HomeMy WebLinkAboutREVISION FOR PRODUCT APPROVAL C 0.011- Py
OFFICE USE ONLY:
DATE FILED: 14-V23. �k PERAUT# SLCO1704-0135
REVISION FEE: 44;0 SCAMW RECEIPT# I ?-,-7 7,2
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION RECEIVED
——
2111 VIRGINIA AVENUE
/00" FORT PIERCE,FL 34982-5652 P
(772)462-1553 APR 2 3 2018
2
ST. Lucie County, Permitting
C UP APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE THESE PLANS AND ALL PROPOSED WORK
ADDRESS:
ARE SUBJECT TO AW CORRECTIONS
260 SE Prima Vista Blvd(SW corner SW Prima Vista Blvd and Floresta Drive)
:REQUIRED BY FIELD WSPECM HAT'
WIRT,OResb N.ORDED T01.
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
P10ao,C,t&x,0,d, —A,6 (zCejfC,1 1411-7
CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: CGC061217 ST. LUCIE CO CERT.#:
BUSINESS NAME: Hooks Construction Co
QUALIFIERS NAME: Steven C.Hooks
ADDRESS: 2211 S.Kanner Highway
CITY: Stuart STATE: FL ZIP: 34994
PHONE(DAYTIME): 772-419-8828 FAX: 772-237-3757
OWNER/BUILDER INFORMATION:
NAME: Wawa Florida LLC
ADDRESS:7022 TPC Drive,Suite 200
CITY: Orlando STATE: FL ZIP: 32822
PHONE(DAYTIME: 610-358-8000 FAX:
ARCIHTECT/ENGINEER INFORMATION:
NAME: Cuhaci&Peterson
ADDRESS: 1925 Prospect Avenue
CITY: Orlando STATE: FL ZIP: 32814
PHONE(DAYTIME)- 407-661-9100
FAX: 407-661-9101
SLCCC.- 9123109
Revised 06130117
MIAMI-DARE -,viewed; ❑Furnish as Corrected
No Comments �TSLINTY
AeJec� RDT E TION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) J 1805 SW 26 Street,Roo208
BOARD AND CODE ADMINISTRATION DIVISION This rTh Submit Speeiifiicy�to�iami Florida 3317 -2474
-vwwith the" U$b Tl tT�eBpf. 8J,Y -2599
NOTICE OF ACCEPTANCE OA general complia giWaflAdgt]'a p*1eqp 10my
given in the Con Fact ocuments.Corrections
or comments rnade on the shop drawings
Petersen Aluminum Corporation during the review do not relieve contractor
102 Northpoint Parkway,Bldg. 106 from compliance with the requirements of
the plans and s(x,�cifications. Approval or a
RECEIVED specific item shall not include approval of an
Acworth, GA.30120 assembly of which the item is a component.
Contractor is reslxmsible for: dimensions w
SCOPE: APR 2 3 2018 be confirmed and correlated at the Jobsitc;
information that pertains solely to the
This NOA is being issued under the applicable e§T4_q&-g$Vatton o term f d(ff #` n e
documentation submitted has been reviewed and Re-ProdFlc*Gontroll�tioa o be
used in Miami Dade County and other areas where allowed b the Authori H e rk.with that •)r des; and for
Y ty ,,,that
satisiltctory
manner.
This NOA shall not be valid after the expiration date stated below.The Miami- fib 1?i ad,n
(In Miami Dade County)and/or the AM(in areas other than Miami Dade Co t duct
or material tested for quality assurance purposes.If this product or material fail the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,mo fy, or suspend use
of such product or material within their jurisdiction. RER reserves the right to revoke this ac tance,if*
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Snap Clad .032" (min.)x 16" and 18" Wide Aluminum Panel over Wood Deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
YERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
-this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
• shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA 16-1107.09 and consists of pages 1 through 5.
The submitted documentation was reviewed by Freddy Semino
MIAM4DADE COUNTY
NOA No.: 17-1002.12
N, Expiration Date: 03/13/24
Approval Date: 11/09/17
Page 1 of 5
V
ROOFING SYSTEM APPROVAL:
Category: Roofing
Sub-Category: Metal,Panels(Non-Structural)
Material: Alumina
Deck Type: Wood
Maximum Design Pressure: -153.5 ps
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specifications Description
Snap-Clad.032"x Length:various TAS 110 Corrosion resistant preformed standing seam,
18"Wide Aluminum Height: I %" coated,pre-finished aluminum panels.
Panel Width: 16"& 18
Thickness 0.032"
Min.Yield Strength: 26 ksi.
Individual Clip Length: 3.5" TAS 110 20 ga. galvanized steel clip with 2 holes,or
Height: 1.875" 20 ga. stainless steel clip with 2 holes.
