HomeMy WebLinkAboutENGINEERINGGeneral Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH (5/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING+/- 1%- ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A NIINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE OF TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8", 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS T-0" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN' OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN' OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. THE FLORIDA B UILDING CODE 6th EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. VXTWO.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4" 0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #10X 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: I. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAa i u BE ASTM A 325, PLATED WITH STANDARD ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED FLAT WASHERS AND NUTS. HOME. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING EQUAL. BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE 6th SCANIVIED 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE EDITION R 4501.17IN ITS ENTIRETY. HOT DIPPED GALVANIZED. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY BY 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X CONTRACTOR. 00 r 0ME BOLT DIAMETER INTO STRUCTURAL FRAMMI FRAMING (G=.42 N.). 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL to U ` 1 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT ENSURE BONDING AGENT IS USED FIRST. GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF 5. SCREENING MATERIAL SHALL BE 18X14X0.013 OR THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED INSERTED IN PILOT HOLES BY TURNING AND UNDER NO ON DRAWING S-2. CIRCUMSTANCES BY DRIVING WITH A HAMMER. 6. PLEASE NOTE: 2x2 (typ) DIAGONAL BRACING SHALL BE 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN 2"X2"X0.055" MATERIAL, UNLESS OTHERWISE NOTED ON S-2. ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S 7. ALL ALUMINUM SCREENED ENCLOSURES SHALL BE DESIGNED REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO SPECIFICALLY FOR THE APPLICATION STATED IN RULE 61G20-1-002• TO REMOVE SCREEN PANELS IN THE EVENT OF RECEIVED ENC A L ®� �\GENSF° ° ° ° fro.70667 c ° o STATE OFF O� A, ;,C, O R 11D °°u °°°°°° �o®�d� o 0 OVA L Ee®® ;SIOIAENGINEER SEAL IEER OF RECORD: MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE FORECAST WINDS THAT EXCEED 75 MPH. LABELS SHALL BE David W. Smith P.E. GRADE #5 OR BETTER ZINC PLATED. PLACED ON CHAIR RAIL MEMBERS ON ALL SCREEN WALLS IN U N p 20118 FLORIDA LICENSE: 53608 S. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR A LOCATION THAT CAN BE EASILY SEEN AND FOR ALL PANELS PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 ABOVE THE DESIGNED CHAIR RAIL ON ALL SCREEN WALLS Thomas L. Hanson P. 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES SHALL BE CUT AS PRESCRIBED IN THE RULE AND THE ST. Lucie County, Permitting FLORIDA LICENSE: 38654 FOR USE WITH ACQ PRESSURE TREATED WOOD, OR CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS OTHERWISE NOTED ON PLANS. STATED IN RULE 61G20-1.002 AND SECTION 19 LAWS OF Mark R. Dunn P.E. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. FLORIDA, 553.76, 553.77., ONLY APPLIES IF SHOWN ON PAGE FLORIDA LICENSE: 73968 10. ALL CONNECTORS SHALT, COMPLY WITH ASTM A653 S-2 DRAWING PAGE CLASS G-185. Joel Falardeau P.E. