HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFBCIS Home I Log In I User Registration
I Submit Surcharge
Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search I
Florida
o
Product Approval
USER: Public User
a
EUvcc�.ar i�tm
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL*
Application Type
Code Version
Application Status
Comments
Archived
FL17022-R7
Revision
2017
Approved
ST. LUCZE c%,N y ;
REVIEWED FOR COJ
RE` IEWED B
DATE /[ (V
PLANS AND PERX11T
0II 1NO INS,PECTI.O V
08/18/2017v. date reapply 08/21/17
1
.' JJF 1"PT ON JOB
BE 21YU-0E.
Product Manufacturer Extreme Metal Fabricators, LLC THESE PLANS AND ALL PROPOSED WORK
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
ARE SUBJECT TO ANY CORRECTIONS
(772) 872-8034
flvalidation@yahoo.com
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
Authorized Signature Richard McKuhen
COMPLY WITH t 1 AU .A P to"Quall
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive CONCEALED FASTENERS OR ATTACHMENTS
Palm City, FL 34990 (772) 872-8034 ARE THE RESPONSIBILITY OF THE
� rchard@emfab.net CONTRACTOR OF RECORD
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hard'copy Received
LOCKE BOWDEN _
PE-49704
Keystone Certifications, Inc. =� '' f' `
04/22/2024
Zachary R. Priest, P.E.
E*01 Validation Checklist - Hardcopy Received
FL17022 R7 C01 FL 17022.1 5 V CRIMP sscpdf
Standard
Year
TAS125
2003
UL1897
2012
UL 580
2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
of Products
Method 1 Option D
08/18/2017
08/25/2017
08/28/2017
10/10/2017
FL # I Model, Number or Name I Description
17022.1 I 1 - "5V Crimp" (R6) 126 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32' plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.1 5 V CRIMP ssrpdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pdf
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturers installation instructions.
17022.2 12 - "5V Crimp" (R6) 10.032' Aluminum, 3/8" Rib height, 21' wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3
3 -1.5" Mechanical Seam" (115)
1.5" rib height,16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32' plywood or wood deck
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24aa ssrpdf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
of use. Install the assembly in compliance with the installation
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
method listed in this report and applicable code sections of
seam 24aa ssr.pdf
FBC. Refer to manufacturer's installation instructions.
Created by Independent Third Party: Yes
17022.4 14 -1.5" Mechanical Seam" (R5) 11.5" rib height,16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to 15/32" plywood or Wood Deck
with clips and fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other. Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
Installation Instructions
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.pdf
Created by Independent Third Party: Yes
17022.5
5 - "1 in. Nail Strip" (115)
1" rib height,16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf,
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and limitations
FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf
of use. Install the assembly in compliance with the installation
Created by Independent Third Party: Yes
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.6
6 - "1 in. Nail Strip" (115)
1" rib height,16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
Approved for use outside HVHZ: Yes
ALUM ssrodf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
of Use. Install the assembly in compliance with the installation
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
method listed in this report and applicable code sections of
ALUM ssr.pdf
FBC. Refer to manufacturer's installation instructions.
Created by Independent Third Party: Yes
17022.7
7 -'1.5 in. Nail Strip" (R5)
1.5" rib height,19".wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other. Refer to evaluation report for conditions and limitations
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Created by Independent Third Party. Yes
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturers installation instructions.
17022.8
8 - "EMAX Rib" (115)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and limitations
FL17022 R7 AE FL 177022.8 EMAX Rib ssr.pdf
of use. Install the assembly in compliance with the installation
Created by Independent Third Party: Yes
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.9
9 -" PBR MAX" (115)
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other. Refer to evaluation report for conditions and limitations
FL17022 R7 AE FL 17022.9 PBR RIB ssr..pdf
of use. Install the assembly in compliance with the installation
Created by Independent Third Party: Yes
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
Back Next
Contact Us:: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an WEED employer. Copyright 2007.2013 State of Florida.:: Privacy Statement:: Accessibility Statement:: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 201 Z licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
Palm City, FL 34990
Compliant with Florida Building Code 2017 (61 ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" ox.
16" ox.
8" O.C.
6" ox.
FASTENER SPACING (ALONG Panel width)
22" ox.
12" ox.
12" o.c.
12" o.c.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL 580-06 & 1897-041 Test Report
IM893.01-450-18 05/02/14
Test Report
F3366.01-450-18 12/18/15
TAS 125-03 Test Report
D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1 *Design
pressure margin of safety 2.1
t o. r�op;y
Locke Bowden, P.E. does not have, not will acquire a financial int lq e!' F,tg ` 4� gj! facturing or distributing products
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by any► coiApan#prnbW&ZtureP, ordistributing products under this
report.
S Tt� ;717
job
no
•%.`•'TONAL �`.�;:� .
i
} FL17022.1 Crimp (26GA Steel), 24" Wide F �f Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
tp
0o/
Deck
15GT or greater Plywood, or
Wood plank
— Fasteners -
N x 1-1/2° Min. or
#10 x 1-1/2° Min, per Tab/e A' for Row 5-V Crimp Root Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
24"
17
318" mom
Panel Profile
Nominal 12" Nominal 12"
O.C. O.C.
Fasten
_t9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
—fable "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15/32" or greater
Plywood, or
- Wood plank