HomeMy WebLinkAboutENERGY EFFICIENCY CODE 6-27-18?I0)
SCANNEU
FORMR405-2017 By �- 4
FLORIDA ENEAVPWOMVENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE MANOR
Builder Name: WYNNE BUILDING CORP.
Street: THE MANOR \
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE; FL,
Permit Number:
Owner: WYNNE BUILDING CORP.
Jurisdiction:
Design Location: FL, Fort Pierce ! ���
i
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1654.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1374.20 ft2
I
3. Number
b. Frame - Wood, Adjacent
R=11.0 280.00 ft2
of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1644.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1644.00 ft2
6. Conditioned floor area above grade (ft2) 1644
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(153.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 225
a. U-Factor: Dbl, U=0.63 113.35 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.65 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: NIA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.010 ft.
Area Weighted Average SHGC: ' 0.240
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1643.5 sqft.) Insulation ,Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1643.50 ft2,
b. Conservation features
b. NIA R= ft2
None
c. N/A R= ft2
i
15. Credits
Pstat
Total Proposed Modified Loads: 52.90
Glass/Floor Area: 0.093
PASS
Total Baseline Loads: 52.98
I hereby certify that the plans and specifications covered by
Review of the plans and
ST,q?�
this calculation are in compliance with the Florida Energy
specifications covered by this
O�T$E
�y ,� _ 0
Code.
calculation indicates compliance
�O
@TPf �n C&
with the Florida Energy Code.
rrr, s.-. •.; ;;.",�
PREPA ED Y:
DATE: `�
Before construction is completed
this building will be inspected for
compliance with Section 553.908
0-1�•��; �., ;d
* „
I hereby certify that this building, as designed, is in compliance
the Florida Energy Code.
Florida Statutes.
COD
with
WE
OWNER F.�IT -
BUILDING OFFICIAL:
DATE: .t
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no'greater than 7.00 ACH50 (R402.4.1.2).
FILE COPY
6/22/2018 11:06 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT 5UMMAKY GHIzUKLI5I KEPUK
PROJECT
Title: WYNNE THE MANOR
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1644
Lot #
Owner Name: WYNNE BUILDING CORP.
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP.
Rotate Angle: 225
Street:
THE MANOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp
Heating Design Daily Temp
Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1644
14134.8
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 GREAT ROOM 546
5350.8 No
0
1
Yes
Yes
Yes
2 MASTER BEDROO 274
2192 No
2
1
1
Yes
Yes
Yes
3 WIC 77
616 No
0
1
No
Yes
Yes
4 CLST. 35
280 No
0
1
No
Yes
Yes
5 M BATH 54
432 No
0
1
Yes
Yes.
Yes
6 KITCHEN 180
1440 Yes
0
1
Yes
Yes
Yes
7 JUNIOR M. BED 198
1584 No
0
1
1
Yes
Yes
Yes
8 BATH 50
400 No
0
1
No
Yes
Yes
9 POWDER 35
280 No
0
1
Yes
Yes
Yes
10 NOOK 42
336 No
0
1
Yes
Yes
Yes
11 LAUNDRY 49
392 No
0
1
Yes
Yes
Yes
12 ENTRY 104
832 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio GREAT
ROOM 47 ft 0
546 ftz
----
0 1
0
2 Slab -On -Grade Edge Insulatio MASTER
BEDRO 46 ft 0
274 ftZ
----
0 1
0
3 Slab -On -Grade Edge Insulatio WIC
1 ft 0
77 ftZ
----
0 1
0
4SIab-On-Grade Edge Insulatio CLST. 1 ft 0
35 ftz
----
0 1
0
5 Slab -On -Grade Edge Insulatio M BATH 9 ft 0
54 ftZ
_---
0 1
0
6/22/2018 11:06 AM EnergyGaugeg) USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHLUKLI5T KEPUK I
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft
0
180 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio
JUNIOR M. BED 14 ft
0
198 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
BATH 1 ft
0
50 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
POWDER 5 ft
0
35 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
NOOK E ft
0
42 ft2
----
0
1
0
11SIab-On-Grade Edge Insulatio
LAUNDRY 17 ft
0
49 ft2
----
0
1
0
12SIab-On-Grade Edge Insulatio
ENTRY 5.9 ft
0
103.5 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 1733 ft2
0 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
300
1644 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
GREAT ROOM
30
Blown
546 ft2
0.1
Wood
2 Under Attic (Vented)
MASTER BEDRO
30
Blown
274 ft2
0.1
Wood
3 Under Attic (Vented)
WIC
30
Blown
77 ft2
0.1
Wood
4 Under Attic (Vented)
CLST.
