Loading...
HomeMy WebLinkAboutPRODUCT APPROVALi BCIS Home Log In User Registration Hot Topics Submit Surcharge j Stats & Facts Publications FBC Staff BCIS Site Map'} LinksSearch j bc USER: Public Use royal pr Product Approval Menu > Product or Application Search > Application List Search Criteria Refine Search Code Version 2017 FL# 17022.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Qualiy Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL I Searrh QPC.M.. - AnnH—f-r..wc. FL# Tvoe Manufacturer Validated B,y Status F 1-L 7022- Revision Extreme Metal Fabricators, LLC Zachary R. Approved R7 FL#: FL17022.1 Priest, P.E. History Model: 1 - "5V Crimp" (116) (813) 480-3421 Description: 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32'I plywood or Wood Deck with fasteners Category: Roofing Subcategory: Metal Roofing tAODfoved by ❑RPR. Annm"wle by r1RPR .boll 6n w..�e,.�..w �..w ...wa..� �.. .,._ .....- __„__.�_ .._- . _. .- Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under:Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: ® = eCi� Credit Card; .: 'Safe r� Palm City, FL 34990 Compliant with Florida Building Code 2017 (61 ed.) Compliant with Florida Product Approval Rule ;# 611320-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel. Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/160 min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads T METHOD 1 METHOD.2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING . . 16" o.c. 16" o.c. 8" O.C. 6" o.c. FASTENER SPACING (ALONG_ Panel width) 12" o.c. 12" o.c. 12" o.c. 12" o.c. FASTENER SIZE #9 no #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report, 1305893.01-45048 OS/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897--1 *Design pressure margin of safety 2:1 Locke Bowden, P.E. does not have, not will acquire a financial int@T4y sir �cg 4�►mj%facturing or distributing products under this evaluation. �. •+' �, Locke Bowden, P.E. is not owned, operated, or controlled by airy cornpar*)rnA0f9turer, or distributing products under this report. -. Jar' � GSJrT E� 4, ..��efl::°rblN►� FL17022.1 5VI , .limp (26GA Steel), 24" Wide Root :.nel -Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. .or mil/ Q Dedc 15/32" or greater Plywood, or Wood plank — FastenersI- #9 x 1-1/2" Min.I or #10 x 1-1/2"Min. pe Pr A' for Row 5 V Crimp Roof Panel Spacing and Designgn Pressures Hex Washer Head Wood Screws 12� 30 OPTION& STRIATIOt 9S Nominal 12" O.C. Panel Profile Nominal 12" O.C. Fasten E9 x 1-1/2" Min. or #10 x 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c, across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or -Wood plank