15=-1 276/1854, 8-14�975/807, 9-14=-687/920,
9-13=-1 501380,10-13=-370/449, 4-16=-1 721/2449
1
NOTES-
1) Unbalanced roof live loads have been considered for this, design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4-2psf; BCDL--3.opsf-, h=15ft; B=45ft, L=35111; eave=5ft; Cat.
11; Exp C; Encl., GCpi=O. 18; MW FRS (directional) and C-C Exterior(2) -1 -0-0 to 2-6-0, Interlor(l) 2-6-0 to "-0, Extedor(2) 9-0-0 to
30-11-6, Interlor(l) 30-11-6 to 36-0-0 zone;C-C for members and forces & MWFRS fo.r reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise Indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
wil(ift between the bottom chord and any other members..
7) Bearing at Joint(s) 2 considers parallel to grain value using ANSI[TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at JoInt(s) except Ct=lb)
2=825,11=825.
Thomas A. Albani PE No.39380
MITO USA, Inc. FIL Cort 6634
6904 Parke East Blvd. Tampa I'L 33610
Date:
May 3,2018
lll� -
A6� WARMING - Verify dwign paramelersand READ MOTES OM THIS AMD INCLUDED WTEKREFERAMCE PAGEM11-7473 rev. 1010312015 BEFORE USE.
--
W1,
Design valld for use only IoAlh MITeW conneclors. Ihs design is based only upDn pararnetels shown. and Is for an Individual building component, not
0 truss system. Before use. the building designer must verify the applicability of design paramelers and properly Incorporate IhIs clesign Info the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional lernporary and permanent bracing
WiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property clarriage. For general guidance regarding the
fabrication, storage. clefIvery, erection and bracing Of tFUSSeS and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Ins1ifute. 218 N. Lee street, Suite 312. Mexandria. VA 22314.
Tampa, FL 33610
Job
ss
Type
Oty
Ply
MANOR
T139447261
M11420
BHA
er
1
1
Job Referenge oRti2ngl)
L
Chambers Truss, Inc.,
Fort Pierce, FIL
8A 30 s [Oar i i 2018 Mi Tek indusirws, ill(;. I llu IVIEly 3 09:38:41 40 10 ragc 1
ID:-kfiGCABbx7j2Syl HDXFw7ye3KX-hfLbRoxinvgqFnpOSAZXjrL5jFz7GbjO52iWtYzKFI6
13-0-03-6.0
23-6-0 25-10-2
Z-2
11k0 Ll.fic 11-0,11 13,1,15 15-6-0
17-6 -0 00 0,3 1 0110 6
" :
0 Wo 9_0 Is"' %
A
1 .g2
1 _ _
0-6-b 0-s-Is 2-0-0
2 �O of,lt 2 M
2-0- -XI-1 -().-
Scale = 1:62.6
TOP CHORD MUST BE BRACED BY END JACKS,
44 ROOF DIAPHRAGM, OR PROPERLY CONNECTED
4.00 FI-2
PURLINS AS SPECIFIED.
6
3x4 =NAILED 3xG � NAILED NAILED NAILED 4xS = NAILED NAILED 3X8 = 3x6
3x4 NAILED 6x8 NAILED 3X6 Special
NAILED
LOADING (pso SPACING- 2-0-0 CSI_ DEFL. In (loc) I/dell Ud PLATES GRIP
TCLIL 20.0 Plate Grip DOL 1.25 TC Vert(LL) -0.1328-30 >999 360 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 C Vert(CT) -0.2828-30 >951 240
BCLIL 0.0 Rep Stress Incr NO Horz(CT) 0.04 26 n1a n1a
BCDL 10.0 Code FBC2017ITP12014 WInd(LL) 0.1928-30 >999 240 Weight: 216 lb FT = 20%
LUMBER- BRACING-
TOPCHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-11-6 OC pUrlins.
BOTCHORD 2X4 SP M 30 Except:
WEBS 2x4 SP No.3 2 Rows at 1/3 pis 12-24
BOTCHORD Rigid ceiling directly applied or 5-8-12 oc, bracing.
