HomeMy WebLinkAboutLETTER OF INSPECTION Kennedy Engineering, LLC
332 SW 7"`Fen-ace•Boca Raton,FL 33486•Phone: 561-573-1679
GMail:ev,-uikeiiiied),I@gmail.com RECEIVED
Date: September 24, 2018 ��u4 ¢ S E P 2 7 2018
Project#: 18-BO-001 ST. LUCla County, Permitting
City Port St. Lucie Building Department
121 SW Port St. Lucie Blvd.
St. Lucie, FL 33984
I
Reference: Permit No. 1806-0192
Orlando Residence
7678 Wexford Way
Port St. Lucie, FL 34986
As-built Certification
I
Building Official:
This letter is to certify that I have inspected the work completed the above referenced project and I am approving the work
as completed with the following modifications from the approved plans are acceptable.
1. The Simpson H10A clip attachment to truss and 2x detail A-A on Sheet R3 is acceptable as installed with 8 total
nails to the trusses and (4)total nails to the 2x Tember.
2. The attachment at the bottom of the steel columns have been installed per the plans with (4) 5/8" Simpson Titen
HD concrete screws with a minimum 3" embed.
3. The 2x4 bearing column (7—2x4 tied together) to bottom plate/slab connection is acceptable as installed with an
MSTA36 strap tie fully wrapped around the column and tied to the slab through the bottom plate.
4. The 2x4 bearing column located at the bedroom sliding glass door is acceptable as installed with an MSTA24
strap tie fully wrapped around the column and tied to the slab through the bottom plate.
The work completed conforms with the requirements of :he project, meets engineering standards and meets the
requirements of the 6th Edition of the Florida Building Code(2017).
If you hake°�a�y Wp 19't O®quire additional information pertaining to this project, please do not hesitate to contact me.
.Q
Sincq� I e' No 69895
o
°LC:,
p'• A% F
0
Evan L.' ,.F E.�'�C�®e°°°
FL P.E.# NAL 0e�% 0.
amtoa�
Kennedy Engineering, LLC
332 SW 7th Terrace
Boca Raton FL, 33486
CA#29980