Width: 1.982"
Thickness:20 ga.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Valspar 433X515 ASTM B 117 11/21/11
Valspar 433B173 ASTM D 4587,ASTM.G 23 11/21/11
Architectural Testing 73784.01-109-18 TAS-100 08/10/07
D0841.01-450-18-r2 TAS-125 10/03/16
MIAMI•DADE COUNTY NOA No.: 17-1002.12
p Expiration Date:03/13/24
Approval Date: 11/09/17
Page 2 of 5
'i
1 ,
APPROVED ASSEMBLIES:
System: Snap-Clad.032"x 16"or 18" Wide Aluminum Panel
Deck Type: Wood,Non-insulated
Deck Description: New Construction 19/32"or greater plywood or wood plank,or for re-roofing 15/32"or
greater plywood.
Slope Range: 2":12"or greater
Maximum Uplift See Table A Below
Pressure:
Deck-Al acliment: accordance-with appkcable'BUilding Code,but�imnotcase shallst€belless than 2"
w ant nail— s s aced- o o In reroofing,where the deck is less than 19/32"thick
mimum"/32")The above attachment method must be in addition to existing attachment.
Underlayment: Minimum Underlayment shall be an ASTM D 226 Type H installed with a minimum 4"
side-lap and 6"end-laps.Underlayment shall be fastened with corrosion resistant tin-caps
and 12 gauge 1 114"annular ring-shank nails,spaced 6"o.c. at all laps and two staggered
rows 12"o.c.in the field of the roll. Or,any approved Underlayment having a current
NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation# 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with the current published installation instructions and details in PAC Contractors
Association's Roofing Installation Manual.
Metal Panels and Install the" Snap-Clad.032"x 18"Wide Aluminum Panel"panels including flashing
Accessories: penetrations,valleys,end laps and accessories in compliance PAC Contractors
Association's current,published installation instructions and in compliance with the
minimum requirements detailed in Roofing Application Standard RAS 133.
Panels shall be installed along the rib with SNAP CLAD Clips secured with#10 x 1.5"
pancake head screws(2 per clip);the screws shall be of sufficient length to penetrate
through the sheathing a minimum of 3/16".The female rib of panel is snapped over the male
rib of panel.Panel clips shall be spaced a maximum distance listed below in Table A.
TABLE A
_MAXMUM-DESIGN-PRESSURkS
Roof Areas Field Perimeter and Corner'
Maximum Design Pressures -86 psf. -153.5 nef.
Clip Type Individual Individual
Maximum Clip Spacing 24"o.c. 6"O.C.
1.Extrapolation shall not be allowed
MIAMI•DADE COUNTY NOA No.: 17-1002.12
Expiration Date: 03/13/24
Approval Date: 11/09/17
Page 3 of 5
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e. field,perimeters,
and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e.perimeters,extended corners and corners).
3. Panels may be roll formed in continuous lengths from eave to ridge.Maximum lengths shall be as described in
Roofing Application Standard RAS 133. ,
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city, state, and the following
statement: "Miami-Dade County Product Control Approved" or with the Miami-Dade County Product Control
Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or
model.
CMIAMI-D�ADECQUMNTY
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
6. Panels may be shop or jobsite roll formed with machine models#10110884,E00578860,or 01110072 from
PAC Contractors Association or manufactured at Petersen Aluminum Corporation's plant in Acworth,GA.
MIAMI•DADE COUNTY
NOA No.: 17-1002.12
• Expiration Date: 03/13/24
Approval Date: 11/09/17
Page 4 of 5
4 •
PROFILE DRAWINGS
16" or 18"
1-3/4"
1-5/8"
Optional factory Stiffening ribs and
or field applied striations optional.
sealant bead
1.875"
o
3.5" 1.982"
CLIP
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
NOA No.: 17-1002.12
mmTsymp Expiration Date: 03/13/24
Approval Date: 11/09/17
Page 5 of 5
MIAMI•DiADE evicwed, ❑Furnish as Corrected
0
No Comments Revise and -DADE COUNTY
❑Rejected PRODUCT CO TROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) •11805 SW 6 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION ❑Submit Specific Item
This review is only for general conformance Florida 33175-2474
with the design concept of W7§Qj8Jt,5,M9 F(786)315-2599
NOTICE OF ACCEPTANCE O_ A general compliance with th adie. ov/econom
given in the Gntract Documen
LR
or rn en rn e ,
Petersen Aluminum Corporation during the review do not relieve
requi contractor
of
from compliance with the requirements of
102 Northpoint Parkway the plans and specifications. Approval of a
2 3 2018 specific item shall not include approval of an
Acworth,Georgia 30102 assembly of which the item is a component.
Permltting Contractor is responsible for: dimensions to
SCOPE: County, be confirmed and correlated at the jobsite;
information that pertains solely to the
This NOA is beingissued under the applicable rules and regulations fabrication rocesses. r to the eons,
PP � oM�1�t,F�,9�c,�Sl�as�o�t, terials.The
documentation submitted has been reviewed and accepted by Miami- w, a ���- `r 1 Section to be
used in Miami Dade County and other areas where allowed by the A iIattaikTtmiO> �s
manner.
This NOA shall not be valid after the expiration date stated below.T1. RNVA PMMM trol Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami V0 a this product
or material tested for quality assurance purposes.If this product or d manner,the
• manufacturer will incur the expense of such testing and the AHJ may immediately r oke,�acceptance,
spend the use
of such product or material within their jurisdiction. RER reserves the righttorev f it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Snap Clad.032"(min.)x 16"and 18" Wide Aluminum Panel over Wood Deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
-materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#14-0129.08 and consists of pages 1 through 5.