WEBS 1 Row at midpt 14-32
JOINTS 1 Brace at Jt(s): 8, 16,18, 20, 23,12
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=-1 79(LC 6)
MaxUp1lft All uplift 100 lb or less atJoInt(s I ) except 2�254([_C 25), 32=-1 008(LC 8), 26-770(LC 8).
34=-350(LC 8)
MaxGrav All reactions 250 lb or less at joint(s) except 2=256(LC 13), 32=1990(LC 1), 26=1259(LC 1).
34--569(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 3-4=43911190,4-6=4091211, 6-9=-405/246, 9-1 1=-426/307,11-13=-403/328,
24-25=-309511766, 25-26=-3188/1833, 3-5-151/602, 5-7=- 151/602, 7-8=-1 511602,
B-1 0=-738/1719, 10-12=-738il 719, 12-14=-738/1719, 14-15=-1 839/1122,
15-17=-1 839/1122, 17-19=-1 839/1122, 19-21 =-2539/1572, 21-22�2539/1572,
22-24=-2539/1572, 2-3=-204/444,13-16=-400/327,16-18=-423/306.18-20=-400/245,
20-23=-4051209, 23-24�437/11 88
BOTCHORD 2-34=-355/254, 32-34�1 345/766, 31-32=-1 70/611, 30-31 =-1 70/611, 28-30=1 094/2213,
26-28=-1650/3001
WEBS 8-34=-633/1205, B-32=-741/526,14-32=-2211/1058,14-31=-11/352,14-30=-1045/1811,
19-30=-560/476,19-28=-486/816, 24-28=-78/443, 3-34=-740/570
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; SCDL=3.Opsf; h=15ft; B-_45ft; L=351t; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 '
3) Truss designed for wind loads In the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 2x3 MT20 unless otherwise indicated.
6) Gable studs spaced at 2-0-0 Do.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.Opst on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 254 lb uplift at joint 2, 1008 lb uplift at
joint 32, 770 lb uplift at joint 26 and 350 lb uplift at joint 34.
10) Graphical puffin representation does not depict the size or the orientation of the puffin along the top and/or bottom chord.
6
Thomas A. Albani PE No.39380
MITok USA, Inc. FL Cori 6834
69D4 Parks East Blvd. Tampa FL 33610
Date:
May 3,2018
Wdibmtes 3-10d (0.146"xX) or 3-12d (0.148'x3.25" toe- ails Der NDS QuIdlines.
,&WARNING -Veriffydesignparametemnd READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 10103,2015 BEFORE USE
Design vdid for use ardyvAth !Arleko) conneclors. Bils design is based only upon parameters shown. and Is for an Individual building cornpK)nent, not
Q [kiss systern. Before use. ihe bdIdIng designer must verify the applicability of design parameters and properly incorporate this design Into the overall
design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporally and permanent bracing
MiTek'
bt!lidlng prevent
Is always requited for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication. storage, delivery, erection and bracing of trusses and UU&S Systems, seeANSI/TPII Quality Criteria, DSE-89 and BCSI Building Component
Tampa, FIL 336 10
Safety Information avallable from Truss Plate Institute, 218 N. Lee street, Sulte, 312. Alexandria. VA 22314.
1
job
Truss
Truss Type
QtY
Ply
MANOR
T13944726
M11420
BHA
Common Gilder
1
1
Job Reference o IionqI)
J-p-
4 4 nn40 hAM�L, 1 1 Thii hll� q no-qR-A7 gni R pqnp. 9
Chambers I russ, Inc., t-011 Melce, t-L
ID:-kfiGCA6bx7j2Syl HDXFw7ye3KX-hfLbRoxinvgqFnpOSAZXjrL5jFz7rbjO52iWtYZKFI6
NOTES-
12) Hanger(s) or other connection device(s) shall be provided Sufficient to support concentrated load(s) 258 lb down and 331 lb up at 7-0-0, and 258 lb down and 331 lb up at
27-11-4 on top chord, and 386 lb down and 247 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) Is the responsibility of others.
