Loading...
HomeMy WebLinkAboutREVISION 3-29-18 OFFICE USE ONLY: SCANNkU ` DATE FILED: of PERMIT# SLC-1704-0137 REVISION FEE: 7S'Oc � r„hi���d RECEIPT# PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE • FORT PIERCE,FL 34982.5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE �± � row ADDRESS: _. <. 260 SE Prima Vista Blvd(SW corner SW Prima Vista Blvd and Floresta Drive) A. ti v DETAILED DESCRIPTION OF PROJECT REVISIONS: Signed and sealed shop drawings for structural steel members,reviewed by DP of Record CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: CGCO61217 ST. LUCIE CO CERT.#: BUSINESS NAME: Hooks Construction Co QUALIFIERS NAME: Steven C.Hooks ADDRESS: 2211 S.Kanner Highway CITY: Stuart STATE: FL ZIP: 34994 PHONE(DAYTIME): 772-419-8828 FAX: 772-237-3757 OWNER/BUILDER INFORMATION: NAME: Wawa Florida LLC ADDRESS:7022 TPC Drive,Suite 200 _ CITY: Orlando STATE: FL ZIP: 32822 PHONE(DAYTIME: 610-358-8000 FAX: • ARCHITECT/ENGINEER INFORMATION: NAME: Cuhaci&Peterson ADDRESS: 1925 Prospect Avenue CITY: Orlando STATE: FL ZIP: 32814 PHONE(DAYTIME): 407-661-9100 FAX: 407-661-9101 SLCCC: 9123109 Revised 06130117 RF�/Eo MAR Permitting bPa e St.Lucle C tr ent STEELTEC 3901 Roswell Rd., Suite 111 SHT: CS page 1 of 5 9 Marietta, GA 30062 Date 3-23-18 770-505-5917 BY: RB Client: Wawa#5220-FLO Description: Wawa Canopy-Laminated Gutter Support Panel Structural Calculations Steeltec Job, Wawa#5220-FLO-Port ST. Lucie, ST. Lucie County, FL Roof Load: 20 PSF Live Load 3 PSF Panel Dead Load Wind Load: Risk Category II, 170 MPH, EXP. C, 3 Sec Gust Steel Deck-ASTM A653 GR. 50- Fy-- 50.0 ksi References: -2017 Florida Building Code 6th Edition (2017 FBC) -2015 International Building Code (2015 IBC) -ASCE 7-10 Minimum Design Loads for Buildings and Other Structures -AISC Manuel of Steel Construction— 14th Edition -AISI Specification for the Design of Cold Formed Steel Structural Members-2007 Edition Reviewed, ❑Furnish as Corrected No Comments 0 Revise and Resubmit Rejected ❑Submit Spucinc Item This review is only ror gneral conformance with the doWgit comxpt or the pr<wd and general compliance with the information given in the Gmtrod Documents.Corrections �`\\\ or comments made on the shop drawing \GK A e during the review do not relieve contractor from complianve with the requirements or \\\,Q�;'��GEN`sl��`�t^ the plans and speeiliunions. Approval of a specific item sludl not include approval or an ` assembly of which ttu+item is a Component. No.507 1 Contractor is resliomible for:dimensions to ; n * _ be confirmed and correlated at the InformationJolxite; - f 1 ' Information that pertains solely to the '0 1 STATE OF %[il Z fabrication procc"s. or to the meats. ,A methods, techniques, sequences, and j o procedures or construction; coordination of // �,R� the Work with that of all trades; and for / OR. performing all work in a wife and satiefaetory �1///s��pNALt CUHACI&PETERSON ARCHITECTS,LW I 1!1 Date 3 u i8 sy f� MAR 2 3 `2010 STEELTEC - SHT: 2 of 5 ' DATE: 3-23-18 BY: RB Description: Wawa Canopy-Laminated Roof Panel Laminated Panel Analysis 2" Laminated Panel @ Gutter Dead Load=3 psf Span=6'-3" Components & Cladding Wind Load for Open Building—Table 30.8-1 Step 1 : Risk Category II per Table 1.5-1 Step 2 : Charlotte County— 170 mph wind speed per FBC Step 3: Kd =0.85 per table 26.6-1 Exposure "C" per Section 26.7 Kzt= 1.0 per Figure 26.8-1 Gust Effect Factor G=0.85 per Section 26.9 Step 4: Kz=0.90 per Table 30.3-1 Step 5: Qh=(0.00256)(Kz)(Kd)(V)2= Qh= (0.00256)(0.90)(1.0)(0.85) )(170)2=56.6 Equation 30.3-1 Step 6:=Determine Factor Cn: Monoslope Roof per Fiqure 30.8-1. Roof Slope=2:12=9.46 degrees By Extrapolation, Cn=+1.65 or-1.53 Step 7: Wind Pressure per Eq. 30.8-1 p=(Qh)(G)(Cn) Positive Pressure: p=(56.6 pdf)(0.85)(1.65)=79.4 psf Negative Pressure: =p=(56.6)(0.85)(-1.53)_-73.6 psf STEELTEC SHT: 3 OF 5 DATE: 3-23-18 BY: RB DESCRIPTION: WAWA CANOPY-LAMINATED ROOF PANEL LAMINATED PANEL ANALYSIS 2"Laminated Panel @ Gutter Dead Load= 3 psf Span 6'-3" Combination Loads: LL=20 psf DL= 3 psf Combination A : (0.6)(DL)+(0.6)WL)=(0.6)(3.Opsf)+(0.6)(-73.6psf)=-42.4 psf Combination B: DL+(0.75) [(0.6)(LL)+WL]= 3 psf+(0.75)[ (0.6)(79.4 psf)+20 psf] =53.73 psf. 53.73 psf>42.4 psf thus Combination B indicates: Per Attached Tables, MAX. Allowable Pressure for 6'-3"is 54 psf. Table is for"externally" imposed load, thus it does not include the DL Dead Load+Table Load=57 psf for 6'-3" 57 psf> 53.73 psf Thus: 2"Laminated Panel is Satisfactory. iy Engineered Composite Panels , INC A member of the Image Resource Group -7 ) 9 1 SET COVERAGE� 2 Form Cora 2 - CA BACKER 24 CA FACE 2 " POLYSTYRENE CORE — STEEL LAMINATED PANEL Drawn BY: RB Checked: Date: 3-23-18 Laminated Panel 3'-9" 2" Foam Core Panel Revised: lark As: Item: Net Cov. Notes: Job No: #5220 Engineering Composite Panels, INC. SHT: 5 OF 5 J DATE: 3-23-18 BY: RB LOAD TABLE (CLEAR SPAN LENGTH"L"IN BENDING) ALLOWABLE SPANS BASED UPON L/180 DEFLECTION LIMIT UNIFORM LOAD ALLOWABLE SPAN "W" (PSF) "L" (FEET) 208.70 307.60 406.91 506.64 556.21 606.03 1. Panels are laminated polystyrene and steel bonded together with structural Adhesives that conform to ICBO approval. 2. Facing Material: 24 GA. Steel Sheet Metal: Core: Polystyrene (EPS), Density= 1.0 pcf. 3. Steel sheets are considered continuously.bonded with an allowance for unsupported edges. 4. Table shall be used in conjunction with the applicable requirements and load combinations as specified in the International Building Code.