Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE _D+= Planning& Development Services Department s Building&Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 4GANNFZ Certification for Design Load Compliance By Project Name: Uncle Bobs Self Storage Facility#011 tludplc0� I Project Address: 8531 South US HWY 1 Permit#: N/A Occupancy Type: Group S-1 Construction Type:1i B INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. • Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) pwu PU 17 o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovatioi ns provided that no exterior structural elements are affected and certain minor building permits at the discretion i f the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 15 Supplements using ASCE 7-10 2. Structure Designed as(check one): x Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph X ASD LRFD -End Zone Width: 6.0 ft 5. Mean Roof Height iz.a2 ft I Roof Pitch: 3.6 :12 Parapet: 6.0 ft 1 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1:-56 Zone 2: -94 Zone 3: -141 Zone 4:-55 Zone 5:-68 Garage: N/A 7. Design Loads: Floor: 125 PSF Roof/Dead: 15 PSF Roof/Live: 20 Balcony: "" PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans &specifications have been designed to comply with the a neI' able structural portions of the building codes currently adopted and enforced by St. Lucie County\ cer ost ructural elements depicted on these plans provide adequate resistance to the design forc ��G E N Ale S�• Paul D. Fleming FL PE#35819 Q�. '•G1 $ Print Name Cert#&Co.Cert Auth. +�O �� Paul D. Fleming(Sole Proprietor) Z77 STATE OF Sign PR ��� 16 Essay Dr., Little Rock,AR 72223 �01- ��QNA1_;;;�\\\ Company Name&Address /11111 Revised 07/25/2014 t 0'`