HomeMy WebLinkAboutGAS PIPING SCHEMATICk
�� • �VWIVIV�
By
BOARD OF
COUNTY
COMMISSIONERS
0 To 4eg-r 9 140?
`Q GAS .PIPIN
tA2J - [
[1.4J [u
TANKh_L1] [L3] [LSI F
SIZE
L2] 11.61'
[A1] [A3]
r
TANK SIZE:_ GALS.
APPLICANCE - TYPEISIZE
Al a
AZ I-eS.T
A3 LjXr fX A2 I '�f�4
A4
A5
A6
PLANNING & DEVELOPMENT -
SERVICES .DEPARTMENT
Building and Code Regulation
Division
9
L1O]
[AS]
ST. LUCIE'COUNTY BUILDING DIVISION
REVIEWED FO CO PLIANCE
REVIEWED BY
DATE y�
PLANS AND PERMIT MUST BE KEPT ON.JoB
OR NO INSPECTION WILL BE MADE.
RTI1 ",?D6^0.361
PIPING LENGTH & SIZE •t I (PIPE SIZE WAS TAKEN FROM
L1 _ _FT. INCH DIA. THE 2014 FBC FUEL GAS CODE—
L2 FT. INCH DIA. TABLE 402 L-)J
L3 FT. INCH DIA.
L4 FT. INCH DIA. ?E. ?o L
L5 FT. INCH DIA
L6 FT. INCH DIA. % �a •��
L7 FT. INCH DIA.
L8 FT. INCH DIA.
L9 FT. INCH DIA.
�L1O FT. INCH DIA FILE
Ll1 FT. INCH DIA. Cop�
L12 FT. INCH DIA .
Website: wer.stlucieco.gov
2300 Virginia Avenue - Fort Pierce, FL. 34982-5652
Phone (772) 462-1553 FAX (772) 462-1578
Revised 7/22/14
4Qx
gxa"
1►Y'�'_ ' �s Glt(UV�� "'
m
a
it
0 CONS:°
Ma, � C .
PUNA
J �aa
0
11,
of
CF
,0`,00�1
o
t r
! 40, g 7
MISS,
JC-FP
17cX tE0Wj,-j1A ;,
THIS VESSEL IS DESIGNED FOR THE STORAGE
OF LIQUEFIED PETROLEUM GAS ONLY
5uo Gae (( off
TOP VIEW
14 GA. COLLAR
SLOTTTED HOLE
W12112' X 3 W" SLOT
CENTERED OVER
OFFSIDE
RELIEF VALVE
HAS
INGE
-- - --__— - ® HAS
,IHINGEI
esn nnnnamme.
I
_ I _ R.S.
II II I
LOATGAUGE
it
I
II I
--
G "Optional)---
SIDE ELEVATION
10
Stt U-U1 FOR ANY
UNSPECIFIED WELD DETAILS
14 GA F & D HEAD j�16 O.D.-
WITH 1" SF --,I
L15
FITTING LAYOUT
tr! n-21
OPTIONAL
DOME BRACKET FOR
UG GREEN ONLY--- _
3/4 DIAM.' ^"'—'/ LONG. WELD
HOLES SEAM
(4) PLACES ' May vary long seam
END VIEW loc. to miss leg weld
T
1�
CERTIFIED BY: QUALITY'STEEL CORPORATION
CLEVBAND, MS-FREMONf, OH-WE3TJORQA!!, to
MAX ALLOW. WORK PRESS 250 PSI AT 400 • F•
NE MD.M T. .20 'F. AT 250 psi
YE4RBNLT
W.
U Ri4 SER. N0.
LENGTH 20 IN. OBT8—k 37.5 K
HEAD 7H IN. sHHLTHC Ik
GR THE 15 SUiFACEAREA 100 M Fr.
CONTVNERAssEMBL HEMD•R' HEMI.
FOR LP OAS WATER CAPACITY —5—OT GALLOti3
GENERAL NOTES:
1, LIFTING LUGS DESINGED FOR TOTAL LIFTING WEIGHT OF 1500A.