The submitted documentation was reviewed by Hamley Pacheco,P.E.
MIAMI•DADE COUNTY
NOA No.: 16-1107.09
• Expiration Date: 03/13/19
Approval Date: 01/19/17
Page 1 of 5
i
ROOFING SYSTEM APPROVAL:
Cateeorw Roofing
Sub-Cateeorv: Metal,Panels(Non-Structural)
Material: Aluminum
Deck Type: Wood
Maximum Design Pressure: -153.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specifications Description
Snap-Clad.032"x Length:various TAS 110 Corrosion resistant preformed standing seam,
.18"Wide Aluminum Height: 13/4" coated,pre-finished aluminum panels.
Panel Width: 16"& 18"
Thickness 0.032"
Min.Yield Strength:26 ksi
Individual Clip Length:3.5" TAS 110 20 ga.galvanized steel clip with 2 holes,or
Height: 1.875" 20 ga..stainless steel clip with 2 holes.
Width: 1.982"
Thickness:20 ga
EVIDENCE SUBNIITTED:
Test Agencv Test Identifier Test Name/Report Date
Valspar 433X515 ASTM B 117 11/21/11
Valspar 433B173 ASTM D 4587,ASTM G 23 11/21/11
Architectural Testing 73784.01-109-18 TAS-100 08/10/07
D0841.01-450-18-r2 TAS-125 10/03/16
MIAMI•DADE COUNTY
NOA No.:16-1107.09
•••, Expiration Date:03/13/19
Approval Date: 01/19/17
Page 2 of 5
I
APPROVED ASSEMBLIES:
System: Snap-Clad.032"x 16"or 18" Wide Aluminum Panel
Deck Type: Wood,Non-insulated
Deck Description: New Construction"132"or greater plywood or wood plank,or for re-roofing 15/32"or
greater plywood.
Slope Range: 2":12"or greater
Maximum Uplift See Table A Below
Pressure:
eck A_ttacli em nt: accordance wit l ccable Building Code,-but-in-no-case-shall-it-be less.than 8d x 2"
g shank`nail'ssp ed°6 o.c._Inereroofing,where the deck is less than 19/32"thick
(Minimum is/32")The above attachment method must be in addition to existing attachment.
Underlayment: Minimum Underlayment shall be an ASTM D 226 Type II installed with a minimum 4"
side-lap and 6"end-laps.Underlayment shall be fastened with corrosion resistant tin-caps
and 12 gauge 1 '/a"annular ring-shank nails,spaced 6"o.c. at all laps and two staggered
rows 12"o.c.in the field of the roll.Or,any approved Underlayment having a current
NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation# 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with the current published installation instructions and details in PAC Contractors
Association's Roofing Installation Manual.
Metal Panels and Install the" Snap-Clad.032"x 18"Wide Aluminum Panel"panels including flashing
Accessories: penetrations,valleys,end laps and accessories in compliance PAC Contractors
Association's current,published installation instructions and in compliance with the
minimum requirements detailed in Roofing Application Standard RAS 133.
Panels shall be installed along the rib with SNAP CLAD Clips secured with#10 x 1.5"
pancake head screws(2 per clip);the screws shall be of sufficient length to penetrate
through the sheathing a minimum of 3/16".The female rib of panel is snapped over the male
rib of panel.Panel clips shall be spaced a maximum distance listed below in Table A.
TABLE�A
! ` DESIGN PRESSURESS
Roof Areas Field jer•><meter aft _ •oi=uer
Maximum Design Pressures -86 sE -153.5 psf
Cli T e Individual Individual
Maximum Clip Spacing
1.Extrapolation shall not be allowed
MIAMI•DADE COUNTY
NOA No.: 16-1107.09
• Expiration Date: 03/13/19
Approval Date: 01/19/17
Page 3 of 5
LIMITATIONS
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e. field,perimeters,
and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones(i.e.perimeters,extended comers and comers).
3. Panels may be roll formed in continuous lengths from eave to ridge.Maximum lengths shall be as described in
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city, state, and the following
statement: "Miami-Dade County Product Control Approved" or with the Miami-Dade County Product Control '
Seal as seen below. All clips shall be ;permanently labeled with the manufacturer's name and/or logo, and/or
model.
MIAMI•DADE COUNTY
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
6. Panels may be shop or jobsite roll formed with machine model#10110884,E00578960 or 01110072 from PAC
Contractors Association.
NOA No.:1&1107.09
MIAMFDAD;COUNTY Expiration Date:03/13/19
Approval Date:01/19/17
i
Page 4 of 5
PROFILE DRAWINGS
16"or 18"
1-3/4"
Optional factory Stiffening ribs and
or field applied striations optional.
sealant bead
1.875"
0
3.5 1.982"
CLO
END OF THIS ACCEPTANCE
MIAMI-DADE COUNTYNOA No.: 16-1107.09
Expiration Date: 03/13/19
Approval Date: 01/19/17