HomeMy WebLinkAboutENERGY EFFICIENCY CODE} FORM R405-20,CO VT1 ACTOR
P�
I
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Profess I Regulation - Residential Performance Method
.Project Name: WYNNE THE MANOR n � I
Builder Name: WYNNE BUILDING CORP.
Street: THE MANOR I-'
Permit Office: ST. LUCIE COUNTY
�� •�NN LU
V
City, State, Zip: FT. PIERCE, FL,
Permit Number:
BY
Owner: WYNNE BUILDING CORP.
Design Location: FL, Fort Pierce I
Jurisdiction:
County: St. Lucie (Florida Climatsotop'�ts 'flnflt(/
1. New construction or existing New (From Plans) I
9. Wall Types (1654.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 ' 1374.20 ft2
b. Frame - Wood, Adjacent
R=11.0 280.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1644.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1644.00 ft2
6. Conditioned floor area above grade (ft2) 1644
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(153.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 225
a. U-Factor: Dbl, U=0.63 113.35 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.65 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.010 ft.
Area Weighted Average SHGC: 0.240
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1643.5 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1643.50 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2 i
15. Credits
Pstat
Total Proposed Modified
Loads: 52.90
Glass/Floor Area: 0.093
PASS
Total Baseline
Loads: 52.98
I hereby certify that the plans and specifications covered by
Review of the plans and
EVE S�,q?,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
�� �i,'' _ ' •�'�.�`
with the Florida Energy Code.
tr ,na s..1�.• •h' ,•;,•- „ O
PREP E Y'
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
/ 5�
with the Florida Energy Code.
G'OD WTE
OWNER/ E
BUILDING OFFICIAL:
DATE:
DATE:
I
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.11.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no igreater than 7.00 ACH50 (R402.4.1.2).
6/22/2018 12:04 PM EnergyGaugeB USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLI5T REPORT
PROJECT
Title: WYNNE THE MANOR
Bedrooms:
I
2
Address Type:
Street Address
Building Type: User
Conditioned
rea: 1644
Lot #
Owner Name: WYNNE BUILDING CORP.
Total Stories:
1
Block/Subdivision:
# of Units: 1
Worst.Case:
Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP.
Rotate Angle:
225
Street:
THE MANOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole Housel
Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
I 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1644 14134.81
SPACES
Number Name
Area Volume Kiichen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 GREAT ROOM
546 5350.8 No
0
1
Yes
Yes
Yes
2 MASTER BEDROO
274 2192 No
2
1
1
Yes
Yes
Yes
3 WIC
77 616 No
0
1
No
Yes
Yes
4 CLST.
35 280 INo
0
1
No
Yes
Yes
5 M BATH
54 432 No
0
1
Yes
Yes
Yes
6 KITCHEN
180 1440 Yes
0
1
Yes
Yes
Yes
7 JUNIOR M. BED
198 1584 I No
0
1
1
Yes
Yes
Yes
8 BATH
50 400 No
0
1
No
Yes
Yes
9 POWDER
35 280 No
0
1
Yes
Yes
Yes
10 NOOK
42 336 No
0
1
Yes
Yes
Yes
11 LAUNDRY
49 392 iNo
0
1
Yes
Yes
Yes
12 ENTRY
104 832 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
GREAT ROOM 47 ft 0
546 ftz
----
0 1
0
2 Slab -On -Grade Edge Insulatio
MASTER BEDRO 46 ft 0
274 ftZ
----
0 1
0
3 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
77 ftZ
_---
0 1
0
4 Slab -On -Grade Edge Insulatio
CLST. 1 ft 0
35 ftz
----
0 1
0
5 Slab -On -Grade Edge Insulatio
M BATH 9 ft 0
54 ft2
----
0 1
0
6/22/2018 12:04 PM EnergyGaugeO USA' Section R405.4.1 Compliant Software Page 2 of 6
FORM R4.05-2017 INPUT SUMMARY CHECKLI5T REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft 0
180 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio
JUNIOR M. BED 14 ft 0
198 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
BATH 1 ft 0
I
50 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
POWDER 5 ft 0
35 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
NOOK 6 ft 0
42 ft2
----
0
1
0
11SIab-On-Grade Edge Insulatio
I
LAUNDRY 17 ft 0
49 ft2
----
0
1
0
12SIab-On-Grade Edge Insulatio
ENTRY 5.9 ftI 0
103.5 ft2
_---
0
1
0
ROOF
V
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials
Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 1733 ft2
0 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V # Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented 300
1644 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
GREAT ROOM
30
Blown
546 ft2
0.1
Wood
2 Under Attic (Vented)
MASTER BEDRO
30
Blown
274 ft2
0.1
Wood
3 Under Attic (Vented)
WIC
30
Blown
77 ft2
0.1
Wood
4 Under Attic (Vented)
CLST.