2. TOTAL EMPTY WEIGHT IS 9509.
3. ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED
4. COMPLETE TANK DRIED TO REMOVEALL MOISTURE
5. ALL WEIGHTS AND CAPACITIES ARE APPROXIMATE
6. EXTERIOR OF TANK TO BE GRIT BLASTED
7, PAINT PER SHOP ORDER
8. VACUUM PURGE TANK
9. DIMENSION ARE SUBJECT TO CHANGE WITHOUT NOTICE
(NON -PRESSURE RETAINING COMPONENTS ONLY)
IQ THREADS OF ALL FITTINGS TO BE COATED WITH COMPOUND
SUITABLE FOR USE WITH LP GAS
11. FLOAT GAUGE TO BE INSTALLED WITH FLOAT ARM 45° OFF
LONGITUDINAL CENTERLINE OF TANK
�.vuc: AOMt StUI IUN VI It UIV. I
NOTE; TANK MUST BE INSTALLED LEVEL, NTH ALL LEGS IN SAME STANDARDS: UNDERWRITERS LABORATORIES INC. MH-7203
PLANE TO ASSURE EVEN DISTRIBUTION OF LOAD AND OPTIMIZE PART NO: 0105002x MATERIAL SPEC PA. 58 LP GAS CODE
ACCURACY OF GAUGE DEVICE
MARK Ott. SIZE TYPE FITTINGS COUPLINGS SA-105
REGO SERVICE MARK OTY. DESCRIPTION DVYG. NO. REV. BY: DESCRIPTION DATE TANK FLANGES SA-1050f SA-181-70
A 1 1 XH FLG. 006684GT RELIEFVALVE 1 1 SHELL- 0.218' X 83'X 11611116"-SA41_ 14 CDH ADDED HINGE& HASP AT SHELL 12112101 AQ4PTOR SA-105
B 1 1 XH FLG. 9WiBBT YLCRNAIeGiPOR iAOlESi6iBBBBI]l LC4T GAUGE 2 2 HEADS
-174
XNFLO.
L007879T
FILLVALVE
3
2
-37° I.D.A0.IW-HEMI:SA414C
DFTINGLUGS
0-63
CDH
ADDED NOTE AT LEG DESCRIPTION
3/6W2
-5� :G:ABOVEIUNDERGR2UND
PROPAN_F TAN.I(TYP-E:105(FORMERL-Y.�AV T4A)314
CDH
REVISED MOMTPRESSURE T0250PSI
Brz3/02
314
XH FLO,
pT007656R910.6
MULTI VALVE
4
2
TANK LEGS
D-3
r17
COH
CORRECTED RELIEFVLV. MODEL NOS.
11/5/03
n+ev.c: nwe
007690UTCHEK-LOK
5
1
DOME
D-6
CDH
CORRECTED SHELL LENGTH
11H203
QUALITY STEEL CORPORATION
114
XH FUG.
6
i
DATA PLATE
D-60
19
wlo
REVISED COMPANY NAME
12MU7
7
1
REGULATOR BRACKET
D-10
20
wlo
NEW NAME PLATE AND MOVED RELIEF
VALVE
3
�=�IBA4
8
1
DIP TUBE LENGTH= 1a5' FOR 80 Yb� 40'F
9
",
2
HINGE AND HASP OR DOME BRACKETS
D-10, D.19,
D47
21
bts
REVISED SHELL LENGTH
22
Dts
CHANGE FITTING LOCATION
04/10/14
1
ANODE ATTACHMENT
D-17
23
TAW I
NEVVNAME PLAT ANDS D. LEGS,
LUGS, BRACKETS
01l04/18
��
01 / 03 / 00
RAC
cw+o+®er
TVw
-
a23
owrmryxo:
X - 500
AGUG STANDARD
Lp
GROUND LEA
r`
I4 l9fMhLE,SS STEEL. CABLE
POLYPROLEWTUSING
lill'I'llIj I'd
f� r T �� / AGAINST' TAtjK
1 ,�
`,� ti f � r� 518- x 8- TILER ANC11OR
v HELIX
ok
\ x� � •tire 'fj f w� j !�/ '� �j� �., Ret
-
GROUND
1I4" STAINLESS
STEEL, gABLE
L.P- CAS--
F
TM9R ANCHOR
PE
_ ENGINEERS SEAL S9UL'.`1 IN GDLQ; ! -NOT
'IC Ti Gt1t?3iL: `f D7t 3 Df�t Altt{E, V1R�i @ contr,crntlu ar is AU.rx�
L;AGHxLtRLA _
CIF-1 -
DRAWL. BY. RF
NO., '14t304 ENCINEER1 Q � � DE41GNED � jAx,
an-it A TF_ .r,.....�� . .
1