Loading...
HomeMy WebLinkAboutREVIEW-COMMENTS REVIEW COMMENTS RECEIVED Planning$�Development Services ` Building&,Code Regulation Division 2300 Virginia Avenue A U G 0 1 2018 ._.. Phone;(772J462.2172 Fax:(772)462.6443 �OR ST. Lucie GAun , Permitting iL Moo PROPERTY INFORMATION Address: 5102 Palmetto Ave Owner(s): I ' Janet S Bergen/Richard D Bergen City/State/Zip: Fort Pierce, FI 34982 Parcel#: 3404-501-0620-300/2 Jurisdiction: ST LUCIE COUNTY Zoning: RS-3 Lot#: 15 Block: 75 APPLICATION INFORMATION i Permit Number: 1806-0250 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION z Contractor Name: Jamison Brownie Fax Number: 772-460-5650 Business Name: Brownie Companies, Llc f5'� v Business Addr: 175 Boyd Road Email: Info@Brownie y Companies.Com City/State/Zip: Fort Pierce, FI 34 945 REVIEWS AND COMMENTS Review Type Status (Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING (Audrey Humphrey 6/11/2018 6/11/2018 Comment: E DSAF[LLE L"A1 R S . 6/11/2018 Comment FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 6/11/2018 6/11/2018 6/11/2018 Comment: PE REVIEW COMMENTS(2) INCOMPLETE William Durden 6/21/2018 a� r Comment: �tSE�S ACOiilSTP N ��I()t� f&�� ;� i E5 �I�� T 6/21/2018 RDU N � xr Comment: NO FLOOD VENTS IN THE GARAGE AREA ARE SHOWN ON THE PLANS.FLOOD VENTS WILL BE REQUIRED FOR THIS LOCATION IF THE FFE IS BELOW THE BFE OF AE7+1 FT. PLEASE SHOW THE LOCATION OF THE FLOOD VENTS ON THE FLOOR PLAN AND THE ELEVATION PLANS MEETING THE REQUIREMENTS OF 6/21/2018 CHAPTER 3,SECTION R322,AND SUB-SECTION R322.2.2.OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: •PLEASE ADD TO THE CONSTRUCTION DOCUMENTS SHALL INCLUDE A STATEMENT BY A REGISTERED DESIGN PROFESSIONAL THAT THE DESIGN OF THE OPENINGS WILL PROVIDE FOR EQUALIZATION OF 6/21/2018 HYDROSTATIC FLOOD FORCES ON EXTERIOR WALLS BY ALLOWING FOR THE AUTOMATIC ENTRY AND EXIT OF FLOODWATERS AS SPECIFIED IN SECTION 2.7.2.2 OF ASCE 24.PER CHAPTER 3,SECTION R322, SUB-SECTION R322.2.2,AND FOOT NOTE 2.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: •PLEASE ADD TO THE SIGNED AND SEAL CONSTRUCTION DOCUMENTS THE INFORMATION THAT IS 6/21/2018 REQUIRED BY CHAPTER 3,SECTION R322,AND SUB-SECTION R322.3.6 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. t ' 1 Planning&Development services REVIEW COMMENTS j Building&Code:Regulallon Divislon ! 23a0 Virginia Avenue i Fort Ple(ce;FL=82 Phone:(772)462.2172 0ax:(772)462.6W Page 2 Comment: •PLEASE SUBMIT A DETAIL FOR THE FLOOD VENT OPENINGS MEETING THE REQUIREMENTS OF 6/21/2018 CHAPTER 6,SECTION R606,AND SUB-SECTION R606.10 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: •PLEASE ADD TO THE PLANS THE CALCULATIONS OF THE FLOOD VENT REQUIREMENTS TO REFLECT 6/21/2018 HOW MANY FLOOD VENTS ARE REQUIRED FOR EACH LOCATION.PER CHAPTER 3,SECTION R322,SUB- SECTION R322.2.2,AND FOOT NOTE 2.