30
Blown
35 ft2
0.1
Wood
5 Under Attic (Vented)
M BATH
30
Blown
54 ft2
0.1
Wood
6 Under Attic (Vented)
KITCHEN
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
JUNIOR M. BED
30
Blown
198 ft2
0.1
Wood
8 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
9 Under Attic (Vented)
POWDER
30
Blown
35 ft2
0.1
Wood
10 Under Attic (Vented)
NOOK
30
Blown
42 ft2
0.1
Wood
11 Under Attic (Vented)
LAUNDRY
30
Blown
49 ft2
0.1
Wood
12 Under Attic (Vented)
ENTRY
30
Blown
104 ft2
0.1
Wood
WALLS
I
Adjacent
()rat TO Wall Type
Space Cavity Width
Height
Sheathing Framing
Solar
Below
0
1 SW=>E Exterior Concrete Block - Ext InIGREAT ROO 4.1 26
0 9
10
255.7 ft2
0
0
0.4
0
2 NW=>S Exterior Concrete Block - Ext InGREAT ROO 4.1 21
0 9
10
206.5 ft2
0
0
0.4
0
3 NE=>W Exterior Concrete Block - Ext IndMASTER BE 4.1 25
0 8
0
200.0 ft2
0
0
0.4
0
4 8W=>E Exterior Concrete Block - Ext InNASTER BE 4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
6/22/2018 12:04 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6
FnRM Rdns_gn17 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
9
()rnt In
Space
Wall Type
le Et In
Ft In
Area
RA/mble
Eractmon Ahqor
Grade%
5
NW=>S Exterior
Concrete Block - Ext IndMWSTER BE 4 j1 13
0
8 0
104.0 ft2
0
0
0.4
0
6
NE=>W Exterior
Concrete Block - Ext InsulM BATH
4:1 9
0
8 0
72.0 ft2
0
0
0.4
0
7
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4A 11
0
8 0
88.0 ft2
0
0
0.4
0
_
8
NE=>W Exterior
Concrete Block - Ext Ina WNIOR M.
B 4i1 14
0
8 0
112.0 ft2
0
0
0.4
0
9
SW=>E Exterior
Concrete Block - Ext InsuIPOWDER
4i1 5
0
8 0
40.0 ft2
0
0
0.4
0
10
SW=>E Exterior
Concrete Block - Ext Insul NOOK
411 6
0
8 0
48.0 ft2
0
0
0.4
0
_
_ 11
NE=>W Exterior
Concrete Block - Ext InsJiAUNDRY
411 3
0
8 0
24.0 ft2
0
0
0.4
0
_ 12
SE=>N Exterior
Concrete Block - Ext InsillAUNDRY
4l11 7
0
8 0
56.0 ft2
0
0
0.4
0
13
SW=>E Exterior
Concrete Block - Ext InsillAUNDRY
4! 1 7
0
8 0
56.0 ft2
0
0
0.4
0
_
14
SE=>N Exterior
Concrete Block - Ext Insul ENTRY
411 6
0
8 0
48.0 ft2
0
0
0.4
0
15
N=>SW Garage
Frame - Wood ENTRY
11 35
8
280.0 ft2
0.23
0.4
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated ENTRY
None
.39
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
I
Overhang
# Ornt ID
Frame Panes NFRC
U-Fa'ctor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 SW=>E 1
Metal Low-E Double Yes
0.63 0.25
Y
46.4 ft2
1 ft 0 in
1 ft 4 in
None
None
2 NW=>S 2
Metal Low-E Double Yes
0.65 0.21
Y
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
3 NW=>S 5
Metal Low-E Double Yes
I
0.63 0.25
Y
32.4 ft2
1 ft 0 in
1 ft 4 in
None
None
4 NE=>W 6
Metal Low-E Double Yes
I
0.63 0.25
Y
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NE=>W 8
Metal Low-E Double Yes
I
0.63 0.25
Y
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
6 SW=>E 9
Metal Low-E Double Yes
I
0.63 0.25
Y
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
7 SE=>N 12
Metal Low-E Double Yes
I
0.63 0.25
I
Y
4.7 ft2
7 ft 0 in
1 ft 4 in
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 440 ft2 440 ft2
35 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000382 1649.1 90.53
170.26
.2831
7
6/22/2018 12:04 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6
,FnRM R4nr,_gn17 INP11T St1MMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
None
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr 1044 cfm
0.85
1
sys#1
HOT WATER SYSTEM
i
#
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
/
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6 225 ftz
Attic
55 ftZ
I Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
i
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
Feb Mar
f
A r
Ma
[Xj Jun X Jul
Au
Se
Oct
[ ]Nov
Dec
HeatinH
Jan X� Feb f Xi Mar
f 1 Apr f
i May
[ ]Jun Jul
�xjAuSep
�Xj
f
Oct
[X] Nov
f X� Dec
Ventin
Jan [ Feb X Mar
[X A r [
Ma
[ j Jun [ Jul
Aug
Se
[X
Oct
[X] Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM 78
78 78
781
78 78
78
78
80
80
80
80
PM 80
80 78
78�
78 78
78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78
78 78
78
78
78
78
78
78
PM 78
78 78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM 66
66 66
66
66 68
68
68
68
68
68
68
PM 68
68 68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM 66
66 66
66
66 68
68
68
68
68
68
68
PM 68
68 68
68
68 68
68
68
68
68
66
66
6/22/2018 12:04 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
MASS
REPORT
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST.
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
JUNIOR M. BED
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
POWDER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
NOOK
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ENTRY
Name: Test Rater
Rating Compant: Test Rater
i
6/22/2018 12:04 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE MANOR Builder Name: WYNNE BUILDING CORP.
Street: THE MANOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: WYNNE BUILDING CORP. Jurisdiction:
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
i
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in ttie building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shlall be aligned with
Ceiling/attic
�
the insulation and any gaps in the air barrier shall be sealed.
The insulation iceiling/soffit
nsun any dropped pp ceilin g
Access openings, drop down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall
be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior
walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and
and
and doors
Iraming,
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed
edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joins taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures, installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
i
i
installation readily conforms to available space shall
extend behind piping and wiring-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended bythe manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and wallsior ceolonas-
a. u, aUUMOii, uisNccuun ui iuy wars snau be In accordance with the provisions of IGG-400.