13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit) I
Vert: 3-13=-54, 24-27=-54, 35-38=-20,1-3=-54, 13-24=-54
Concentrated Loads (lb)
Vert: 30=-63(F) 28=-386(F) 41 =-1 61 (F) 42=-63(F) 43=-63(F) 44=-63(F) 45=-63(F) 46�63(F) 47�63(1`) 48=-63(F) 49=-63(F) 50=-1 61 (F)
WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MIFTEK REFERANCE PAGEMII-7473 M. 1010312015 BEFORE USE.
Design valid for use onlyift MITek9 conneclors. This design is based only upon parameters shown. and Is for an Individual building component. no]
a truss system. Before use. the building designer must verify the applicability of design paramelers and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling or Individual truss web and/or chord members only. Additional tempOTUTY and permanent bracing WNW
Is always required (or stability and to prevent collapse vAth possible persond InJLuy and property daniage. For general guidance regarding the
fabrication, storage, delivery, eiection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Mexandflo. VA 22314. Tampa, FL 33610
Job ru s Truss Type Oly Ply R T13944727
M1 1420 GRB HIP GIRDER 1 1 Job Reference (optional)
unamDers I russ, inc., r-oit meice, rL .... ...
ID:-kfiGCA6bx7j2Syl HDXFw7ye3KX-d2TLrUzyJWPYV5zmabb?oGQQd3a?kQOhYMBdxQzKF]4
13-8-0 21-011 1-10 11-1-2 35-0-0 �16 0-)
-0 1_ 3_ IL_ __ I
0 0.� 1 15_ 14
N _1 g -1-2 3-10
4-0-_0 23-102-44 3�_21_� 6-8-0 i, 3
2
6
NAILED
Special NAILED NAILED NAILED NAILED NAILED Special
4.00 F12 4xB = NAILED NAILED 3x10 = 5xB WB= 3x5 I I NAILED NAILED SX8 =
4 26 . 27 28529 30 31 6 32 733 34 35 36 8 -A I
- am, - "m q
19 18 37 38 17 39 16 40 41 42
3X5 2x3 11 3x4 = NAILED 4x6 = 3x4 NAILED
Special
NAILED NAILED NAILED NAILED
16-6-11 21
7-0.0 13-8-0
b,E�i
43 Is 44 14 45 46 13 12
NAILED Gx10 = 3x6 = NAILED 3x4 2x3 11
NAILED NAILED Special
Scale = 1:60.3
3x4 =
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) Well Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.89 Ven(LL) 0.37 16-18 >695 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 1 EIC 0.85 Vert(C-0 -0.38 16-18 >669 240
BCLL 0.0 Rep Stress Incr NO WB 0.96 Horz(CT) 0.10 10 n1a n/a
BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Weight: 166 lb FT = 20%
LUMBER- BRACING-
TOPCHORD 2x4 SP M 30 'Except' TOPCHORD Structural wood sheathing directly applied or 3-8-13 oc puffins.
6-8: 2x4 SP M 31 BOTCHORD Rigid ceiling directly applied or 4-6-0 oc bracing.
BOTCHORD 2x4 SP M 30 WEBS 1 Row at midpt 5-15,8-15
WEBS 2x4 SID No.3 *Except*
5-15: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=1337/0-8-0,15=372210-8-0,10=52210-6-0
Max Horz 2=-78(LC 6)
Max Uplift 2=-1 1 78(LC 8),15=-2731 (LC 8), 1 0=-31 1 (LC 8)
Max Grav 2=1343(LC 17),15--3722(LC 1),,10=534(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3�3456/2833, 3-4=-3294/2597, 4-5=-2702/2220, 5-7=-1 387/1891, 7-8=-1 387/1891,
8-9=-807/281, 9-1 0=- 1090/466
BOTCHORD 2-19=-2609/3254, 18-19---2609/3254.16-18=-2365/3160,15-16=-2058/2702,
13-1 5=-1 80[772,12-13=-365/1014,10-12=-365/1014
WEBS 3-1 8=-282/498, 4-18--432/694, 4-16=-505/327, 5-16=-3211736, 5-15=-4770/3775,
7-15-946/855, 8-15=-2737/1803, 8-13=-237/686, 9-13=-386/330
NOTES-
1) Unbalanced root live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=35ft; eave=5ft; Cal.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1178 lb uplift at joint 2, 2731 lb uplift at
joint 15 and 311 lb uplift at joint 10.
7) "NAILED" indicates 3-1 Od (0.1 48"x3") or 3-12d (0. 1 48"x3.25") toe -nails per NDS guldlines.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 208 lb down and 319 lb up at
7-0-0, and 208 lb down and 319 lb up at 28-0-0 on top chord, and 386 lb down and 166 lb up at 7-0-0, and 386 lb down and 247 lb
up at 27-11-4 on bottom chord. The designtselection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate Increase=1.25
Thomas A. Alban! PE No.39380
MITek USA, Inc. FL Cort 6634
$904 Parke East Blvd. Tampa FL 33610
Date:
May 3,2018
n-Daae 2
wARNING. verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 1111-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with 1,AiTekO connectors. This design Is based only urx)n parameters shown, and Is for an Individual Wilding cornponeril, not
atTLW%YSte1n. Before use. the building designer must verityllre applicability of design poramelersand properly Incorporate thisclesIgninto the overall
building design, Bracing indicated is to prevent buckling of Individual truss web and/or chord merribeis only. Addfillonal temporary and permanent bracing
-MiTew
Is always required for stablilly and to prevent collapse with possible personal Injury and property clamage. For general guidance regarding the
fabrication. storage. delivery, erection and bracing of trusses and truss systems, sec-ANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
60-04 Parke East Blvd.
Safety Information avallable from Truss Plate Inslitule. 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FIL 33610
Job Truss I russ i ype T13944727
W1420 GRB HIP GIRDER 1
1, " I [Job Re
8.130sMar 11 201BMiTekIndustries, Inc. ThuMay 309:38:492018 Page2
Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Syl HDXFw7ye3Kx-d2TLrUzyJWPYV5zmabb?oGQQd3a?kQohYMBdxQzKF[4
LOAD CASE(S) Standard
Uniform Loads (plf)
Vert: 1-4-54, 4-8=-54, 8-11 �54, 20-23=-20
Concentrated Loads (lb)
Vert: 4�11 61 (8) 6=-1 16(B) 8=-1 61 (B) 18=-386(B) 13=-386(B) 26=-1 16(B) 27=-1 16(B) 28=-1 16(B) 30=-11 16(8) 31 =-1 16(B) 32=-1 16(B) 34=-1 16(8) 35=-1 1 6(B)
36=-1 16(B) 37=-63(B) 38�63(B) 39=-63(B) 40=-63(B) 41 =-63(B) 42=-63(B) 43=-63(B) 44=-63(B) 45�63(B) 46=-63(B)
WARNING- Verify design parameters and READ NOTES ON THIS AND tNCLUDEDMITEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only wilh Milek0connectots. This design is based only upon parameleis shown, and Is for an (ndIVIdUal bUilding component, nor
a fruss system. Before use, the building designer must Verify tile applicability of design parameters and pfopetly Incotporafe this design Into the overall
building design. Nac(ng [Micaled Is to prevent buckling of Individual ijuss web and/or chord members only. Additional lemporafy and permanept bracing .:M!Tek*
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 6904 Parke East Blvd.
rubrication, storage, delivery. erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component Tampa. Fl- 33610
Safety Information available from Truss Prale Instifule, 218 N. Lee Street. Suite 312, Alexandila, VA 22314.
R
0 Truss Truss Type Qty ly MANO T13944728
it Job Reference LqR!!M�L_
M 11420 J1 Jack -Open 8 1
Tm—a TfT61 8 —WiTek industries, Inc. Thu May 3 09:38:50 2018 Page I
Fort P ..... FIL 8A30
a b.�s Truss, In-=-, - 11A.k o-z,iwr)Yr: a4oXP6FXz7l6ELUzIRS7DT5EqnowBUtzKFI3
C
-1-0-0 1-0-0
1-0-0 1-0-0
3x4 =
1-0-0
LOADING (pSf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
Well
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.18
Vert(ILL)
-0.00
5
>999
360
TCDL
7.0
Lumber DOL
125
BC 0.02
Vert(CT)
-0-00
5
>999
240
BCLL
0.0
Rep Stress Incir
YES
WB 0.00
Horz(CT)
0.00
4
rda
n/a
BCDL
10.0
Code FBC2017fTP[2014
Malrix-MP
Wind(LL)
-0.00
5
>999
240
LIJIVIBER-
TOP CHORD 2x4 SP No.3
BOTCHORD 2x4SPNo.3
REACTIONS. (lb/size) 3=9]MeChanical,2=118/o-8-0,4=0/MechanicaI
Max Horz 2--48(LC 12)
Max Uplift 3=-4(LC 9), 2=-140(LC 12 i
Max Grav 3=10(LC 17), 2=118(LC 1), 4=)7(LC 12)
FORCES. Qb) - Max. Comp./Max. Ten. - All forc es 250 (ib) or less except when shown.
Scale = 1:6.1
PLATES GRIP
MT20 244/190
Weight: 5 lb FT = 20%
BRACING-
TOPCHORD Structural wood sheathing directly applied or 1 -0-0 oc puffins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.opsf; h=15ft; B—_45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and b-C Exterlor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60 1
2) This truss has been designed for a 10.0 psf bottom ch6rd live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0p�f on the bottom chord in all areas where a rectangle 3 6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other memb6rs.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at
joint 2.
Thomas A. Albani PE Na.39380
Welk USA, Inc. FL Cort 6634
6904 Parke East Blvd, Tampa Fl. 33610
Date:
May 3,201 E
-Verity design parameters and READ NOTES ON i.HIS AND INCLUDED MrTEK REpERANCE PAGE Ulf-7473 rev. 1010312015 BEFORE USE.
WARNING po is shown. and Is for an Individual building component. not
Design valid tot use ordy with MIT08 connectors. This design Lq based only u nparomeie nall
0 truss system. Before use. fire building designer must verify the applicability o(design parameters and property Incolporate, flits design Info the ove
building design. Bracing Indicated Is to prevent buckling of Individual truss web arid/or chord members only. Additional temporary (mid permanent bracing MiTek'
6- always required for stability and to prevent collapse with possible personal InfUrY and property damage. Fofgellercili]Ldd(3nceregcffcflrxI the
Illy Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
fabricollon, storage, delivery, erection and bracing of Inisseir and truss systems, seeANSI/TPII Qua Tampa, I'L 3361 D
Safety Information available frorn Truss Plate Institute. 218 N. Lee Street. Suite 312. Alexandria. VA 22314.
job
Tru S
Truss Type Q Ply NOR T13944729
M11420
J3
I �MA
Jack -Open Job Reference (optionall_
44 — - nai— Industries In, Thu May '3 09:38:650 2018 Pap 1
Chambers Truss, Inc., Fort Pierce, IL .. I .. . n'..' I I — 1 —.1. —, ...- -1
ID:_kfiGCA6bx7i2Syl HDXFw7ye3KX-5Elj3q-a4qXP6FXz7l6ELUzIOS5dT5EqnOwBUtzKFI3
-i'l-W 1 3-0-0
I 3x4 =
LOADING (psi)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
Vdefl
Ud
TOLL
20.0
Plate Grip DOL
1.25
TO 0.18
Vert(LL)
-0.00
7
>999
360
TCDL
7.0
Lumber DOL
1.25
BC OAS
Vert(CT)
-0.01
4-7
>999
240
BOLL
0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n1a
n1a
BCDL
10.0
Code FBC2017fTP12014
MaIrix-MP
Wind(LL)
0.01
4-7
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=63/Mechanical,2=17210-8-0,4=36/MechanicaI
Max Herz 2=85(LC 12)
Max Uplift 3=-54(LC 12), 2=-1 46(LC 12),,4�4(1_13 12)
Max Gram 3=63(LC 1), 2=172(LC 1), 4=5,b(LC 3)
1
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
I
Scale = 1:9.4
PLATES GRIP
MT20 244/190
Weight: 11 lb FT = 20%
BRACING-
TOPCHORD Structural wood sheathing directly applied or 3-0-0 oc puffins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES- I
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.opsf; h=15ft; B=45ft; L=241t; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interfor(l) 2-0-0 to 2-11-4 zone-,C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psi bottom ch6rd live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0p�f on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other memb6rs.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 146 lb uplift at joint
2 and 4 lb uplift at joint 4.
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Citit 0634
8904 Parke East Blvd. Tampa Fl. 33610
Date:
May 3,2018
WARIVINCi. Verify design parameter. and READ NOTESON THIS AND INCLUDED MITEKREFERANCE PAGEUII-7473 rev. 1010312019 BEFORE USE.
Design valldfor use odywilh MITek8 connectors. This desIgnJs based only upon parainblersshown. and Is for an Individual building component. not
a trusssyslein. Before use. the building designer Must verify fheapplicablilly ofolesign pjiumelers and pioperlyMcorporale this designinlo the overall
building design. Bracing Indicated Is to prevent bucking of Individual truss web and/or chord mernbefs only. Additional temr;orary and permanent bracing M!Tek*
is always recidred for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI. Building Component 6904 Parke East Blvd,
Safety information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610
M11420
Jack -Open
Ply
T13944730
3x4 =
8.130 s Mar 11 2018 MiTek Industries, Inc. Thu May 3 09:38:51
ID:_kfiGCA6bX7i2Syl HDXFw7ye3KX-ZRa5GA_DrBfGkP6ghOdTuhVnrs]KCYT
5-0-0
5-0-0
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
Udell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.71
Vert(LL)
-0.03
4-7
>999
360
TC;DL
7.0
Lumber DOL
1.25
BG 0.67
Vert(CT)
-0.06
4-7
>977
240
BCLL
0.0
Rep Stress Incr
YES
WI3 0.00
Horz(CT)
-0.00
3
ri/a
n1a
BCDL
10.0
Code FBC2017fTP12014
Matrix -MP
WInd(U-)
0.07
4-7
>904
240
Scale= 1:12.7
PLATES GRIP
MT20 244/190
Weight: 17 lb FT = 20- .
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=114/Mechanical,2=242/0-8-0,4=63/MeChanicaI
Max Horz 2=123(LC 12)
Max Uplift 3=-1 04(LC 12), 2=-1 77(LC 12), 4=-9(LC 12)
Max GraV 3=1 14(LC 1), 2=242(LC 1), 4=87(LC 3)
i
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=l 65mph (3-second gust) Vas d=1 28mph; TCDL=4.2pst; BCDL=3.Opsf; h=1 51t; B--45ft; L=24ft; eave=4ft, Cat.
11; Exp C; Encl., GCpl=o.l 8; MW FPS (directional) andl C-0 Exterjor(2) -1 -0-0 to 2-0-0, Interior(l) 2-0-0 to 4-11-4 zone;C-C for
members and forces & MWFRS for reactions shown; I Lumber DOL--1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0pst on the bottom chord in ail areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9 Ito uplift at joint 4.
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke Ea9t Blvd. Tampa FL 33610
Date:
May 3,201 E
WARNING. Verify design parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCE PAGEMII-7473 rev. 1010312015 BEFORE LYSE-
Design valid for use onlywIth MITek0conneclors. Thisdesign isbased onlyupon pofametelsshown, and Is for an Individual building component, not
a IrLM systern. Before use, the building designer must verity the cipplicablilly of design pal(Nnet919 and property Incorporate this design into the overall
Ming of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
building design. Bracing Indicated Is to prevent buc j1dance regarding the
Is always required for stability and to prevent collapse with possible persond Injury and property claInage. FOY general OL 6904 Parke East Blvd.
fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeANSI17PI1 Quality Criteria, DSB-89 and BCSI Building Component Tampa, FL 33610
Safety Information available from Truss Plate Insfilule. 218 N. Lee Street. Suite 312, Alexandria. VA 22314.
Truss I Truss Type
M1 1420 1,17 1 Jack -Open 124
T13944731
Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu May 3 09:38:51 2018 Page I
ID:-kfiGCA6bx7i2Syl HDXFw7ye3KX-ZRa5GA-Dr8fGkP69hOdTuhVrfsDECY-[�-OggkOJzKFI2
7-0-0
7-0-0
0 1
Scale: 3/4"=l'
3x4 �
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) 1 11 Ud PLATES GRIP
Plate Grip DOL 1.25 TC 0.47 Vert(LI-) -0.10 4-7 -/d:7
TCLL 20.0 �8 360 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.99 Ven(CT) -0.21 4-7 >388 240
13CLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a. n/a
BCDL 10.0 Code FBC2017frPI2014 Matrix -MP Wind(LL) 0.18 4-7 >469 240 Weight: 23 lb FT = 20%
LUMBER -
TOP CHORD 2X4 SP M 30
BOTCHORD 2x4SPNo.3
REACTIONS. (lb/size) 3=170/Mechanical, 2=315/0-8-0, 4=83/Mechanical
Max Horz 2=1 61 (LC 12) 1
Max Uplift 3=-1 56(LC 12), 2=-210(LC 12). 4=-9(LC 12)
Max Grav 3=170(LC 1), 2=315(LC 1), 4=1 20(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BRACING-
TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOTCHORD Rigid ceiling directly applied.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B--45ft; L=24ft; eave--4ft; Cat.
11; Exp C; Encl., GCpi--0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interion(l) 2-0-0 to 6-11-4 zone;C-C for
members and forces & MWFRS for reactions shown;� Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 156 lb uplift at joint 3, 210 lb uplift at
joint 2 and 9 lb uplift at joint 4.
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
May 3,2018
WARNING - Verify design parameters and READ NOTES ON THISANDINCLUDED NITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MlTek@) conneclors. This design Is based only upon parameters shown. and Is for an Individual building component, not
a truss system. Before use, the building designer Must verify the applicability of design pararnelers and properly Incorporate Bits dosign into the overall
building deslgn. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
-MiTek*
Is always recrulred for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fatsicallon. storage, delivery, erection and bracing of trusses and truss systems, SeeANSIITPI 1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke Easf Blvd.
Safety Information available from Truz Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FIL 33610
___TD'iagonaI Hip Girder 4
Truss
J0 __7 Truss Type Opy
M 11420 KJ7
T13944732
8.130 s Mar 11 2018 M I I eK I nausines, inc. I FILI lVidy 0 UW-0
s, Inc., Fort Pierce, FL ID.-kfiGGA6bx7j2SY1 HDXFw7ye3KX-ldBUUW?rcRn7MYhLFjBiQV24WGkC
Q-1n.1
5-3-16 4-6-1
_11-55-00 6-3-15
3x4 = NAILED NAILED NAILED
Srale = 1:21.2
5-3-
4-5-6
0-0212
SPACING-
2-0-0.
CS1.
DEFL. in
(loc) I/def] Ud
240
PLATES
MT20
GRIP
244/190
LOADING (psf)
TCLL 20.0
Plate Grip DOL
1.25;
TC 0.20
Vert(LL) 0.05
6-7 >999
TCDL 7.0
Lumber DOL
1.25'
BC 0.30
Vert(CT) -0.07
6-7 >999 240
BCLL 0.0
Rep Stress Incr
NO
WB 0.44
Horz(CT) 0.01
5 n1a. n/a
Weight: 40 lb
FT = 20%
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
LIUMBER-
BRACING -
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
TOP CHORD 2x4 SIP M 30
BOTCHORD
Rigid ceiling directly applied or 9-0-2 oc bracing.
BOTCHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=121/Merhanical,2=501/Ci-10-15,5--352IMechanicaI
Max Horz 2=1 60(LC 8)
Max Uplift 4=-1 15(LC 8), 2=-365(LO 8), 5=-1 90(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3�11067/585
BOTCHORD 2-7=-660/1026, 6-7=-660/1026
WEBS 3-7�37/280, 3-6=-1073/690
NOTES-
1) Wind: ASCE 7-10; Vult=165Mph (3-second gust) Vasd=128mph; TCDL=4.2pst; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0pslf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss Connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 115 lb uplift at joint 4, 365 lb uplift at
joint 2 and 190 lb uplift at joint 5.
6) "NAILED" indicates 3-1 Od (0.1 48"x3") or 2-12d (0.1 48"x3.25") toe -nails per NDS guidlines.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-4=-54, 5-8=-20
Concentrated Loads (lb) B-38) 13=-7(F=-3, B=-3) 14=-20(F=-l0, B=-1 0) 15=-69(F=-34, B=-34)
Vert: 11=-3(F=-1,B=-1)12=-76(F=-38 7
6
Ch
C�
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cert 6634
8904 Parke East Blvd. Tampa Fl. $3610
Date:
May 3,201 E
A& WARNING. verify design parameters and READ NOTES DIV THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valld for use only vAfh MITekO contm-ciors. This design is based only upon parameters shown, and Is for an Individual building component. not
a truss system. Before tise, the buildIng designer must verify the applicability of design parameters and property Incorporate [his design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeV
Ally and to prevent collapse vAth possible personal Injury and property damage. For general guidance regarding the 6904 Parke East Blvd.
Is dways required for stal: fly Criteria, DSB-89 and SCSI Building Component
fabrication, storage, delivery. erection and bracing of trusses and truss systems. seeANSI/TPI I Qual Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 3 12. Alexandria. VA 22314.
Symbols
PLATE LOCATION AND ORIENTATION
31; Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenfhs.
Apply plates to both sides of truss
and fully embed teeth.
0-111g,
-t-
For 4 x 2 orientation, locate
plates 0- 110 from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MiTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
width measured perpendicular
4 x 4 to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
indicates location where bearings
(supports) occur. icons vary but
reaction section indicates joint
number where bearings occur,
Min size shown is for crushing only.
industry Standards:
ANSI/TP11: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 1 imensions,s a
cli h wn In ft-in-sixteenths
(Draw ngs not to scale)
2
TOP CHORDS
0
CLI
0
JOINTS ARE GENERALLY NUMSEREDILETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
[CC -ES Reports:
ESR- 1311, ESR- 1352, ESR 1988
ER-3907, ESR-2362, ESR- 1397, ESR-3282
a
CL
0
0
CL
0
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are -in accordance with ANSI/TPI - 1
section 6.3 These truss designs rely on lumber values
established by others.
0 2012 MiTek8 All Rights Reserved
7- 7
AIL
7iivi
IvIlTek Engineering Reference Sheet� IVIII-7473 rev. 10/03/2015
A General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal injury
I . Additional stability bracing for truss system, e.g.
diagonal or X-brocing. is always required. See BCSI,
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stock materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear fightly against each other.
6. Place plates on each face of truss at each
joint and embed fully, Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSIfTPI 1.
8. Unless otherwise notecl, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted. this design Is not applicable for
use with fire retardant, preservative treated, or green lumber.
10, Comber is a non-structurol consideration and Is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
Indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
In all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted,
15, Connections not shown are the responsibility of others.
16, Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless Indicated otherwise,
1 B. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture In accordance with
ANSI/TPI 1 Quality Criteria.