Loading...
HomeMy WebLinkAboutSCOPE OF WORKi SCANNhU BY PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 E-mail pwelchinc@aol.com June 6, 2018 Re: Residential Re -Roof 501 Nettles Blvd Jensen Beach, FL SCOPE OF WORK: Install new Metal Roof (Extreme Metal Fabricators, LLC "5-V Crimp" (FL #17022.1) at above referenced address over new underlayment, and existing plywood sheathing. DESIGN CRITERIA: FBC 2017 ASCE7-10 PROJECT DATA: BUILDING HIEGHT = 10'-0" A= 3' MEAN ROOF HIEGHT = <20' ROOF ANGLE = 4:12 SHAPE = PITCHED HIP / GABLE ADJUSTMENT FACTOR =1.00 IMPROTANCE FACTOR = 1.00 WIND VELOCITY V ult = 165NMH WIND VELOCITY V asd =128 MPH EXPOSURE = D ENCLOSURE CLASS = ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = -0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE (PSF): ZONE 1 (Field) = -40.3 ZONE 2 (Perimeter/ Ridge) = -68.0 ZONE 3 (Comers) = -99.8 Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 June 6, 2018 501 Nettles Blvd Jensen Beach, FL 1 of 3 METAL ROOFING ATTACHMENT REQUIREMENTS: Metal roofing to be attached with corrosion resistant Hex -Head wood screws #10 x 1 V2" minimum with weather sealing washers (minimum 3/16" penetration through deck). Fasteners shall be placed through the panel ribs at 12" on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING = 16" O.C. ZONE 2 (Perimeter/ Ridge): FASTENER SPACING = 16" O.C. ZONE 3 (Corners): FASTENER SPACING = 8" O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HORZ. Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 & 2:-93.5PSF / Zone 3:-10IPSF Therefore O.K. UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1, and FBC 15074.5.2. Underlayment shall be Approved 30# Roofing Felt. DECK INSTALLATION: Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL # 17022.1), manufacturer's specifications, and the Florida Building Code 2017. Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 June 6, 2018 501 Nettles Blvd Jensen. Beach, FL 2 of 3 rh ;�ti 4, 14 �A ROOF ZONE PLAN A 3' Q, Q, ®= ZONE DESIGNATION (TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HORZ. Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 June 6, 2018 501 Nettles Blvd Jensen Beach, FL 3 of 3