6/22/2018 12:04 PM EnergyGauge® USA FBC,6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performanlce Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1644
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.635
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.240
14. Heating system: Capacity
34.8
c) Area
7c.
153A
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
i
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
8.50
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic t.
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
!
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: \ - Date:
Address of New Home: THE MANOR City/FL Zip: +T_- €R
6/22/2018 12:04:43 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Jab.
wr*lghtsoft. Pmectsummary
Enure House
QUICK CALLS,-INC.
M.STILUCIE LN.;Fr,:P1ERCiVL 34946 Phon :77246"7 Fbx-772466-0� E 11: . . . . . . .
99 OUCKC4eWOLCOM
ProLect Information
7 T
For WYNNE.BUILDINGCORP
THE MANOR, FT. PIERCE, Fl.
Notss'
11 CACTOR �C®Ply ONTI-Nin
Weather.
Winter Design Concillitio"ns
Oulsicle.clb 42: OF
' Insidedb - 70. OF
Design TO
28 OF
Heating Summary
Structure 17620 Ruh
Ducts 599f Ruh
Centralvent(ocirn) 0 Ruh
(none)
Hurniciffid6tion 0 Btuh
Piping .0 uh
Equipment load 23616- RRuh
Infiltration
Fort Pierce, FL, US
I
Method Simplified
'Cpnsltucfion -quality AW*oe
Fireplaces
Heating coolln
Area
(fJ2 .1644-
im
-Mblurfie:( 14131
1413.1
nge our
Air blia. -0.38
0.2-0
.
Eqdiv.AVF'(cfrn) 89
47
Heating. Equipment Summary
Maker
Trade
T1ERAJR CONDITIONING
Model 26HBC536AD030
AHRI ref. 3646945
Efficioncy-
8.5 -HSPF
Hed'ng_Input
,
34601) Ruh @ 47-F
T. re rise
se
2.7, OF
'1010.0w
1160 chl..
Air1low% , r:
0.049. chi/Ruh
0.08 . in H2O
:Space thermostat.
point=33 OF
BacWp:
Surnmer Design Conditi
Outside db
:90 F-
lhsjdeclb:
75 -OF
DesibnTD
15 OF
DailyL
1,14
60Moisture
Relative humidity
difference
61 -grAb
Sensible Coollinig:Equipment Load Will%
Structure
16355 . Ruh
Ducts
7744. Btuh
Central vent (0 chi)
0'.Btuh
.:(none) -
Blower
0 . Ruh
Use manufacturers data
n
Rateilswp
n 1
0.95
EqUiotnenq:fIti.seqnlspit-e llelroa'd
.22894 -Btuh
Went C0611ins,.Eciulip'Ment Loads - Izin
81rudure
2368 Btuh
D,ucts.
2473 Ruh
Central vent (0 chi)
0Ruh
-_(none)
Equipm"ight latent'load
4840 Ruh,
E quinaht Total Load.(SeniLk)
27�Ruh
�
total otal capacity at 0.70 SHR
2.7. ton
Cooling Equipment Sum m*ary
Make Carrier
Trade CARRIERAJRCONDMONING
C6hd 25HBC536AO030
Coil FX4DNF037 .
AH RI ref. 3645945:
Efficiency 12.0 EERj 15 SEER
Serisiblec6oling.
24360 Ruh
Latsht-cooling
10440 Btuh
Total cooling
34800. Btuh
Actual airflow
11.60 drn' - .
Airflowfactor
0.048 chilfth
Static re
=e
0,08- in `H2O.
Load heat ratio
0.83
111vUL:= 1 K-K Output ="0/.!dtAun, -iuulj&ut
Calculations approvedbyACCA-tci meet all requirements of Manual J Sth Ed
2018-Ma)-160BM:35
-%iw Rof ts utvwsa[2018 18.0,16ASU08101
Pagel
MOIMWfig"ftWA61WYME-THEMANOR-1644np Cak=MJB FrvtDoorMm N
- - wrightsoti Right-M Orksheefi Job:
Entire House ByEEI: Apr05, 2018.
QUICK CALLS, INC.
317 STLUCIE LN., FT: PIERdE, FL 34946 Plpne.772-466.6799. Fax 772-46"796 Emau: QUICKCALCS@AOL.COM
1
Room name
i Entlre House
GREAT ROOM
2
EVosedmall
160.9 ft
47A R
3
Room height
I 8.6 It d
9.8 it heafl000l
4
Rowndimensions
21.0 x 28.0 ft
5
Ro. marea
I .1643.5 fP
546.0. 9F
Ty
Condon
U-value
Or
HTM
Load
Area (fP)
Load .
number
(Blvhrti;"F)
(Bt h"
or .perimeter (n)
(Bhih)
or peritnebar (f0
(B>uh)
Heat
C-4
Gross.