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING DESIGN DATA: FLORIDA LICENSE: 70667 SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" 1, ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): 150 MPH UNLESS NOTED OTHER WISE. I NOMINAL DESIGN WIND SPEED V d 116 MPH $ ik S P E E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 6th EDITION (CHAPTERS 16, 20 & 23). F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP --TYPICAL 2. SIM -- SIMILAR 3. UON -- UNLESS OTHERWISE NOTED 4. CONT -- CONTINUOUS 5. VIF -- VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS,, TIF NOYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. IL MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO a. 2. RISK CATEGORY: 1 3. WIND EXPOSURE: B 4. WIND LOADS: SCREEN ROOF: N/A SCREEN WALLS: 31 PSF SOLID ROOF (SCREEN WALL): 25 PSF COMPONENTS AND CLADDING LOAD: +16.0/-33.5 PSF 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 300 Ib. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS, 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 8. EXISTING 8"X8" THICKENED EDGE WITH 4" MONOLITHIC SLAB SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: N/A 10. SOLID ROOF TYPE: 3"X48"X0.030" ELITE EPS FOAM CORE COMPOSITE PANEL ROOF 11b - - FOAM DENSITY, FLORIDA PRODUCT APPROVAL, FL 7561-R4. ALUMINUM STRUCTURAL MEMBERS 'HOLLOW SECTIONS 2 x 2:---------------------------------------2" x 2" x 0.044„ 2 x 3:-------;-------------------------------2" x 3" x 0.050„ 2 x 4: ------ '=--------- -------------------2" x 4" x 0.050„ 2 x 5: ------=-------------------------------2" x 5" x 0.050" OPEN BACK SECTIONS 1 x 2: ---------------------------------------- 1" x 2" x 0.040„ 1 x 3:----------------------------------------1" x 3" x 0.045„ SNAP SECTIONS 2 x 2 Snap: ---------------------------------- 2" x 2" x 0.045„ 2 x 3 Snap:---------------------------------2" x 3" x 0.050" 2 x 4 Snap:--------------------------------- 2" x 4" x 0.045" SELF MATING (SMB 2 x 4 SMB:---------------------- 2" x 4" x 0.044" x 0.100" 2 x 5 SMB:---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:---------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:--;------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:--=------------------- 2" x 8" x 0.072" x 0.224" 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB:------------------- 2" x 10" x 0.092" x 0.374" /�c oaoz FILE COPY ri tuart . . FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb @ fbcplans.co 1n Webs ite-www. fbcplans. com C.O.A.-#29054 DATE: 6-1-2018 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 PROJECT ADDRESS: COMTOI$ 1325 BENNETT RD FT PIERCE, FL 34947 CONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES S-1 �® o-7 THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC DOOR LOCATION MAY BE DECIDED IN THE FIELD BY CONTRACTOR �, 22'-0„ r7 M N X 0 00 N X X 2X2 t N N 2X2 O I S-3 —3 H (tYP) V 61- 3 S-3 3X3X.125 m2X3SMB O Z X W r � N a N Z ' N X N _ 1X2 2X6SMB EDGE BEAM N N X to M S-4 \PROPOSED 30"x30"x24" W/ (1) #5 REBAR EA. WAY THRU POST ISOLATED FOOTING A L q 44®® ® �, °°°°°°°°° 40 00 �'�C E NSA % oo o® °�o o � a ° No. 7066-e m G o�® ° ®� oo STATE OF o 0 4 R 1D P O °°°°°°°°°°. NA P O STf ON ��E 6�®�i19i6�d,� S L NGINEER SEAL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fl)cplans.com Website-wW W. fbcplans.com C.O.A.429054 DATE: 6-1-2018 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3- - - RO 4 PROJECT ADDRESS: COMTOI$ 1325 BENNETT RD FT PIERCE, FL 34947 ,ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 