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. J Comment: •PLEASE SHOW ON THE PLANS THE ELEVATION OF THE MECHANICAL PADS MEETING THE I 6/21/2018 REQUIREMENTS OF CHAPTER 3,SECTION R322,SUB-SECTION R322.1.6 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. P- Comment: Pt_ ASI ,SI7BM[ AL. U O,N7�O,T S=AIaR E/IENYS t=OR T E R COh�iNECT[�ly' ,FTHE,MELN KCAL,, 6l21/2018 "'�� a � � x-� 6/21/2018 Comment: �IO,TE'ANY THEIiE�IQV10 S TG} HE SR�JOTJ,RE OrTFiER THANWFaHT(SSHOW fJNn 1 EEC i SUBMIED PLIVS1lIt DEED TO BE�PERIAIED S�PARA 1 Ei_Yus� ` i Comment: •NO PRODUCT APPROVAL,PRODUCT APPROVAL NUMBER,OR[CC CERTIFICATION WAS SUBMITTED FOR 6/21/2018 THE FLOOD VENTS.PLEASE SUBMIT THE CORRECT PRODUCT APPROVAL NUMBER ON PLANS OR SUBMIT THE PRODUCT APPROVAL IN DUPLICATE.SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. } Comment: NO DETAILS ON THE PLANS FOR THE STAIRS REQUIRED FROM THE GARAGES TO THE MAIN STRUCTURE. I 6/21/2018 •PLEASE FURNISH AN EXTERIOR STAIR DETAIL SHOWING STAIR WIDTH, RISER HEIGHT,TREAD DEPTH, HAND RAIL HEIGHT AND GRIP SIZE IN ACCORDANCE WITH SECTION R311.7 AND R312 OF THE 2017 { FLORIDA RESIDENTIAL CODE. Comment: NO DETAILS ON THE PLANS FOR THE STAIRS REQUIRED FOR THE PATIO AREA. •PLEASE FURNISH AN 6/21/2018 EXTERIOR STAIR DETAIL SHOWING STAIR WIDTH, RISER HEIGHT,TREAD DEPTH,HAND RAIL HEIGHT AND i GRIP SIZE IN ACCORDANCE WITH SECTION R311.7 AND R312 OF THE 2017 FLORIDA RESIDENTIAL CODE. 6/21/2018 Comment: •PLEASE FURNISH DETAIL FOR EXTERIOR GUARD RAILS BEING IN ACCORDANCE WITH SECTION 312 OF THE 2014 FLORIDA RESIDENTIAL CODE. PLANS EXAMINER REVIEW COMPLETE William Durden 6/21/2018 6/21/2018 6/21/2018 Comment: ZONING REVIEW INCOMPLETE Lydia Galbraith 6/19/2018 Fl- CommentL'EASEPRO�/13E2CPDAfEDSU VYIGNI=D11 5 `ALEt3JBlSURVYOR53T{ E,SUEa'�WILLEED" TO IND(C'ATE�T1 Mt:' LLOWt EORNf1�i fON ' LL EVTE � �hA T. 6/21/2018 ARAGE a �T� I��PRnP,�OSED• �00,>!!33 E�EhTN�O ,q L�51�E1'�ii�t�.�pR�. E�EY��TIfJN�CE ERk�NE`AF�CNTE�-F10R � :, ` EVA dfON®F'G ADAf�°01 IS�T�'Rl>;G'T't'JPi � f '0a 02- S-0 RECEIVED AUG 01 2018 ST. Lucie county, Permitting a Planning B Development Services REVIEW COMMENTS Building&Code Regulation Division, 2300 Virginia Avenue Fort Pierce,FL. 34982• Phone:(772)462-2172 Fax:(772)462-6443 Page 1 PROPERTY INFORMATION Address: 5102 Palmetto Ave Owner(s): Janet S Bergen/Richard D Bergen City/State/Zip: Fort Pierce, FI 34982 Parcel#: 3404-501-0620-300/2 Jurisdiction: ST LUCIE COUNTY Zoning: RS-3 Lot#: 15 Block: 75 APPLICATION INFORMATION Permit Number: 1806-0250 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Jamison Brownie Fax Number: 772-460-5650 Business Name: Brownie Companies, Llc Business Addr: 175 Boyd Road Email: Info@BrownieCompanies.Com City/State/Zip: Fort Pierce, FI 34945 REVIEWS AND COMMENTS ReviewTyoe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Audrey Humphrey 6/11/2018 I 6/11/2018 Comment: NEEDS A FILLED LANDS AFFIDAVIT. 6/11/2018 Comment: CONTRACTOR OF RECORD IS ON HOLD AND NEEDS TO UPDATE WITH CONTRACTOR'S LICENSING. FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 6/11/2018 6/11/2018 6/11/2018 Comment: PE REVIEW COMMENTS(2) INCOMPLETE William Durden 612112018 Comment: PLEASE SUBMIT A PRECONSTRUCTION ELEVATION CERTIFICATE FOR REVIEW.SEE SECTION 107 OF THE 6/21/2018 2017 FLORIDA BUILDING CODE. Comment: NO FLOOD VENTS IN THE GARAGE AREA ARE SHOWN ON THE PLANS.FLOOD VENTS WILL BE REQUIRED FOR THIS LOCATION IF THE FFE IS BELOW THE BFE OF AE7+1 FT. PLEASE SHOW THE LOCATION OF THE FLOOD VENTS ON THE FLOOR PLAN AND THE ELEVATION PLANS MEETING THE REQUIREMENTS OF 6/21/2018 CHAPTER 3,SECTION R322,AND SUB-SECTION R322.2.2.OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: -PLEASE ADD TO THE CONSTRUCTION DOCUMENTS SHALL INCLUDE A STATEMENT BY A REGISTERED DESIGN PROFESSIONAL THAT THE DESIGN OF THE OPENINGS WILL PROVIDE FOR EQUALIZATION OF 6/21/2018 HYDROSTATIC FLOOD FORCES ON EXTERIOR WALLS BY ALLOWING FOR THE AUTOMATIC ENTRY AND EXIT OF FLOODWATERS AS SPECIFIED IN SECTION 2.7.2.2 OF ASCE 24.PER CHAPTER 3,SECTION R322, SUB-SECTION R322.2.2,AND FOOT NOTE 2.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: -PLEASE ADD TO THE SIGNED AND SEAL CONSTRUCTION DOCUMENTS THE INFORMATION THAT IS 6/21/2018 REQUIRED BY CHAPTER 3,SECTION R322,AND SUB-SECTION R322.3.6 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Planning&Development services REVIEW COMMENTS Building&Code Regulation Division. 2300 Virginia Avenue Fort Pierce,FL: 34982. Phone:(772)462.2172 Fax:(772)462.6443 Page 2 Comment: -PLEASE SUBMIT A DETAIL FOR THE FLOOD VENT OPENINGS MEETING THE REQUIREMENTS OF 6/21/2018 CHAPTER 6,SECTION R606,AND SUB-SECTION R606.10 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: -PLEASE ADD TO THE PLANS THE CALCULATIONS OF THE FLOOD VENT REQUIREMENTS TO REFLECT 6/21/2018 HOW MANY FLOOD VENTS ARE REQUIRED FOR EACH LOCATION.PER CHAPTER 3,SECTION R322,SUB- SECTION R322.2.2,AND,FOOT NOTE 2.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: -PLEASE SHOW ON THE PLANS THE ELEVATION OF THE MECHANICAL PADS MEETING THE 6/21/2018 REQUIREMENTS OF CHAPTER 3,SECTION R322,SUB-SECTION R322.1.6 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 6/21/2018 Comment: PLEASE SUBMIT ALL SUB-CONTRACTORS AGREEMENTS FOR THE RECONNECTION OF THE MECHANICAL, ELECTRICAL AND PLUMBING. 6/21/2018 Comment: PLEASE NOTE ANY OTHER RENOVATIONS TO THE STRUCTURE OTHER THAN WHAT IS SHOWN ON THE SUBMITTED PLANS WILL NEED TO BE PERMITTED SEPARATELY. Comment: -NO PRODUCT APPROVAL,PRODUCT APPROVAL NUMBER,OR ICC CERTIFICATION WAS SUBMITTED FOR 6/21/2018 THE FLOOD VENTS.PLEASE SUBMIT THE CORRECT PRODUCT APPROVAL NUMBER ON PLANS OR SUBMIT THE PRODUCT APPROVAL IN DUPLICATE.SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: NO DETAILS ON THE PLANS FOR THE STAIRS REQUIRED FROM THE GARAGES TO THE MAIN STRUCTURE. 6/21/2018 -PLEASE FURNISH AN EXTERIOR STAIR DETAIL SHOWING STAIR WIDTH, RISER HEIGHT,TREAD DEPTH, HAND RAIL HEIGHT AND GRIP SIZE IN ACCORDANCE WITH SECTION R311.7 AND R312 OF THE 2017 FLORIDA RESIDENTIAL CODE. Comment: NO DETAILS ON THE PLANS FOR THE STAIRS REQUIRED FOR THE PATIO AREA. -PLEASE FURNISH AN 6/21/2018 EXTERIOR STAIR DETAIL SHOWING STAIR WIDTH, RISER HEIGHT,TREAD DEPTH,HAND RAIL HEIGHT AND GRIP SIZE IN ACCORDANCE WITH SECTION R311.7 AND R312 OF THE 2017 FLORIDA RESIDENTIAL CODE. 6/21/2018 Comment: -PLEASE FURNISH DETAIL FOR EXTERIOR GUARD RAILS BEING IN ACCORDANCE WITH SECTION 312 OF THE 2014 FLORIDA RESIDENTIAL CODE. PLANS EXAMINER REVIEW COMPLETE William Durden 6/21/2018 6121/2018 6/21/2018 Comment: ZONING REVIEW INCOMPLETE Lydia Galbraith 6/19/2018 Comment: PLEASE PROVIDE 2 UPDATED SURVEYS,SIGNED AND SEALED BY SURVEYOR.THE SURVEY WILL NEED TO INDICATE THE FOLLOWING INFORMATION: -ALL ELEVATIONS WILL NEED TO BE IN NAVD 6/21/2018 -EXISTING FLOOR ELEVATION OF SFR AND THE GARAGE. -THE PROPOSED FLOOR ELEVATION OF BOTH SFR AND GARAGE. -ELEVATION CENTER LINE OF THE ROAD. -ELEVATION OF GRADE AROUND STRUCTURE.