NIPl3
Hit
Cad
Gross'
fi ns
Heat
COd:
s
; x
13AAoss
4P,6.20in '
0143
a 0770
rie
r19
400
,F21:86
, 355
3B"90
40B
i6
38a
�0
31i44981
, ' 238
0
0
0
0
4 a
0
, o
r• r 0.
r^";
�
4Atr2an,
0,770
1,ne
„.
t21:56
•..36;90
��
��
�738
,
�
1ry1�-G
13A Rocs
0.143
se
. ,. 4.00
2.55
,
104
79
$17
202
0
0
' 0
0
11
4A5.2om
0770
se
21456
19.31
4
4
94
84
0
0
0
0
�D
11D0
DMO
se
1092
ii.31
20
20
223
231
0
0
0
0
1g1
13A AocB
'4145-20m s
.3
07T0
sw
$ 400
21:58
255
33r/B
t 561
r 8
998
1
39@8
139
�1289
; T218
` r s255
0
209
0
838
r 0
532
0
SS}li
c
VJJ
13A-got s
4A5.2om
Q143
0770
nw
rrx
4.00
21.56
2 65
3690
( 310
92
237
0
950
682
604
1167.
206
0
1f
0
681
0
420
0
4A52omd
0770
fNu
2156
3690
Ifl 41
0
BBD
1505
41
0
880
1505
12C-Oav
OD31
*;
255
w 1.28
3 20
s f :,250
:
C
168 30md
D t30
1 ✓
1Ft4
1644
1473
2781
648
546
489
917
`F .,.;�r
2?A:�il."''' , �; .,.- ,
.-AIM
�
Fk
_..
.h-
v
ti
t
6
s)AEDexcurgon,
1332
1051
ErAdopelosggain I
14M
.13118
5158
6D39
12.
a In6ltratlpn
2759oom
.776
924
.261
b� Rventilation
0
0
0
0
13
Internal galr>B 230
2
..
0
. 0
.
+4pp1+4pB1 a@>her
200
0
_
SubO w (liitesab13)
17620
16355
6a82
6299
Leeaextemal load {
0
' 0
0
0
LeffitkWer
.0
0
:0.
0
'Redistiiblbn
0
0
w 0.
0
14•
Steal.
17620
10355
8082
8299
15
OlsctloadS. ' ..
34%
47%
6997
7744
M
47%
.2070
2983
Tots mom load
23616.
24099
8162
9282
Airregt�ired:(n)
1160
: 1180
400
= ' 447
�" vvri9letmaltd � - . — 2018dutay�1608'.39',.�`�-
^^^^-RIghFSrita®Lfrryerga1201.8.18A,197UD6101
Page 1
..•amertsiWriBttle011).11rAC1WYNNE-TI••EMAI+IQR-9644,ruD CaIc�MJ!}. F►antDOorfacax N
+ wtWsoftRight-A`Workishset DAt:
EARhe Hodie i Sete: AprO5,2018
QUICK CALM INC. ay
.317 ST.Woe Lm, FL PIERCE, FL 34M Phone: 772.980-8768 Fat 772406.6706 Bmalk DUiCKCALC6MARL.BOM
1
Room rem®
MA3T8R B€OR®OM'
YJI t: '
2
Sedwall
46,0 ft
A 8
3
R0pm I*BN
8,0 ft h9Dtlsopl.
.
810.4 heatlm
4
Ron dniwdons"
1,0 x 274.0 4
7.0 x 11:0 n
.5
Row, "aw
274,0 Ax
77A tF
Ty
Cer melon
U-WU6
9r
,TM
. .. (ft�
L
' Arw (W)
LW
number
(Btyisf6=�)
( ?l
sir
. pffimew a
(8w,
41 PeriO)w (m -
(Ow .
Meat
cw
Om
N/R!S
Heat.
COI ..
NOS:.
Meet:.
CW
4A6.2am �,
i AfilA
n6166
t
3@_BO
p
t p
ka' 0!
0"
j D
_ r 0
0
'.
0.
gAfilAn7_v _, ..
Om
1 n
0
11
13Awiow
4A6-20m
A1a3
0770
ee
oa
400
21.85
2165
19.21
0
0
0
0
A
0
A
0
0
0
0
0
0
0
0
0
91D0
0390
e3
1082
1131
0
0
A
0
D
0
A
0
r
18A4Ac6
Arm r
ks� sOx143
0770
sw
t3uV
" a0D
21i5f3
r4 2Blb
337.5
z 6a
0
A9
a 0
266
A
��
A
D
p
r
p.
4A52om
a y
np
_.
.j..y417r7A
131Ni
_:T216A
3t3x13=A
.�
0
13Ae
4A5.20m
0143
0770
ffYY
rw
400
27 68
255
389D
194
32
72
0
290
002
184
1107
0
0
0
0
0
0
0
0
4A5�2rxnd
0770
rW
21,E
3920
0
0
0
0
0
0
A
0
C
9A�30ind
0 m
Olin
IAD
f 274
-274
248
480
77
77
09
129
27t38
..9;QA,
.a..274
.�..`.:;.4tt
s
F-
d.:t.
` , '
_ .ti'„„ -1
az',�'" '
ar
a
v
}1 v f
y ] k• ;.f 5
1_ .,.L "f
...'�
, i
�
j
_ ., -. . 5i
7 ..x.'�'. {
�
.. 1
.1 r
f� �' r. {
6
C)AEDe>mrslon
318
a
:Fanetopetoss�gain
3546
2001
"
69
127
12
a) Infib9on
738
2D8
0'
0
b). Acornveirglatlon
I
0
0
0.
0
13
emmal ams 0ppentso 230
2:
460
0
0
'Appllanoe.4oTher
;
-
fl
a
SubDoQ (IineSSt 13)
4287
.2470.