FLOOR PLAN S-2 THIS SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, ALUMINUM RISER PAN (4) #10 SMS W/ 3/4" WASHERS PER 12" PANEL #10X4"SMS Detail C2 f4" NEOPRENE ER 8" O.C.PER PANEL 3"SOLID I --ROOF PANEL 3"SOLID ROOFPANEL �2"X2"X3"X0. ANGLE W/ (2) #12X ----------- EDGE BEAM7 L: I II 3/4"EA. LEG SLICE I I I #10X4" SMS THRU 1" X2"OPEN BACK ADDED TO EDGE BEAM w/(2) #10 x1 �/y"SMS &TO EDGE I II ,BEAM II II SMS 12" C/C IF TRIBUTARY BETWEEN POST I I I I EXCEEDS6'-6"OR II II 150 MPII "C" II II SIDE VIEW 2"X_'10.050" EDGE BEAM I III PO T SCREW BOSS CONTINUOUS (SEE S-2 FOR SIZE) EDGE BEAM SPLICE 1) # 1OX 4" -MIN. ----- ------------ VTOSCREWBOSS - -------- -------- 2"X_"10.050"UPRIGHT (SEE S-2 FOR SIZE) _ 2"X2"X3"X 0.62" (4) #10X4" SMS THRU I I ANGLE W/ (2) #12X EDGE BEAM INTO 3/4" EA. LEG POST SCREW BOSS EDGE BEAM SPLICE S ROOF PANEL TO EDGE BEAM CONNECTION DETAIS S-3 SCALE:NTS OPTION #1 - - (4)#10.x-1Y,"SMS INTO SCREW BOSSES OPTION #2 RECEIVING CHANNEL ,--OR ANGLE EA, SIDE (typ)' (.0625" THICKNESS) 2"X2" OR 2"13" (2) #10x 3/4" SMS PURLIN OR GIRT (typ) EA. LEG) (TOTAL 6 SCREWS R.C. (8) SCREWS ANGLE EA. CONNECTION) H PURLIN OR GIRT TO BEAM OR POST DETAIL S-3 SCALE:NTS (4) #10 X 3/4" SMS UPRIGHT FASTENING SECONDARY SECONDARY ANGLE ANGLE TO COLUMN (TYP (MIN 0.125" THICK) EACH SIDE) PRIMARY 2" X 2" X 0.125" ANGLE (B) -3/8" 0 CONCRETE SCREW I (2) #10 X 3/4" SMS FASTENING ANCHOR INTO SECONDARY I COLUMNTOPRIMARY ANGLE ANGLE(TYP EACH SIDE) (SEE O UYP EACH SIDE) TABLE) O O 1" X 2" BASE MEMBER (TYP EACH SIDE) ANCHORSPA (MIN) (TYP)(SEE TABLE) (1) - 3/8" 0 CONCRETE SCREW ANCHOR INTO PRIMARY Column Size 3/8" 0 Concrete Screw Anchor B Min. Spa 264 2x5 1 3 2x6 4 2x7 2x8 1 6 2x9 2 4 2xl0 2 4.5 ANGLE AND @ 1/4" 0 CONCRETE 3" (MIN) SCREW ANCHOR @ 24" O.C. BETWEEN COLUMNS NOTES: (TYP EACH SIDE) 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1)(2. 2, MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-1/2" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT, 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON ITW RED HEAD83/8" 0 LARGE DIAMETER TAPCONS WITH AN ULTIMATE TENSION CAPACITY OF 3740 LBS, AND AN ULTIMATE SHEAR CAPACITY OF 3328 LBS. STAINLESS STEEL CONCRETE SCREW ANCHORS (3/8" 0) WITH MINIMUM ULTIMATE TENSION AND SHEAR CAPACITIES LISTED ABOVE MAY BE USED IN THE SAME QUANTITY AS THE TABLE. OTHER SIZE OR TYPE OF ANCHORS REQUIRE SITE -SPECIFIC ENGINEERING. G 2" x 4" OR LARGER UPRIGHT TO CONCRETE W WO PAVER DETAILS S-3 SCALE:NTS HINGE LOCATION 2" x 2" EXTRUSION 2" x 2" EXTRUSION HINGE LOCATION - _ . DOOR ­ HINGE LOCA NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 x 5/8" SMS MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2) HINGES MINIMUM. 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS. FASTEN A 1" x 2" x 0.044" TO UPRIGHT W/# 12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. F TYPICAL SCREEN DOOR CONNECTION DETAIL S-l� SCALE:NTS 2" x_" MEMBER (SEE SHEET S-2 FOR SIZE) EXISTING MASOI WALL GROUTED SOLID OR WOOD @ CONNECTION EAVE MEMBER ATTACHED TO 1"X2" OPEN BACK W/ (4) #10X2" SMS THRU SCREW BOSSES (typ) 1"X2"10.045" OPEN BACK ATTACHED TO HOST W/ 1/4" 0 X 2-3/4" EMBEDMENT MASONRY SCREW 3" FROM END &@ 24" O.C. OF WOOD USE IDENTICAL SIZE LAG) SZ END BEAM TO HOST STRUCTURE DETAIL S-3 SCALE:NTS HOSTSTRUCTURE BREAK FORM HEADER OR RECEIVING CHANNEL #10 SMS AT EACH RISER —FOR PAN OR #10 SMS @ 8" O.C. FOR COMPOSITE PANEL �QD F A O o ° w OF �O 70647 %7 o c w m _)3 a STATE o ° o 0 A\ 1 0 R 10 P ®�0 0s, SS � ® °o ®® V®BONA L o�aBan P FESSIONA�et�1GINEER SEAL ENGINI?ER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson RE FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www. fbcplans.com C.O.A.