30
Blown
35 ft2
0.1
Wood
5 Under Attic (Vented)
M BATH
30
Blown
54 ft2
0.1
Wood
6 Under Attic (Vented)
KITCHEN
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
JUNIOR M. BED
30
Blown
198 ft2
0.1
Wood
8 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
9 Under Attic (Vented)
POWDER
30
Blown
35 ft2
0.1
Wood
10 Under Attic (Vented)
NOOK
30
Blown
42 ft2
0.1
Wood
11 Under Attic (Vented)
LAUNDRY
30
Blown
49 ft2
0.1
Wood
12 Under Attic (Vented)
ENTRY
30
Blown
104 ft2
0.1
Wood
WALLS
Adjacent
lypepace
Cavity Width
Sall
Height
Area
Sheathing Framing
Solar
Below
1 SW=>E Exterior Concrete Block - Ext In.GREAT ROO
4.1 26
0 9
10
255.7 ft2
0
0
0.4
0
2 NW=>S Exterior Concrete Block - Ext In37REAT ROO
4.1 21
0 9
10
206.5 ft2
0
0
0.4
0
3 NE=>W Exterior Concrete Block - Ext In9MASTER BE
4.1 25
0 8
0
200.0 ft2
0
0
0.4
0
4 SW=>E Exterior Concrete Block - Ext In9MASTER BE
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
6/22/2018 11:06 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity ity Width
Height
Sheathing Framing
Solar
Below
We Et In
Ft In
Area
R-Vahle
Erantonn
Ah
5
NW=>S Exterior
Concrete Block - Ext IndVIASTER BE
4.1 13
0
8 0
104.0 ft2
0
0
0.4
0
6
NE=>W Exterior
Concrete Block - Ext InsulM BATH
4.1 9
0
8 0
72.0 ft2
0
0
0.4
0
7
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.4
0
8
NE=>W Exterior
Concrete Block - Ext Ins1WNIOR M. B
4.1 14
0
8 0
112.0 ft2
0
0
0.4
0
9
SW=>E Exterior
Concrete Block - Ext InsdPOWDER
4.1 5
0
8 0
40.0 ft2
0
0
0.4
0
10
SW=>E Exterior
Concrete Block - Ext Insul NOOK
4.1 6
0
8 0
48.0 ft2
0
0
0.4
0
11
NE=>W Exterior
Concrete Block - Ext InsdIAUNDRY
4.1 3
0
8 0
24.0 ft2
0
0
0.4
0
12
SE=>N Exterior
Concrete Block - Ext InsillAUNDRY
4.1 7
0
8 0
56.0 ft2
0
0
0.4
0
13
SW=>E Exterior
Concrete Block - Ext InsUWUNDRY
4.1 7
0
8 0
56.0 ft2
0
0
0.4
0
14
SE=>N Exterior
Concrete Block - Ext Insul ENTRY
4.1 6
0
8 0
48.0 ft2
0
0
0.4
0
15
N=>SW Garage
Frame - Wood ENTRY
11 35
8
280.0 ft2
0.23
0.4
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 SE=>N Insulated ENTRY
None
.39
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
V
Wall
Overhang
# Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 SW=>E 1
Metal Low-E Double Yes
0.63 0.25
Y
46.4 ft2
1 ft 0 in
1 ft 4 in
None
None
2 NW=>S 2
Metal Low-E Double Yes
0.65 0.21
Y
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
3 NW=>S 5
Metal Low-E Double Yes
0.63 0.25
Y
32.4 ft2
1 ft 0 in
1 ft 4 in
None
None
4 NE=>W 6
Metal Low-E Double Yes
0.63 0.25
Y
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NE=>W 8
Metal Low-E Double Yes
0.63 0.25
Y
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
6 SW=>E 9
Metal Low-E Double Yes
0.63 0.25
Y
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
7 SE=>N 12
Metal Low-E Double Yes
0.63 0.25
Y
4.7 ft2
7 ft 0 in
1 ft 4 in
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 440 ft2 440 ft2
35 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000382 1649.1 90.53
170.26
.2831
7
6/22/2018 11:06 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 6
Fn+RM R4n5-9nl7 INPl1T Sl1MMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
None
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr 1044 cfm
0.85
1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
/
---- Supply ----
---- Return --
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6 225 ft2
Attic
55 ftz Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Venting H
Jan Feb Mar
Jan H ki Mar
Apr
M:y Jun Jul
MJun
rjrl Jul
Aug
I I
Se
rl Sep
� i
Oct
Oct
Nov
ki Nov
Dec
H Dec
Feb
ay Jun
Aug
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM 78
78 78
78 78, 78
78
78
80
80
80
80
PM 80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78
78
78
78
78
78
78
PM 78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
6/22/2018 11:06 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
1 GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST.
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
JUNIOR M. BED
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
POWDER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
NOOK
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/s .ft.
ft2
ft
0.3
ENTRY
Name: Test Rater Signature:Itu
Rating Compant: Test Rater Date: lQ ` L" O
6/22/2018 11:06 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 6 of 6
'2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE MANOR Builder Name: WYNNE BUILDING CORP.
Street: THE MANOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: WYNNE BUILDING CORP. Jurisdiction:
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire 12[inkler cover plates and walls or ceilings
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/22/2018 11:07 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
• 2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =100
The lower the Energy
Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1644
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.635
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.240
14. Heating system: Capacity
34.8
c) Area
7c.
153.4
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
8.50
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
71;:�
Address of New Home: THE MANOR �� City/FL Zip: L ���� S21
6/22/2018 11:06:49 AM EnergyGauge@ USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1