69
127
Leese)bmd load
.. 0:
.0
.0
0
Les8banaw
0
0
0
0
RdalBUimm -
0
0
0
0
14
Sub W
4287
$470
68
IV15
.:Dudloods
34%
47%
1459:
1643
34Qk
470A
'm
80,
_ -
Total room load -.
5745
8112
.
Q3
187
Airrequired(c1m).
�'
2W
298
.5
' 91.
Calculations approved bvACCA to meet all,reauirements of Manual J 8ih Ed.
->�+- wrigisesoi'e- l 2018=May 160Pe e
hFSUte®U0Brse1201818 0.16 RS000101
...unenslwrighlseftHUAQWYMEzR.EMANOIt-1644a*- CeIc=MJB'FnxtDwrfares N 8 2
wflghtiWt R -J'@ ksheet
En..
Sp I
n.. rt H
QUICK CALLS; INC
317ST.LUCIE.LN..Fr.PIE.RCE,F43494OPhDw.7,7246Wg9 Fax 772-46MZ98. EmanQucKcALcs@AoL.c6m
Job:
MUM 'Apr OS,.2Di8
By.
1
Roommme
CLST.
MATH
0 t
9.0 ft..0
3RoDmWght
8.0 ft heaftol
8ft hwftd
4
Roomdimend=
7.0 x 6.0 ft
-
6.0 x 9.0 ft
5
Rodmaiea
-35.0 fr.
54.0 ftz
Ty
Con&Ldw
UAslue
or
M
LOO
Ama (T)
load
number
RUW09
or
Wmeler (to
'(Ehuh)
or perimebar (ft)
Cross'a
NFIS
Heat
Cool
Gmm
NSS
HeM.
cool
0
dAO
0
A.-
:1-V
13A4oc5
0.143
so
4.00
2-55.
0
a
0
0
0
0
0
0
11
4A5-2om
0.770
so
21:56
19.31
0
0
0
0
a
0
0
0
.
. . .
I PO
-0.39D
so
IOL92
.0
0
- 0
0
.0
a
I . . 6
0
-SXcs� -40
A,&
OAJ
6A
jiAK
,,
7
6
0
4A, &2
S' r
1
5,"
-2,7-- Al 36.
Y,
Wa
4
-
ISA4 =
0.143
rw
4.00
'255
0
0..
0
0
0
0
0
0
.4AS-2om.
OVO
. rw
21.58
3BAD
0
0
0
0
0
0
0
0
4A d
0.77
nw
MOO
0
0
0
0
0
0
.0
0
p
. . . .
I'.3
aQ
. .
v A, ;.
C,
0.
0.90
1.1§6
35
-69
54
64
48
.91
C,
F,7
F.�
Maim
7711,
�7
Ar
-5 t
A.
S
-a
"7
......
.....
"off,
8
fi'E' D e'xw*-do'n'
31
158
BM
488
12.
a�' IdItraft
0
0
144.
41
Roornbedlafon.
0
0
13
Internalgains Oaupeints@ .230
i 0
0
0
0
Appl4ircWbdw*
.01
0
SupbWl (lin.mAb 13)
31
'0
844
627
LEssei4etflal bad
0
0
0
0
Q
D.
D
.-Q
14
Subtotal-
M
58
044
527
16
-:lDudkxd.s
34%.
.47%1:
11
27
349/al
-47/'a I
-287
249
TOW mom bad
42
85
1131
.776
AlrmWfed(om)
j.
2
41
661:
37,
wwrl-!opfttwcWL-
Page 2.
"."ritowili WACIWYNNE-IHEMANOWIS44AO.Cil6=WB*FmDoorfac=N
wrightsoft°
i
f
i
RighWO biksheei
Enfir..e. House
QUICK CALLS, INC
317 ST. LUCIE LN., Fi PIERCE, FL 34046 Phone: 772"46"799 Fax`77246H796 Email; QUICKCALCOMOLLOM
Job:
Date: Aps 05, 2010
sr•
Room name
YJTDMEN
JUNIORMBED'
2
E*-OwdVd
111p a
14A ft
3
Rsrom;hei t
I B.0 ft heaVoeol
8,Q .ft hwwd
4.
Rein dlmerliow
1,0 x 180.0 a
1,D 2 199.0 ft
B
fiscmere6
160,0 1F
.198;0 fv
Ty
U•VEgtt0
Or
HTM
dva (d)
Lead _
Area (ftry
Loag
number
(t1{uwn
(Bwh" '
cu . paimWer (ft)
(f2uh)
or pedmewr (4)
(661h) .
Meat ..
Goal .
NO18
Mkt.
Cool
S3rrxls ..
N]P18
Meat.
Cod
6
y<�1�4oas
4A5?1p�n
, t 0193
0770
rye
n0
4.90
2Mal
> 2630
s 3880
P
0
0'
4
s 0
0
0
112
0
86
364
�A4
7
13A-0o
0143
. Se
400
265
0
0
0
0
0
0
0
11
4A5-20m
0770
se
21M
19.31
0
0
0
0
0
0
0
0
1100 ..
0200
1 AM
1121
L 0
p
0
0
0
Q
0
i 9
13A 9or�
4AB2oin t t
0149
;< 0770
9(✓
9y
400
c 2156
265
}337,6
88
0
862
D+'
r 0
324
yr 0
0
r` 0.
L 4
0
p
D
r Pp
r' t p
4AB2oA1
0770M
t,,,�.21.69
...35;13
.0
.. z 0
0
.: '... ±0.
_.4.