-#29054 DATE: 6-1-2018 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 IOLID ROOF RO 3 I IR04 PROJECT ADDRESS: COMTOI$ #10 SMS @ 8" O.C. 1325 BENNETT RD (MIN) FOR COMPOSITE PANEL 7 FT PIERCE, FL 34947 (2) #10 SCREWS PER 12" WIDTH CONNECTING PANTO HEADER (BOTTOM CONTRACTOR: OR BACK OF PAN) (2) #10 X 2" SCREWS PER 12" WIDTH CONNECTING K & S INDUSTRIES, INC. HEADER OR CHANNEL TO FASCIA. 1379 SVV BILTMORE ST. S1 ROOF PANEL TO FASCIA CONNECTION DETAILS PORT ST LUCIE, FL 34983 S-3 SCALE:NTS DETAILS S-3 THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC #10 SMS W/ 1"0 NEO-WASHERS c@ 8" O.C. (USE SCREW LENGTH EQUAL TO COMPOSITE PANEL THICKNESS PLUS (1) INCH) SEE DETAIL C2 FOR ALUMINUM RISER PANS—\ POST ALUMINUM RISER PAN (4) #10 SMS W/ 3/4" WASHERS PER 12" PANEL ItTy Detail C2 (4) 3/8"0 MACHINE BOLTS WITH 3/4" WASHERS EACH SIDE (NOTE: IF 2X4 THRU 2X7 SMB REDUCE THRU BOLTS BY (1) 3/8"0 MACHINE BOLT) BEAM NOTCH POST FOR BEAM S4 ROOF PANEL TO EDGE BEAM CONNECTION DETAIL S_tI SCALE: NTS GRADE • • (1)#5 OR (2) #4 REBAR CONTINUOUS W/ 25" OVERLAP AT ALL JOINTS ON I2' 3" CHAIRS& 3" EDGE DISTANCE 12"x12" RIBBON FOOTING NOTES FOR ALL FOUNDATION TYPES: 1. THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL BEARING PRESSURE OF 1,500 PSF. THE BEARING CAPACITY OF THE SOIL VERIFIED BY A LICENSED CONTRACTOR PRIOR TO ANY POURING OF CONCRETE. 2. THE SLAB/FOUNDATION MUST BE CLEARED OF ALL DEBRIS, AND COMPACTED PRIOR TO POURING OF ANY CONCRETE. 3. CONCRETE MEET THE SPECIFICATIONS IN THE S-1 NOTES PAGE. K TYPE If MONOLITHIC SLAB FOOTING S-4 ' ' ' ' V12"OPEN BACK (IF REQUIRED) ATTACHED TO HOST W/ (1)1/4"0 CONCRETE SCREW OR LAG WITHIN 6" OF BEAM & @ a 24" O.C. MAX BETWEEN N BEAMS a O (B) -1/4" 0 CONCRETE SCREW W/ Ln 1-1/2" EMBEDMENT INTO MASONRY (1-1/2" MIN. SPACING OR (B)-1/4" 0 X 2" LAG SCREWS INTO WOOD (1" MIN SPACING) (TYP 2 LOCATIONS) BEAM "B" NOTES: 2X4 1 1. THE MINIMUM EDGE DISTANC IS 3" FOR MASONRY 2x5 2 STRUCTURES. 2, IF A RECEIVING CHANNEL IS 2x6 2 USED, USE TWICE THE NUMBER 2x7 3 "B" ANCHORS INTO THE HOST STRUCTURE. ALL MINIMUM 2x8 3 SPACING SHALL BE APPLICABLE, 2x9 3 2x10 4 S3 BEAM TO HOST 1 GALA ^^e T 000—0000, J� o\C ENS"°, 01 ® o No. 70667 G ° o ° L3 0 a % STATE OF °o ° ®®O�°OR I900 \\ °OOO000°°° 0;40 ®ON B Il d 4 ®00 P*Fp /INEER SEAL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLAT RIDGE & FLORIDA LICENSE: 38654 ROOF BEAMS (SEE Mark R. Dunn P.E. SHEET S-2 FOR SIZE) FLORIDA LICENSE: 73968 \_2"X2"X0.125"ANGLE Joel Falardeau P.E. EA, SIDE OF BEAM LORIDA LICENSE: 70667 EXISTING HOST STRUCTURE Erik Stuart P.E. -(CONCRETE, GROUT FILLED FLORIDA LICENSE: 77605 CMU ORWOOD) FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 'TION DETAIL Ph# (813)788-5314 Fax# 1-(E166)824-7894 E-mail-erb@ibcplans,co m Website-Www.fbcplans.com C.O.A.-#29054 POST 12" 4 'VARIES" (1) - 12" LONG 3/8" ° 4. "VARIES", DIA. BAR c THROUGH COLUMN__ (EACH WAY) n a dQ 4* "All (EACH DIRECTION) NOTE: IF TOP MOUNT REFER TO DETAIL G2, SA TYPICAL ISOLATED FOOTING SECTION DETAIL SCALE: N.T.S. DATE: 6-1-2018 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3- RO 4 PROJECT ADDRESS: COMTOIS 1325 BENNETT RD FT PIEROE, FL 34947 :ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-4 THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WTHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC