Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE 6-27-18?I0) SCANNEU FORMR405-2017 By �- 4 FLORIDA ENEAVPWOMVENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE MANOR Builder Name: WYNNE BUILDING CORP. Street: THE MANOR \ Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE; FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce ! ��� i County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1654.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1374.20 ft2 I 3. Number b. Frame - Wood, Adjacent R=11.0 280.00 ft2 of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1644.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1644.00 ft2 6. Conditioned floor area above grade (ft2) 1644 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(153.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 225 a. U-Factor: Dbl, U=0.63 113.35 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: NIA ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.010 ft. Area Weighted Average SHGC: ' 0.240 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1643.5 sqft.) Insulation ,Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1643.50 ft2, b. Conservation features b. NIA R= ft2 None c. N/A R= ft2 i 15. Credits Pstat Total Proposed Modified Loads: 52.90 Glass/Floor Area: 0.093 PASS Total Baseline Loads: 52.98 I hereby certify that the plans and specifications covered by Review of the plans and ST,q?� this calculation are in compliance with the Florida Energy specifications covered by this O�T$E �y ,� _ 0 Code. calculation indicates compliance �O @TPf �n C& with the Florida Energy Code. rrr, s.-. •.; ;;.",� PREPA ED Y: DATE: `� Before construction is completed this building will be inspected for compliance with Section 553.908 0-1�•��; �., ;d * „ I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. COD with WE OWNER F.�IT - BUILDING OFFICIAL: DATE: .t DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no'greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 6/22/2018 11:06 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT 5UMMAKY GHIzUKLI5I KEPUK PROJECT Title: WYNNE THE MANOR Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1644 Lot # Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 225 Street: THE MANOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1644 14134.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 GREAT ROOM 546 5350.8 No 0 1 Yes Yes Yes 2 MASTER BEDROO 274 2192 No 2 1 1 Yes Yes Yes 3 WIC 77 616 No 0 1 No Yes Yes 4 CLST. 35 280 No 0 1 No Yes Yes 5 M BATH 54 432 No 0 1 Yes Yes. Yes 6 KITCHEN 180 1440 Yes 0 1 Yes Yes Yes 7 JUNIOR M. BED 198 1584 No 0 1 1 Yes Yes Yes 8 BATH 50 400 No 0 1 No Yes Yes 9 POWDER 35 280 No 0 1 Yes Yes Yes 10 NOOK 42 336 No 0 1 Yes Yes Yes 11 LAUNDRY 49 392 No 0 1 Yes Yes Yes 12 ENTRY 104 832 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio GREAT ROOM 47 ft 0 546 ftz ---- 0 1 0 2 Slab -On -Grade Edge Insulatio MASTER BEDRO 46 ft 0 274 ftZ ---- 0 1 0 3 Slab -On -Grade Edge Insulatio WIC 1 ft 0 77 ftZ ---- 0 1 0 4SIab-On-Grade Edge Insulatio CLST. 1 ft 0 35 ftz ---- 0 1 0 5 Slab -On -Grade Edge Insulatio M BATH 9 ft 0 54 ftZ _--- 0 1 0 6/22/2018 11:06 AM EnergyGaugeg) USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHLUKLI5T KEPUK I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 180 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio JUNIOR M. BED 14 ft 0 198 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio BATH 1 ft 0 50 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio POWDER 5 ft 0 35 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio NOOK E ft 0 42 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulatio LAUNDRY 17 ft 0 49 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio ENTRY 5.9 ft 0 103.5 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1733 ft2 0 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1644 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) GREAT ROOM 30 Blown 546 ft2 0.1 Wood 2 Under Attic (Vented) MASTER BEDRO 30 Blown 274 ft2 0.1 Wood 3 Under Attic (Vented) WIC 30 Blown 77 ft2 0.1 Wood 4 Under Attic (Vented) CLST. 30 Blown 35 ft2 0.1 Wood 5 Under Attic (Vented) M BATH 30 Blown 54 ft2 0.1 Wood 6 Under Attic (Vented) KITCHEN 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) JUNIOR M. BED 30 Blown 198 ft2 0.1 Wood 8 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 9 Under Attic (Vented) POWDER 30 Blown 35 ft2 0.1 Wood 10 Under Attic (Vented) NOOK 30 Blown 42 ft2 0.1 Wood 11 Under Attic (Vented) LAUNDRY 30 Blown 49 ft2 0.1 Wood 12 Under Attic (Vented) ENTRY 30 Blown 104 ft2 0.1 Wood WALLS Adjacent lypepace Cavity Width Sall Height Area Sheathing Framing Solar Below 1 SW=>E Exterior Concrete Block - Ext In.GREAT ROO 4.1 26 0 9 10 255.7 ft2 0 0 0.4 0 2 NW=>S Exterior Concrete Block - Ext In37REAT ROO 4.1 21 0 9 10 206.5 ft2 0 0 0.4 0 3 NE=>W Exterior Concrete Block - Ext In9MASTER BE 4.1 25 0 8 0 200.0 ft2 0 0 0.4 0 4 SW=>E Exterior Concrete Block - Ext In9MASTER BE 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 6/22/2018 11:06 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity ity Width Height Sheathing Framing Solar Below We Et In Ft In Area R-Vahle Erantonn Ah 5 NW=>S Exterior Concrete Block - Ext IndVIASTER BE 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 6 NE=>W Exterior Concrete Block - Ext InsulM BATH 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 7 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 8 NE=>W Exterior Concrete Block - Ext Ins1WNIOR M. B 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 9 SW=>E Exterior Concrete Block - Ext InsdPOWDER 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 10 SW=>E Exterior Concrete Block - Ext Insul NOOK 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 NE=>W Exterior Concrete Block - Ext InsdIAUNDRY 4.1 3 0 8 0 24.0 ft2 0 0 0.4 0 12 SE=>N Exterior Concrete Block - Ext InsillAUNDRY 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0 13 SW=>E Exterior Concrete Block - Ext InsUWUNDRY 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0 14 SE=>N Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 15 N=>SW Garage Frame - Wood ENTRY 11 35 8 280.0 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated ENTRY None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW=>E 1 Metal Low-E Double Yes 0.63 0.25 Y 46.4 ft2 1 ft 0 in 1 ft 4 in None None 2 NW=>S 2 Metal Low-E Double Yes 0.65 0.21 Y 40.0 ft2 8 ft 0 in 1 ft 4 in None None 3 NW=>S 5 Metal Low-E Double Yes 0.63 0.25 Y 32.4 ft2 1 ft 0 in 1 ft 4 in None None 4 NE=>W 6 Metal Low-E Double Yes 0.63 0.25 Y 6.9 ft2 1 ft 0 in 1 ft 4 in None None 5 NE=>W 8 Metal Low-E Double Yes 0.63 0.25 Y 16.2 ft2 1 ft 0 in 1 ft 4 in None None 6 SW=>E 9 Metal Low-E Double Yes 0.63 0.25 Y 6.9 ft2 1 ft 0 in 1 ft 4 in None None 7 SE=>N 12 Metal Low-E Double Yes 0.63 0.25 Y 4.7 ft2 7 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 35 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000382 1649.1 90.53 170.26 .2831 7 6/22/2018 11:06 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 6 Fn+RM R4n5-9nl7 INPl1T Sl1MMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / ---- Supply ---- ---- Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 225 ft2 Attic 55 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Venting H Jan Feb Mar Jan H ki Mar Apr M:y Jun Jul MJun rjrl Jul Aug I I Se rl Sep � i Oct Oct Nov ki Nov Dec H Dec Feb ay Jun Aug Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78, 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/22/2018 11:06 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 1 GREAT ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST. Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 JUNIOR M. BED Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 POWDER Default(8 Ibs/sq.ft. ft2 ft 0.3 NOOK Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/s .ft. ft2 ft 0.3 ENTRY Name: Test Rater Signature:Itu Rating Compant: Test Rater Date: lQ ` L" O 6/22/2018 11:06 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 6 of 6 '2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE MANOR Builder Name: WYNNE BUILDING CORP. Street: THE MANOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: WYNNE BUILDING CORP. Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire 12[inkler cover plates and walls or ceilings a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/22/2018 11:07 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 • 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* =100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1644 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.635 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.240 14. Heating system: Capacity 34.8 c) Area 7c. 153.4 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 8.50 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: 71;:� Address of New Home: THE MANOR �� City/FL Zip: L ���� S21 6/22/2018 11:06:49 AM EnergyGauge@ USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1