13A 4pr
A 143
nw
4;00
2.65
0
0
0
0
0
0
0
0
4A5-2om
0770
nw
21,60
36190
0
0
0
0
0
0
0
0
�--G
4A5.2amd
0770
fw
21M
$6.90
0
0
0
0
0
o
D
0
P
12C 00w
AA91
265
,128
Q
0
0
A
104
1D4
C
166�30md
0.032
0,90
169
180
18D
161
302
198
195
177
6:i3
ZZA.�tl
x _.
-
-.•
.,
,
.. -:::
. _ .�' ... ,:..;° -,
.,
�-':.
.•... .:::
i.. ,..
�' ,.. `: ..
�.
J t.`
.. ';rI ,.
., - "..+.
;., ..,�
_. rl A.V.
'- .. +:�;t
z
I
s 1
Y
;
6
OAEDe=ra(on_ .
..
.
Enval9p®.10 n
016
479
1560
1277
12.
. ® Ir�ilirdW
177
80
226
63
b;' Roommedllldtl0n
Q
0
0
.
0
13
biit+rrlalgain .230
0
-' 0.
9
,4ppl er
�0
$tlofal(lulesEo13)
895
2528
1786
1840
Lessatva kad .
I.
0
0
0.
0
L�sslnn4Qr
p,
' p
p
- p
0
0
6
0
14.
StADDlel
985,
2528
1705
1040
15
'>tluc loads
349/a
AM
339
11,07
34"/o
4751a
607
635
__ ___ -
Totairocmit.load
'
� 1333
. • 3728
i382
1876
Ai ►1�6 (fin) . __
..
..05
179
117
• 9S
-�- wr�Nfi� fC^ RIBhFFula�Unvarse12096.46A;18'R3U08401'.
unerrslwag hleoltFNAfti'NNiVTHEMANVR-1694auul Colo- MJB;:FreriDoerfeoe®;N
2016dday1608; '.35
.. Peg®4
- wrightsoft° Right-J@ Worksheet Job.,
Entiro House apro$, zo7s
By:
QUICK( CALCS, INC.
317SKLUCIELN.,Fr.. PIERCE, FL34946PhOne:772-46M799 Fax'7724666796 Einwl:QUICKCALCs@AOLCOM
1
Room name
BATH
POWDER
2
E>¢osedw9ll
0 ft
5.0 ft
3
Room h'*"'
8.0 ft heaftol
8.0 ft heaftol
4
Room dimerrsons'
5.o x 10.0 If
7.0 x 5.0 ft
b
Room area
500 fl?
35.0. W
Ty
Contudon
U-wlue
Or
HTM .
Area
(fly
Load
Area (F.)
Load
number
(BUINE-°F)
{B>trfPillN)
or
peiime* (lU
(Bhrh)
or wmelor (Ig
(BUrh)
Heat
Cod' .
Grp
NPPIS
Heat
Cod
Gross
NIPIS
Heat:
Cool
8
13AiIXS -r
Or143
re
x A 00
255
0
0
x0
' 6 0
y
4ACr2am
0770
ne
2156
+38.90
0
i
077q
, :rie
21:56
38:90
_:'':0
,., . _.,:., 0
... , ::: '.r 0
:., - - E 0
, .----, r,0
0
: _;' r
;; 0
�1
13A4ocs
0143
se
400
265
0
0
0
0
0
0
_0
0
0
'—D
4A62om
0770.
se
21.56
1931
0
0
0
0
0
0
0
0
11D0
0390
se
10.02
1131
0
0
0
0
0
0
0
0
13A4ocs ` :
0143
r 07T0
soil
�9W
400
21�a8
258
3378
0
0
0
s r p
0
0
i 0
' 0
40
8
34
1,
134
1 39
; 8fi
218
i � r
r
k
S
4A5 ftm
A5-tom
0.143
0770
-nw
rw
4,00
2150
2
3890
0
0
0.
0
.<�d0
0
0
... A,'�,,.,.0
0
0
. ,< ..�.0,
0
0
..:. �
0
0
,...,.0::
0
0
:�0.
055.
0
a—G
4A5.2omd
0770
nva
2155
36:80
0
0
0
0
0
0
0
0
N_40102
C
16B410mcl
0032
r
090
148
`000
5o
50
45
eq
35
35
31
59
F.`s:.,:
22A ipl .,.:.: , ..
_.'. 0989
.:'r
.......2769
.
*0
0
nY
.r
w
o.
r
1
+
8
c)AED'eaoourson
-3
79
EnMopelowgain
147
133
443
441
12
a Infitrafm
p
p
80
23
b; Raom iefflation
0
0
0
0
13
Lil0mal gWnS Qoovarlb@ 230
0
0
0
Appliatroes&er
.0
Subtot81'@ries6to13) -
147
133
524
483 .
Lessodernal load
0
0
.0
tesstransrer
0
0
0.
0
Redl�1'uiition
0
0
0
0
14
Sul tal
147
133
524
4W
15
':Drxtloads
1341/6
47%
80
63
34%
47%1
178
219
Total room load
i
197.
195
702
.101.
.9
34
.063
33
Calculations approved byACCAto.meet-all neauiroMonits of Manual J 8th Ed-
-�`�+ wc.RnEn' R-i 201&May160839i5
-^-- Right
rMMso$uteSUrmaer�r2018180I6'R$L108101 9e5
'tea_unei6.hltmvACIWYNNE-THENfOmR-i644.rio CaIc=.MJ9 FrortDoorfaoes N Pa
i
+wrighboft° Right-M:Woftheei
Entire. House
QUICK CALCS; INC.
