HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE _D+= Planning& Development Services Department
s Building&Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553
4GANNFZ
Certification for Design Load Compliance By
Project Name:
Uncle Bobs Self Storage Facility#011 tludplc0�
I
Project Address: 8531 South US HWY 1
Permit#: N/A Occupancy Type: Group S-1 Construction Type:1i B
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record.
• Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family) pwu PU 17
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovatioi ns provided that no exterior structural elements are affected and
certain minor building permits at the discretion i f the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 15 Supplements using ASCE 7-10
2. Structure Designed as(check one): x Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph X ASD LRFD -End Zone Width: 6.0 ft
5. Mean Roof Height iz.a2 ft I Roof Pitch: 3.6 :12 Parapet: 6.0 ft
1
6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings):
Zone 1:-56 Zone 2: -94 Zone 3: -141 Zone 4:-55 Zone 5:-68 Garage: N/A
7. Design Loads: Floor: 125 PSF Roof/Dead: 15 PSF Roof/Live: 20 Balcony: "" PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans &specifications have been designed to
comply with the a neI' able structural portions of the building codes currently adopted and enforced by St. Lucie
County\ cer ost ructural elements depicted on these plans provide adequate resistance to the design
forc
��G E N Ale
S�• Paul D. Fleming FL PE#35819
Q�. '•G1
$ Print Name Cert#&Co.Cert Auth.
+�O �� Paul D. Fleming(Sole Proprietor)
Z77 STATE OF
Sign PR ��� 16 Essay Dr., Little Rock,AR 72223
�01- ��QNA1_;;;�\\\ Company Name&Address
/11111
Revised 07/25/2014 t 0'`