.317 ST. LUCIE LN., FT. PIERCE, FL.34946 Phone: 772466.8799 Fax: 772466-6796 Emell; QUICKCALCS@AAOL.COM
Job:
Date: Apr ",.2018.
sy:
1
RoDmname
NOOK
- LAUNDRY
2
Bposedvlali.
SO 1t
'17.0 ft
3
Room betghl
8.0 ft heallaod
8.0 It heat wd
4
RoomdUrle119ionS
7.0 x 6.0 ft
7.0 x 70, ft
$
ftom area
42.0 V
49,0 V
Ty
Conaudion
U-mue.
Or
HTM
AM r_ 019
Load
Area (Its
Load
mrmber
v tW►1l' n
(Btuh"
Cr .perimeter (d)
(BM)
or Perim (0)
(BG4►} '
Hit
Cool
atM
NlPSS
-Heat
Cod:
Grams. -
NFIS
Heat
Coot:
8
,
13A°40Cs
4A5 2ofn
0143
0770
IIB
�E
4
r 2156
265
3880
}
0
0
0
0
0
0
0
0
2R
0
y 24
0
98
0
81
0
_
<
0770
~
-rte„
r.2156._,Ki.3B:9D
...
.. A
....,... Y.Q
., .. 0
`. 0
.:....:.. 0.
.. 0
,. $0,
.: p
V�!
0,143
- se
4.00
2:55
0
0
0.
0
88
62
207
131
11
1--G
4A5-2Dm
0770
so
21,58
19,31
0
0
D
0
4
4
94
84
D
11D0
0.390
s8
1092
1131
0
0
D
0
0
D
0
0
r
13A`�4Dcs
4A520m
0143
0770
eiN
eW
' w 400
21s58
268
0376
4
+{8
" 48
192
w 122
�5H
0
56
0
224
Q
�143
0;
t
4A62Ciit 3�
07/0
, eN
,r T2196
36:13.
?._._ 0
rt
.?u z
13A
"tom
0143
0770
rw
ryw
400
21M
2.55
SOM.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
A
0
4A5.20md
0770
nw
210
3090
0
0
0
0
0
0
0
0
P
12CI09(
QA91
293
128nT0
k ; 0
° 0
C
188 30fidL
0 032
0,90
1.60.
42
42
38
71
49
49
44
82
F
22Adp1``
0989
2789
000
1 �42
8
„188
0
49,
.. 17
471
:Q
�
fir:.
,'.•
,. .. ::li�l
h1.
�
,..
^` .,
i=�
..
,..
.,.. f
r.. ..a
i• .u.,
-• __
—...' �r••r ?„
.._
-._
"w
...
.h:,.,
—ftin }
,...f
...:5. ,.
..aid
,.Fr
.Y :.....'i
S
h
5
J
t
o
Ij4
.0
c)AEDmiracn
I
-4
-11
Fmeiopelosefgain
I
396
189
1130
-401
12
a) InBltraCon
p.
b)' RwnwnG.idon
p
p
.0
13
Uit�n gains gwvwb@_ 230
0
0
q
0
AppltancaslDtlrer
*WM(IInss6t093)
492
218
1409
588
lar6entall0ad
0
0
0
0,
LesoharlsNr .
0
0
Red&bjkn
.'0
D
0
94:
Subtil492
�480.
16:
"Du lDeds
39%
M
98
902
340/o
_ 47%u
.290
Total ►mn load
No
318
:1000
637
AirriLlm(dm) .
32
96
93
.
40
Rigt!-Spte49;Wrnrersal Z018'18A,18 RSlt08'109
r�A unertsVWilgt#5oI1hNAG11UY�tliIE"TkiEMANOR•1flA4Ay CeIDflMJB FrOrfDoetaoes: N
2010Mey"16080:35
Page a
-F`ff- wrightsoft° Rig11t4,009ftheei
Entire House -
QUICK CALLS, INC.
317 ST. LIME LN„ FT.' PIERCE, FL 34948 Ph=: 772.966!8799 FOX 772.486 6796 Small: QUICKCALCSQAOL COM
Job:
Date: Apr 06, 2018
By:
1
Room dame
ENTRY
2
EVOOV-411.
619 ft'
3
.
Room hel*
8.0 ft heat wd
4
RoomdmerWom
1.0 x 103:5 ft
-'5
'ROWnWWI
� 103.5:ftT
Ty
Constnrceon
U-value.
Or
HTM
Area
(R)
Load
Area
load
number
(Bluhfft'-1)
(Bbm
dr
peimeter (fo
(SM)
or perimeter
Heat
C 01 '
Grose:
NIPS
Heat
Cod:
Grose
INPG-Heat'
'
: Coot
B
y!
1"
4Afi 2o_m
0143
A770
ne
rie
400
$ 2156
¢ 55
36 90
, ; 0
0
0
0
0
0
0
ri--GG
`48
4
13Ar4pC8
014�
400
256
i
29
111
70
11
4A5.2om
0770
sa
2155
1931
i 0
0
0
0
11D0
0390
fe
1092
1131
24
20
223
231
13A-0or8 Y
4A5tom
Y 0143
0770
av
sn�
400
2158
255
3376
i d
0
0
O
0
F 0
0
0`
A1A62o1r1.0770
> J Y
X63A
bias
0.�143
nw
4.00
265
� 0
0
0
0
4A52om
0770
nw,
21.56
3690
0
0
0
0
*5S,Zmd
0770
rwv
2158
369D
0
0
0
0
p ;
12GOsw s
#.W; Y0091
C
18&30md
0A32
9.90
1.88
I 104
104
93
174
2769
0
. ..
i'S" x
s -_. �. ..,.. i
... ,F,.t
�..:
� , ..
f ,-
-,. .r
.. t,. , A.
4...v ... �
h ., =-i., c•
iK ..- . ,,.
tl _ �'.
i 5
6
c)AEge rs!on _
A2
EmelopelosaWn
wo
699
12
' aj .lnfiWon
96
27
b) Rtoomvenpl4on
0.
0
13
kitwx2sains owupantsa 2�
0
0
Appliahaeslofher
0
Subtotal'(Ifhesebl3)
g�
�
.
Iserrral lead
0
0
L es61r2(tsfer
I
0
0
Redistribution
0
0
14
SublDtal
956
626
i5.
:.Dtittloads.
34%
.47%
325
29
Total roomload
1282
: 923
.
Airrequired(dm)
g3
44
YGIVM 1-IV' oWfdl WrGY MV f,V-WWr-% W.II IW'WL:QU 11
/RyaL�ili 'RIghFSife�.t)riversat2d18180:16 RSW8101
Ave*%Wr9ttiAHMAQWYNNE-THEMANOR-1844•np ;Calo=tRJe .Fr6itDoo.rfaoert N
2018.May-1608�8�'
Paee7
Duct � Stalin Sumr�a ,, :
wr%ghtsofk° 'Y rY vats; Apra§,2Q18
Entire House?: BY:
QUICK CA,L,CS; INC:
317 S.T, LUCIE Mo FT PIERCE; FL 34946 Phooe;:772.406,0709
`rHFr MANOR, FT. RIERGE, FL
Heating:
cooling
Extemal.static pressure
0.08 in H20'
0.08 inH2O
Pressure:'losses
0. in H2O
0 in H2O
Avallable.staticpressure
j 0.08- in H2O
0,08 .in H2O
supply. treturn available Pressure
0.040./0.040 in H2O
0,040/0D40 in H2O
Lowestfiction rate
0.051 in/1ON
0.051. in/100ft
Actuai•airflow.
.1160 crm
1160 cfiT1
Total elrective length (CEL)
156 ft
Supp. r Detail
Name
Design
@Juh)
Htg
(Cim)
Gig .
(ch)
Design
FR
Diam
(In)
Hx W
(in)
Duct
Mail
.Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h. 197
10
9
0.074
4.0
Ox 0
MFx
18.4
90.0
St1
CLST.
c 85
2
4
0..071
4.0
Ox 0
MFx
22.5
90.0
sH
ENTRY
h 1282
63
44
0.10E
5.0
Ox 0
-MFx
4.0
70.0 .
GREATROOM
c 4641.
200
-223
0.054
8.0
OxO
MFx.
37.3
110.0
st3
GREATROOWB
c .4641
200
223
0.053
8.0
0x0
V1Fx
39:8
110.0
st3
JINMORM BED
h 2392
117
95
.0.070.
7.0
OxO
MFx
24.7
90.0
st1
KITCHEN
c 3726
66
179
0.076,TO
OkO
MFx
242
90.0
SH
LAUNDRY
h 1888
93
40
0.678
5.0
Ox-0
MFx
13.1
90.'0
s12
MIRATH
h 1131
56
37
- 0.067
6:0
Ox0
VIR
29.6
90.0
st1
MASTERBEDROOM
h 2873
141
123
0.054
6.0
M.
MFx
39:3
110.0
813
MASTERSEDROOM-A
h 2873
141
123
0.051.
60
Ox 0
MFx
45.9
110.0
st3
NOOK
h 660
32
15
0.082
5.0
Ox0
MFx
7.8
90.0.
st2
POWER
h 702 1
34
33
0.082
5:0
Ox 0
mFx
7.2
90.0
s12
WIC
c 187
S
9
O.056
4.0
Ox0
MFx
33.8
110:0.*
sC3
Trunk
Htg
Clg
Design
Maloc
Diam
H x W
Duct
Name
Type
(dM)
(dm)
FR
,(fpm)
(in)
.(inj
Material
Trunk
s13
PeakAUF
687
702
0.05.1
894.
12.0
.0 .x 0
1AnIFIx
st1
SO
PeakAVF
937
1027
'0.051 "
961
14.0
0 x 0
AMPlx :
st2
PaakAVF
160.
88
0078
361
9.0.
0 x 0
1/inlFlx
wrightsraft' 2018 May 180838�8
•w �»•.��, �9�-Sv�Umereal201818,fl,16RSU08101
_Arnerb%WrI&twftHVACWYNNE-THE MANOR-1944nQ CaIc=MJ8 Frort�.owfacev N Pagel
Return
Branch
Detail
Table
Name
Gdile
Sits (in)
Htg
{cirri)
Gg
(drii)
TEl_
(ft)
Design
FR
ikloc
#pin)
Dam .
(in).
H x W
(in)
Studljoist
Opening (in)
Duct
Matt
Trtink
rb1
OX0
1160
1160
0
O
0
0
Ox 0
\AFx
->' verriglstsoftA. 20184WI808�836
,1 .. •,a . _. � .,, , , Rigit-sutaouriversaI201818.0.16 RSU08101 Paget
ACCK ...une O WrigMWrtHVAG W..M F-THE MOORr1644.rup 'Ca1c=MlJ8 FrartOoortaxs N
i